| # More info and the latest version of the config are now in the repo: https://github.com/vladyspavlov/esphome-must-inverter | |
| substitutions: | |
| inverter_id: inverter | |
| updates: 5s | |
| api_key: xxx | |
| ota_password: xxx | |
| esphome: | |
| name: inverter-monitor | |
| comment: "Inverter monitor" | |
| esp32: | |
| board: esp32dev | |
| framework: | |
| type: esp-idf | |
| wifi: | |
| ssid: !secret wifi_ssid | |
| password: !secret wifi_password | |
| captive_portal: | |
| logger: | |
| level: DEBUG | |
| api: | |
| encryption: | |
| key: ${api_key} | |
| ota: | |
| password: ${ota_password} | |
| uart: | |
| - id: uart_inverter | |
| baud_rate: 19200 | |
| tx_pin: GPIO19 | |
| rx_pin: GPIO18 | |
| stop_bits: 1 | |
| parity: NONE | |
| data_bits: 8 | |
| debug: | |
| direction: BOTH | |
| dummy_receiver: false | |
| modbus: | |
| - id: modbus_inverter | |
| uart_id: uart_inverter | |
| send_wait_time: 200ms | |
| modbus_controller: | |
| - id: must_inverter | |
| address: 0x04 | |
| modbus_id: modbus_inverter | |
| command_throttle: 200ms | |
| setup_priority: -10 | |
| update_interval: ${updates} | |
| sensor: | |
| # charger sensors | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15201 | |
| name: "PV Charger Workstate" | |
| register_type: holding | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15202 | |
| name: "PV Charger MPPT state" | |
| register_type: holding | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15203 | |
| name: "PV Charger Charging state" | |
| register_type: holding | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15205 | |
| name: "PV Charger Voltage" | |
| register_type: holding | |
| unit_of_measurement: "V" | |
| accuracy_decimals: 1 | |
| icon: mdi:sine-wave | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15206 | |
| name: "PV Charger Battery voltage" | |
| register_type: holding | |
| unit_of_measurement: "V" | |
| accuracy_decimals: 1 | |
| icon: mdi:sine-wave | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15207 | |
| name: "PV Charger Current" | |
| register_type: holding | |
| unit_of_measurement: "A" | |
| accuracy_decimals: 1 | |
| icon: mdi:current-dc | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15208 | |
| register_type: holding | |
| name: "PV Charger power" | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15209 | |
| register_type: holding | |
| name: "PV Charger Radiator temp" | |
| unit_of_measurement: "°C" | |
| accuracy_decimals: 1 | |
| icon: mdi:temperature-celsius | |
| # - platform: modbus_controller | |
| # modbus_controller_id: must_inverter | |
| # address: 15210 | |
| # register_type: holding | |
| # name: "PV Charger External temp" | |
| # unit_of_measurement: "°C" | |
| # accuracy_decimals: 1 | |
| # icon: mdi:temperature-celsius | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15212 | |
| register_type: holding | |
| name: "PV Relay" | |
| icon: mdi:electric-switch | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15217 | |
| register_type: holding | |
| id: charger_total_mwh | |
| internal: true | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15218 | |
| register_type: holding | |
| id: charger_total_kwh | |
| internal: true | |
| filters: | |
| multiply: 0.1 | |
| - platform: template | |
| name: "PV Charger Accumulated charger power" | |
| unit_of_measurement: kWh | |
| lambda: !lambda 'return (id(charger_total_mwh).state * 1000.0 + id(charger_total_kwh).state );' | |
| accuracy_decimals: 1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15219 | |
| register_type: holding | |
| name: "PV Charger Accumulated day" | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15220 | |
| register_type: holding | |
| name: "PV Charger Accumulated hour" | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15221 | |
| register_type: holding | |
| name: "PV Charger Accumulated minute" | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| # inverter sensors | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25201 | |
| register_type: holding | |
| name: "Inverter Work state" | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25205 | |
| name: "Inverter Battery Voltage" | |
| register_type: holding | |
| unit_of_measurement: "V" | |
| accuracy_decimals: 1 | |
| icon: mdi:sine-wave | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25206 | |
| name: "Inverter Voltage" | |
| register_type: holding | |
| unit_of_measurement: "V" | |
| accuracy_decimals: 1 | |
| icon: mdi:sine-wave | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25207 | |
| name: "Inverter Grid voltage" | |
| register_type: holding | |
| unit_of_measurement: "V" | |
| accuracy_decimals: 1 | |
| icon: mdi:sine-wave | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25207 | |
| name: "Inverter Grid voltage" | |
| register_type: holding | |
| unit_of_measurement: "V" | |
| accuracy_decimals: 1 | |
| icon: mdi:sine-wave | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25208 | |
| name: "Inverter BUS Voltage" | |
| register_type: holding | |
| unit_of_measurement: "V" | |
| accuracy_decimals: 1 | |
| icon: mdi:sine-wave | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25209 | |
| name: "Inverter Control current" | |
| register_type: holding | |
| unit_of_measurement: "A" | |
| accuracy_decimals: 1 | |
| icon: mdi:current-dc | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25210 | |
| name: "Inverter Current" | |
| register_type: holding | |
| unit_of_measurement: "A" | |
| accuracy_decimals: 1 | |
| icon: mdi:current-dc | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25211 | |
| name: "Inverter Grid current" | |
| register_type: holding | |
| unit_of_measurement: "A" | |
| accuracy_decimals: 1 | |
| icon: mdi:current-ac | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25212 | |
| name: "Inverter Load current" | |
| register_type: holding | |
| unit_of_measurement: "A" | |
| accuracy_decimals: 1 | |
| icon: mdi:current-ac | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25213 | |
| name: "Inverter Power" | |
| register_type: holding | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25214 | |
| name: "Inverter Grid power" | |
| register_type: holding | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| value_type: S_WORD | |
| icon: mdi:flash | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25215 | |
| name: "Inverter Load power" | |
| register_type: holding | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25216 | |
| name: "Inverter System load" | |
| register_type: holding | |
| unit_of_measurement: "%" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| # MOST INFO | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25233 | |
| register_type: holding | |
| name: "Inverter AC radiator temp" | |
| accuracy_decimals: 1 | |
| unit_of_measurement: "°C" | |
| icon: mdi:temperature-celsius | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25234 | |
| register_type: holding | |
| name: "Inverter Transformer temp" | |
| unit_of_measurement: "°C" | |
| accuracy_decimals: 1 | |
| icon: mdi:temperature-celsius | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25235 | |
| register_type: holding | |
| name: "Inverter DC Radiator temp" | |
| unit_of_measurement: "°C" | |
| accuracy_decimals: 1 | |
| icon: mdi:temperature-celsius | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25237 | |
| register_type: holding | |
| name: "Inverter Relay state" | |
| icon: mdi:electric-switch | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25238 | |
| register_type: holding | |
| name: "Inverter Relay state Grid" | |
| icon: mdi:electric-switch | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25239 | |
| register_type: holding | |
| name: "Inverter Relay state Load" | |
| icon: mdi:electric-switch | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25240 | |
| register_type: holding | |
| name: "Inverter Relay state NLine" | |
| icon: mdi:electric-switch | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25241 | |
| register_type: holding | |
| name: "Inverter Relay state DC" | |
| icon: mdi:electric-switch | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25242 | |
| register_type: holding | |
| name: "Inverter Relay state Earth" | |
| icon: mdi:electric-switch | |
| # Inverter Accumulated discharge power | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25247 | |
| register_type: holding | |
| id: discharger_total_mwh | |
| internal: true | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25248 | |
| register_type: holding | |
| id: discharger_total_kwh | |
| internal: true | |
| filters: | |
| multiply: 0.1 | |
| - platform: template | |
| name: "Accumulated discharger power" | |
| unit_of_measurement: kWh | |
| accuracy_decimals: 1 | |
| lambda: !lambda 'return (id(discharger_total_mwh).state * 1000.0 + id(discharger_total_kwh).state);' | |
| # Inverter Accumulated buy power | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25249 | |
| register_type: holding | |
| id: buy_mwh | |
| internal: true | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25250 | |
| register_type: holding | |
| id: buy_kwh | |
| internal: true | |
| filters: | |
| multiply: 0.1 | |
| - platform: template | |
| name: "Accumulated buy power" | |
| unit_of_measurement: kWh | |
| lambda: |- | |
| return (id(buy_mwh).state * 1000.0 + id(buy_kwh).state); | |
| accuracy_decimals: 1 | |
| # Inverter Accumulated sell power | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25251 | |
| register_type: holding | |
| id: sell_mwh | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25252 | |
| register_type: holding | |
| id: sell_kwh | |
| filters: | |
| multiply: 0.1 | |
| - platform: template | |
| name: "Accumulated sell power" | |
| unit_of_measurement: kWh | |
| accuracy_decimals: 1 | |
| lambda: !lambda return (id(sell_mwh).state * 1000.0 + id(sell_kwh).state); | |
| # Inverter Accumulated load power | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25253 | |
| register_type: holding | |
| id: load_mwh | |
| internal: True | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25254 | |
| register_type: holding | |
| id: load_kwh | |
| internal: True | |
| filters: | |
| multiply: 0.1 | |
| - platform: template | |
| name: "Accumulated load power" | |
| unit_of_measurement: kWh | |
| accuracy_decimals: 1 | |
| lambda: !lambda return (id(load_mwh).state * 1000.0 + id(load_kwh).state); | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25273 | |
| register_type: holding | |
| value_type: S_WORD | |
| name: "Inverter Battery power" | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25274 | |
| register_type: holding | |
| value_type: S_WORD | |
| name: "Inverter Battery current" | |
| unit_of_measurement: "A" | |
| accuracy_decimals: 1 | |
| icon: mdi:current-dc | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25275 | |
| register_type: holding | |
| value_type: S_WORD | |
| name: "Inverter Battery grade" | |
| unit_of_measurement: "V" | |
| icon: mdi:alpha-V | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25277 | |
| register_type: holding | |
| name: "Inverter Rated power" | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| select: | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| id: energy_use_mode | |
| name: "Inverter Energy use mode (parameter 00)" | |
| address: 20109 | |
| optionsmap: | |
| "SBU (Solar/battery/utility)": 1 | |
| "SUB (Solar/utility/battery)": 2 | |
| "UTI (Utility only)": 3 | |
| "SOL (Solar only)": 4 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| id: charger_source_priority | |
| name: "Inverter Charger source priority (parameter 10)" | |
| address: 20143 | |
| optionsmap: | |
| "CSO (Solar first)": 0 | |
| "SNU (Solar and utility)": 2 | |
| "OSO (Solar only)": 3 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 20111 | |
| id: inverter_ac_input_voltage_range | |
| name: "Inverter AC input voltage range (02)" | |
| optionsmap: | |
| "VDE (184-253VAC)": 0 | |
| "UPS (170-280VAC)": 1 | |
| "APL (90-280VAC)": 2 | |
| "GEN (Generator)": 3 | |
| number: | |
| - platform: modbus_controller | |
| id: batt_float_voltage | |
| name: "PV Charger Float voltage" | |
| unit_of_measurement: "V" | |
| address: 10103 | |
| value_type: U_WORD | |
| multiply: 10 | |
| - platform: modbus_controller | |
| id: batt_absorb_voltage | |
| name: "PV Charger Absorb voltage" | |
| unit_of_measurement: "V" | |
| address: 10104 | |
| value_type: U_WORD | |
| multiply: 10 | |
| - platform: modbus_controller | |
| id: batt_stop_dischg | |
| name: "Inverter Battery stop discharging voltage" | |
| unit_of_measurement: "V" | |
| address: 20118 | |
| value_type: U_WORD | |
| lambda: "return x * 0.1; " | |
| write_lambda: |- | |
| return x * 10 ; | |
| - platform: modbus_controller | |
| id: batt_stop_chg | |
| name: "Inverter Battery stop charging voltage" | |
| unit_of_measurement: "V" | |
| address: 20119 | |
| value_type: U_WORD | |
| multiply: 10 | |
| - platform: modbus_controller | |
| id: batt_low_voltage | |
| name: "Inverter Battery low voltage" | |
| unit_of_measurement: "V" | |
| address: 20127 | |
| value_type: U_WORD | |
| multiply: 10 | |
| - platform: modbus_controller | |
| id: batt_high_voltage | |
| name: "Inverter Battery high voltage" | |
| unit_of_measurement: "V" | |
| address: 20128 | |
| value_type: U_WORD | |
| multiply: 10 | |
| - platform: modbus_controller | |
| id: solar_charger_current | |
| name: "Inverter Charger current" | |
| unit_of_measurement: "A" | |
| address: 20132 | |
| value_type: U_WORD | |
| multiply: 10 |
Всем привет. Взял платку по ссылке из гита https://github.com/vladyspavlov/esphome-must-inverter и спокойно стал ждать, не вдаваясь в подробности. Платка пришла и тут оказалось что у неё с одной стороны 4 контакта с другой 3, а на скринах 4Х4. Ну тут по идее всё ясно - берём с ЮСБ центральные жилы и землю на троих, питание на ЕСП 5в, с ЕСП забираем землю и 3.3 на другую сторону платки, туда же рх.тх, А+Б+ чередуем, РХ\ТХ тоже если не пошло. НО - А какую в итоге взять прошивку? esp32-pv18.yaml? Только вот у меня серия не 1800, а eco. По смыслу я надеюсь что регистры у них должны +- совпадать.
И ещё вопрос - а на платах с3 кто то подобное собирал? А то я смотрю все в едином порыве берут s3 и чуть ли не nvidia shild - зачем так мощьно?
Блин, ребят - подскажите кто чем может, не хочет у меня работать ни в какую. Грешил что случайно спалил рс485 платку пока подключал, заказал ещё одну. та же фигня - на ней постоянно моргает рх и никакие данные не приходят, ни в юсб порту, ни в езернет по 1,2,3 жилам. Что за прошивка под ЮСБ? Загнал в ЖПТ чат, тот рассказывает дивные истории про то что оно там напрямую может работать без рс485 переходников, хотя тут ни у кого не видел такого сетапа...
В логах пишет какую то фигню -
12:33:46 | [W] | [modbus_controller:284] | Duplicate modbus command found: type=0x3 address=25226 count=1
12:33:46 | [W] | [modbus_controller:284] | Duplicate modbus command found: type=0x3 address=25233 count=3
12:33:46 | [W] | [modbus_controller:284] | Duplicate modbus command found: type=0x3 address=25237 count=6
12:33:46 | [W] | [modbus_controller:284] | Duplicate modbus command found: type=0x3 address=25247 count=8
В общем подскажите какую всётаки прошивку нужно шить? Может в самом инверторе ещё нужно что то включать?
Блин, ребят - подскажите кто чем может, не хочет у меня работать ни в какую. Грешил что случайно спалил рс485 платку пока подключал, заказал ещё одну. та же фигня - на ней постоянно моргает рх и никакие данные не приходят, ни в юсб порту, ни в езернет по 1,2,3 жилам. Что за прошивка под ЮСБ? Загнал в ЖПТ чат, тот рассказывает дивные истории про то что оно там напрямую может работать без рс485 переходников, хотя тут ни у кого не видел такого сетапа... В логах пишет какую то фигню - 12:33:46 | [W] | [modbus_controller:284] | Duplicate modbus command found: type=0x3 address=25226 count=1 12:33:46 | [W] | [modbus_controller:284] | Duplicate modbus command found: type=0x3 address=25233 count=3 12:33:46 | [W] | [modbus_controller:284] | Duplicate modbus command found: type=0x3 address=25237 count=6 12:33:46 | [W] | [modbus_controller:284] | Duplicate modbus command found: type=0x3 address=25247 count=8 В общем подскажите какую всётаки прошивку нужно шить? Может в самом инверторе ещё нужно что то включать?
Начните с того, что в кабеле между инвертором и батареей оставьте только необходимые для коммуникации CAN провода (2 для CAN и GND).
Я имел такую же ситуацию, пока не обрезал лишнее. Судя по всему, BMS много чего кричит и в CAN, и в RS485. И это ТОТ ЖЕ САМЫЙ RS485, что и в жилах D+/D- бокового порта USB-A.
https://gist.github.com/vladyspavlov/5ac21cb58923482eff8e7bbb2d0854b3?permalink_comment_id=5961143#gistcomment-5961143 -
Нет кабеля между инвертором и батареей. Взял юсб, вытащил с него центральные на А\Б, питание 5 вольт на есп32, землю на землю ЕСП и рс485, 3.3 вольта с ЕСП на рс485. В общем то там сложно как то сильно перепутать. Но реакции ноль - никакие данные не идут.
Может у моей модели кардинально другие настройки? по смыслу тот де пв18, но у меня ECO-2012, они их запихали в отдельную категорию на сайте - https://www.mustpower.com/product/eco-series-2-12kw/
https://gist.github.com/vladyspavlov/5ac21cb58923482eff8e7bbb2d0854b3?permalink_comment_id=5961143#gistcomment-5961143 - Нет кабеля между инвертором и батареей. Взял юсб, вытащил с него центральные на А\Б, питание 5 вольт на есп32, землю на землю ЕСП и рс485, 3.3 вольта с ЕСП на рс485. В общем то там сложно как то сильно перепутать. Но реакции ноль - никакие данные не идут. Может у моей модели кардинально другие настройки? по смыслу тот де пв18, но у меня ECO-2012, они их запихали в отдельную категорию на сайте - https://www.mustpower.com/product/eco-series-2-12kw/
Насчет ECO-2012 информации (и даже общего понятия) не имею, увы.
без flow_control нечего не получите.
Привіт ! Хочу поділитися інформацією. Мені вдалось знайти регістр SOC батареї. Я використовую : MUST PH18 5448 pro + jk bms JK-PB2A16S20P Інвертор спілкується з батарею по протоколу CAN Pylontech. Відсотки SOC батареї що відображаються на інверторі можна знайти у регістрі 44180 - це пряме значення. Для додавання датчика використана конфігурація:
- platform: modbus_controller # Battery SOC MUST PH18 5448 PRO + CAN battery PYLON tech
name: "Battery SOC" register_type: holding address: 44180 unit_of_measurement: "%" accuracy_decimals: 0 device_class: battery value_type: U_WORD
PS: Я думаю що це буде стосуватися інверторів серії PH18 PV18 може хто підтвердить ЩЕ ?
Дякую за регістр, там дійсно знайшов SOC на MUST PV19 4024 Exp + JKBMS по Can (Pylontech), нажаль там нема десятих відсотків.
На один регістр вище в мене значення = 100 (може кому це буде потрібно).
в доплнение к сообщению
sergey777s
Недокументований, значення, отримане з BMS батареї через CAN
101-max U bat
102- емкость ?
103-min U bat
104 - min cell
109-U bat
110-curent
111-temp
проверяйте !
Поменял ЕСПху и всё завелось из коробки. ХЗ что это было, но главное завелось. Результат не сильно понравился - в родной прошивке не хватает ограничений для нумберов, слабо представляю как ползунком из веб интерфеса подтянуть до 13.5 вольт что либо если там диапазон 32 миллиона, может для НА не критично, но в целом почему бы сразу не добавить.
С другой стороны - значения не меняются и имеют какие-то не интуитивно понятные названия.
Кто может подсказать можно ли управлять float и charge величинами? И на каких оно адресах? То что получаю сейчас не похоже на мои настройки инвертора - Inverter Battery high voltage 15.0 V ; Inverter Battery low voltage 11.3 V ; PV Charger Float voltage 13.6 V (на вид оно, но подписан как ПВ - тоесть речь о солнечной, а не городской, или не важно?);
И что значит PV Charger Absorb voltage 14.2 V ?
Пока ещё колдую, но может кто ответит и пояснит, если интересно для себя пилю прошивку тут https://github.com/cahbegit/HA/blob/main/esphome/must.yaml, убрал все упомнинания про PV так как нет панелей, может перебдел?
диапазон 32 миллиона,
зависит от step:
речь о солнечной, а не городской
не важно

@Alexandrmv
Ще можна спробувати: