| substitutions: | |
| inverter_id: inverter | |
| updates: 5s | |
| api_key: xxx | |
| ota_password: xxx | |
| esphome: | |
| name: inverter-monitor | |
| comment: "Inverter monitor" | |
| esp32: | |
| board: esp32dev | |
| framework: | |
| type: esp-idf | |
| wifi: | |
| ssid: !secret wifi_ssid | |
| password: !secret wifi_password | |
| captive_portal: | |
| logger: | |
| level: DEBUG | |
| api: | |
| encryption: | |
| key: ${api_key} | |
| ota: | |
| password: ${ota_password} | |
| uart: | |
| - id: uart_inverter | |
| baud_rate: 19200 | |
| tx_pin: GPIO19 | |
| rx_pin: GPIO18 | |
| stop_bits: 1 | |
| parity: NONE | |
| data_bits: 8 | |
| debug: | |
| direction: BOTH | |
| dummy_receiver: false | |
| modbus: | |
| - id: modbus_inverter | |
| uart_id: uart_inverter | |
| send_wait_time: 200ms | |
| modbus_controller: | |
| - id: must_inverter | |
| address: 0x04 | |
| modbus_id: modbus_inverter | |
| command_throttle: 200ms | |
| setup_priority: -10 | |
| update_interval: ${updates} | |
| sensor: | |
| # charger sensors | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15201 | |
| name: "PV Charger Workstate" | |
| register_type: holding | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15202 | |
| name: "PV Charger MPPT state" | |
| register_type: holding | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15203 | |
| name: "PV Charger Charging state" | |
| register_type: holding | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15205 | |
| name: "PV Charger Voltage" | |
| register_type: holding | |
| unit_of_measurement: "V" | |
| accuracy_decimals: 1 | |
| icon: mdi:sine-wave | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15206 | |
| name: "PV Charger Battery voltage" | |
| register_type: holding | |
| unit_of_measurement: "V" | |
| accuracy_decimals: 1 | |
| icon: mdi:sine-wave | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15207 | |
| name: "PV Charger Current" | |
| register_type: holding | |
| unit_of_measurement: "A" | |
| accuracy_decimals: 1 | |
| icon: mdi:current-dc | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15208 | |
| register_type: holding | |
| name: "PV Charger power" | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15209 | |
| register_type: holding | |
| name: "PV Charger Radiator temp" | |
| unit_of_measurement: "°C" | |
| accuracy_decimals: 1 | |
| icon: mdi:temperature-celsius | |
| # - platform: modbus_controller | |
| # modbus_controller_id: must_inverter | |
| # address: 15210 | |
| # register_type: holding | |
| # name: "PV Charger External temp" | |
| # unit_of_measurement: "°C" | |
| # accuracy_decimals: 1 | |
| # icon: mdi:temperature-celsius | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15212 | |
| register_type: holding | |
| name: "PV Relay" | |
| icon: mdi:electric-switch | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15217 | |
| register_type: holding | |
| id: charger_total_mwh | |
| internal: true | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15218 | |
| register_type: holding | |
| id: charger_total_kwh | |
| internal: true | |
| filters: | |
| multiply: 0.1 | |
| - platform: template | |
| name: "PV Charger Accumulated charger power" | |
| unit_of_measurement: kWh | |
| lambda: !lambda 'return (id(charger_total_mwh).state * 1000.0 + id(charger_total_kwh).state );' | |
| accuracy_decimals: 1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15219 | |
| register_type: holding | |
| name: "PV Charger Accumulated day" | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15220 | |
| register_type: holding | |
| name: "PV Charger Accumulated hour" | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 15221 | |
| register_type: holding | |
| name: "PV Charger Accumulated minute" | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| # inverter sensors | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25201 | |
| register_type: holding | |
| name: "Inverter Work state" | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25205 | |
| name: "Inverter Battery Voltage" | |
| register_type: holding | |
| unit_of_measurement: "V" | |
| accuracy_decimals: 1 | |
| icon: mdi:sine-wave | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25206 | |
| name: "Inverter Voltage" | |
| register_type: holding | |
| unit_of_measurement: "V" | |
| accuracy_decimals: 1 | |
| icon: mdi:sine-wave | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25207 | |
| name: "Inverter Grid voltage" | |
| register_type: holding | |
| unit_of_measurement: "V" | |
| accuracy_decimals: 1 | |
| icon: mdi:sine-wave | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25207 | |
| name: "Inverter Grid voltage" | |
| register_type: holding | |
| unit_of_measurement: "V" | |
| accuracy_decimals: 1 | |
| icon: mdi:sine-wave | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25208 | |
| name: "Inverter BUS Voltage" | |
| register_type: holding | |
| unit_of_measurement: "V" | |
| accuracy_decimals: 1 | |
| icon: mdi:sine-wave | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25209 | |
| name: "Inverter Control current" | |
| register_type: holding | |
| unit_of_measurement: "A" | |
| accuracy_decimals: 1 | |
| icon: mdi:current-dc | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25210 | |
| name: "Inverter Current" | |
| register_type: holding | |
| unit_of_measurement: "A" | |
| accuracy_decimals: 1 | |
| icon: mdi:current-dc | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25211 | |
| name: "Inverter Grid current" | |
| register_type: holding | |
| unit_of_measurement: "A" | |
| accuracy_decimals: 1 | |
| icon: mdi:current-ac | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25212 | |
| name: "Inverter Load current" | |
| register_type: holding | |
| unit_of_measurement: "A" | |
| accuracy_decimals: 1 | |
| icon: mdi:current-ac | |
| filters: | |
| multiply: 0.1 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25213 | |
| name: "Inverter Power" | |
| register_type: holding | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25214 | |
| name: "Inverter Grid power" | |
| register_type: holding | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| value_type: S_WORD | |
| icon: mdi:flash | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25215 | |
| name: "Inverter Load power" | |
| register_type: holding | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25216 | |
| name: "Inverter System load" | |
| register_type: holding | |
| unit_of_measurement: "%" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| # MOST INFO | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25233 | |
| register_type: holding | |
| name: "Inverter AC radiator temp" | |
| accuracy_decimals: 1 | |
| unit_of_measurement: "°C" | |
| icon: mdi:temperature-celsius | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25234 | |
| register_type: holding | |
| name: "Inverter Transformer temp" | |
| unit_of_measurement: "°C" | |
| accuracy_decimals: 1 | |
| icon: mdi:temperature-celsius | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25235 | |
| register_type: holding | |
| name: "Inverter DC Radiator temp" | |
| unit_of_measurement: "°C" | |
| accuracy_decimals: 1 | |
| icon: mdi:temperature-celsius | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25237 | |
| register_type: holding | |
| name: "Inverter Relay state" | |
| icon: mdi:electric-switch | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25238 | |
| register_type: holding | |
| name: "Inverter Relay state Grid" | |
| icon: mdi:electric-switch | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25239 | |
| register_type: holding | |
| name: "Inverter Relay state Load" | |
| icon: mdi:electric-switch | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25240 | |
| register_type: holding | |
| name: "Inverter Relay state NLine" | |
| icon: mdi:electric-switch | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25241 | |
| register_type: holding | |
| name: "Inverter Relay state DC" | |
| icon: mdi:electric-switch | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25242 | |
| register_type: holding | |
| name: "Inverter Relay state Earth" | |
| icon: mdi:electric-switch | |
| # Inverter Accumulated discharge power | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25247 | |
| register_type: holding | |
| id: discharger_total_mwh | |
| internal: true | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25248 | |
| register_type: holding | |
| id: discharger_total_kwh | |
| internal: true | |
| filters: | |
| multiply: 0.1 | |
| - platform: template | |
| name: "Accumulated discharger power" | |
| unit_of_measurement: kWh | |
| accuracy_decimals: 1 | |
| lambda: !lambda 'return (id(discharger_total_mwh).state * 1000.0 + id(discharger_total_kwh).state);' | |
| # Inverter Accumulated buy power | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25249 | |
| register_type: holding | |
| id: buy_mwh | |
| internal: true | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25250 | |
| register_type: holding | |
| id: buy_kwh | |
| internal: true | |
| filters: | |
| multiply: 0.1 | |
| - platform: template | |
| name: "Accumulated buy power" | |
| unit_of_measurement: kWh | |
| lambda: |- | |
| return (id(buy_mwh).state * 1000.0 + id(buy_kwh).state); | |
| accuracy_decimals: 1 | |
| # Inverter Accumulated sell power | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25251 | |
| register_type: holding | |
| id: sell_mwh | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25252 | |
| register_type: holding | |
| id: sell_kwh | |
| filters: | |
| multiply: 0.1 | |
| - platform: template | |
| name: "Accumulated sell power" | |
| unit_of_measurement: kWh | |
| accuracy_decimals: 1 | |
| lambda: !lambda return (id(sell_mwh).state * 1000.0 + id(sell_kwh).state); | |
| # Inverter Accumulated load power | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25253 | |
| register_type: holding | |
| id: load_mwh | |
| internal: True | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25254 | |
| register_type: holding | |
| id: load_kwh | |
| internal: True | |
| filters: | |
| multiply: 0.1 | |
| - platform: template | |
| name: "Accumulated load power" | |
| unit_of_measurement: kWh | |
| accuracy_decimals: 1 | |
| lambda: !lambda return (id(load_mwh).state * 1000.0 + id(load_kwh).state); | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25273 | |
| register_type: holding | |
| value_type: S_WORD | |
| name: "Inverter Battery power" | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25274 | |
| register_type: holding | |
| value_type: S_WORD | |
| name: "Inverter Battery current" | |
| unit_of_measurement: "A" | |
| accuracy_decimals: 1 | |
| icon: mdi:current-dc | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25275 | |
| register_type: holding | |
| value_type: S_WORD | |
| name: "Inverter Battery grade" | |
| unit_of_measurement: "V" | |
| icon: mdi:alpha-V | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 25277 | |
| register_type: holding | |
| name: "Inverter Rated power" | |
| unit_of_measurement: "W" | |
| accuracy_decimals: 1 | |
| icon: mdi:flash | |
| select: | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| id: energy_use_mode | |
| name: "Inverter Energy use mode (parameter 00)" | |
| address: 20109 | |
| optionsmap: | |
| "SBU (Solar/battery/utility)": 1 | |
| "SUB (Solar/utility/battery)": 2 | |
| "UTI (Utility only)": 3 | |
| "SOL (Solar only)": 4 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| id: charger_source_priority | |
| name: "Inverter Charger source priority (parameter 10)" | |
| address: 20143 | |
| optionsmap: | |
| "CSO (Solar first)": 0 | |
| "SNU (Solar and utility)": 2 | |
| "OSO (Solar only)": 3 | |
| - platform: modbus_controller | |
| modbus_controller_id: must_inverter | |
| address: 20111 | |
| id: inverter_ac_input_voltage_range | |
| name: "Inverter AC input voltage range (02)" | |
| optionsmap: | |
| "VDE (184-253VAC)": 0 | |
| "UPS (170-280VAC)": 1 | |
| "APL (90-280VAC)": 2 | |
| "GEN (Generator)": 3 | |
| number: | |
| - platform: modbus_controller | |
| id: batt_float_voltage | |
| name: "PV Charger Float voltage" | |
| unit_of_measurement: "V" | |
| address: 10103 | |
| value_type: U_WORD | |
| multiply: 10 | |
| - platform: modbus_controller | |
| id: batt_absorb_voltage | |
| name: "PV Charger Absorb voltage" | |
| unit_of_measurement: "V" | |
| address: 10104 | |
| value_type: U_WORD | |
| multiply: 10 | |
| - platform: modbus_controller | |
| id: batt_stop_dischg | |
| name: "Inverter Battery stop discharging voltage" | |
| unit_of_measurement: "V" | |
| address: 20118 | |
| value_type: U_WORD | |
| lambda: "return x * 0.1; " | |
| write_lambda: |- | |
| return x * 10 ; | |
| - platform: modbus_controller | |
| id: batt_stop_chg | |
| name: "Inverter Battery stop charging voltage" | |
| unit_of_measurement: "V" | |
| address: 20119 | |
| value_type: U_WORD | |
| multiply: 10 | |
| - platform: modbus_controller | |
| id: batt_low_voltage | |
| name: "Inverter Battery low voltage" | |
| unit_of_measurement: "V" | |
| address: 20127 | |
| value_type: U_WORD | |
| multiply: 10 | |
| - platform: modbus_controller | |
| id: batt_high_voltage | |
| name: "Inverter Battery high voltage" | |
| unit_of_measurement: "V" | |
| address: 20128 | |
| value_type: U_WORD | |
| multiply: 10 | |
| - platform: modbus_controller | |
| id: solar_charger_current | |
| name: "Inverter Charger current" | |
| unit_of_measurement: "A" | |
| address: 20132 | |
| value_type: U_WORD | |
| multiply: 10 |
Поменял ЕСПху и всё завелось из коробки. ХЗ что это было, но главное завелось. Результат не сильно понравился - в родной прошивке не хватает ограничений для нумберов, слабо представляю как ползунком из веб интерфеса подтянуть до 13.5 вольт что либо если там диапазон 32 миллиона, может для НА не критично, но в целом почему бы сразу не добавить.
С другой стороны - значения не меняются и имеют какие-то не интуитивно понятные названия.
Кто может подсказать можно ли управлять float и charge величинами? И на каких оно адресах? То что получаю сейчас не похоже на мои настройки инвертора - Inverter Battery high voltage 15.0 V ; Inverter Battery low voltage 11.3 V ; PV Charger Float voltage 13.6 V (на вид оно, но подписан как ПВ - тоесть речь о солнечной, а не городской, или не важно?);
И что значит PV Charger Absorb voltage 14.2 V ?
Пока ещё колдую, но может кто ответит и пояснит, если интересно для себя пилю прошивку тут https://github.com/cahbegit/HA/blob/main/esphome/must.yaml, убрал все упомнинания про PV так как нет панелей, может перебдел?
диапазон 32 миллиона,
зависит от step:
речь о солнечной, а не городской
не важно
в доплнение к сообщению
sergey777s
Недокументований, значення, отримане з BMS батареї через CAN
101-max U bat
102- емкость ?
103-min U bat
104 - min cell
109-U bat
110-curent
111-temp
проверяйте !