enviropi+ influx logger
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
#!/usr/bin/env python3 | |
import time | |
import datetime | |
from bme280 import BME280 | |
from ltr559 import LTR559 | |
from influxdb_client import InfluxDBClient, Point, WritePrecision | |
from influxdb_client.client.write_api import SYNCHRONOUS | |
try: | |
from smbus2 import SMBus | |
except ImportError: | |
from smbus import SMBus | |
# Corrects the relative humidity given a raw and corrected temperature reading | |
def correct_humidity(humidity, temperature, corr_temperature): | |
dewpoint = temperature - ((100 - humidity) / 5) | |
corr_humidity = 100 - (5 * (corr_temperature - dewpoint)) - 20 | |
return min(100, max(0, corr_humidity)) | |
# Set up the BME280 weather sensor | |
bus = SMBus(1) | |
bme280 = BME280(i2c_dev=bus) | |
bme280.setup(mode="forced") | |
time.sleep(5) | |
# Set up the light sensor | |
ltr559 = LTR559() | |
# InfluxDB client to write to | |
token = "****" | |
org = "****" | |
bucket = "****" | |
while True: | |
with InfluxDBClient(url="INFLUXDB_IP:8086", token=token, org=org) as client: | |
write_api = client.write_api(write_options=SYNCHRONOUS) | |
measurement = "indoors" | |
location = "bedroom" | |
# Read temperature (read twice, as the first reading can be artificially high) | |
temperature = bme280.get_temperature() | |
time.sleep(1) | |
temperature = bme280.get_temperature() | |
# Calculate corrected temperature | |
offset = 7.5 | |
corr_temperature = temperature - offset | |
w_temperature = measurement + ",location=" + location + " temperature=" + str(corr_temperature) | |
# Read humidity and correct it with the corrected temperature | |
humidity = bme280.get_humidity() | |
corr_humidity = correct_humidity(humidity, temperature, corr_temperature) | |
w_humidity = measurement + ",location=" + location + " humidity=" + str(corr_humidity) | |
# Read pressure | |
pressure = bme280.get_pressure() | |
w_pressure = measurement + ",location=" + location + " pressure=" + str(pressure) | |
# Read light | |
light = ltr559.get_lux() | |
w_light = measurement + ",location=" + location + " lux=" + str(light) | |
# Log the data | |
write_api.write(bucket, org, [w_temperature, w_humidity, w_pressure, w_light]) | |
client.close() | |
time.sleep(15) |