Save pavax/8d6ed250765d89cb281d4a1762b8d2e8 to your computer and use it in GitHub Desktop.
blueprint: | |
name: Aqara TRV E1 External Temperature Control | |
description: > | |
This automation allows the Aqara TRV E1 Smart Radiator Thermostat to use temperature readings from an external sensor rather than its internal sensor. Whenever the temperature sensor reports a new value, it is sent to the TRV for more accurate climate control. | |
domain: automation | |
source_url: "https://gist.github.com/pavax/8d6ed250765d89cb281d4a1762b8d2e8" | |
input: | |
external_temp_sensor: | |
name: External Temperature Sensor | |
description: Select the temperature sensor that will provide temperature readings to the Aqara TRV. | |
selector: | |
entity: | |
filter: | |
domain: sensor | |
device_class: | |
- temperature | |
aqara_trv_device: | |
name: Aqara TRV Device | |
description: Select the Aqara Smart Radiator Thermostat E1 that will receive the external temperature data. | |
selector: | |
device: | |
multiple: false | |
filter: | |
- integration: mqtt | |
manufacturer: Aqara | |
model: Smart radiator thermostat E1 (SRTS-A01) | |
- integration: mqtt | |
manufacturer: Aqara | |
model: Smart radiator thermostat E1 | |
- integration: mqtt | |
manufacturer: Aqara | |
model: Aqara Smart Radiator thermostat E1 (SRTS-A01) | |
- integration: mqtt | |
manufacturer: Aqara | |
model: Aqara smart radiator thermostat E1 (SRTS-A01) | |
external_temperature_input_name: | |
name: TRV's Input Sensor Name | |
description: Enter a keyword or name used to identify the TRV’s number sensor entity-id, which sets the external temperature value. Defaults to 'external'. | |
selector: | |
text: | |
default: "external" | |
mode: single | |
max_exceeded: silent | |
variables: | |
aqara_trv_device: !input aqara_trv_device | |
external_temp_sensor: !input external_temp_sensor | |
external_temperature_input_name: !input external_temperature_input_name | |
trigger: | |
- trigger: state | |
entity_id: !input external_temp_sensor | |
action: | |
- variables: | |
aqara_trv_device_name: "{{ device_attr(aqara_trv_device, 'name') }}" | |
aqara_trv_select_entity: >- | |
{% set device_entities = device_entities(aqara_trv_device) %} | |
{{ expand(states['select']) | |
| selectattr('entity_id','in', device_entities) | |
| selectattr('attributes.options', 'contains', 'external') | |
| map(attribute='entity_id') | |
| first | |
}} | |
aqara_trv_number_entity: >- | |
{% set device_entities = device_entities(aqara_trv_device) %} | |
{{ expand(states['number']) | |
| selectattr('entity_id','in', device_entities) | |
| selectattr('entity_id', 'contains', external_temperature_input_name) | |
| map(attribute='entity_id') | |
| first | |
}} | |
- if: | |
- condition: template | |
value_template: >- | |
{{ is_state(external_temp_sensor, "unavailable") or is_state(external_temp_sensor, "unknown") }} | |
then: | |
- action: select.select_option | |
target: | |
entity_id: "{{aqara_trv_select_entity}}" | |
data: | |
option: internal | |
- action: system_log.write | |
data: | |
level: error | |
message: External temperature sensor unavailable | |
logger: Aqara TRV | |
- stop: External temperature sensor unavailable | |
- if: | |
- condition: template | |
value_template: "{{ not is_state(aqara_trv_select_entity, 'external')}}" | |
then: | |
- action: select.select_option | |
target: | |
entity_id: "{{aqara_trv_select_entity}}" | |
data: | |
option: external | |
- delay: | |
hours: 0 | |
minutes: 0 | |
seconds: 10 | |
milliseconds: 0 | |
- action: number.set_value | |
data: | |
value: >- | |
{{ (states(external_temp_sensor)|float(0)|round(1)) }} | |
target: | |
entity_id: "{{aqara_trv_number_entity}}" |
HI, Can two thermostats be connected to one temperature sensor?
@adamkorski yes
I updated ha and the blueprint to the newest version. When i add a new device, no Aquara TRV devices are in the list.
I updated ha and the blueprint to the newest version. When i add a new device, no Aquara TRV devices are in the list.
@Riemi001 Can you try it again. In the newest version it looks like the model string changed. I updated the blueprint
@adamkorski yes
do I have to do two automations or can I add two thermostats in one?
I updated ha and the blueprint to the newest version. When i add a new device, no Aquara TRV devices are in the list.
@Riemi001 Can you try it again. In the newest version it looks like the model string changed. I updated the blueprint
Thanks, it's working again now
I'd like to point out a fatal flaw with this blueprint, especially for people living in countries where heating is seriously expensive:
What happens if the external temperature sensor fails, and its state becomes unavailable
or unknown
?
In my observation, unavailable
or unknown
turns into 0
when cast/converted to float using {{ (states(external_temp_sensor)|float(0)|round(1)) }}
.
The TRV receives that 0 value, thinks its super cold and opens the valve to 100%, and it stays that way until fixed manually. That actually happened to me while I was out on vacation. That did hurt in my wallet.
Here's a way to fix it. By falling back to the TRV's internal sensor when the external one fails.
actions:
- variables:
# ...
- if:
- condition: template
value_template: >-
{{ is_state(external_temp_sensor, "unavailable") or is_state(external_temp_sensor, "unknown") }}
then:
- action: select.select_option
target:
entity_id: "{{aqara_trv_select_entity}}"
data:
option: internal
- stop: Temperature sensor failed.
# ...
I'd like to point out a fatal flaw with this blueprint, especially for people living in countries where heating is seriously expensive: What happens if the external temperature sensor fails, and its state becomes
unavailable
orunknown
?In my observation,
unavailable
orunknown
turns into0
when cast/converted to float using{{ (states(external_temp_sensor)|float(0)|round(1)) }}
. The TRV receives that 0 value, thinks its super cold and opens the valve to 100%, and it stays that way until fixed manually. That actually happened to me while I was out on vacation. That did hurt in my wallet.Here's a way to fix it. By falling back to the TRV's internal sensor when the external one fails.
actions: - variables: # ... - if: - condition: template value_template: >- {{ is_state(external_temp_sensor, "unavailable") or is_state(external_temp_sensor, "unknown") }} then: - action: select.select_option target: entity_id: "{{aqara_trv_select_entity}}" data: option: internal - stop: Temperature sensor failed. # ...
Thanks for pointing out this flaw- I updated the script.
Why is my thermostat not on? For some reason, the manufacturer is called LUMINARC and, accordingly, the model is also different, can you tell me how to fix it?