Created
April 22, 2017 23:39
-
-
Save kasparsd/1e164f0f9ad1a61448a96deb7bd0682c to your computer and use it in GitHub Desktop.
Sample Sevcon DCF file from https://endless-sphere.com/forums/viewtopic.php?f=10&t=36146&p=1011325&hilit=AC24ls.dcf#p1011325
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
[FileInfo] | |
FileName=C:/Users/Stealth/Desktop/AC24ls.dcf | |
FileVersion=1 | |
FileRevision=0 | |
EDSVersion=4.0 | |
Description=Gen4 (T,P,PS - slip)29 March 2012 13:20 | |
CreationTime=04:38PM | |
CreationDate=02-24-2015 | |
CreatedBy=Tech/Ops SEVCON Ltd | |
ModificationTime=04:38PM | |
ModificationDate=02-24-2015 | |
ModifiedBy=Tech/Ops SEVCON Ltd | |
[DeviceInfo] | |
VendorName=Tech/Ops SEVCON Ltd | |
ProductName=Gen4 | |
OrderCode=TODO | |
VendorNumber=0x0000001e | |
ProductNumber=0x07065037 | |
RevisionNumber=0x00010017 | |
BaudRate_10=0 | |
BaudRate_20=1 | |
BaudRate_50=1 | |
BaudRate_125=1 | |
BaudRate_250=1 | |
BaudRate_500=1 | |
BaudRate_800=0 | |
BaudRate_1000=1 | |
SimpleBootUpMaster=1 | |
SimpleBootUpSlave=1 | |
Granularity=64 | |
GroupMessaging=0 | |
DynamicChannelsSupported=0 | |
NrOfRXPDO=5 | |
NrOfTXPDO=5 | |
LSS_Supported=0 | |
[DeviceComissioning] | |
NodeID=1 | |
NodeName= | |
Baudrate=1000 | |
NetNumber= | |
NetworkName= | |
CANopenManager= | |
LSS_SerialNumber= | |
[Comments] | |
Lines=1 | |
Line1=A comment. | |
[DummyUsage] | |
Dummy0001=1 | |
Dummy0002=0 | |
Dummy0003=0 | |
Dummy0004=0 | |
Dummy0005=1 | |
Dummy0006=1 | |
Dummy0007=1 | |
[MandatoryObjects] | |
SupportedObjects=3 | |
1=0x1000 | |
2=0x1001 | |
3=0x1018 | |
[1000] | |
ParameterName=Device type | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=const | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0xFFFF0192 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DEVICE_TYPE | |
;SEVCONFIELD SECTION=CANOPEN_PROFILEEND | |
;SEVCONFIELD CATEGORY=MONITORING | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=2 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Type | |
;SEVCONFIELD BITMASK=0xFFFF | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=0xFFFF | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 402=Electric Drive | |
;SEVCONFIELD 401=Generic I/O | |
;SEVCONFIELD 419=Battery charger | |
;SEVCONFIELD 418=Battery module | |
;SEVCONFIELD 410 = inclinometer | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Additional data | |
;SEVCONFIELD BITMASK=0xFFFF0000 | |
;SEVCONFIELD BITSHIFT=0x10 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=0xFFFF | |
;SEVCONFIELD NUMBERFORMAT=BASE16 | |
[1001] | |
ParameterName=Error register | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=ERROR_REGISTER | |
;SEVCONFIELD SECTION=Emergency | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD CATEGORY=MONITORING | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=7 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Generic error | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Cleared | |
;SEVCONFIELD 1=Set | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Current error | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Cleared | |
;SEVCONFIELD 1=Set | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Voltage error | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Cleared | |
;SEVCONFIELD 1=Set | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Temperature error | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Cleared | |
;SEVCONFIELD 1=Set | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=Comms error | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Cleared | |
;SEVCONFIELD 1=Set | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Device Profile error | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Cleared | |
;SEVCONFIELD 1=Set | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=Manf specific error | |
;SEVCONFIELD BITMASK=0x80 | |
;SEVCONFIELD BITSHIFT=0x7 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Cleared | |
;SEVCONFIELD 1=Set | |
[1018] | |
SubNumber=5 | |
ObjectType=9 | |
ParameterName=Identity object | |
;SEVCONFIELD OBJECT=IDENTITY | |
;SEVCONFIELD SECTION=Identity | |
;SEVCONFIELD CATEGORY=MONITORING | |
[1018sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x04 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=4 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1018sub1] | |
ParameterName=Vendor ID | |
ParameterValue=0x0000001e | |
ObjectType=7 | |
DataType=7 | |
AccessType=const | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x0000001E | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1018sub2] | |
ParameterName=Product code | |
ParameterValue=0x07065037 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x0101503c | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1018sub3] | |
ParameterName=CANopen (Object Dictionary) revision | |
ParameterValue=0x00010017 | |
ObjectType=7 | |
DataType=7 | |
AccessType=const | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x00010001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1018sub4] | |
ParameterName=Serial number | |
ParameterValue=0x4d8baf41 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[OptionalObjects] | |
SupportedObjects=81 | |
1=0x1005 | |
2=0x1006 | |
3=0x1008 | |
4=0x1009 | |
5=0x100A | |
6=0x1010 | |
7=0x1011 | |
8=0x1014 | |
9=0x1016 | |
10=0x1017 | |
11=0x1200 | |
12=0x1201 | |
13=0x1202 | |
14=0x1203 | |
15=0x1280 | |
16=0x1281 | |
17=0x1282 | |
18=0x1283 | |
19=0x1284 | |
20=0x1285 | |
21=0x1286 | |
22=0x1287 | |
23=0x1400 | |
24=0x1401 | |
25=0x1402 | |
26=0x1403 | |
27=0x1404 | |
28=0x1600 | |
29=0x1601 | |
30=0x1602 | |
31=0x1603 | |
32=0x1604 | |
33=0x1800 | |
34=0x1801 | |
35=0x1802 | |
36=0x1803 | |
37=0x1804 | |
38=0x1A00 | |
39=0x1A01 | |
40=0x1A02 | |
41=0x1A03 | |
42=0x1A04 | |
43=0x6040 | |
44=0x6041 | |
45=0x6060 | |
46=0x6061 | |
47=0x6069 | |
48=0x606B | |
49=0x606C | |
50=0x6071 | |
51=0x6072 | |
52=0x6074 | |
53=0x6075 | |
54=0x6076 | |
55=0x6077 | |
56=0x6078 | |
57=0x6079 | |
58=0x607E | |
59=0x6080 | |
60=0x6083 | |
61=0x6086 | |
62=0x6087 | |
63=0x6088 | |
64=0x608B | |
65=0x608C | |
66=0x608D | |
67=0x608E | |
68=0x6090 | |
69=0x6095 | |
70=0x6096 | |
71=0x60F8 | |
72=0x60FF | |
73=0x6502 | |
74=0x67FF | |
75=0x6800 | |
76=0x6802 | |
77=0x6C01 | |
78=0x6C11 | |
79=0x6C43 | |
80=0x6C44 | |
81=0x6FFF | |
[1005] | |
ParameterName=Synchronization (SYNC) message COB-ID | |
ParameterValue=0x40000080 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x5FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x40000080 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=COBID_SYNC | |
;SEVCONFIELD SECTION=SYNCCOB | |
;SEVCONFIELD EEPROM=comm.sync_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1006] | |
ParameterName=Interval between SYNC messages (Communication cycle period) | |
ParameterValue=0x00004e20 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0x00002711 | |
HighLimit=0x01F3FC18 | |
PDOMapping=0 | |
DefaultValue=100000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.001 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD OBJECT=COMM_CYCLE_PERIOD | |
;SEVCONFIELD SECTION=SYNCCOB | |
;SEVCONFIELD EEPROM=comm.cycle_period | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1008] | |
ParameterName=Product name | |
ParameterValue=Gen4 (T,P,PS - slip)29 March 2012 13:20 | |
ObjectType=7 | |
DataType=9 | |
AccessType=const | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=MANU_DEVICE_NAME | |
;SEVCONFIELD SECTION=Identity | |
;SEVCONFIELD CATEGORY=MONITORING | |
[1009] | |
ParameterName=Hardware version | |
ParameterValue=0x00050004 | |
ObjectType=7 | |
DataType=9 | |
AccessType=const | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=MANU_HW_VERSION | |
;SEVCONFIELD SECTION=Identity | |
;SEVCONFIELD CATEGORY=MONITORING | |
[100A] | |
ParameterName=Software version | |
ParameterValue=UK0328.24 | |
ObjectType=7 | |
DataType=9 | |
AccessType=const | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=MANU_SW_VERSION | |
;SEVCONFIELD SECTION=Identity | |
;SEVCONFIELD CATEGORY=MONITORING | |
[1010] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=Store command | |
;SEVCONFIELD OBJECT=STORE | |
;SEVCONFIELD SECTION=CANOpenStore | |
;SEVCONFIELD CATEGORY=MONITORING | |
[1010sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1010sub1] | |
ParameterName=Save all parameters | |
ParameterValue=0x00000001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0x65766173 | |
HighLimit=0x65766173 | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0x0=Cancel | |
;SEVCONFIELD 0x65766173=Save to EEPROM | |
;SEVCONFIELD COMMS_TIMEOUT=10000 | |
[1011] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=Restore command | |
;SEVCONFIELD OBJECT=RESTORE | |
;SEVCONFIELD SECTION=CANOpenStore | |
;SEVCONFIELD CATEGORY=MONITORING | |
[1011sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1011sub1] | |
ParameterName=Load all parameters | |
ParameterValue=0x00000001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0x64616F6C | |
HighLimit=0x64616F6C | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0x0=Cancel | |
;SEVCONFIELD 0x64616F6C=Load from EEPROM | |
;SEVCONFIELD COMMS_TIMEOUT=10000 | |
[1014] | |
ParameterName=Emergency (EMCY) telegram COB-ID | |
ParameterValue=0x00000081 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x1FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=COBID_EMCY | |
;SEVCONFIELD SECTION=Emergency | |
;SEVCONFIELD EEPROM=comm.emergency_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1016] | |
SubNumber=8 | |
ObjectType=9 | |
ParameterName=Consumer heartbeat time | |
;SEVCONFIELD OBJECT=CONSUMER_HBEAT_TIME | |
;SEVCONFIELD SECTION=Heartbeat | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1016sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x07 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=7 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1016sub1] | |
ParameterName=Consumer heartbeat time for 1st node | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=comm.con_heartbeat_0 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=2 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=1st node- Heartbeat time | |
;SEVCONFIELD BITMASK=0xFFFF | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=0xFFFF | |
;SEVCONFIELD NUMBERFORMAT=BASE10 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=1st node- Node ID | |
;SEVCONFIELD BITMASK=0xFF0000 | |
;SEVCONFIELD BITSHIFT=0x10 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=127 | |
;SEVCONFIELD NUMBERFORMAT=BASE10 | |
;SEVCONFIELD | |
[1016sub2] | |
ParameterName=Consumer heartbeat time for 2nd node | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=comm.con_heartbeat_1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=2 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=2nd node- Heartbeat time | |
;SEVCONFIELD BITMASK=0xFFFF | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=0xFFFF | |
;SEVCONFIELD NUMBERFORMAT=BASE10 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=2nd node- Node ID | |
;SEVCONFIELD BITMASK=0xFF0000 | |
;SEVCONFIELD BITSHIFT=0x10 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=127 | |
;SEVCONFIELD NUMBERFORMAT=BASE10 | |
[1016sub3] | |
ParameterName=Consumer heartbeat time for 3rd node | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=comm.con_heartbeat_2 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=2 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=3rd node- Heartbeat time | |
;SEVCONFIELD BITMASK=0xFFFF | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=0xFFFF | |
;SEVCONFIELD NUMBERFORMAT=BASE10 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=3rd node- Node ID | |
;SEVCONFIELD BITMASK=0xFF0000 | |
;SEVCONFIELD BITSHIFT=0x10 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=127 | |
;SEVCONFIELD NUMBERFORMAT=BASE10 | |
[1016sub4] | |
ParameterName=Consumer heartbeat time for 4th node | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=comm.con_heartbeat_3 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=2 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=4th node- Heartbeat time | |
;SEVCONFIELD BITMASK=0xFFFF | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=0xFFFF | |
;SEVCONFIELD NUMBERFORMAT=BASE10 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=4th node- Node ID | |
;SEVCONFIELD BITMASK=0xFF0000 | |
;SEVCONFIELD BITSHIFT=0x10 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=127 | |
;SEVCONFIELD NUMBERFORMAT=BASE10 | |
[1016sub5] | |
ParameterName=Consumer heartbeat time for 5th node | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=comm.con_heartbeat_4 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=2 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=5th node- Heartbeat time | |
;SEVCONFIELD BITMASK=0xFFFF | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=0xFFFF | |
;SEVCONFIELD NUMBERFORMAT=BASE10 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=5th node- Node ID | |
;SEVCONFIELD BITMASK=0xFF0000 | |
;SEVCONFIELD BITSHIFT=0x10 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=127 | |
;SEVCONFIELD NUMBERFORMAT=BASE10 | |
[1016sub6] | |
ParameterName=Consumer heartbeat time for 6th node | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=comm.con_heartbeat_5 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=2 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=6th node- Heartbeat time | |
;SEVCONFIELD BITMASK=0xFFFF | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=0xFFFF | |
;SEVCONFIELD NUMBERFORMAT=BASE10 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=6th node- Node ID | |
;SEVCONFIELD BITMASK=0xFF0000 | |
;SEVCONFIELD BITSHIFT=0x10 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=127 | |
;SEVCONFIELD NUMBERFORMAT=BASE10 | |
[1016sub7] | |
ParameterName=Consumer heartbeat time for 7th node | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=comm.con_heartbeat_6 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=2 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=7th node- Heartbeat time | |
;SEVCONFIELD BITMASK=0xFFFF | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=0xFFFF | |
;SEVCONFIELD NUMBERFORMAT=BASE10 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=7th node- Node ID | |
;SEVCONFIELD BITMASK=0xFF0000 | |
;SEVCONFIELD BITSHIFT=0x10 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=127 | |
;SEVCONFIELD NUMBERFORMAT=BASE10 | |
[1017] | |
ParameterName=Producer heartbeat time | |
ParameterValue=0x01f4 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=500 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD OBJECT=PRODUCER_HBEAT_TIME | |
;SEVCONFIELD SECTION=Heartbeat | |
;SEVCONFIELD EEPROM=comm.heartbeat_reload | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1200] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Server SDO 1 (Default) parameters | |
;SEVCONFIELD OBJECT=SDO_PARAMETER | |
;SEVCONFIELD SECTION=ClientServerSDOs | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1200sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1200sub1] | |
ParameterName=COB-ID Client->Server (rx) | |
ParameterValue=0x00000601 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=$NODEID+0x600 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1200sub2] | |
ParameterName=COB-ID Server->Client (tx) | |
ParameterValue=0x00000581 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=$NODEID+0x580 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1201] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Server SDO 2 parameters | |
;SEVCONFIELD OBJECT=SDO_PARAMETER | |
;SEVCONFIELD SECTION=ClientServerSDOs | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1201sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1201sub1] | |
ParameterName=COB-ID Client->Server (rx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.ssdo_1.tx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1201sub2] | |
ParameterName=COB-ID Server->Client (tx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.ssdo_1.rx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1202] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Server SDO 3 parameters | |
;SEVCONFIELD OBJECT=SDO_PARAMETER | |
;SEVCONFIELD SECTION=ClientServerSDOs | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1202sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1202sub1] | |
ParameterName=COB-ID Client->Server (rx) | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.ssdo_2.tx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1202sub2] | |
ParameterName=COB-ID Server->Client (tx) | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.ssdo_2.rx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1203] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Server SDO 4 parameters | |
;SEVCONFIELD OBJECT=SDO_PARAMETER | |
;SEVCONFIELD SECTION=ClientServerSDOs | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1203sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1203sub1] | |
ParameterName=COB-ID Client->Server (rx) | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.ssdo_3.tx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1203sub2] | |
ParameterName=COB-ID Server->Client (tx) | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.ssdo_3.rx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1280] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Client SDO 1 parameters | |
;SEVCONFIELD OBJECT=SDO_PARAMETER | |
;SEVCONFIELD SECTION=ClientServerSDOs | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1280sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1280sub1] | |
ParameterName=COB-ID Client->Server (tx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_0.tx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1280sub2] | |
ParameterName=COB-ID Server->Client (rx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_0.rx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1280sub3] | |
ParameterName=SDO server Node ID | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=0x7F | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_0.node_id | |
[1281] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Client SDO 2 parameters | |
;SEVCONFIELD OBJECT=SDO_PARAMETER | |
;SEVCONFIELD SECTION=ClientServerSDOs | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1281sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1281sub1] | |
ParameterName=COB-ID Client->Server (tx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_1.tx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1281sub2] | |
ParameterName=COB-ID Server->Client (rx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_1.rx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1281sub3] | |
ParameterName=SDO server Node ID | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=0x7F | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_1.node_id | |
[1282] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Client SDO 3 parameters | |
;SEVCONFIELD OBJECT=SDO_PARAMETER | |
;SEVCONFIELD SECTION=ClientServerSDOs | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1282sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1282sub1] | |
ParameterName=COB-ID Client->Server (tx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_2.tx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1282sub2] | |
ParameterName=COB-ID Server->Client (rx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_2.rx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1282sub3] | |
ParameterName=SDO server Node ID | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=0x7F | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_2.node_id | |
[1283] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Client SDO 4 parameters | |
;SEVCONFIELD OBJECT=SDO_PARAMETER | |
;SEVCONFIELD SECTION=ClientServerSDOs | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1283sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1283sub1] | |
ParameterName=COB-ID Client->Server (tx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_3.tx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1283sub2] | |
ParameterName=COB-ID Server->Client (rx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_3.rx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1283sub3] | |
ParameterName=SDO server Node ID | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=0x7F | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_3.node_id | |
[1284] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Client SDO 5 parameters | |
;SEVCONFIELD OBJECT=SDO_PARAMETER | |
;SEVCONFIELD SECTION=ClientServerSDOs | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1284sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1284sub1] | |
ParameterName=COB-ID Client->Server (tx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_4.tx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1284sub2] | |
ParameterName=COB-ID Server->Client (rx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_4.rx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1284sub3] | |
ParameterName=SDO server Node ID | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=0x7F | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_4.node_id | |
[1285] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Client SDO 6 parameters | |
;SEVCONFIELD OBJECT=SDO_PARAMETER | |
;SEVCONFIELD SECTION=ClientServerSDOs | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1285sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1285sub1] | |
ParameterName=COB-ID Client->Server (tx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_5.tx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1285sub2] | |
ParameterName=COB-ID Server->Client (rx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_5.rx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1285sub3] | |
ParameterName=SDO server Node ID | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=0x7F | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_5.node_id | |
[1286] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Client SDO 7 parameters | |
;SEVCONFIELD OBJECT=SDO_PARAMETER | |
;SEVCONFIELD SECTION=ClientServerSDOs | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1286sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1286sub1] | |
ParameterName=COB-ID Client->Server (tx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_6.tx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1286sub2] | |
ParameterName=COB-ID Server->Client (rx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_6.rx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1286sub3] | |
ParameterName=SDO server Node ID | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=0x7F | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_6.node_id | |
[1287] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Client SDO 8 parameters | |
;SEVCONFIELD OBJECT=SDO_PARAMETER | |
;SEVCONFIELD SECTION=ClientServerSDOs | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1287sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1287sub1] | |
ParameterName=COB-ID Client->Server (tx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_7.tx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1287sub2] | |
ParameterName=COB-ID Server->Client (rx) | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_7.rx_sdo_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1287sub3] | |
ParameterName=SDO server Node ID | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=0x7F | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.csdo_7.node_id | |
[1400] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Receive PDO communication parameters 1 | |
;SEVCONFIELD OBJECT=PDO_COMMUNICATION | |
;SEVCONFIELD SECTION=RECEIVEPDO1 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1400sub0] | |
ParameterName=Largest sub-index supported | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1400sub1] | |
ParameterName=COB-ID used by PDO | |
ParameterValue=0x00000200 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0x00000001 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x80000182 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_0.cob_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1400sub2] | |
ParameterName=Transmission type | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=255 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_0.trans_type | |
[1401] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Receive PDO communication parameters 2 | |
;SEVCONFIELD OBJECT=PDO_COMMUNICATION | |
;SEVCONFIELD SECTION=RECEIVEPDO2 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1401sub0] | |
ParameterName=Largest sub-index supported | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1401sub1] | |
ParameterName=COB-ID used by PDO | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0x00000001 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x80000282 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_1.cob_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1401sub2] | |
ParameterName=Transmission type | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=255 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_1.trans_type | |
[1402] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Receive PDO communication parameters 3 | |
;SEVCONFIELD OBJECT=PDO_COMMUNICATION | |
;SEVCONFIELD SECTION=RECEIVEPDO3 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1402sub0] | |
ParameterName=Largest sub-index supported | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1402sub1] | |
ParameterName=COB-ID used by PDO | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0x00000001 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x80000382 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_2.cob_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1402sub2] | |
ParameterName=Transmission type | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=255 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_2.trans_type | |
[1403] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Receive PDO communication parameters 4 | |
;SEVCONFIELD OBJECT=PDO_COMMUNICATION | |
;SEVCONFIELD SECTION=RECEIVEPDO4 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1403sub0] | |
ParameterName=Largest sub-index supported | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1403sub1] | |
ParameterName=COB-ID used by PDO | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0x00000001 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x80000183 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_3.cob_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1403sub2] | |
ParameterName=Transmission type | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=255 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_3.trans_type | |
[1404] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Receive PDO communication parameters 5 | |
;SEVCONFIELD OBJECT=PDO_COMMUNICATION | |
;SEVCONFIELD SECTION=RECEIVEPDO5 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1404sub0] | |
ParameterName=Largest sub-index supported | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1404sub1] | |
ParameterName=COB-ID used by PDO | |
ParameterValue=0x80000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0x00000001 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x80000283 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_4.cob_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1404sub2] | |
ParameterName=Transmission type | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=255 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_4.trans_type | |
[1600] | |
SubNumber=9 | |
ObjectType=9 | |
ParameterName=Receive PDO mapping parameters 1 | |
;SEVCONFIELD OBJECT=RPDO_MAPPING | |
;SEVCONFIELD SECTION=RECEIVEPDO1 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1600sub0] | |
ParameterName=Number of mapped objects | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.num_objects | |
[1600sub1] | |
ParameterName=Map 1 | |
ParameterValue=0x21210001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x20210210 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[0] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1600sub2] | |
ParameterName=Map 2 | |
ParameterValue=0x21220001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x20210420 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[1] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1600sub3] | |
ParameterName=Map 3 | |
ParameterValue=0x21220001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x20210610 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[2] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1600sub4] | |
ParameterName=Map 4 | |
ParameterValue=0x21230001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C110410 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[3] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1600sub5] | |
ParameterName=Map 5 | |
ParameterValue=0x21240001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C110110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[4] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1600sub6] | |
ParameterName=Map 6 | |
ParameterValue=0x21250001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C110110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[5] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1600sub7] | |
ParameterName=Map 7 | |
ParameterValue=0x21240001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C110110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[6] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1600sub8] | |
ParameterName=Map 8 | |
ParameterValue=0x21250001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C110110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[7] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1601] | |
SubNumber=9 | |
ObjectType=9 | |
ParameterName=Receive PDO mapping parameters 2 | |
;SEVCONFIELD OBJECT=RPDO_MAPPING | |
;SEVCONFIELD SECTION=RECEIVEPDO2 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1601sub0] | |
ParameterName=Number of mapped objects | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=8 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.num_objects | |
[1601sub1] | |
ParameterName=Map 1 | |
ParameterValue=0x21210001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x21200001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[0] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1601sub2] | |
ParameterName=Map 2 | |
ParameterValue=0x21220001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x21210001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[1] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1601sub3] | |
ParameterName=Map 3 | |
ParameterValue=0x21230001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x21220001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[2] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1601sub4] | |
ParameterName=Map 4 | |
ParameterValue=0x21240001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x21230001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[3] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1601sub5] | |
ParameterName=Map 5 | |
ParameterValue=0x21250001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x21240001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[4] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1601sub6] | |
ParameterName=Map 6 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x21250001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[5] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1601sub7] | |
ParameterName=Map 7 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x21260001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[6] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1601sub8] | |
ParameterName=Map 8 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x21270001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[7] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1602] | |
SubNumber=9 | |
ObjectType=9 | |
ParameterName=Receive PDO mapping parameters 3 | |
;SEVCONFIELD OBJECT=RPDO_MAPPING | |
;SEVCONFIELD SECTION=RECEIVEPDO3 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1602sub0] | |
ParameterName=Number of mapped objects | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=4 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.num_objects | |
[1602sub1] | |
ParameterName=Map 1 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x22200010 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[0] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1602sub2] | |
ParameterName=Map 2 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x22210010 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[1] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1602sub3] | |
ParameterName=Map 3 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x22220010 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[2] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1602sub4] | |
ParameterName=Map 4 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x22230010 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[3] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1602sub5] | |
ParameterName=Map 5 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C110110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[4] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1602sub6] | |
ParameterName=Map 6 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C110110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[5] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1602sub7] | |
ParameterName=Map 7 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C110110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[6] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1602sub8] | |
ParameterName=Map 8 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C110110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[7] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1603] | |
SubNumber=9 | |
ObjectType=9 | |
ParameterName=Receive PDO mapping parameters 4 | |
;SEVCONFIELD OBJECT=RPDO_MAPPING | |
;SEVCONFIELD SECTION=RECEIVEPDO4 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1603sub0] | |
ParameterName=Number of mapped objects | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.num_objects | |
[1603sub1] | |
ParameterName=Map 1 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x20400210 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[0] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1603sub2] | |
ParameterName=Map 2 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x20400420 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[1] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1603sub3] | |
ParameterName=Map 3 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x20400610 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[2] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1603sub4] | |
ParameterName=Map 4 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C110110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[3] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1603sub5] | |
ParameterName=Map 5 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C110110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[4] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1603sub6] | |
ParameterName=Map 6 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C110110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[5] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1603sub7] | |
ParameterName=Map 7 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C110110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[6] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1603sub8] | |
ParameterName=Map 8 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C110110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[7] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1604] | |
SubNumber=9 | |
ObjectType=9 | |
ParameterName=Receive PDO mapping parameters 5 | |
;SEVCONFIELD OBJECT=RPDO_MAPPING | |
;SEVCONFIELD SECTION=RECEIVEPDO5 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1604sub0] | |
ParameterName=Number of mapped objects | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=7 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.num_objects | |
[1604sub1] | |
ParameterName=Map 1 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x21400001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[0] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1604sub2] | |
ParameterName=Map 2 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x21410001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[1] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1604sub3] | |
ParameterName=Map 3 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x21420001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[2] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1604sub4] | |
ParameterName=Map 4 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x21430001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[3] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1604sub5] | |
ParameterName=Map 5 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x21440001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[4] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1604sub6] | |
ParameterName=Map 6 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x21450001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[5] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1604sub7] | |
ParameterName=Map 7 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x21460001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[6] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1604sub8] | |
ParameterName=Map 8 | |
ParameterValue=0x6c110110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C110110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[7] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1800] | |
SubNumber=5 | |
ObjectType=9 | |
ParameterName=Transmit PDO communication parameters 1 | |
;SEVCONFIELD OBJECT=PDO_COMMUNICATION | |
;SEVCONFIELD SECTION=TRANSMITPDO1 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1800sub0] | |
ParameterName=Largest sub-index supported | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=5 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1800sub1] | |
ParameterName=COB-ID used by PDO | |
ParameterValue=0x00000310 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0x00000001 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x80000202 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_0.cob_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1800sub2] | |
ParameterName=Transmission type | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_0.trans_type | |
[1800sub3] | |
ParameterName=Inhibit time | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_0.inhibit_time | |
[1800sub5] | |
ParameterName=Event timer | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_0.w_event_timer_reload | |
[1801] | |
SubNumber=5 | |
ObjectType=9 | |
ParameterName=Transmit PDO communication parameters 2 | |
;SEVCONFIELD OBJECT=PDO_COMMUNICATION | |
;SEVCONFIELD SECTION=TRANSMITPDO2 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1801sub0] | |
ParameterName=Largest sub-index supported | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=5 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1801sub1] | |
ParameterName=COB-ID used by PDO | |
ParameterValue=0x00000259 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0x00000001 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x80000302 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_1.cob_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1801sub2] | |
ParameterName=Transmission type | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0xFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_1.trans_type | |
[1801sub3] | |
ParameterName=Inhibit time | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_1.inhibit_time | |
[1801sub5] | |
ParameterName=Event timer | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_1.w_event_timer_reload | |
[1802] | |
SubNumber=5 | |
ObjectType=9 | |
ParameterName=Transmit PDO communication parameters 3 | |
;SEVCONFIELD OBJECT=PDO_COMMUNICATION | |
;SEVCONFIELD SECTION=TRANSMITPDO3 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1802sub0] | |
ParameterName=Largest sub-index supported | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=5 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1802sub1] | |
ParameterName=COB-ID used by PDO | |
ParameterValue=0x00000132 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0x00000001 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x80000402 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_2.cob_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1802sub2] | |
ParameterName=Transmission type | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0xFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_2.trans_type | |
[1802sub3] | |
ParameterName=Inhibit time | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_2.inhibit_time | |
[1802sub5] | |
ParameterName=Event timer | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_2.w_event_timer_reload | |
[1803] | |
SubNumber=5 | |
ObjectType=9 | |
ParameterName=Transmit PDO communication parameters 4 | |
;SEVCONFIELD OBJECT=PDO_COMMUNICATION | |
;SEVCONFIELD SECTION=TRANSMITPDO4 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1803sub0] | |
ParameterName=Largest sub-index supported | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=5 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1803sub1] | |
ParameterName=COB-ID used by PDO | |
ParameterValue=0x00000477 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0x00000001 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x80000203 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_3.cob_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1803sub2] | |
ParameterName=Transmission type | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_3.trans_type | |
[1803sub3] | |
ParameterName=Inhibit time | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_3.inhibit_time | |
[1803sub5] | |
ParameterName=Event timer | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_3.w_event_timer_reload | |
[1804] | |
SubNumber=5 | |
ObjectType=9 | |
ParameterName=Transmit PDO communication parameters 5 | |
;SEVCONFIELD OBJECT=PDO_COMMUNICATION | |
;SEVCONFIELD SECTION=TRANSMITPDO5 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1804sub0] | |
ParameterName=Largest sub-index supported | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=5 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[1804sub1] | |
ParameterName=COB-ID used by PDO | |
ParameterValue=0x00000140 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0x00000001 | |
HighLimit=0x9FFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x80000303 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_4.cob_id | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1804sub2] | |
ParameterName=Transmission type | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0xFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_4.trans_type | |
[1804sub3] | |
ParameterName=Inhibit time | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_4.inhibit_time | |
[1804sub5] | |
ParameterName=Event timer | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_4.w_event_timer_reload | |
[1A00] | |
SubNumber=9 | |
ObjectType=9 | |
ParameterName=Transmit PDO mapping parameters 1 | |
;SEVCONFIELD OBJECT=TPDO_MAPPING | |
;SEVCONFIELD SECTION=TRANSMITPDO1 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1A00sub0] | |
ParameterName=Number of mapped objects | |
ParameterValue=0x04 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.num_objects | |
[1A00sub1] | |
ParameterName=Map 1 | |
ParameterValue=0x46000510 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x20210110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[0] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A00sub2] | |
ParameterName=Map 2 | |
ParameterValue=0x46000610 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x20210320 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[1] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A00sub3] | |
ParameterName=Map 3 | |
ParameterValue=0x46000710 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x20210510 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[2] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A00sub4] | |
ParameterName=Map 4 | |
ParameterValue=0x46000810 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[3] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A00sub5] | |
ParameterName=Map 5 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[4] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A00sub6] | |
ParameterName=Map 6 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[5] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A00sub7] | |
ParameterName=Map 7 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[6] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A00sub8] | |
ParameterName=Map 8 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[7] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A01] | |
SubNumber=9 | |
ObjectType=9 | |
ParameterName=Transmit PDO mapping parameters 2 | |
;SEVCONFIELD OBJECT=TPDO_MAPPING | |
;SEVCONFIELD SECTION=TRANSMITPDO2 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1A01sub0] | |
ParameterName=Number of mapped objects | |
ParameterValue=0x04 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.num_objects | |
[1A01sub1] | |
ParameterName=Map 1 | |
ParameterValue=0x46000910 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x23200001 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[0] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A01sub2] | |
ParameterName=Map 2 | |
ParameterValue=0x46000a10 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C010210 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[1] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A01sub3] | |
ParameterName=Map 3 | |
ParameterValue=0x46000b10 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C010310 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[2] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A01sub4] | |
ParameterName=Map 4 | |
ParameterValue=0x60780010 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x6C010410 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[3] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A01sub5] | |
ParameterName=Map 5 | |
ParameterValue=0x60410010 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[4] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A01sub6] | |
ParameterName=Map 6 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[5] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A01sub7] | |
ParameterName=Map 7 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[6] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A01sub8] | |
ParameterName=Map 8 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[7] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A02] | |
SubNumber=9 | |
ObjectType=9 | |
ParameterName=Transmit PDO mapping parameters 3 | |
;SEVCONFIELD OBJECT=TPDO_MAPPING | |
;SEVCONFIELD SECTION=TRANSMITPDO3 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1A02sub0] | |
ParameterName=Number of mapped objects | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=4 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.num_objects | |
[1A02sub1] | |
ParameterName=Map 1 | |
ParameterValue=0x51000310 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x24000010 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[0] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A02sub2] | |
ParameterName=Map 2 | |
ParameterValue=0x51000408 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x24010010 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[1] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A02sub3] | |
ParameterName=Map 3 | |
ParameterValue=0x51000210 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x24200010 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[2] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A02sub4] | |
ParameterName=Map 4 | |
ParameterValue=0x60710010 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x24210010 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[3] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A02sub5] | |
ParameterName=Map 5 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[4] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A02sub6] | |
ParameterName=Map 6 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[5] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A02sub7] | |
ParameterName=Map 7 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[6] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A02sub8] | |
ParameterName=Map 8 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[7] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A03] | |
SubNumber=9 | |
ObjectType=9 | |
ParameterName=Transmit PDO mapping parameters 4 | |
;SEVCONFIELD OBJECT=TPDO_MAPPING | |
;SEVCONFIELD SECTION=TRANSMITPDO4 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1A03sub0] | |
ParameterName=Number of mapped objects | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.num_objects | |
[1A03sub1] | |
ParameterName=Map 1 | |
ParameterValue=0x20200320 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x20400110 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[0] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A03sub2] | |
ParameterName=Map 2 | |
ParameterValue=0x606c0020 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x20400320 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[1] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A03sub3] | |
ParameterName=Map 3 | |
ParameterValue=0x46000610 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x20400510 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[2] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A03sub4] | |
ParameterName=Map 4 | |
ParameterValue=0x46000710 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[3] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A03sub5] | |
ParameterName=Map 5 | |
ParameterValue=0x27200208 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[4] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A03sub6] | |
ParameterName=Map 6 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[5] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A03sub7] | |
ParameterName=Map 7 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[6] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A03sub8] | |
ParameterName=Map 8 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[7] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A04] | |
SubNumber=9 | |
ObjectType=9 | |
ParameterName=Transmit PDO mapping parameters 5 | |
;SEVCONFIELD OBJECT=TPDO_MAPPING | |
;SEVCONFIELD SECTION=TRANSMITPDO5 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[1A04sub0] | |
ParameterName=Number of mapped objects | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.num_objects | |
[1A04sub1] | |
ParameterName=Map 1 | |
ParameterValue=0x46000110 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[0] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A04sub2] | |
ParameterName=Map 2 | |
ParameterValue=0x60770010 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[1] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A04sub3] | |
ParameterName=Map 3 | |
ParameterValue=0x26200010 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[2] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A04sub4] | |
ParameterName=Map 4 | |
ParameterValue=0x21210001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[3] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A04sub5] | |
ParameterName=Map 5 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[4] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A04sub6] | |
ParameterName=Map 6 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[5] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A04sub7] | |
ParameterName=Map 7 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[6] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[1A04sub8] | |
ParameterName=Map 8 | |
ParameterValue=0x68000108 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x68000108 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[7] | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[6040] | |
ParameterName=controlword | |
ParameterValue=0x8007 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=CONTROLWORD | |
;SEVCONFIELD SECTION=MOTOR1CONTROL | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD CATEGORY=MONITORING | |
[6041] | |
ParameterName=statusword | |
ParameterValue=0x0840 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=STATUSWORD | |
;SEVCONFIELD SECTION=Motor1Status | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD CATEGORY=MONITORING | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=7 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Device status | |
;SEVCONFIELD BITMASK=0x6F | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=0x6F | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0x20=not ready to switch on | |
;SEVCONFIELD 0x0=not ready to switch on | |
;SEVCONFIELD 0x40=switch on disabled | |
;SEVCONFIELD 0x60=switch on disabled | |
;SEVCONFIELD 0x21=ready to switch on | |
;SEVCONFIELD 0x31=ready to switch on | |
;SEVCONFIELD 0x23=switched on | |
;SEVCONFIELD 0x33=switched on | |
;SEVCONFIELD 0x27=Operation enabled | |
;SEVCONFIELD 0x37=Operation enabled | |
;SEVCONFIELD 0x7=Quick stop active | |
;SEVCONFIELD 0x17=Quick stop active | |
;SEVCONFIELD 0xF= Fault reaction active | |
;SEVCONFIELD 0x2F=Fault reaction active | |
;SEVCONFIELD 0x8=Fault | |
;SEVCONFIELD 0x28=Fault | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Voltage enabled | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=disabled | |
;SEVCONFIELD 1=enabled | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Warning | |
;SEVCONFIELD BITMASK=0x80 | |
;SEVCONFIELD BITSHIFT=0x7 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=cleared | |
;SEVCONFIELD 1=set | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Remote | |
;SEVCONFIELD BITMASK=0x200 | |
;SEVCONFIELD BITSHIFT=0x9 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=disabled | |
;SEVCONFIELD 1=enabled | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=Target reached | |
;SEVCONFIELD BITMASK=0x400 | |
;SEVCONFIELD BITSHIFT=0xA | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=not reached | |
;SEVCONFIELD 1=reached | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Internal limit active | |
;SEVCONFIELD BITMASK=0x800 | |
;SEVCONFIELD BITSHIFT=0xB | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=cleared | |
;SEVCONFIELD 1=active | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=Operation mode specific | |
;SEVCONFIELD BITMASK=0x3000 | |
;SEVCONFIELD BITSHIFT=0xC | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD | |
[6060] | |
ParameterName=Mode of operation selection | |
ParameterValue=0x04 | |
ObjectType=7 | |
DataType=2 | |
AccessType=rw | |
LowLimit=3 | |
HighLimit=4 | |
PDOMapping=0 | |
DefaultValue=4 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=MODE_OF_OPERATION | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD EEPROM=motor_0.mode | |
;SEVCONFIELD NUMBER_FORMAT=3 | |
;SEVCONFIELD 3=speed | |
;SEVCONFIELD 4=torque | |
;SEVCONFIELD 5=voltage | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[6061] | |
ParameterName=Operational mode | |
ParameterValue=0x04 | |
ObjectType=7 | |
DataType=2 | |
AccessType=ro | |
LowLimit=3 | |
HighLimit=4 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=MODE_OF_OPERATION_DISPLAY | |
;SEVCONFIELD SECTION=Motor1Status | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 3=speed | |
;SEVCONFIELD 4=torque | |
;SEVCONFIELD CATEGORY=MONITORING | |
[6069] | |
ParameterName=Encoder count | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=ro | |
LowLimit=-400000 | |
HighLimit=400000 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=Inc/s | |
;SEVCONFIELD OBJECT=VELOCITY_SENSOR_ACTUAL | |
;SEVCONFIELD SECTION=Motor1Status | |
;SEVCONFIELD CATEGORY=MONITORING | |
[606B] | |
ParameterName=Velocity demand | |
ParameterValue=0x0000003d | |
ObjectType=7 | |
DataType=4 | |
AccessType=ro | |
LowLimit=-20000 | |
HighLimit=20000 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD OBJECT=VELOCITY_DEMAND | |
;SEVCONFIELD SECTION=Motor1Status | |
;SEVCONFIELD CATEGORY=MONITORING | |
[606C] | |
ParameterName=Velocity | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=ro | |
LowLimit=-20000 | |
HighLimit=20000 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD OBJECT=VELOCITY_ACTUAL | |
;SEVCONFIELD SECTION=Motor1Status | |
;SEVCONFIELD CATEGORY=MONITORING | |
[6071] | |
ParameterName=Target torque | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-1000 | |
HighLimit=1000 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% of peak | |
;SEVCONFIELD OBJECT=TARGET_TORQUE | |
;SEVCONFIELD SECTION=MOTOR1CONTROL | |
;SEVCONFIELD SOFT_LOW=-32768 | |
;SEVCONFIELD SOFT_HIGH=32767 | |
;SEVCONFIELD CATEGORY=MONITORING | |
[6072] | |
ParameterName=Maximum torque | |
ParameterValue=0x03e8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=1 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% of peak | |
;SEVCONFIELD OBJECT=MAX_TORQUE | |
;SEVCONFIELD SECTION=MOTOR1CONTROL | |
;SEVCONFIELD EEPROM=motor_0.maximum_torque | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[6074] | |
ParameterName=Torque demand | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-1000 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% of peak | |
;SEVCONFIELD OBJECT=TORQUE_DEMAND | |
;SEVCONFIELD SECTION=Motor1Status | |
;SEVCONFIELD CATEGORY=MONITORING | |
[6075] | |
ParameterName=Current limit | |
ParameterValue=0x00086470 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=700000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.001 | |
;SEVCONFIELD UNITS=A(RMS) | |
;SEVCONFIELD OBJECT=MOTOR_RATED_TORQUE | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD EEPROM=motor_0.rated_current | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[6076] | |
ParameterName=Peak torque | |
ParameterValue=0x00014ff0 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=2000000 | |
PDOMapping=0 | |
DefaultValue=25000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.001 | |
;SEVCONFIELD UNITS=Nm | |
;SEVCONFIELD OBJECT=MOTOR_RATED_TORQUE | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD EEPROM=motor_0.rated_torque | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[6077] | |
ParameterName=Torque | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-1000 | |
HighLimit=1000 | |
PDOMapping=1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% of peak | |
;SEVCONFIELD OBJECT=TORQUE_ACTUAL | |
;SEVCONFIELD SECTION=Motor1Status | |
;SEVCONFIELD CATEGORY=MONITORING | |
[6078] | |
ParameterName=Current | |
ParameterValue=0x0001 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-1000 | |
HighLimit=1000 | |
PDOMapping=1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=A(RMS) | |
;SEVCONFIELD OBJECT=TORQUE_ACTUAL | |
;SEVCONFIELD SECTION=Motor1Status | |
;SEVCONFIELD CATEGORY=MONITORING | |
[6079] | |
ParameterName=Capacitor Voltage | |
ParameterValue=0x000000ac | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=400000 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.001 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD OBJECT=DC_LINK_V | |
;SEVCONFIELD SECTION=Motor1Status | |
;SEVCONFIELD CATEGORY=MONITORING | |
[607E] | |
ParameterName=Encoder Polarity | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=64 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=ENCODER_POLARITY | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD EEPROM=motor_0.encoder_polarity | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=normal | |
;SEVCONFIELD 64=inverted | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[6080] | |
ParameterName=Maximum motor speed | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=1 | |
DefaultValue=2500 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD OBJECT=MAX_MOTOR_SPEED | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD EEPROM=motor_0.maximum_motor_speed | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[6083] | |
ParameterName=Maximum acceleration rate | |
ParameterValue=0x000003e8 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0x7FFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=rpm/s | |
;SEVCONFIELD OBJECT=PROFILE_ACCELERATION | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD EEPROM=motor_0.profile_accel | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[6086] | |
ParameterName=Motion profile type | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=MOTION_PROFILE_TYPE | |
;SEVCONFIELD SECTION=MOTOR1STATUS | |
;SEVCONFIELD NUMBER_FORMAT=1 | |
;SEVCONFIELD 0=Linear | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[6087] | |
ParameterName=Torque slope | |
ParameterValue=0x0000ffff | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=40000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% rated/s | |
;SEVCONFIELD OBJECT=TORQUE_SLOPE | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD EEPROM=motor_0.trq_slope | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[6088] | |
ParameterName=Torque profile type | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=TORQUE_PROFILE_TYPE | |
;SEVCONFIELD SECTION=MOTOR1STATUS | |
;SEVCONFIELD NUMBER_FORMAT=1 | |
;SEVCONFIELD 0=Linear | |
;SEVCONFIELD CATEGORY=MONITORING | |
[608B] | |
ParameterName=Velocity notation index | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=2 | |
AccessType=ro | |
LowLimit=-128 | |
HighLimit=127 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=VELOCITY_NOTATION_INDEX | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD CATEGORY=MONITORING | |
[608C] | |
ParameterName=Velocity dimension index | |
ParameterValue=0xa4 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0xA4 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=VELOCITY_DIMENSION_INDEX | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD CATEGORY=MONITORING | |
[608D] | |
ParameterName=Acceleration notation index | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=2 | |
AccessType=ro | |
LowLimit=-128 | |
HighLimit=127 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=ACCELERATION_NOTATION_INDEX | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD CATEGORY=MONITORING | |
[608E] | |
ParameterName=Acceleration dimension index | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=ACCELERATION_DIMENSION_INDEX | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD CATEGORY=MONITORING | |
[6090] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Encoder resolution | |
;SEVCONFIELD OBJECT=ENCODER_RESOLUTION | |
;SEVCONFIELD SECTION=ENCODERCONFIG | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[6090sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[6090sub1] | |
ParameterName=Pulses per revolution | |
ParameterValue=0x00000050 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=4294967295 | |
PDOMapping=0 | |
DefaultValue=64 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=PPR | |
;SEVCONFIELD EEPROM=motor_0.encoder_incs_per_second | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[6090sub2] | |
ParameterName=Motor revolutions per second | |
ParameterValue=0x00000001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=4294967295 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPS | |
;SEVCONFIELD EEPROM=motor_0.encoder_revs_per_second | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[6095] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Velocity factor 1 | |
;SEVCONFIELD OBJECT=VELOCITY_FACTOR1 | |
;SEVCONFIELD SECTION=MOTOR1STATUS | |
;SEVCONFIELD CATEGORY=MONITORING | |
[6095sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[6095sub1] | |
ParameterName=Numerator | |
ParameterValue=0x00000001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=100 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[6095sub2] | |
ParameterName=Denominator | |
ParameterValue=0x00000001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=100 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[6096] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Velocity factor 2 | |
;SEVCONFIELD OBJECT=VELOCITY_FACTOR2 | |
;SEVCONFIELD SECTION=MOTOR1STATUS | |
;SEVCONFIELD CATEGORY=MONITORING | |
[6096sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[6096sub1] | |
ParameterName=Numerator | |
ParameterValue=0x00000001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=100 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[6096sub2] | |
ParameterName=Denominator | |
ParameterValue=0x00000001 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=100 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[60F8] | |
ParameterName=Maximum Motor Slippage | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=rw | |
LowLimit=-804248 | |
HighLimit=804248 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=6.21698996452716E-04 | |
;SEVCONFIELD UNITS=rads/s | |
;SEVCONFIELD OBJECT=MAX_SLIPPAGE | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD EEPROM=motor_0.max_slippage | |
;SEVCONFIELD SOFT_HIGH=2147483647 | |
;SEVCONFIELD SOFT_LOW=-2147483648 | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[60FF] | |
ParameterName=Target speed | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=rww | |
LowLimit=-20000 | |
HighLimit=20000 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=rpm | |
;SEVCONFIELD OBJECT=TARGET_VELOCITY | |
;SEVCONFIELD SECTION=MOTOR1CONTROL | |
;SEVCONFIELD SOFT_HIGH=2147483647 | |
;SEVCONFIELD SOFT_LOW=-2147483648 | |
;SEVCONFIELD CATEGORY=MONITORING | |
[6502] | |
ParameterName=Supported drive modes | |
ParameterValue=0x0000000c | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x0000000C | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=SUPPORTED_DRIVE_MODES | |
;SEVCONFIELD SECTION=MOTOR1STATUS | |
;SEVCONFIELD CATEGORY=MONITORING | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=2 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Drive modes- Torque | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=not supported | |
;SEVCONFIELD 1=supported | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Drive modes- Speed | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=not supported | |
;SEVCONFIELD 1=supported | |
[67FF] | |
ParameterName=Device type | |
ParameterValue=0x00010192 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x00010192 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DEVICE_TYPE | |
;SEVCONFIELD SECTION=CANOPEN_PROFILEEND | |
;SEVCONFIELD CATEGORY=MONITORING | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=2 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Type | |
;SEVCONFIELD BITMASK=0xFFFF | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=0xFFFF | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 402=Electric Drive | |
;SEVCONFIELD 401=Generic I/O | |
;SEVCONFIELD 419=Battery charger | |
;SEVCONFIELD 418=Battery module | |
;SEVCONFIELD 410 = inclinometer | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Additional data | |
;SEVCONFIELD BITMASK=0xFFFF0000 | |
;SEVCONFIELD BITSHIFT=0x10 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=0xFFFF | |
;SEVCONFIELD NUMBERFORMAT=BASE16 | |
[6800] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Digital Input states | |
;SEVCONFIELD OBJECT=READ_DIG_IN_8 | |
;SEVCONFIELD SECTION=DIStatus | |
;SEVCONFIELD CATEGORY=MONITORING | |
[6800sub0] | |
ParameterName=Number of digital input bytes | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[6800sub1] | |
ParameterName=Digital Inputs 1..8 states | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[6800sub2] | |
ParameterName=Digital Inputs 9..16 states | |
ParameterValue=0x1e | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[6802] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Digital Input Polarity (if set, input is active when switch is open (i.e. Normally closed)) | |
;SEVCONFIELD OBJECT=DIG_IN_POLARITY | |
;SEVCONFIELD SECTION=DIConfiguration | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[6802sub0] | |
ParameterName=Number of digital input bytes | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[6802sub1] | |
ParameterName=Digital Inputs 1..8 normally open/closed (set 1 for normally closed) | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=io.lcl_di_polarity_0 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=8 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 1 Polarity | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 2 Polarity | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 3 Polarity | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 4 Polarity | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 5 Polarity | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 6 Polarity | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 7 Polarity | |
;SEVCONFIELD BITMASK=0x40 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
;SEVCONFIELD SPLIT=7 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 8 Polarity | |
;SEVCONFIELD BITMASK=0x80 | |
;SEVCONFIELD BITSHIFT=0x7 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
[6802sub2] | |
ParameterName=Digital Inputs 9..15 normally open/closed (set 1 for normally closed) | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=io.lcl_di_polarity_1 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=8 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 9 Polarity | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 10 Polarity | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 11 Polarity | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 12 Polarity | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 13 Polarity | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 14 Polarity | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 15 Polarity | |
;SEVCONFIELD BITMASK=0x40 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
;SEVCONFIELD SPLIT=7 | |
;SEVCONFIELD PARAMETERNAME=Digital Input 16 Polarity | |
;SEVCONFIELD BITMASK=0x80 | |
;SEVCONFIELD BITSHIFT=0x7 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Normally Open | |
;SEVCONFIELD 1=Normally Closed | |
[6C01] | |
SubNumber=6 | |
ObjectType=9 | |
ParameterName=Analog input values. | |
;SEVCONFIELD OBJECT=READ_ALG_IN_16_BIT | |
;SEVCONFIELD SECTION=AIStatus | |
;SEVCONFIELD CATEGORY=MONITORING | |
[6C01sub0] | |
ParameterName=Number of analog inputs | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=8 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[6C01sub1] | |
ParameterName=Analog input 1 voltage | |
ParameterValue=0x0003 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
[6C01sub2] | |
ParameterName=Analog input 2 voltage | |
ParameterValue=0x0019 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
[6C01sub3] | |
ParameterName=Analog input 3 voltage | |
ParameterValue=0x02b1 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
[6C01sub4] | |
ParameterName=Analog input 4 voltage | |
ParameterValue=0x0cbe | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
[6C01sub5] | |
ParameterName=Analog input 5 voltage | |
ParameterValue=0x0c86 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
[6C11] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Analog output (contactor drive) values. | |
;SEVCONFIELD OBJECT=WRITE_ALG_OUT_16_BIT | |
;SEVCONFIELD SECTION=AOStatus | |
;SEVCONFIELD CATEGORY=MONITORING | |
[6C11sub0] | |
ParameterName=Number of analog outputs | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=7 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[6C11sub1] | |
ParameterName=Analog output 1 value (in amps or volts depending on current / voltage mode (46A1h)). | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V_or_A | |
[6C11sub2] | |
ParameterName=Analog output 2 value (in amps or volts depending on current / voltage mode (46A1h)). | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V_or_A | |
[6C11sub3] | |
ParameterName=Analog output 3 value (in amps or volts depending on current / voltage mode (46A1h)). | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V_or_A | |
[6C43] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Analog output (contactor drive) error modes | |
;SEVCONFIELD OBJECT=ALG_OUT_ERROR_MODE | |
;SEVCONFIELD SECTION=AOConfiguration | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[6C43sub0] | |
ParameterName=Number of analog outputs | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=7 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[6C43sub1] | |
ParameterName=Analog output 1 error mode (output goes to value in 6C44h if CAN communication is lost) | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x1 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=io.lcl_ao_error_mode_0 | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[6C43sub2] | |
ParameterName=Analog output 2 error mode (output goes to value in 6C44h if CAN communication is lost) | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x1 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=io.lcl_ao_error_mode_1 | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[6C43sub3] | |
ParameterName=Analog output 3 error mode (output goes to value in 6C44h if CAN communication is lost) | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x1 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=io.lcl_ao_error_mode_2 | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[6C44] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Analog output error value | |
;SEVCONFIELD OBJECT=ALG_OUT_ERROR_VALUE | |
;SEVCONFIELD SECTION=AOConfiguration | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[6C44sub0] | |
ParameterName=Number of analog outputs | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=7 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[6C44sub1] | |
ParameterName=Analog output 1 error value (analog output goes to this value if enabled in 6C43h when CAN communication is lost) | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=rw | |
LowLimit=-2147483648 | |
HighLimit=2147483647 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=5.96046447753906E-08 | |
;SEVCONFIELD UNITS=V_or_A | |
;SEVCONFIELD EEPROM=io.lcl_ao_error_value_0 | |
[6C44sub2] | |
ParameterName=Analog output 2 error value (analog output goes to this value if enabled in 6C43h when CAN communication is lost) | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=rw | |
LowLimit=-2147483648 | |
HighLimit=2147483647 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=5.96046447753906E-08 | |
;SEVCONFIELD UNITS=V_or_A | |
;SEVCONFIELD EEPROM=io.lcl_ao_error_value_1 | |
[6C44sub3] | |
ParameterName=Analog output 3 error value (analog output goes to this value if enabled in 6C43h when CAN communication is lost) | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=rw | |
LowLimit=-2147483648 | |
HighLimit=2147483647 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=5.96046447753906E-08 | |
;SEVCONFIELD UNITS=V_or_A | |
;SEVCONFIELD EEPROM=io.lcl_ao_error_value_2 | |
[6FFF] | |
ParameterName=Device Type | |
ParameterValue=0x000f0191 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
DefaultValue=0x000F0191 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DEVICE_TYPE | |
;SEVCONFIELD SECTION=CANOPEN_PROFILEEND | |
;SEVCONFIELD CATEGORY=MONITORING | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=2 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Type | |
;SEVCONFIELD BITMASK=0xFFFF | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=0xFFFF | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 402=Electric Drive | |
;SEVCONFIELD 401=Generic I/O | |
;SEVCONFIELD 419=Battery charger | |
;SEVCONFIELD 418=Battery module | |
;SEVCONFIELD 410 = inclinometer | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Additional data | |
;SEVCONFIELD BITMASK=0xFFFF0000 | |
;SEVCONFIELD BITSHIFT=0x10 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=0xFFFF | |
;SEVCONFIELD NUMBERFORMAT=BASE16 | |
[ManufacturerObjects] | |
SupportedObjects=240 | |
1=0x2020 | |
2=0x2021 | |
3=0x2040 | |
4=0x2060 | |
5=0x2100 | |
6=0x2101 | |
7=0x2120 | |
8=0x2121 | |
9=0x2122 | |
10=0x2123 | |
11=0x2124 | |
12=0x2125 | |
13=0x2126 | |
14=0x2127 | |
15=0x2129 | |
16=0x212A | |
17=0x212B | |
18=0x212C | |
19=0x212D | |
20=0x212E | |
21=0x212F | |
22=0x2130 | |
23=0x2131 | |
24=0x2139 | |
25=0x213A | |
26=0x2140 | |
27=0x2141 | |
28=0x2142 | |
29=0x2143 | |
30=0x2144 | |
31=0x2145 | |
32=0x2146 | |
33=0x2150 | |
34=0x2152 | |
35=0x2153 | |
36=0x2160 | |
37=0x217D | |
38=0x217F | |
39=0x2220 | |
40=0x2221 | |
41=0x2222 | |
42=0x2223 | |
43=0x2224 | |
44=0x2240 | |
45=0x2241 | |
46=0x2320 | |
47=0x2400 | |
48=0x2401 | |
49=0x2402 | |
50=0x2403 | |
51=0x2404 | |
52=0x2405 | |
53=0x2420 | |
54=0x2421 | |
55=0x2422 | |
56=0x2423 | |
57=0x2440 | |
58=0x2460 | |
59=0x2620 | |
60=0x2621 | |
61=0x2622 | |
62=0x2623 | |
63=0x2624 | |
64=0x2626 | |
65=0x2640 | |
66=0x2641 | |
67=0x2720 | |
68=0x2721 | |
69=0x2722 | |
70=0x2723 | |
71=0x2740 | |
72=0x2760 | |
73=0x2781 | |
74=0x2782 | |
75=0x2783 | |
76=0x2784 | |
77=0x2785 | |
78=0x2786 | |
79=0x278F | |
80=0x2790 | |
81=0x2800 | |
82=0x2810 | |
83=0x2820 | |
84=0x2830 | |
85=0x2840 | |
86=0x2850 | |
87=0x2870 | |
88=0x2871 | |
89=0x2872 | |
90=0x2900 | |
91=0x2901 | |
92=0x2902 | |
93=0x2903 | |
94=0x2904 | |
95=0x2906 | |
96=0x2907 | |
97=0x2908 | |
98=0x2909 | |
99=0x290A | |
100=0x290B | |
101=0x290C | |
102=0x290D | |
103=0x290E | |
104=0x2910 | |
105=0x2911 | |
106=0x2912 | |
107=0x2913 | |
108=0x2914 | |
109=0x2915 | |
110=0x2916 | |
111=0x2918 | |
112=0x2919 | |
113=0x291A | |
114=0x291C | |
115=0x291E | |
116=0x291F | |
117=0x2920 | |
118=0x2921 | |
119=0x2922 | |
120=0x2928 | |
121=0x2930 | |
122=0x2931 | |
123=0x2933 | |
124=0x29A0 | |
125=0x29A1 | |
126=0x2A00 | |
127=0x2A01 | |
128=0x2A10 | |
129=0x2A11 | |
130=0x2A20 | |
131=0x2A21 | |
132=0x2A22 | |
133=0x2A23 | |
134=0x2A24 | |
135=0x2A25 | |
136=0x2A26 | |
137=0x2A30 | |
138=0x2A31 | |
139=0x2B00 | |
140=0x2B01 | |
141=0x2B02 | |
142=0x2C00 | |
143=0x2C01 | |
144=0x2C02 | |
145=0x2C03 | |
146=0x2C30 | |
147=0x2C31 | |
148=0x2D00 | |
149=0x2D01 | |
150=0x2D02 | |
151=0x2E00 | |
152=0x3000 | |
153=0x3200 | |
154=0x3300 | |
155=0x3400 | |
156=0x4000 | |
157=0x4100 | |
158=0x4101 | |
159=0x4102 | |
160=0x4110 | |
161=0x4111 | |
162=0x4112 | |
163=0x4200 | |
164=0x4201 | |
165=0x4202 | |
166=0x4203 | |
167=0x4204 | |
168=0x4205 | |
169=0x4206 | |
170=0x4207 | |
171=0x4208 | |
172=0x4209 | |
173=0x420A | |
174=0x4300 | |
175=0x4301 | |
176=0x4600 | |
177=0x4601 | |
178=0x4602 | |
179=0x4603 | |
180=0x4610 | |
181=0x4611 | |
182=0x4612 | |
183=0x4614 | |
184=0x4620 | |
185=0x4621 | |
186=0x4623 | |
187=0x4624 | |
188=0x4630 | |
189=0x4640 | |
190=0x4641 | |
191=0x4650 | |
192=0x4651 | |
193=0x4653 | |
194=0x4654 | |
195=0x4680 | |
196=0x4681 | |
197=0x4690 | |
198=0x46A1 | |
199=0x46A2 | |
200=0x46A3 | |
201=0x46C0 | |
202=0x46C1 | |
203=0x46C2 | |
204=0x46C3 | |
205=0x46C4 | |
206=0x46D0 | |
207=0x5000 | |
208=0x5001 | |
209=0x5100 | |
210=0x5110 | |
211=0x5180 | |
212=0x5200 | |
213=0x5300 | |
214=0x5310 | |
215=0x5320 | |
216=0x5400 | |
217=0x5500 | |
218=0x5501 | |
219=0x5502 | |
220=0x5600 | |
221=0x5601 | |
222=0x5602 | |
223=0x5603 | |
224=0x5604 | |
225=0x5605 | |
226=0x5610 | |
227=0x5620 | |
228=0x5621 | |
229=0x5630 | |
230=0x5631 | |
231=0x5800 | |
232=0x5810 | |
233=0x5811 | |
234=0x5820 | |
235=0x5821 | |
236=0x5830 | |
237=0x5900 | |
238=0x5901 | |
239=0x5902 | |
240=0x5A01 | |
[2020] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Motor drive left information | |
;SEVCONFIELD OBJECT=MOTOR_DRIVE | |
;SEVCONFIELD SECTION=TractionStatus | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2020sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2020sub1] | |
ParameterName=controlword - left motor | |
ParameterValue=0x8000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[2020sub2] | |
ParameterName=statusword - left motor | |
ParameterValue=0x0833 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[2020sub3] | |
ParameterName=Target velocity - left motor | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=ro | |
LowLimit=-2147483648 | |
HighLimit=2147483647 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=RPM | |
[2020sub4] | |
ParameterName=Velocity actual value - left motor | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=rww | |
LowLimit=-2147483648 | |
HighLimit=2147483647 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=RPM | |
[2020sub5] | |
ParameterName=Max torque - left motor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.001 | |
[2020sub6] | |
ParameterName=Actual torque - left motor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.001 | |
[2021] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Motor drive right information | |
;SEVCONFIELD OBJECT=MOTOR_DRIVE | |
;SEVCONFIELD SECTION=TractionStatus | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2021sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2021sub1] | |
ParameterName=controlword - right motor | |
ParameterValue=0x8000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[2021sub2] | |
ParameterName=statusword - right motor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[2021sub3] | |
ParameterName=Target velocity - right motor | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=ro | |
LowLimit=-2147483648 | |
HighLimit=2147483647 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=RPM | |
[2021sub4] | |
ParameterName=Velocity actual value - right motor | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=rww | |
LowLimit=-2147483648 | |
HighLimit=2147483647 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=RPM | |
[2021sub5] | |
ParameterName=Max torque - right motor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.001 | |
[2021sub6] | |
ParameterName=Actual torque - right motor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.001 | |
[2040] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Motor drive pump information | |
;SEVCONFIELD OBJECT=MOTOR_DRIVE | |
;SEVCONFIELD SECTION=PumpStatus | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2040sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2040sub1] | |
ParameterName=controlword - pump motor | |
ParameterValue=0xc000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[2040sub2] | |
ParameterName=statusword - pump motor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[2040sub3] | |
ParameterName=Target velocity - pump motor | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=ro | |
LowLimit=-2147483648 | |
HighLimit=2147483647 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=RPM | |
[2040sub4] | |
ParameterName=Velocity actual value - pump motor | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=rww | |
LowLimit=-2147483648 | |
HighLimit=2147483647 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=RPM | |
[2040sub5] | |
ParameterName=Max torque - pump motor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.001 | |
[2040sub6] | |
ParameterName=Actual torque - pump motor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.001 | |
[2060] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Motor drive power steer information | |
;SEVCONFIELD OBJECT=MOTOR_DRIVE | |
;SEVCONFIELD SECTION=PSteerStatus | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2060sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2060sub1] | |
ParameterName=controlword - power steer motor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[2060sub2] | |
ParameterName=statusword - power steer motor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[2060sub3] | |
ParameterName=Target velocity - power steer motor | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=ro | |
LowLimit=-2147483648 | |
HighLimit=2147483647 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=RPM | |
[2060sub4] | |
ParameterName=Velocity actual value - power steer motor | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=rww | |
LowLimit=-2147483648 | |
HighLimit=2147483647 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=RPM | |
[2060sub5] | |
ParameterName=Max torque - power steer motor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.001 | |
[2060sub6] | |
ParameterName=Actual torque - power steer motor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.001 | |
[2100] | |
ParameterName=Key switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=VehicleDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2101] | |
ParameterName=Horn switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=VehicleDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2120] | |
ParameterName=Drive enable switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2121] | |
ParameterName=Forward Switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2122] | |
ParameterName=Reverse Switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2123] | |
ParameterName=FS1 switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2124] | |
ParameterName=Seat switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2125] | |
ParameterName=Handbrake switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2126] | |
ParameterName=Driveability Select 1 switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2127] | |
ParameterName=Driveability Select 2 switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2129] | |
ParameterName=Inch forward switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[212A] | |
ParameterName=Inch reverse switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[212B] | |
ParameterName=Inner left steer switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[212C] | |
ParameterName=Outer left steer switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[212D] | |
ParameterName=Inner right steer switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[212E] | |
ParameterName=Outer right steer switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[212F] | |
ParameterName=High speed switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2130] | |
ParameterName=Footbrake switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2131] | |
ParameterName=Regen Charging Enable Switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2139] | |
ParameterName=Belly | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[213A] | |
ParameterName=Deadman switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2140] | |
ParameterName=Pump 1 switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=PumpDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2141] | |
ParameterName=Pump 2 switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=PumpDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2142] | |
ParameterName=Pump 3 switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=PumpDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2143] | |
ParameterName=Pump 4 switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=PumpDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2144] | |
ParameterName=Pump 5 switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=PumpDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2145] | |
ParameterName=Pump 6 switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=PumpDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2146] | |
ParameterName=Pump 7 switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=PumpDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2150] | |
ParameterName=Pump Inhibit switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=PumpDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2152] | |
ParameterName=Pump Driveability 1 switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=PumpDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2153] | |
ParameterName=Pump Driveability 2 switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=PumpDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2160] | |
ParameterName=Power steer trigger switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=PSteerDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[217D] | |
ParameterName=Trip Distance Reset | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 1=Inactive | |
;SEVCONFIELD 0=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[217F] | |
ParameterName=Slave Left Motor Invert Switch | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionDI | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2220] | |
ParameterName=Throttle Input Voltage | |
ParameterValue=0x0003 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionAI | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2221] | |
ParameterName=Footbrake Pot Input Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionAI | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2222] | |
ParameterName=Economy Input Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionAI | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2223] | |
ParameterName=Steer Pot Input Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionAI | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2224] | |
ParameterName=Throttle 2 Input Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionAI | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2240] | |
ParameterName=Pump Throttle 1 Input Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionAI | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2241] | |
ParameterName=Pump Throttle 2 Input Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_IN | |
;SEVCONFIELD SECTION=TractionAI | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2320] | |
ParameterName=Traction Drive Hour-meter output | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_OUT | |
;SEVCONFIELD SECTION=TractionDO | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2400] | |
ParameterName=Line contactor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT | |
;SEVCONFIELD SECTION=VehicleAO | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2401] | |
ParameterName=External LED | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT | |
;SEVCONFIELD SECTION=VehicleAO | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2402] | |
ParameterName=Alarm buzzer | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT | |
;SEVCONFIELD SECTION=VehicleAO | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2403] | |
ParameterName=Horn | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT | |
;SEVCONFIELD SECTION=VehicleAO | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2404] | |
ParameterName=Brake Lights | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT | |
;SEVCONFIELD SECTION=VehicleAO | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2405] | |
ParameterName=Service Due | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT | |
;SEVCONFIELD SECTION=VehicleAO | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2420] | |
ParameterName=Electro-mechanical brake | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT | |
;SEVCONFIELD SECTION=TractionAO | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2421] | |
ParameterName=Traction Motor Cooling Fan | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT | |
;SEVCONFIELD SECTION=TractionAO | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2422] | |
ParameterName=Motor Isolation Contactor | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT | |
;SEVCONFIELD SECTION=TractionAO | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2423] | |
ParameterName=High / Low Speed Indication | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT | |
;SEVCONFIELD SECTION=TractionAO | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2440] | |
ParameterName=Pump contactor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT | |
;SEVCONFIELD SECTION=PumpAO | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2460] | |
ParameterName=Power steer contactor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT | |
;SEVCONFIELD SECTION=PSteerAO | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2620] | |
ParameterName=Throttle Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE | |
;SEVCONFIELD SECTION=TractionAO | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2621] | |
ParameterName=Footbrake Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE | |
;SEVCONFIELD SECTION=TractionAO | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2622] | |
ParameterName=Economy Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE | |
;SEVCONFIELD SECTION=TractionAO | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2623] | |
ParameterName=Steer Angle | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE | |
;SEVCONFIELD SECTION=TractionAO | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2624] | |
ParameterName=Steer Angle (in degrees) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-9000 | |
HighLimit=9000 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.01 | |
;SEVCONFIELD UNITS=Degrees | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE | |
;SEVCONFIELD SECTION=TractionValue | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2626] | |
ParameterName=Secondary Throttle Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE | |
;SEVCONFIELD SECTION=TractionAO | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2640] | |
ParameterName=Pump Throttle 1 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE | |
;SEVCONFIELD SECTION=PumpAO | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2641] | |
ParameterName=Pump Throttle 2 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE | |
;SEVCONFIELD SECTION=PumpAO | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2720] | |
SubNumber=6 | |
ObjectType=9 | |
ParameterName=Traction Application Status | |
;SEVCONFIELD OBJECT=TRACTION_STATUS | |
;SEVCONFIELD SECTION=TractionStatus | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2720sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=5 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2720sub1] | |
ParameterName=Driveability Profile Status | |
ParameterValue=0x0001 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=6 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Baseline | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Driveability Select 1 | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Driveability Select 2 | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Inactive | |
;SEVCONFIELD 1=Active | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Low Speed | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=On | |
;SEVCONFIELD 1=Off | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=BDI | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=On | |
;SEVCONFIELD 1=Off | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Service | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=On | |
;SEVCONFIELD 1=Off | |
[2720sub2] | |
ParameterName=Traction Drive State | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=11 | |
;SEVCONFIELD 0=OFF | |
;SEVCONFIELD 1=FOOTBRAKING | |
;SEVCONFIELD 2=DRIVE | |
;SEVCONFIELD 3=STOP_AT_CD_RATE | |
;SEVCONFIELD 4=CD_DECEL | |
;SEVCONFIELD 5=CD_ACCEL | |
;SEVCONFIELD 6=NTRL_BRK_OR_COAST | |
;SEVCONFIELD 7=HILL_HOLD | |
;SEVCONFIELD 8=IDLE | |
;SEVCONFIELD 9=POWER_OFF | |
;SEVCONFIELD 10=CONTROLLED_ROLL_OFF | |
[2720sub3] | |
ParameterName=Drive / Direction Change State | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=7 | |
;SEVCONFIELD 0=NO_DIR_SEL_NO_LDD | |
;SEVCONFIELD 1=FWD_SEL_LDD_FWD | |
;SEVCONFIELD 2=NO_DIR_SEL_LDD_FWD | |
;SEVCONFIELD 3=REV_SEL_LDD_FWD | |
;SEVCONFIELD 4=FWD_SEL_LDD_REV | |
;SEVCONFIELD 5=NO_DIR_SEL_LDD_REV | |
;SEVCONFIELD 6=REV_SEL_LDD_REV | |
[2720sub4] | |
ParameterName=SRO State | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=5 | |
;SEVCONFIELD 0=NO_FS1_NO_DIR | |
;SEVCONFIELD 1=NO_FS1_DIR_ACTIVE | |
;SEVCONFIELD 2=FS1_ACTIVE_NO_DIR | |
;SEVCONFIELD 3=FS1_ACTIVE_DIR_ACTIVE | |
;SEVCONFIELD 4=SRO_FAULT | |
[2720sub5] | |
ParameterName=Operator Presence (Seat) State | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=5 | |
;SEVCONFIELD 0=SEAT_SWITCH_INACTIVE | |
;SEVCONFIELD 1=SEAT_SWITCH_ACTIVE | |
;SEVCONFIELD 2=IN_DRIVE | |
;SEVCONFIELD 3=SEAT_INACTIVE_IN_DRIVE | |
;SEVCONFIELD 4=SEAT_FAULT | |
[2721] | |
ParameterName=Vehicle Speed | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=kph | |
;SEVCONFIELD OBJECT=VEHICLE_SPEED | |
;SEVCONFIELD SECTION=TractionStatus | |
;SEVCONFIELD EEPROM=app_stat.speed_info.vehicle_speed | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2722] | |
ParameterName=User speed 1 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=VEHICLE_SPEED | |
;SEVCONFIELD SECTION=TractionStatus | |
;SEVCONFIELD EEPROM=app_stat.speed_info.user_speed | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2723] | |
ParameterName=User speed 2 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=VEHICLE_SPEED | |
;SEVCONFIELD SECTION=TractionStatus | |
;SEVCONFIELD EEPROM=app_stat.speed_info.user_speed_2 | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2740] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Pump Application Status | |
;SEVCONFIELD OBJECT=PUMP_STATUS | |
;SEVCONFIELD SECTION=PUMPSTATUS | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2740sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2740sub1] | |
ParameterName=Pump Drive State | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=6 | |
;SEVCONFIELD 0=OFF | |
;SEVCONFIELD 1=NEUTRAL | |
;SEVCONFIELD 2=PUMP_REQ_BUT_INHIBITED | |
;SEVCONFIELD 3=PUMP_INHIBIT | |
;SEVCONFIELD 4=PUMP | |
;SEVCONFIELD 5=PUMP_DURING_INHIBIT | |
[2740sub2] | |
ParameterName=Pump Driveability Profile Status | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=3 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Baseline | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=On | |
;SEVCONFIELD 1=Off | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Driveability Select 1 | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=On | |
;SEVCONFIELD 1=Off | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Driveability Select 2 | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=On | |
;SEVCONFIELD 1=Off | |
[2760] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=Power Steer Application Status | |
;SEVCONFIELD OBJECT=PSTEER_STATUS | |
;SEVCONFIELD SECTION=PSTEERSTATUS | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2760sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2760sub1] | |
ParameterName=Power Steer Drive State | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=4 | |
;SEVCONFIELD 0=OFF | |
;SEVCONFIELD 1=NEUTRAL | |
;SEVCONFIELD 2=WAIT_FOR_TIMEOUT | |
;SEVCONFIELD 3=POWER_STEER | |
[2781] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Key Hours Counter | |
;SEVCONFIELD OBJECT=HOURS_COUNTER | |
;SEVCONFIELD SECTION=HoursCounters | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=LOGGING | |
[2781sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2781sub1] | |
ParameterName=Hours | |
ParameterValue=0x0031 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=Hours | |
[2781sub2] | |
ParameterName=Minutes / Seconds | |
ParameterValue=0xb4 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xEF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[2782] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Traction Hours Counter | |
;SEVCONFIELD OBJECT=HOURS_COUNTER | |
;SEVCONFIELD SECTION=HoursCounters | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=LOGGING | |
[2782sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2782sub1] | |
ParameterName=Hours | |
ParameterValue=0x0003 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=Hours | |
[2782sub2] | |
ParameterName=Minutes / Seconds | |
ParameterValue=0xba | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xEF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[2783] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Pump Hours Counter | |
;SEVCONFIELD OBJECT=HOURS_COUNTER | |
;SEVCONFIELD SECTION=HoursCounters | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=LOGGING | |
[2783sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2783sub1] | |
ParameterName=Hours | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=Hours | |
[2783sub2] | |
ParameterName=Minutes / Seconds | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xEF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[2784] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Power Steer Hours Counter | |
;SEVCONFIELD OBJECT=HOURS_COUNTER | |
;SEVCONFIELD SECTION=HoursCounters | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=LOGGING | |
[2784sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2784sub1] | |
ParameterName=Hours | |
ParameterValue=0x0005 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=Hours | |
[2784sub2] | |
ParameterName=Minutes / Seconds | |
ParameterValue=0x2e | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xEF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[2785] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Work Hours Counter | |
;SEVCONFIELD OBJECT=HOURS_COUNTER | |
;SEVCONFIELD SECTION=HoursCounters | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=LOGGING | |
[2785sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2785sub1] | |
ParameterName=Hours | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=Hours | |
[2785sub2] | |
ParameterName=Minutes / Seconds | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xEF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[2786] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Charging Hours Counter | |
;SEVCONFIELD OBJECT=HOURS_COUNTER | |
;SEVCONFIELD SECTION=HoursCounters | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=LOGGING | |
[2786sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2786sub1] | |
ParameterName=Hours | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=Hours | |
[2786sub2] | |
ParameterName=Minutes / Seconds | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xEF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[278F] | |
ParameterName=Running indicators | |
ParameterValue=0x0005 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=HOURS_COUNTER | |
;SEVCONFIELD SECTION=HoursCounters | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=8 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Node Hours | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Stopped | |
;SEVCONFIELD 1=Running | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Pulsing Hours | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Stopped | |
;SEVCONFIELD 1=Running | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Key Hours | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Stopped | |
;SEVCONFIELD 1=Running | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Traction Hours | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Stopped | |
;SEVCONFIELD 1=Running | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=Pump Hours | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Stopped | |
;SEVCONFIELD 1=Running | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Power Steer Hours | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Stopped | |
;SEVCONFIELD 1=Running | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=Work Hours | |
;SEVCONFIELD BITMASK=0x40 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Stopped | |
;SEVCONFIELD 1=Running | |
;SEVCONFIELD SPLIT=7 | |
[2790] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=Battery Status | |
;SEVCONFIELD OBJECT=BatteryStatus | |
;SEVCONFIELD SECTION=BatteryStatus | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2790sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2790sub1] | |
ParameterName=BDI remaining charge | |
ParameterValue=0x40 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=% | |
[2800] | |
ParameterName=Force system to pre-operational state | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=FORCE_TO_PREOP | |
;SEVCONFIELD SECTION=CANopenSetup | |
;SEVCONFIELD EEPROM=vehicle.force_to_pre_op | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Operational | |
;SEVCONFIELD 1=Pre-Operational | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=MONITORING | |
[2810] | |
SubNumber=8 | |
ObjectType=9 | |
ParameterName=Node Indication | |
;SEVCONFIELD OBJECT=NODE_INDICATION | |
;SEVCONFIELD SECTION=CANopenSetup | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2810sub0] | |
ParameterName=Number of slaves | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=7 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vehicle.number_slaves | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2810sub1] | |
ParameterName=1st slave node ID | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=127 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vehicle.slave_node_id_0 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2810sub2] | |
ParameterName=2nd slave node ID | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=127 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vehicle.slave_node_id_1 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2810sub3] | |
ParameterName=3rd slave node ID | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=127 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vehicle.slave_node_id_2 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2810sub4] | |
ParameterName=4th slave node ID | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=127 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vehicle.slave_node_id_3 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2810sub5] | |
ParameterName=5th slave node ID | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=127 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vehicle.slave_node_id_4 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2810sub6] | |
ParameterName=6th slave node ID | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=127 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vehicle.slave_node_id_5 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2810sub7] | |
ParameterName=7th slave node ID | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=127 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vehicle.slave_node_id_6 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2820] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Line Contactor parameters | |
;SEVCONFIELD OBJECT=LINE_CONT_PARAM | |
;SEVCONFIELD SECTION=VehicleConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2820sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2820sub1] | |
ParameterName=Line contactor drop out | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vehicle.line_contactor_drop_enabled | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2820sub2] | |
ParameterName=Line contactor drop out timer | |
ParameterValue=0x3c | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=10 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=vehicle.line_contactor_drop_timer | |
[2820sub3] | |
ParameterName=Line contactor options | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=1 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Line Contactor Welded Fault | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Enabled | |
;SEVCONFIELD 1=Disabled | |
[2830] | |
ParameterName=Assumed fault severity level for EMCY received from non-sevcon nodes. | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=5 | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=NON_SEVCON_EMCY_LEVEL | |
;SEVCONFIELD SECTION=CANOPENSETUP | |
;SEVCONFIELD EEPROM=vehicle.anon_emcy_severity | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2840] | |
SubNumber=12 | |
ObjectType=9 | |
ParameterName=Alarm Buzzer Configuration | |
;SEVCONFIELD OBJECT=BUZZER_CONFIG | |
;SEVCONFIELD SECTION=VehicleConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2840sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x0b | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=17 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2840sub1] | |
ParameterName=Alarm buzzer source enable flags. | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0x0F | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vehicle.buzzer_enable | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=6 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Forward | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Reverse | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Roll off | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Fault | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=BDI low | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=ELYT low | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
[2840sub2] | |
ParameterName=Forward Cadence On Time | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[0][0] | |
[2840sub3] | |
ParameterName=Forward Cadence Off Time | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=4 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[0][1] | |
[2840sub4] | |
ParameterName=Reverse Cadence On Time | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[1][0] | |
[2840sub5] | |
ParameterName=Reverse Cadence Off Time | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[1][1] | |
[2840sub6] | |
ParameterName=Fault Cadence On Time | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[2][0] | |
[2840sub7] | |
ParameterName=Fault Cadence Off Time | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[2][1] | |
[2840sub8] | |
ParameterName=Controlled Roll Off Cadence On Time | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=4 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[3][0] | |
[2840sub9] | |
ParameterName=Controlled Roll Off Cadence Off Time | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[3][1] | |
[2840subA] | |
ParameterName=BDI low Cadence On Time | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=misc.bdi_cadence[0] | |
[2840subB] | |
ParameterName=BDI low Cadence Off Time | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=misc.bdi_cadence[1] | |
[2850] | |
SubNumber=6 | |
ObjectType=9 | |
ParameterName=Servicing | |
;SEVCONFIELD OBJECT=SERVICE_CONFIG | |
;SEVCONFIELD SECTION=VehicleConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2850sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=5 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2850sub1] | |
ParameterName=Reset (write to reset next service time) | |
ObjectType=7 | |
DataType=1 | |
AccessType=wo | |
LowLimit=0 | |
HighLimit=0x1 | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=1 | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Reset | |
;SEVCONFIELD 1=Reset | |
[2850sub2] | |
ParameterName=Flags | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=vehicle.service_flags | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=3 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Enable Service | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=On | |
;SEVCONFIELD 1=Off | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Activate Contactor Drive | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Flash LED | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
[2850sub3] | |
ParameterName=Source Hours Counter | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0x80 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=vehicle.service_source | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2850sub4] | |
ParameterName=Time between services (Service Interval) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
;SEVCONFIELD EEPROM=vehicle.service_interval | |
[2850sub5] | |
ParameterName=Next Service Due time | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0xFFFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
;SEVCONFIELD EEPROM=vehicle.service_next_due | |
[2870] | |
SubNumber=8 | |
ObjectType=9 | |
ParameterName=Master Battery Current Limit Parameters | |
;SEVCONFIELD OBJECT=IBATT_LIMIT_PARAM | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2870sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x07 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=7 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2870sub1] | |
ParameterName=Battery current limit data source | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=4 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=traction.traction_mode | |
;SEVCONFIELD NUMBER_FORMAT=5 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Use max currents only | |
;SEVCONFIELD 2=Use Delaware BMS | |
;SEVCONFIELD 3=Follow Profiles | |
;SEVCONFIELD 4=Use max power | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2870sub2] | |
ParameterName=Maximum battery discharge current | |
ParameterValue=0x0078 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=A | |
[2870sub3] | |
ParameterName=Maximum battery recharge current | |
ParameterValue=0xff9c | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=0 | |
PDOMapping=1 | |
DefaultValue=0xFF9C | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=A | |
[2870sub4] | |
ParameterName=Maximum battery discharge current in Drive Profile 1 | |
ParameterValue=0x0050 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=100 | |
PDOMapping=1 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=% | |
[2870sub5] | |
ParameterName=Maximum battery discharge current in Drive Profile 2 | |
ParameterValue=0x001e | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=100 | |
PDOMapping=1 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=% | |
[2870sub6] | |
ParameterName=Maximum battery discharge power | |
ParameterValue=0x0a00 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=kW | |
[2870sub7] | |
ParameterName=Maximum battery recharge power | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=0 | |
PDOMapping=1 | |
DefaultValue=0xFF9C | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=kW | |
[2871] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Master Battery Current Limit Status | |
;SEVCONFIELD OBJECT=IBATT_LIMIT_STATUS | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2871sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2871sub1] | |
ParameterName=Available traction battery discharge current | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=A | |
[2871sub2] | |
ParameterName=Available traction battery charge current | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=0 | |
PDOMapping=1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=A | |
[2872] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Battery Current Limit Protection Parameters | |
;SEVCONFIELD OBJECT=IBATT_LIMIT_PROTECTION | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2872sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2872sub1] | |
ParameterName=Cutback range for low traction discharge current | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=A | |
[2872sub2] | |
ParameterName=Cutback range for low traction charge current | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=0 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=A | |
[2900] | |
ParameterName=Traction control mode (Torque/speed mode (0) or closed loop speed control (1)) | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=TRAC_CTRL_MODE | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD EEPROM=traction.traction_mode | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Torque/Speed | |
;SEVCONFIELD 1=Speed Control | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2901] | |
ParameterName=Hill hold delay | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD OBJECT=HILL_HOLD_DELAY | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD EEPROM=traction.hill_hold_delay | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2902] | |
ParameterName=Seat Switch delay | |
ParameterValue=0x14 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=20 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD OBJECT=SEAT_DELAY | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD EEPROM=traction.seat_delay | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2903] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Electromechanical Brake parameters | |
;SEVCONFIELD OBJECT=EBRAKE_PARAM | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2903sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2903sub1] | |
ParameterName=Electromechanical brake apply delay | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=50 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=traction.ebrake_apply_delay | |
[2903sub2] | |
ParameterName=Electromechanical brake release delay | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=traction.ebrake_release_delay | |
[2903sub3] | |
ParameterName=Electromechanical brake control | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Release after motor started | |
;SEVCONFIELD 1=Release immediately | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2904] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=High speed parameters | |
;SEVCONFIELD OBJECT=HIGH_SPEED_PARAM | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2904sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2904sub1] | |
ParameterName=Latched / momentary operation | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=traction.high_speed_latched_momentary | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Latched | |
;SEVCONFIELD 1=Momentary | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2906] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=Low Speed Profile Configuration | |
;SEVCONFIELD OBJECT=LOW_SPEED_PRO_CONFIG | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2906sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2906sub1] | |
ParameterName=Speed below which low speed profile is active | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=misc.low_speed_threshold | |
[2907] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=High/Low Speed Indication Configuration | |
;SEVCONFIELD OBJECT=SPEED_INDICATION_CONFIG | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2907sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2907sub1] | |
ParameterName=Activation Speed | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=misc.high_low_speed_ind_act_speed | |
[2907sub2] | |
ParameterName=Deactivation Speed | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=misc.high_low_speed_ind_deact_speed | |
[2907sub3] | |
ParameterName=Analogue output voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=misc.high_low_speed_ind_ao_voltage | |
[2908] | |
ParameterName=Drive torque disable speed | |
ParameterValue=0x012c | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=500 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD OBJECT=DRIVE_TRQ_DISABLE_SPEED | |
;SEVCONFIELD EEPROM=misc.trac_drive_disable_speed | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2909] | |
ParameterName=Direction change delay | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD OBJECT=DIR_CHANGE_DELAY | |
;SEVCONFIELD EEPROM=misc.trac_dir_change_delay | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[290A] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=S-Curve Control | |
;SEVCONFIELD OBJECT=S_CURVE_PARAM | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[290Asub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[290Asub1] | |
ParameterName=Target speed approach curve | |
ParameterValue=0x08 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=11 | |
PDOMapping=0 | |
DefaultValue=8 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=misc.s_curve_factor_a | |
[290Asub2] | |
ParameterName=Ramp change delay | |
ParameterValue=0x7f | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=127 | |
PDOMapping=0 | |
DefaultValue=0x7F | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=misc.s_curve_factor_b | |
[290Asub3] | |
ParameterName=Ramp change delay speed | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=misc.s_curve_speed | |
[290B] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Tilt Alarm Delays | |
;SEVCONFIELD OBJECT=TILT_ALARM_DELAYS | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[290Bsub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=8 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[290Bsub1] | |
ParameterName=Off delay | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
[290Bsub2] | |
ParameterName=On delay | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
[290C] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Belly operation configuration | |
;SEVCONFIELD OBJECT=BELLY_CONFIGURATION | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[290Csub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[290Csub1] | |
ParameterName=Belly throttle value | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=16384 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.belly_throttle | |
[290Csub2] | |
ParameterName=Belly max speed | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=5000 | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=misc.belly_max_speed | |
[290Csub3] | |
ParameterName=Belly timeout | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=100 | |
PDOMapping=0 | |
DefaultValue=50 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=misc.belly_timeout | |
[290D] | |
ParameterName=Neutral Braking Exit Timer | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.001 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD OBJECT=NTRL_BRK_EXIT_DELAY | |
;SEVCONFIELD EEPROM=misc.ntrl_brk_exit_delay | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[290E] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Brake Feathering | |
;SEVCONFIELD OBJECT=BRAKE_FEATHERING | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[290Esub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=5 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[290Esub1] | |
ParameterName=Brake feathering start speed | |
ParameterValue=0x1388 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=300 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=RPM | |
[290Esub2] | |
ParameterName=Brake feathering end speed | |
ParameterValue=0x0dac | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=50 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=RPM | |
[290Esub3] | |
ParameterName=Brake feathering end torque | |
ParameterValue=0x00c8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.001 | |
[2910] | |
SubNumber=17 | |
ObjectType=9 | |
ParameterName=Throttle parameters | |
;SEVCONFIELD OBJECT=THROTTLE_PARAM | |
;SEVCONFIELD SECTION=TractionAIConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2910sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x10 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=22 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2910sub1] | |
ParameterName=Throttle Flags | |
ParameterValue=0x0070 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=traction.throttle_flags | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=16 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Proportional Braking | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Directional Throttle | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Speed Limit Mode | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Proportional to throttle | |
;SEVCONFIELD 1=Fixed at maximum | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Braking Directional Throttle | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=Reverse Speed Limit Encoding | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Handbrake Fault | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Enabled | |
;SEVCONFIELD 1=Disabled | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=Proportional Speed Limit in Braking | |
;SEVCONFIELD BITMASK=0x40 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Enabled | |
;SEVCONFIELD 1=Disabled | |
;SEVCONFIELD SPLIT=7 | |
;SEVCONFIELD PARAMETERNAME=Driveability profile generation style (some builds only) | |
;SEVCONFIELD BITMASK=0x80 | |
;SEVCONFIELD BITSHIFT=0x7 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Use lowest values | |
;SEVCONFIELD 1=Use active profile only | |
;SEVCONFIELD SPLIT=8 | |
;SEVCONFIELD PARAMETERNAME=Allow step change in steer angle | |
;SEVCONFIELD BITMASK=0x100 | |
;SEVCONFIELD BITSHIFT=0x8 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=9 | |
;SEVCONFIELD PARAMETERNAME=Virtual FS1 | |
;SEVCONFIELD BITMASK=0x200 | |
;SEVCONFIELD BITSHIFT=0x9 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=10 | |
;SEVCONFIELD PARAMETERNAME=Absolute Steer Angle in single traction | |
;SEVCONFIELD BITMASK=0x400 | |
;SEVCONFIELD BITSHIFT=0xA | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=11 | |
;SEVCONFIELD PARAMETERNAME=Separate Seat Regen Braking settings | |
;SEVCONFIELD BITMASK=0x800 | |
;SEVCONFIELD BITSHIFT=0xB | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=12 | |
;SEVCONFIELD PARAMETERNAME=Slave Left Motor Speed Inversion | |
;SEVCONFIELD BITMASK=0x1000 | |
;SEVCONFIELD BITSHIFT=0xC | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=13 | |
;SEVCONFIELD PARAMETERNAME=Brake Light when Neutral Braking | |
;SEVCONFIELD BITMASK=0x2000 | |
;SEVCONFIELD BITSHIFT=0xD | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=14 | |
;SEVCONFIELD PARAMETERNAME=Inching functionality | |
;SEVCONFIELD BITMASK=0x4000 | |
;SEVCONFIELD BITSHIFT=0xE | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Generic | |
;SEVCONFIELD 1=With E.Park Brake | |
;SEVCONFIELD SPLIT=15 | |
;SEVCONFIELD PARAMETERNAME=Proportional Speed Limit in Drive | |
;SEVCONFIELD BITMASK=0x8000 | |
;SEVCONFIELD BITSHIFT=0xF | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Enabled | |
;SEVCONFIELD 1=Disabled | |
[2910sub2] | |
ParameterName=Throttle input characteristic | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=3 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=1 | |
;SEVCONFIELD EEPROM=traction.throttle_char | |
;SEVCONFIELD NUMBER_FORMAT=4 | |
;SEVCONFIELD 0=User Defd | |
;SEVCONFIELD 1=Linear | |
;SEVCONFIELD 2=Curved | |
;SEVCONFIELD 3=Crawl | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2910sub3] | |
ParameterName=Throttle Start Voltage 1 | |
ParameterValue=0x0033 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=16 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=traction.throttle_0_start_voltage | |
[2910sub4] | |
ParameterName=Throttle Start Value 1 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.throttle_0_start_value | |
[2910sub5] | |
ParameterName=Throttle End Voltage 1 | |
ParameterValue=0x05b3 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=1309 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=traction.throttle_0_end_voltage | |
[2910sub6] | |
ParameterName=Throttle End Value 1 | |
ParameterValue=0x7ffe | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.throttle_0_end_value | |
[2910sub7] | |
ParameterName=Throttle Start Voltage 2 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=traction.throttle_1_start_voltage | |
[2910sub8] | |
ParameterName=Throttle Start Value 2 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.throttle_1_start_value | |
[2910sub9] | |
ParameterName=Throttle End Voltage 2 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=traction.throttle_1_end_voltage | |
[2910subA] | |
ParameterName=Throttle End Value 2 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.throttle_1_end_value | |
[2910subB] | |
ParameterName=User Defined Char Pt 1 Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=9830 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=traction.throttle_ud_map_0_voltage | |
[2910subC] | |
ParameterName=User Defined Char Pt 1 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=9830 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=traction.throttle_ud_map_0_value | |
[2910subD] | |
ParameterName=User Defined Char Pt 2 Voltage | |
ParameterValue=0x8000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=19660 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=traction.throttle_ud_map_1_voltage | |
[2910subE] | |
ParameterName=User Defined Char Pt 2 Value | |
ParameterValue=0x8000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=traction.throttle_ud_map_1_value | |
[2910subF] | |
ParameterName=User Defined Char Pt 3 Voltage | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=52428 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=traction.throttle_ud_map_2_voltage | |
[2910sub10] | |
ParameterName=User Defined Char Pt 3 Value | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=62258 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=traction.throttle_ud_map_2_value | |
[2911] | |
SubNumber=15 | |
ObjectType=9 | |
ParameterName=Footbrake parameters | |
;SEVCONFIELD OBJECT=FBRAKE_PARAM | |
;SEVCONFIELD SECTION=TractionAIConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2911sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x0e | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=13 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2911sub1] | |
ParameterName=Drive / footbrake priority | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=traction.drive_footbrake_priority | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Drive | |
;SEVCONFIELD 1=Footbrake | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2911sub2] | |
ParameterName=Footbrake braking exit speed | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=traction.footbrake_minimum_speed | |
[2911sub3] | |
ParameterName=Footbrake Input Characteristic | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=3 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=traction.footbrake_char | |
;SEVCONFIELD NUMBER_FORMAT=4 | |
;SEVCONFIELD 0=User Defined | |
;SEVCONFIELD 1=Linear | |
;SEVCONFIELD 2=Curved | |
;SEVCONFIELD 3=Crawl | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2911sub4] | |
ParameterName=Footbrake Start Voltage 1 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=traction.footbrake_start_voltage | |
[2911sub5] | |
ParameterName=Footbrake Start Value 1 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.footbrake_start_value | |
[2911sub6] | |
ParameterName=Footbrake End Voltage 1 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=900 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=traction.footbrake_end_voltage | |
[2911sub7] | |
ParameterName=Footbrake End Value 1 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.footbrake_end_value | |
[2911sub8] | |
ParameterName=User Defined Char Pt 1 Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=9830 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=traction.footbrake_ud_map_0_voltage | |
[2911sub9] | |
ParameterName=User Defined Char Pt 1 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=9830 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=traction.footbrake_ud_map_0_value | |
[2911subA] | |
ParameterName=User Defined Char Pt 2 Voltage | |
ParameterValue=0x8000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=19660 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=traction.footbrake_ud_map_1_voltage | |
[2911subB] | |
ParameterName=User Defined Char Pt 2 Value | |
ParameterValue=0x8000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=traction.footbrake_ud_map_1_value | |
[2911subC] | |
ParameterName=User Defined Char Pt 3 Voltage | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=52428 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=traction.footbrake_ud_map_2_voltage | |
[2911subD] | |
ParameterName=User Defined Char Pt 3 Value | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=62258 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=traction.footbrake_ud_map_2_value | |
[2911subE] | |
ParameterName=Footbrake/Drive time out | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=misc.footbrake_timeout | |
[2912] | |
SubNumber=6 | |
ObjectType=9 | |
ParameterName=Economy parameters | |
;SEVCONFIELD OBJECT=ECONOMY_PARAM | |
;SEVCONFIELD SECTION=TractionAIConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2912sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=5 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2912sub1] | |
ParameterName=Economy function | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=2 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=traction.economy_function | |
;SEVCONFIELD NUMBER_FORMAT=3 | |
;SEVCONFIELD 0=None | |
;SEVCONFIELD 1=Max Torque | |
;SEVCONFIELD 2=Accel Rate | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2912sub2] | |
ParameterName=Economy Start Voltage 1 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=traction.economy_start_voltage | |
[2912sub3] | |
ParameterName=Economy Start Value 1 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.economy_start_value | |
[2912sub4] | |
ParameterName=Economy End Voltage 1 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=900 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=traction.economy_end_voltage | |
[2912sub5] | |
ParameterName=Economy End Value 1 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.economy_end_value | |
[2913] | |
SubNumber=20 | |
ObjectType=9 | |
ParameterName=Steering parameters | |
;SEVCONFIELD OBJECT=STEERING_PARAM | |
;SEVCONFIELD SECTION=TractionAIConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2913sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x13 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=19 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2913sub1] | |
ParameterName=Steer pot left voltage | |
ParameterValue=0x0064 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=traction.steer_left_voltage | |
[2913sub2] | |
ParameterName=Steer pot right voltage | |
ParameterValue=0x0384 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=900 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=traction.steer_right_voltage | |
[2913sub3] | |
ParameterName=Steer pot zero voltage | |
ParameterValue=0x01f4 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=500 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=traction.steer_zero_voltage | |
[2913sub4] | |
ParameterName=Angle (Outer Wheel) Pt 1 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=2.74666585283975E-03 | |
;SEVCONFIELD EEPROM=traction.steering_cutback_map_0_angle | |
[2913sub5] | |
ParameterName=Cutback (Outer Wheel) Pt 1 | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.steering_cutback_map_0_speed | |
[2913sub6] | |
ParameterName=Angle (Outer Wheel) Pt 2 | |
ParameterValue=0x0ccc | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=3276 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=2.74666585283975E-03 | |
;SEVCONFIELD EEPROM=traction.steering_cutback_map_1_angle | |
[2913sub7] | |
ParameterName=Cutback (Outer Wheel) Pt 2 | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.steering_cutback_map_1_speed | |
[2913sub8] | |
ParameterName=Angle (Outer Wheel) Pt 3 | |
ParameterValue=0x5999 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=22937 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=2.74666585283975E-03 | |
;SEVCONFIELD EEPROM=traction.steering_cutback_map_2_angle | |
[2913sub9] | |
ParameterName=Cutback (Outer Wheel) Pt 3 | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=22937 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.steering_cutback_map_2_speed | |
[2913subA] | |
ParameterName=Angle (Outer Wheel) Pt 4 | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=2.74666585283975E-03 | |
;SEVCONFIELD EEPROM=traction.steering_cutback_map_3_angle | |
[2913subB] | |
ParameterName=Cutback (Outer Wheel) Pt 4 | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=3276 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.steering_cutback_map_3_speed | |
[2913subC] | |
ParameterName=Angle (Inner Wheel) Pt 1 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=2.74666585283975E-03 | |
;SEVCONFIELD EEPROM=traction.steering_map_0_angle | |
[2913subD] | |
ParameterName=Cutback (Inner Wheel) Pt 1 | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.steering_map_0_speed | |
[2913subE] | |
ParameterName=Angle (Inner Wheel) Pt 2 | |
ParameterValue=0x051e | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=1310 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=2.74666585283975E-03 | |
;SEVCONFIELD EEPROM=traction.steering_map_1_angle | |
[2913subF] | |
ParameterName=Cutback (Inner Wheel) Pt 2 | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.steering_map_1_speed | |
[2913sub10] | |
ParameterName=Angle (Inner Wheel) Pt 3 | |
ParameterValue=0x5554 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=22937 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=2.74666585283975E-03 | |
;SEVCONFIELD EEPROM=traction.steering_map_2_angle | |
[2913sub11] | |
ParameterName=Cutback (Inner Wheel) Pt 3 | |
ParameterValue=0x3332 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.steering_map_2_speed | |
[2913sub12] | |
ParameterName=Angle (Inner Wheel) Pt 4 | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=2.74666585283975E-03 | |
;SEVCONFIELD EEPROM=traction.steering_map_3_angle | |
[2913sub13] | |
ParameterName=Cutback (Inner Wheel) Pt 4 | |
ParameterValue=0x3332 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=-3276 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=traction.steering_map_3_speed | |
[2914] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=FS1 Parameters | |
;SEVCONFIELD OBJECT=FS1_PARAM | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2914sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2914sub1] | |
ParameterName=FS1 Flags | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=traction.fs1_flags | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=2 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=NOT_USED | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=FS1 Recycle | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
[2914sub2] | |
ParameterName=SRO delay | |
ParameterValue=0x0a | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=20 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=traction.sro_delay | |
[2915] | |
SubNumber=10 | |
ObjectType=9 | |
ParameterName=Motor to vehicle speed ratio | |
;SEVCONFIELD OBJECT=GEAR_RATIO | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2915sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x09 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2915sub1] | |
ParameterName=Vehicle speed numerator | |
ParameterValue=0x0020 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=traction.gear_ratio_numerator | |
[2915sub2] | |
ParameterName=Vehicle speed denominator | |
ParameterValue=0x0018 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=traction.gear_ratio_denominator | |
[2915sub3] | |
ParameterName=Ignore vehicle speed ratio for driveability profiles | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=misc.gear_ratio_ignore_for_profiles | |
[2915sub4] | |
ParameterName=User speed 1 numerator | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=misc.user_gear_ratio.numerator | |
[2915sub5] | |
ParameterName=User speed 1 denominator | |
ParameterValue=0x0001 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=misc.user_gear_ratio.denominator | |
[2915sub6] | |
ParameterName=Allow negative user speeds | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=misc.allow_negative_user_speeds | |
[2915sub7] | |
ParameterName=User speed 2 numerator | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=misc.user_2_gear_ratio.numerator | |
[2915sub8] | |
ParameterName=User speed 2 denominator | |
ParameterValue=0x0001 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=misc.user_2_gear_ratio.denominator | |
[2915sub9] | |
ParameterName=Allow negative user speeds for user speed 2 | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=misc.allow_negative_user_speeds_2 | |
[2916] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=Traction Motor Parameters | |
;SEVCONFIELD OBJECT=TRAC_MOTOR_PARAM | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2916sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2916sub1] | |
ParameterName=Traction Motor Rated Torque | |
ParameterValue=0x000061a8 | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=2000000 | |
PDOMapping=0 | |
DefaultValue=25000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.001 | |
;SEVCONFIELD UNITS=Nm | |
;SEVCONFIELD EEPROM=traction.motor_rated_torque | |
[2918] | |
ParameterName=Sequence Fault Mask (set bit to ignore input during sequence fault check) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=TRAC_SEQ_FLT_MASK | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD EEPROM=misc.seq_flt_mask | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=11 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Throttle direction | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Forward | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Reverse | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=FS1 | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=Inch Fwd | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Inch Rev | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=Deadman | |
;SEVCONFIELD BITMASK=0x40 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=7 | |
;SEVCONFIELD PARAMETERNAME=Belly | |
;SEVCONFIELD BITMASK=0x80 | |
;SEVCONFIELD BITSHIFT=0x7 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=8 | |
;SEVCONFIELD PARAMETERNAME=Belt Fwd | |
;SEVCONFIELD BITMASK=0x100 | |
;SEVCONFIELD BITSHIFT=0x8 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=9 | |
;SEVCONFIELD PARAMETERNAME=Belt Rev | |
;SEVCONFIELD BITMASK=0x200 | |
;SEVCONFIELD BITSHIFT=0x9 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=10 | |
;SEVCONFIELD PARAMETERNAME=Belt Stop | |
;SEVCONFIELD BITMASK=0x400 | |
;SEVCONFIELD BITSHIFT=0xA | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
[2919] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Inching parameters | |
;SEVCONFIELD OBJECT=GEAR_RATIO | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2919sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2919sub1] | |
ParameterName=Inch speed | |
ParameterValue=0x00c8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1500 | |
PDOMapping=0 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm | |
;SEVCONFIELD EEPROM=misc.traction_inch_speed | |
[2919sub2] | |
ParameterName=Inch timeout | |
ParameterValue=0x07d0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=5000 | |
PDOMapping=0 | |
DefaultValue=5000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=ms | |
;SEVCONFIELD EEPROM=misc.traction_inch_timeout | |
[2919sub3] | |
ParameterName=Inch throttle | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0x2000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.inch_throttle | |
[291A] | |
ParameterName=Traction Fault Clear Mask (set bit to ignore input during traction fault neutral check) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=TRAC_SEQ_FLT_MASK | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD EEPROM=misc.trc_flt_clear_mask | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=8 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Throttle direction | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Forward | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Reverse | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=FS1 | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=Inch Fwd | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Inch Rev | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=Deadman | |
;SEVCONFIELD BITMASK=0x40 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
;SEVCONFIELD SPLIT=7 | |
;SEVCONFIELD PARAMETERNAME=Belly | |
;SEVCONFIELD BITMASK=0x80 | |
;SEVCONFIELD BITSHIFT=0x7 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Check | |
;SEVCONFIELD 1=Ignore | |
[291C] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Gearbox oscillation reduction | |
;SEVCONFIELD OBJECT=GEARBOX_OSC_REDUCTION | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[291Csub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[291Csub1] | |
ParameterName=Torque to use slower ramp to | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
[291Csub2] | |
ParameterName=Gear mesh reduction ramp rate | |
ParameterValue=0x2710 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
[291E] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Speed Limit Configuration | |
;SEVCONFIELD OBJECT=MAX_SPEED_LIMIT_RAMP | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[291Esub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[291Esub1] | |
ParameterName=Maximum allowable speed limit increase rate | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0xFFFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm/s | |
[291Esub2] | |
ParameterName=Maximum allowable speed limit decrease rate | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0xFFFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm/s | |
[291F] | |
ParameterName=Creep Torque | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=500 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.001 | |
;SEVCONFIELD OBJECT=CREEP_TORQUE | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2920] | |
SubNumber=17 | |
ObjectType=9 | |
ParameterName=Traction baseline profile | |
;SEVCONFIELD OBJECT=DRIVEABILITY_PROFILE | |
;SEVCONFIELD SECTION=TractionDriveability | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2920sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x10 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=16 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2920sub1] | |
ParameterName=Maximum Torque applied during drive | |
ParameterValue=0x03e8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=traction.baseline_pro_0 | |
[2920sub2] | |
ParameterName=Maximum Torque applied during a direction change | |
ParameterValue=0x00c8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=500 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=traction.baseline_pro_1 | |
[2920sub3] | |
ParameterName=Maximum Torque applied when neutral braking | |
ParameterValue=0x0064 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=traction.baseline_pro_2 | |
[2920sub4] | |
ParameterName=Maximum Torque applied when footbraking | |
ParameterValue=0x00c8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=500 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=traction.baseline_pro_3 | |
[2920sub5] | |
ParameterName=Maximum Speed in forward direction | |
ParameterValue=0x157c | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=5000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm | |
;SEVCONFIELD EEPROM=traction.baseline_pro_4 | |
[2920sub6] | |
ParameterName=Maximum Speed in reverse direction | |
ParameterValue=0x1388 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm | |
;SEVCONFIELD EEPROM=traction.baseline_pro_5 | |
[2920sub7] | |
ParameterName=Ramp up rate during drive | |
ParameterValue=0x07d0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.baseline_pro_6 | |
[2920sub8] | |
ParameterName=Ramp up rate during direction change braking | |
ParameterValue=0x07d0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.baseline_pro_7 | |
[2920sub9] | |
ParameterName=Ramp up rate during neutral braking | |
ParameterValue=0x07d0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.baseline_pro_8 | |
[2920subA] | |
ParameterName=Ramp up rate during footbraking | |
ParameterValue=0x07d0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.baseline_pro_9 | |
[2920subB] | |
ParameterName=Ramp down rate during drive | |
ParameterValue=0x07d0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.baseline_pro_10 | |
[2920subC] | |
ParameterName=Ramp down rate during direction change braking | |
ParameterValue=0x07d0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.baseline_pro_11 | |
[2920subD] | |
ParameterName=Ramp down rate during neutral braking | |
ParameterValue=0x07d0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.baseline_pro_12 | |
[2920subE] | |
ParameterName=Ramp down rate during footbraking | |
ParameterValue=0x07d0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.baseline_pro_13 | |
[2920subF] | |
ParameterName=Speed limit ramp up rate when in torque mode | |
ParameterValue=0x1770 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=2000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm/s | |
;SEVCONFIELD EEPROM=traction.baseline_pro_14 | |
[2920sub10] | |
ParameterName=Speed limit ramp down rate when in torque mode | |
ParameterValue=0x03e8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=300 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm/s | |
;SEVCONFIELD EEPROM=traction.baseline_pro_15 | |
[2921] | |
SubNumber=17 | |
ObjectType=9 | |
ParameterName=Driveability Select 1 Profile | |
;SEVCONFIELD OBJECT=DRIVEABILITY_PROFILE | |
;SEVCONFIELD SECTION=TractionDriveability | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2921sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x10 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=16 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2921sub1] | |
ParameterName=Maximum Torque applied during drive | |
ParameterValue=0x03e8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_0 | |
[2921sub2] | |
ParameterName=Maximum Torque applied during a direction change | |
ParameterValue=0x03e8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=500 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_1 | |
[2921sub3] | |
ParameterName=Maximum Torque applied when neutral braking | |
ParameterValue=0x00c8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_2 | |
[2921sub4] | |
ParameterName=Maximum Torque applied when footbraking | |
ParameterValue=0x03e8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=500 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_3 | |
[2921sub5] | |
ParameterName=Maximum Speed in forward direction | |
ParameterValue=0x1388 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=5000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_4 | |
[2921sub6] | |
ParameterName=Maximum Speed in reverse direction | |
ParameterValue=0x1388 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_5 | |
[2921sub7] | |
ParameterName=Ramp up rate during drive | |
ParameterValue=0x1f40 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_6 | |
[2921sub8] | |
ParameterName=Ramp up rate during direction change braking | |
ParameterValue=0x0bb8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_7 | |
[2921sub9] | |
ParameterName=Ramp up rate during neutral braking | |
ParameterValue=0x0bb8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_8 | |
[2921subA] | |
ParameterName=Ramp up rate during footbraking | |
ParameterValue=0x0bb8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_9 | |
[2921subB] | |
ParameterName=Ramp down rate during drive | |
ParameterValue=0xc350 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_10 | |
[2921subC] | |
ParameterName=Ramp down rate during direction change braking | |
ParameterValue=0xc350 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_11 | |
[2921subD] | |
ParameterName=Ramp down rate during neutral braking | |
ParameterValue=0xc350 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_12 | |
[2921subE] | |
ParameterName=Ramp down rate during footbraking | |
ParameterValue=0xc350 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_13 | |
[2921subF] | |
ParameterName=Speed limit ramp up rate when in torque mode | |
ParameterValue=0x07d0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=2000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_14 | |
[2921sub10] | |
ParameterName=Speed limit ramp down rate when in torque mode | |
ParameterValue=0x012c | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=300 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_15 | |
[2922] | |
SubNumber=17 | |
ObjectType=9 | |
ParameterName=Driveability Select 2 Profile | |
;SEVCONFIELD OBJECT=DRIVEABILITY_PROFILE | |
;SEVCONFIELD SECTION=TractionDriveability | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2922sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x10 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=16 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2922sub1] | |
ParameterName=Maximum Torque applied during drive | |
ParameterValue=0x03e8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_0 | |
[2922sub2] | |
ParameterName=Maximum Torque applied during a direction change | |
ParameterValue=0x03e8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=500 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_1 | |
[2922sub3] | |
ParameterName=Maximum Torque applied when neutral braking | |
ParameterValue=0x00c8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_2 | |
[2922sub4] | |
ParameterName=Maximum Torque applied when footbraking | |
ParameterValue=0x03e8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=500 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_3 | |
[2922sub5] | |
ParameterName=Maximum Speed in forward direction | |
ParameterValue=0x1388 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=5000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_4 | |
[2922sub6] | |
ParameterName=Maximum Speed in reverse direction | |
ParameterValue=0x1388 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_5 | |
[2922sub7] | |
ParameterName=Ramp up rate during drive | |
ParameterValue=0x1f40 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_6 | |
[2922sub8] | |
ParameterName=Ramp up rate during direction change braking | |
ParameterValue=0x0bb8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_7 | |
[2922sub9] | |
ParameterName=Ramp up rate during neutral braking | |
ParameterValue=0x0bb8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_8 | |
[2922subA] | |
ParameterName=Ramp up rate during footbraking | |
ParameterValue=0x0bb8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_9 | |
[2922subB] | |
ParameterName=Ramp down rate during drive | |
ParameterValue=0xc350 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_10 | |
[2922subC] | |
ParameterName=Ramp down rate during direction change braking | |
ParameterValue=0xc350 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_11 | |
[2922subD] | |
ParameterName=Ramp down rate during neutral braking | |
ParameterValue=0xc350 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_12 | |
[2922subE] | |
ParameterName=Ramp down rate during footbraking | |
ParameterValue=0xc350 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_13 | |
[2922subF] | |
ParameterName=Speed limit ramp up rate when in torque mode | |
ParameterValue=0x07d0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=2000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_14 | |
[2922sub10] | |
ParameterName=Speed limit ramp down rate when in torque mode | |
ParameterValue=0x012c | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=300 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm/s | |
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_15 | |
[2928] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Seat Regen Parameters | |
;SEVCONFIELD OBJECT=SEAT_REGEN | |
;SEVCONFIELD SECTION=SeatConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2928sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=4 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2928sub1] | |
ParameterName=Maximum Torque applied during seat activated braking | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=500 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=misc.seat_max_braking_torque | |
[2928sub2] | |
ParameterName=Ramp up rate during seat activated braking | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=misc.seat_regen_ramp_up_rate | |
[2928sub3] | |
ParameterName=Ramp down rate during seat activated braking | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=%/s | |
;SEVCONFIELD EEPROM=misc.seat_regen_ramp_down_rate | |
[2930] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Controlled Roll Off parameters | |
;SEVCONFIELD OBJECT=ROLL_OFF_PARAM | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2930sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2930sub1] | |
ParameterName=Controlled Roll Off | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=traction.roll_off_enabled | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2930sub2] | |
ParameterName=Maximum torque applied in Controlled Roll Off | |
ParameterValue=0x03e8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32000 | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=traction.roll_off_maximum_torque | |
[2930sub3] | |
ParameterName=Maximum speed allowed in Controlled Roll Off | |
ParameterValue=0x0064 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=rpm | |
;SEVCONFIELD EEPROM=traction.roll_off_maximum_speed | |
[2931] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Drivability Select Profile Triggers | |
;SEVCONFIELD OBJECT=ROLL_OFF_PARAM | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2931sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2931sub1] | |
ParameterName=Drivability Select 1 Profile Triggers | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x0F | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=misc.drv_sel_triggers_pro1 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=4 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Low BDI activates profile | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Low speed activates profile | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Service interval activates profile | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Battery Electrolyte Low activates profile | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
[2931sub2] | |
ParameterName=Drivability Select 2 Profile Triggers | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x0F | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=misc.drv_sel_triggers_pro2 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=4 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Low BDI activates profile | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Low speed activates profile | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Service interval activates profile | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Battery Electrolyte Low activates profile | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
[2931sub3] | |
ParameterName=Use active drivability values only | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=misc.use_active_profile_only | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Use lowest values from all active profiles | |
;SEVCONFIELD 1=Use active profile only | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2933] | |
ParameterName=Torque demand S-curve | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=10 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=TORQUE_S_CURVE | |
;SEVCONFIELD SECTION=TractionConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[29A0] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Odometer Counter | |
;SEVCONFIELD OBJECT=ODOMETER_COUNTER | |
;SEVCONFIELD SECTION=OdometerCounter | |
;SEVCONFIELD CATEGORY=LOGGING | |
[29A0sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[29A0sub1] | |
ParameterName=Odometer distance in Km | |
ParameterValue=0x00006df4 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=km | |
[29A0sub2] | |
ParameterName=Odometer distance in Km | |
ParameterValue=0x0000044b | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=km | |
[29A0sub3] | |
ParameterName=Odometer distance in miles | |
ParameterValue=0x000002aa | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=miles | |
[29A1] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Trip Meter Counter | |
;SEVCONFIELD OBJECT=TRIP_METER_COUNTER | |
;SEVCONFIELD SECTION=OdometerCounter | |
;SEVCONFIELD CATEGORY=LOGGING | |
[29A1sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[29A1sub1] | |
ParameterName=Trip Distance in km | |
ParameterValue=0x00006df4 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit= | |
HighLimit=0xFFFFFFFF | |
PDOMapping=1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=km | |
[29A1sub2] | |
ParameterName=Trip Distance in km | |
ParameterValue=0x0000044b | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=km | |
[29A1sub3] | |
ParameterName=Trip Distance in miles | |
ParameterValue=0x000002aa | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=miles | |
[2A00] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=General Pump Features | |
;SEVCONFIELD OBJECT=PUMP_PARAM | |
;SEVCONFIELD SECTION=PumpConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2A00sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2A00sub1] | |
ParameterName=Pump Flags | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=3 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD EEPROM=pump.general_flags | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=9 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=BDI Inhibit | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Ignored | |
;SEVCONFIELD 1=Inhibits pump | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Drive Enable | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Ignored | |
;SEVCONFIELD 1=Disables pump | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Seat Switch | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Ignored | |
;SEVCONFIELD 1=Disables pump | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Line Contactor | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Ignored | |
;SEVCONFIELD 1=Disables pump | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=Add Power Steer Speed to Pump Speed | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Minimum speed without trigger | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=Pump to stop on low battery | |
;SEVCONFIELD BITMASK=0x40 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=7 | |
;SEVCONFIELD PARAMETERNAME=Use power steer speed as minimum pump speed | |
;SEVCONFIELD BITMASK=0x80 | |
;SEVCONFIELD BITSHIFT=0x7 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=8 | |
;SEVCONFIELD PARAMETERNAME=Use power steer motor as 2nd pump motor | |
;SEVCONFIELD BITMASK=0x100 | |
;SEVCONFIELD BITSHIFT=0x8 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
[2A01] | |
SubNumber=6 | |
ObjectType=9 | |
ParameterName=Pump Motor Parameters | |
;SEVCONFIELD OBJECT=PUMP_MOTOR_PARAM | |
;SEVCONFIELD SECTION=PumpConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2A01sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=5 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2A01sub1] | |
ParameterName=Pump Motor Maximum Speed | |
ParameterValue=0x09c4 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=2500 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=pump.motor_max_speed | |
[2A01sub2] | |
ParameterName=Pump Motor Minimum Speed | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=pump.motor_min_speed | |
[2A01sub3] | |
ParameterName=Pump Motor Acceleration Rate | |
ParameterValue=0x0fa0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=rpm/s | |
;SEVCONFIELD EEPROM=pump.motor_acceleration | |
[2A01sub4] | |
ParameterName=Pump Motor Deceleration Rate | |
ParameterValue=0x0fa0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=rpm/s | |
;SEVCONFIELD EEPROM=pump.motor_deceleration | |
[2A01sub5] | |
ParameterName=Maximum Torque Applied in Baseline Profile | |
ParameterValue=0x03e8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.001 | |
;SEVCONFIELD UNITS= | |
;SEVCONFIELD EEPROM=misc.pump_base_torque_limit | |
[2A10] | |
SubNumber=13 | |
ObjectType=9 | |
ParameterName=Pump Throttle 1 parameters | |
;SEVCONFIELD OBJECT=PUMP_THROTTLE_PARAM | |
;SEVCONFIELD SECTION=PUMPCONFIG | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2A10sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x0c | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=12 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2A10sub1] | |
ParameterName=Priority Level / Additive | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD EEPROM=pump.throttles_0_priority | |
[2A10sub2] | |
ParameterName=Input Characteristic | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=3 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=1 | |
;SEVCONFIELD NUMBER_FORMAT=4 | |
;SEVCONFIELD 0=User Defd | |
;SEVCONFIELD 1=Linear | |
;SEVCONFIELD 2=Curved | |
;SEVCONFIELD 3=Crawl | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD EEPROM=pump.throttles_0_ip_char | |
[2A10sub3] | |
ParameterName=Pump throttle 1 Start Voltage | |
ParameterValue=0x000a | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=16 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=pump.throttles_0_ip_start_voltage | |
[2A10sub4] | |
ParameterName=Pump throttle 1 Start Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_0_ip_start_value | |
[2A10sub5] | |
ParameterName=Pump throttle 1 End Voltage | |
ParameterValue=0x2710 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=1309 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=pump.throttles_0_ip_end_voltage | |
[2A10sub6] | |
ParameterName=Pump throttle 1 End Value | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_0_ip_end_value | |
[2A10sub7] | |
ParameterName=User Defined Char Pt 1 Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=9830 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_0_ud_map_0_voltage | |
[2A10sub8] | |
ParameterName=User Defined Char Pt 1 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=9830 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_0_ud_map_0_value | |
[2A10sub9] | |
ParameterName=User Defined Char Pt 2 Voltage | |
ParameterValue=0x8000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=19660 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_0_ud_map_1_voltage | |
[2A10subA] | |
ParameterName=User Defined Char Pt 2 Value | |
ParameterValue=0x8000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_0_ud_map_1_value | |
[2A10subB] | |
ParameterName=User Defined Char Pt 3 Voltage | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=52428 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_0_ud_map_2_voltage | |
[2A10subC] | |
ParameterName=User Defined Char Pt 3 Value | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=62258 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_0_ud_map_2_value | |
[2A11] | |
SubNumber=13 | |
ObjectType=9 | |
ParameterName=Pump Throttle 2 parameters | |
;SEVCONFIELD OBJECT=PUMP_THROTTLE_PARAM | |
;SEVCONFIELD SECTION=PUMPCONFIG | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2A11sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x0c | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=12 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2A11sub1] | |
ParameterName=Priority Level / Additive | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD EEPROM=pump.throttles_1_priority | |
[2A11sub2] | |
ParameterName=Input Characteristic | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=3 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD NUMBER_FORMAT=4 | |
;SEVCONFIELD 0=User Defd | |
;SEVCONFIELD 1=Linear | |
;SEVCONFIELD 2=Curved | |
;SEVCONFIELD 3=Crawl | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD EEPROM=pump.throttles_1_ip_char | |
[2A11sub3] | |
ParameterName=Pump throttle 2 Start Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=16 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=pump.throttles_1_ip_start_voltage | |
[2A11sub4] | |
ParameterName=Pump throttle 2 Start Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_1_ip_start_value | |
[2A11sub5] | |
ParameterName=Pump throttle 2 End Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=1309 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=pump.throttles_1_ip_end_voltage | |
[2A11sub6] | |
ParameterName=Pump throttle 2 End Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_1_ip_end_value | |
[2A11sub7] | |
ParameterName=User Defined Char Pt 1 Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=9830 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_1_ud_map_0_voltage | |
[2A11sub8] | |
ParameterName=User Defined Char Pt 1 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=9830 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_1_ud_map_0_value | |
[2A11sub9] | |
ParameterName=User Defined Char Pt 2 Voltage | |
ParameterValue=0x8000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=19660 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_1_ud_map_1_voltage | |
[2A11subA] | |
ParameterName=User Defined Char Pt 2 Value | |
ParameterValue=0x8000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_1_ud_map_1_value | |
[2A11subB] | |
ParameterName=User Defined Char Pt 3 Voltage | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=52428 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_1_ud_map_2_voltage | |
[2A11subC] | |
ParameterName=User Defined Char Pt 3 Value | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=62258 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52590218966964E-05 | |
;SEVCONFIELD EEPROM=pump.throttles_1_ud_map_2_value | |
[2A20] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Pump Switch 1 parameters | |
;SEVCONFIELD OBJECT=PUMP_SWITCH_PARAM | |
;SEVCONFIELD SECTION=PUMPCONFIG | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2A20sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2A20sub1] | |
ParameterName=Priority Level / Additive | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD EEPROM=pump.switches_0_priority | |
[2A20sub2] | |
ParameterName=Pump Switch 1 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=pump.switches_0_value | |
[2A21] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Pump Switch 2 parameters | |
;SEVCONFIELD OBJECT=PUMP_SWITCH_PARAM | |
;SEVCONFIELD SECTION=PUMPCONFIG | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2A21sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2A21sub1] | |
ParameterName=Priority Level / Additive | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD EEPROM=pump.switches_1_priority | |
[2A21sub2] | |
ParameterName=Pump Switch 2 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=pump.switches_1_value | |
[2A22] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Pump Switch 3 parameters | |
;SEVCONFIELD OBJECT=PUMP_SWITCH_PARAM | |
;SEVCONFIELD SECTION=PUMPCONFIG | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2A22sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2A22sub1] | |
ParameterName=Priority Level / Additive | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD EEPROM=pump.switches_2_priority | |
[2A22sub2] | |
ParameterName=Pump Switch 3 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=pump.switches_2_value | |
[2A23] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Pump Switch 4 parameters | |
;SEVCONFIELD OBJECT=PUMP_SWITCH_PARAM | |
;SEVCONFIELD SECTION=PUMPCONFIG | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2A23sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2A23sub1] | |
ParameterName=Priority Level / Additive | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD EEPROM=pump.switches_3_priority | |
[2A23sub2] | |
ParameterName=Pump Switch 4 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=pump.switches_3_value | |
[2A24] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Pump Switch 5 parameters | |
;SEVCONFIELD OBJECT=PUMP_SWITCH_PARAM | |
;SEVCONFIELD SECTION=PUMPCONFIG | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2A24sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2A24sub1] | |
ParameterName=Priority Level / Additive | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD EEPROM=pump.switches_4_priority | |
[2A24sub2] | |
ParameterName=Pump Switch 5 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=pump.switches_4_value | |
[2A25] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Pump Switch 6 parameters | |
;SEVCONFIELD OBJECT=PUMP_SWITCH_PARAM | |
;SEVCONFIELD SECTION=PUMPCONFIG | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2A25sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2A25sub1] | |
ParameterName=Priority Level / Additive | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD EEPROM=pump.switches_5_priority | |
[2A25sub2] | |
ParameterName=Pump Switch 6 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=pump.switches_5_value | |
[2A26] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Pump Switch 7 parameters | |
;SEVCONFIELD OBJECT=PUMP_SWITCH_PARAM | |
;SEVCONFIELD SECTION=PUMPCONFIG | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2A26sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2A26sub1] | |
ParameterName=Priority Level / Additive | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD EEPROM=pump.switches_6_priority | |
[2A26sub2] | |
ParameterName=Pump Switch 7 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=pump.switches_6_value | |
[2A30] | |
SubNumber=13 | |
ObjectType=9 | |
ParameterName=Pump Driveability Profile 1 parameters | |
;SEVCONFIELD OBJECT=PUMP_PROFILE_PARAM | |
;SEVCONFIELD SECTION=PUMPCONFIG | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2A30sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x0c | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=12 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2A30sub1] | |
ParameterName=Maximum Pump Motor Acceleration Rate | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=10000 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=rpm/s | |
;SEVCONFIELD EEPROM=misc.pump_drv1_accel_rate | |
[2A30sub2] | |
ParameterName=Maximum Pump Motor Deceleration Rate | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=10000 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=rpm/s | |
;SEVCONFIELD EEPROM=misc.pump_drv1_decel_rate | |
[2A30sub3] | |
ParameterName=Maximum Pump Throttle 1 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv1_value0 | |
[2A30sub4] | |
ParameterName=Maximum Pump Throttle 2 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv1_value0 | |
[2A30sub5] | |
ParameterName=Maximum Pump Switch 1 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv1_value0 | |
[2A30sub6] | |
ParameterName=Maximum Pump Switch 2 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv1_value0 | |
[2A30sub7] | |
ParameterName=Maximum Pump Switch 3 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv1_value0 | |
[2A30sub8] | |
ParameterName=Maximum Pump Switch 4 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv1_value0 | |
[2A30sub9] | |
ParameterName=Maximum Pump Switch 5 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv1_value0 | |
[2A30subA] | |
ParameterName=Maximum Pump Switch 6 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv1_value0 | |
[2A30subB] | |
ParameterName=Maximum Pump Switch 7 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv1_value0 | |
[2A30subC] | |
ParameterName=Maximum Torque Applied in Pump Driveability Profile 1 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.001 | |
;SEVCONFIELD UNITS= | |
;SEVCONFIELD EEPROM=misc.pump_drv1_torque_limit | |
[2A31] | |
SubNumber=13 | |
ObjectType=9 | |
ParameterName=Pump Driveability Profile 2 parameters | |
;SEVCONFIELD OBJECT=PUMP_PROFILE_PARAM | |
;SEVCONFIELD SECTION=PUMPCONFIG | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2A31sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x0c | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=12 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2A31sub1] | |
ParameterName=Maximum Pump Motor Acceleration Rate | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=10000 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=rpm/s | |
;SEVCONFIELD EEPROM=misc.pump_drv2_accel_rate | |
[2A31sub2] | |
ParameterName=Maximum Pump Motor Deceleration Rate | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=10000 | |
PDOMapping=0 | |
DefaultValue=10000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=rpm/s | |
;SEVCONFIELD EEPROM=misc.pump_drv2_decel_rate | |
[2A31sub3] | |
ParameterName=Maximum Pump Throttle 1 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv2_value0 | |
[2A31sub4] | |
ParameterName=Maximum Pump Throttle 2 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv2_value0 | |
[2A31sub5] | |
ParameterName=Maximum Pump Switch 1 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv2_value0 | |
[2A31sub6] | |
ParameterName=Maximum Pump Switch 2 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv2_value0 | |
[2A31sub7] | |
ParameterName=Maximum Pump Switch 3 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv2_value0 | |
[2A31sub8] | |
ParameterName=Maximum Pump Switch 4 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv2_value0 | |
[2A31sub9] | |
ParameterName=Maximum Pump Switch 5 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv2_value0 | |
[2A31subA] | |
ParameterName=Maximum Pump Switch 6 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv2_value0 | |
[2A31subB] | |
ParameterName=Maximum Pump Switch 7 Value | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
;SEVCONFIELD EEPROM=misc.pump_drv2_value0 | |
[2A31subC] | |
ParameterName=Maximum Torque Applied in Pump Driveability Profile 2 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.001 | |
;SEVCONFIELD UNITS= | |
;SEVCONFIELD EEPROM=misc.pump_drv2_torque_limit | |
[2B00] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=General Power steer features | |
;SEVCONFIELD OBJECT=PSTEER_PARAM | |
;SEVCONFIELD SECTION=PsteerConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2B00sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2B00sub1] | |
ParameterName=Power steer delay | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=pwr_str.power_steer_delay | |
[2B00sub2] | |
ParameterName=Power steer trigger (set bit to enable trigger) | |
ParameterValue=0x07 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=pwr_str.internal_trigger | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=6 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Vehicle Moving | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=FS1 Switch | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Direction | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Seat Switch | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=Footbrake | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=INCH switches | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
[2B01] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Power Steer Motor Speed | |
;SEVCONFIELD OBJECT=PSTEER_MOTOR_PARAM | |
;SEVCONFIELD SECTION=PsteerConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2B01sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2B01sub1] | |
ParameterName=Power Steer Motor Speed | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=500 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=pwr_str.speed_demand | |
[2B01sub2] | |
ParameterName=Power Steer Motor Acceleration Rate | |
ParameterValue=0x0100 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=500 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=rpm/s | |
;SEVCONFIELD EEPROM=pwr_str.acceleration | |
[2B01sub3] | |
ParameterName=Power Steer Motor Deceleration Rate | |
ParameterValue=0x0100 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=10 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=500 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=rpm/s | |
;SEVCONFIELD EEPROM=pwr_str.deceleration | |
[2B02] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Variable Assist Power Steering | |
;SEVCONFIELD OBJECT=PSTEER_VAR_ASSIST_PARAM | |
;SEVCONFIELD SECTION=PsteerConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2B02sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2B02sub1] | |
ParameterName=Power Steering Assist Maximum Speed | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=RPM | |
[2B02sub2] | |
ParameterName=Power Steering Assist Cutback Factor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=3.05185094759972E-05 | |
[2C00] | |
ParameterName=Nominal battery voltage | |
ParameterValue=0x0500 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=384 | |
HighLimit=3072 | |
PDOMapping=0 | |
DefaultValue=0x0300 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD OBJECT=NOM_BATT_V | |
;SEVCONFIELD SECTION=BatteryApplication | |
;SEVCONFIELD EEPROM=battery.nominal_battery | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2C01] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Battery over voltage protection | |
;SEVCONFIELD OBJECT=BATT_OVER_V_PROT | |
;SEVCONFIELD SECTION=BatteryProtection | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2C01sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2C01sub1] | |
ParameterName=Over voltage start cutback | |
ParameterValue=0x0640 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0x03A0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=battery.high_v_start_cutback | |
[2C01sub2] | |
ParameterName=Over voltage limit | |
ParameterValue=0x0690 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0x0410 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=battery.high_v_limit | |
[2C02] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Battery under voltage protection | |
;SEVCONFIELD OBJECT=BATT_UNDER_V_PROT | |
;SEVCONFIELD SECTION=BatteryProtection | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2C02sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2C02sub1] | |
ParameterName=Under voltage start cutback | |
ParameterValue=0x04b0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0x01c0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=battery.low_v_start_cutback | |
[2C02sub2] | |
ParameterName=Under voltage limit | |
ParameterValue=0x0490 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0x01a0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=battery.low_v_limit | |
[2C03] | |
ParameterName=Battery Protection Delay | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=10 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.1 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD OBJECT=NOM_BATT_V | |
;SEVCONFIELD SECTION=BatteryApplication | |
;SEVCONFIELD EEPROM=battery.protection_delay | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2C30] | |
SubNumber=9 | |
ObjectType=9 | |
ParameterName=BDI parameters | |
;SEVCONFIELD OBJECT=BDI_PARAM | |
;SEVCONFIELD SECTION=BDISetup | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2C30sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x08 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=7 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2C30sub1] | |
ParameterName=BDI Flags | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=battery.bdi_flags | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=3 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Traction | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Pump | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=BDI Map | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
[2C30sub2] | |
ParameterName=Reset voltage (V) | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=210 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.01 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=battery.bdi_reset_voltage_level | |
[2C30sub3] | |
ParameterName=Discharge voltage (V) | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=173 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.01 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=battery.bdi_discharge_voltage_level | |
[2C30sub4] | |
ParameterName=Cutout level (%) | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=100 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=battery.bdi_cutout_level | |
[2C30sub5] | |
ParameterName=Warning level (%) | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=100 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=battery.bdi_warning_level | |
[2C30sub6] | |
ParameterName=Cell count | |
ParameterValue=0x50 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=24 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=battery.cell_count | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2C30sub7] | |
ParameterName=BDI Discharge Rate | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=16800 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.001 | |
;SEVCONFIELD UNITS=s/% | |
;SEVCONFIELD EEPROM=battery.bdi_discharge | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2C30sub8] | |
ParameterName=BDI Reset Enable Level | |
ParameterValue=0x64 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=100 | |
PDOMapping=0 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=battery.bdi_reset_enable_level | |
[2C31] | |
SubNumber=11 | |
ObjectType=9 | |
ParameterName=BDI Remaining Charge Map | |
;SEVCONFIELD OBJECT=BDI_REMAINING_MAP | |
;SEVCONFIELD SECTION=BDISetup | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2C31sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x0a | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=16 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2C31sub1] | |
ParameterName=Pt 1 Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=42 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[0].battery_voltage | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2C31sub2] | |
ParameterName=Pt1 BDI Remaining Charge | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=10 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[0].BDI_Charge | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2C31sub3] | |
ParameterName=Pt 2 Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=44 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[1].battery_voltage | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2C31sub4] | |
ParameterName=Pt 2 BDI Remaining Charge | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=30 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[1].BDI_Charge | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2C31sub5] | |
ParameterName=Pt 3 Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=46 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[2].battery_voltage | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2C31sub6] | |
ParameterName=Pt 3 BDI Remaining Charge | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=50 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[2].BDI_Charge | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2C31sub7] | |
ParameterName=Pt 4 Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=48 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[3].battery_voltage | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2C31sub8] | |
ParameterName=Pt 4 BDI Remaining Charge | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=70 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[3].BDI_Charge | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2C31sub9] | |
ParameterName=Pt 5 Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=52 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[4].battery_voltage | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2C31subA] | |
ParameterName=Pt 5 BDI Remaining Charge | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[4].BDI_Charge | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[2D00] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Contactor Output Configuration | |
;SEVCONFIELD OBJECT=CONTACTOR_PARAM | |
;SEVCONFIELD SECTION=VehicleConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2D00sub0] | |
ParameterName=Number of parameters | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2D00sub1] | |
ParameterName=Pull-In Voltage | |
ParameterValue=0x50 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=48 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=contactor.pull_in_voltage | |
[2D00sub2] | |
ParameterName=Pull-In Time | |
ParameterValue=0x64 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.01 | |
;SEVCONFIELD UNITS=Seconds | |
;SEVCONFIELD EEPROM=contactor.pull_in_time | |
[2D00sub3] | |
ParameterName=Hold-In Voltage | |
ParameterValue=0x50 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=36 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=contactor.hold_in_voltage | |
[2D01] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Voltage Control Enable | |
;SEVCONFIELD OBJECT=VOLTAGE_CTRL_ENABLE | |
;SEVCONFIELD SECTION=VehicleConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2D01sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2D01sub1] | |
ParameterName=Voltage Control Enable for Contactor Drives 1..8 | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0xFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=contactor.voltage_control_enable_0 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=8 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Line Contactor | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Pump Contactor | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Power Steer Contactor | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Electromechanical Brake | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=External LED | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Traction Motor Cooling Fan | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=Buzzer | |
;SEVCONFIELD BITMASK=0x40 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=7 | |
;SEVCONFIELD PARAMETERNAME=Horn | |
;SEVCONFIELD BITMASK=0x80 | |
;SEVCONFIELD BITSHIFT=0x7 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
[2D01sub2] | |
ParameterName=Voltage Control Enable for Contactor Drives 9..16 | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0xFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=contactor.voltage_control_enable_1 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=7 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Lights | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Service | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Motor Isolation | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Precharge Output | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=Belt Electromechanical Brake | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Belt ChangeOver Contactor | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=Electro-mechanical Park brake | |
;SEVCONFIELD BITMASK=0x40 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
[2D02] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Reduce to Hold Level Enable | |
;SEVCONFIELD OBJECT=REDUCE_TO_HOLD_LEVEL | |
;SEVCONFIELD SECTION=VehicleConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2D02sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2D02sub1] | |
ParameterName=Reduce to Hold Level Enable for Contactor Drives 1..8 | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0xFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=contactor.reduction_enable_0 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=8 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Line Contactor | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Pump Contactor | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Power Steer Contactor | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Electromechanical Brake | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=External LED | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Traction Motor Cooling Fan | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=Buzzer | |
;SEVCONFIELD BITMASK=0x40 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=7 | |
;SEVCONFIELD PARAMETERNAME=Horn | |
;SEVCONFIELD BITMASK=0x80 | |
;SEVCONFIELD BITSHIFT=0x7 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
[2D02sub2] | |
ParameterName=Reduce to Hold Level Enable for Contactor Drives 9..16 | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0xFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=contactor.reduction_enable_1 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=7 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Lights | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Service | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Motor Isolation | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Precharge Output | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=Belt Electromechanical Brake | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Belt ChangeOver Contactor | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=Electro-mechanical Park brake | |
;SEVCONFIELD BITMASK=0x40 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
[2E00] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Display Configuration | |
;SEVCONFIELD OBJECT=DISPLAY_CONFIGURATION | |
;SEVCONFIELD SECTION=VehicleConfig | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[2E00sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[2E00sub1] | |
ParameterName=Display Type | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=misc.display_config_type | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=No Display | |
;SEVCONFIELD 1=Smartview | |
[2E00sub2] | |
ParameterName=Display Information | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=7 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=misc.display_config_hours_count | |
;SEVCONFIELD NUMBER_FORMAT=7 | |
;SEVCONFIELD 0=Key hours | |
;SEVCONFIELD 1=Traction hours | |
;SEVCONFIELD 2=Pump hours | |
;SEVCONFIELD 3=Charging hours | |
;SEVCONFIELD 4=Real Speed | |
;SEVCONFIELD 5=Real Speed & Key hrs | |
;SEVCONFIELD 6=Real Speed & Traction hrs | |
;SEVCONFIELD 7=Real Speed & Pump hrs | |
[3000] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=Local Motor VPDO Mapping | |
;SEVCONFIELD OBJECT=LOCAL_MOTOR_MAPPING | |
;SEVCONFIELD SECTION=LocalMotorMapping | |
;SEVCONFIELD DUMMY_VPDO=0x20FF | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[3000sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.motor_number | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3000sub1] | |
ParameterName=Local Motor 1 VPDO Mapping | |
ParameterValue=0x2020 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8224 | |
HighLimit=8447 | |
PDOMapping=0 | |
DefaultValue=0x2020 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.motor_0 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3200] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Analog output VPDO Mapping | |
;SEVCONFIELD OBJECT=LOCAL_ALG_OUT_MAPPING | |
;SEVCONFIELD SECTION=LocalAOMapping | |
;SEVCONFIELD DUMMY_VPDO=0x24FF | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[3200sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=3 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.alg_out_number | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3200sub1] | |
ParameterName=Analog Output 1 VPDO Mapping | |
ParameterValue=0x2400 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=9216 | |
HighLimit=9471 | |
PDOMapping=0 | |
DefaultValue=0x2400 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.alg_out_0 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3200sub2] | |
ParameterName=Analog Output 2 VPDO Mapping | |
ParameterValue=0x24ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=9216 | |
HighLimit=9471 | |
PDOMapping=0 | |
DefaultValue=0x2420 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.alg_out_1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3200sub3] | |
ParameterName=Analog Output 3 VPDO Mapping | |
ParameterValue=0x24ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=9216 | |
HighLimit=9471 | |
PDOMapping=0 | |
DefaultValue=0x2440 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.alg_out_2 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3300] | |
SubNumber=14 | |
ObjectType=9 | |
ParameterName=Digital input VPDO Mapping | |
;SEVCONFIELD OBJECT=LOCAL_DIG_IN_MAPPING | |
;SEVCONFIELD SECTION=LocalDIMapping | |
;SEVCONFIELD DUMMY_VPDO=0x21FF | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[3300sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=13 | |
PDOMapping=0 | |
DefaultValue=4 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.dig_in_number | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3300sub1] | |
ParameterName=Digital Input 1 VPDO Mapping | |
ParameterValue=0x2121 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8448 | |
HighLimit=8703 | |
PDOMapping=0 | |
DefaultValue=0x2121 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.dig_in_0 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3300sub2] | |
ParameterName=Digital Input 2 VPDO Mapping | |
ParameterValue=0x2122 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8448 | |
HighLimit=8703 | |
PDOMapping=0 | |
DefaultValue=0x2122 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.dig_in_1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3300sub3] | |
ParameterName=Digital Input 3 VPDO Mapping | |
ParameterValue=0x2123 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8448 | |
HighLimit=8703 | |
PDOMapping=0 | |
DefaultValue=0x2123 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.dig_in_2 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3300sub4] | |
ParameterName=Digital Input 4 VPDO Mapping | |
ParameterValue=0x21ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8448 | |
HighLimit=8703 | |
PDOMapping=0 | |
DefaultValue=0x2124 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.dig_in_3 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3300sub5] | |
ParameterName=Digital Input 5 VPDO Mapping | |
ParameterValue=0x21ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8448 | |
HighLimit=8703 | |
PDOMapping=0 | |
DefaultValue=0x2125 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.dig_in_4 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3300sub6] | |
ParameterName=Digital Input 6 VPDO Mapping | |
ParameterValue=0x21ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8448 | |
HighLimit=8703 | |
PDOMapping=0 | |
DefaultValue=0x2126 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.dig_in_5 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3300sub7] | |
ParameterName=Digital Input 7 VPDO Mapping | |
ParameterValue=0x21ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8448 | |
HighLimit=8703 | |
PDOMapping=0 | |
DefaultValue=0x2140 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.dig_in_6 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3300sub8] | |
ParameterName=Digital Input 8 VPDO Mapping | |
ParameterValue=0x21ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8448 | |
HighLimit=8703 | |
PDOMapping=0 | |
DefaultValue=0x2160 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.dig_in_7 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3300sub9] | |
ParameterName=Digital Input 9 VPDO Mapping | |
ParameterValue=0x21ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8448 | |
HighLimit=8703 | |
PDOMapping=0 | |
DefaultValue=0x21FF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.dig_in_8 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3300subA] | |
ParameterName=Digital Input 10 VPDO Mapping | |
ParameterValue=0x21ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8448 | |
HighLimit=8703 | |
PDOMapping=0 | |
DefaultValue=0x21FF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.dig_in_9 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3300subB] | |
ParameterName=Digital Input 11 VPDO Mapping | |
ParameterValue=0x21ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8448 | |
HighLimit=8703 | |
PDOMapping=0 | |
DefaultValue=0x21FF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.dig_in_10 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3300subC] | |
ParameterName=Digital Input 12 VPDO Mapping | |
ParameterValue=0x21ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8448 | |
HighLimit=8703 | |
PDOMapping=0 | |
DefaultValue=0x21FF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.dig_in_11 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3300subD] | |
ParameterName=Digital Input 13 VPDO Mapping | |
ParameterValue=0x21ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8448 | |
HighLimit=8703 | |
PDOMapping=0 | |
DefaultValue=0x21FF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.dig_in_12 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3400] | |
SubNumber=6 | |
ObjectType=9 | |
ParameterName=Analog input VPDO Mapping | |
;SEVCONFIELD OBJECT=LOCAL_ALG_IN_MAPPING | |
;SEVCONFIELD SECTION=LocalAIMapping | |
;SEVCONFIELD DUMMY_VPDO=0x22FF | |
;SEVCONFIELD MASTER=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[3400sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=5 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.alg_in_number | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3400sub1] | |
ParameterName=Analog Input 1 VPDO Mapping | |
ParameterValue=0x2220 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8736 | |
HighLimit=8959 | |
PDOMapping=0 | |
DefaultValue=0x2220 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.alg_in_0 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3400sub2] | |
ParameterName=Analog Input 2 VPDO Mapping | |
ParameterValue=0x22ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8736 | |
HighLimit=8959 | |
PDOMapping=0 | |
DefaultValue=0x2221 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.alg_in_1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3400sub3] | |
ParameterName=Analog Input 3 VPDO Mapping | |
ParameterValue=0x22ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8736 | |
HighLimit=8959 | |
PDOMapping=0 | |
DefaultValue=0x2222 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.alg_in_2 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3400sub4] | |
ParameterName=Analog Input 4 VPDO Mapping | |
ParameterValue=0x22ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8736 | |
HighLimit=8959 | |
PDOMapping=0 | |
DefaultValue=0x22FF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.alg_in_3 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[3400sub5] | |
ParameterName=Analog Input 5 VPDO Mapping | |
ParameterValue=0x22ff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=8736 | |
HighLimit=8959 | |
PDOMapping=0 | |
DefaultValue=0x22FF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=vpdos.alg_in_4 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4000] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=Logging Control | |
;SEVCONFIELD OBJECT=ALL_LOGS_CTRL | |
;SEVCONFIELD SECTION=LogsReset | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4000sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4000sub1] | |
ParameterName=Reset (write to reset all logs) | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=5 | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Reset | |
;SEVCONFIELD 1=Reset | |
;SEVCONFIELD COMMS_TIMEOUT=20000 | |
[4100] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=System FIFO Control | |
;SEVCONFIELD OBJECT=SYSTEM_FIFO_CTRL | |
;SEVCONFIELD SECTION=SystemLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4100sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4100sub1] | |
ParameterName=Reset (write to reset system FIFO) | |
ObjectType=7 | |
DataType=1 | |
AccessType=wo | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Reset | |
;SEVCONFIELD 1=Reset | |
;SEVCONFIELD COMMS_TIMEOUT=20000 | |
[4100sub2] | |
ParameterName=Number of items in System FIFO | |
ParameterValue=0x000a | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4101] | |
ParameterName=Select System FIFO item to read in 4102h | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD OBJECT=SYSTEM_FIFO_IN | |
;SEVCONFIELD SECTION=SystemLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4102] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=System FIFO Output | |
;SEVCONFIELD OBJECT=SYSTEM_FIFO_OUT | |
;SEVCONFIELD SECTION=SystemLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4102sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4102sub1] | |
ParameterName=Event ID | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4102sub2] | |
ParameterName=Hours | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4102sub3] | |
ParameterName=Minutes / Seconds | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4102sub4] | |
ParameterName=Data Byte 1 | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4102sub5] | |
ParameterName=Data Byte 2 | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4102sub6] | |
ParameterName=Data Byte 3 | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4110] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Faults FIFO Control | |
;SEVCONFIELD OBJECT=FAULTS_FIFO_CTRL | |
;SEVCONFIELD SECTION=FaultLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4110sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4110sub1] | |
ParameterName=Reset (write to reset faults FIFO) | |
ObjectType=7 | |
DataType=1 | |
AccessType=wo | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Reset | |
;SEVCONFIELD 1=Reset | |
;SEVCONFIELD COMMS_TIMEOUT=20000 | |
[4110sub2] | |
ParameterName=Number of items in Faults FIFO | |
ParameterValue=0x0028 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4111] | |
ParameterName=Select Faults FIFO item to read in 4102h | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD OBJECT=FAULTS_FIFO_IN | |
;SEVCONFIELD SECTION=FaultLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4112] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Faults FIFO Output | |
;SEVCONFIELD OBJECT=FAULTS_FIFO_OUT | |
;SEVCONFIELD SECTION=FaultLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4112sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4112sub1] | |
ParameterName=Event ID | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4112sub2] | |
ParameterName=Hours | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4112sub3] | |
ParameterName=Minutes / Seconds | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4112sub4] | |
ParameterName=Data Byte 1 | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4112sub5] | |
ParameterName=Data Byte 2 | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4112sub6] | |
ParameterName=Data Byte 3 | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4200] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=Other Event Log Control | |
;SEVCONFIELD OBJECT=OTHER_EventLog_CTRL | |
;SEVCONFIELD SECTION=EventLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4200sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4200sub1] | |
ParameterName=Reset (write to reset event counters) | |
ObjectType=7 | |
DataType=1 | |
AccessType=wo | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Reset | |
;SEVCONFIELD 1=Reset | |
;SEVCONFIELD COMMS_TIMEOUT=20000 | |
[4201] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Other Event Counter 1 | |
;SEVCONFIELD OBJECT=EVENT_COUNTER | |
;SEVCONFIELD SECTION=EventLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4201sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4201sub1] | |
ParameterName=Event ID | |
ParameterValue=0x4f4c | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=logging.ev_ctrs[0].mask | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4201sub2] | |
ParameterName=First Event Hours | |
ParameterValue=0x001a | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4201sub3] | |
ParameterName=First Event Minutes / Seconds | |
ParameterValue=0x67 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4201sub4] | |
ParameterName=Last Event Hours | |
ParameterValue=0x002d | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4201sub5] | |
ParameterName=Last Event Minutes / Seconds | |
ParameterValue=0x8c | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4201sub6] | |
ParameterName=Counter | |
ParameterValue=0x0013 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
[4202] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Other Event Counter 2 | |
;SEVCONFIELD OBJECT=EVENT_COUNTER | |
;SEVCONFIELD SECTION=EventLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4202sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4202sub1] | |
ParameterName=Event ID | |
ParameterValue=0x5101 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=logging.ev_ctrs[1].mask | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4202sub2] | |
ParameterName=First Event Hours | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4202sub3] | |
ParameterName=First Event Minutes / Seconds | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4202sub4] | |
ParameterName=Last Event Hours | |
ParameterValue=0x0013 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4202sub5] | |
ParameterName=Last Event Minutes / Seconds | |
ParameterValue=0x9e | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4202sub6] | |
ParameterName=Counter | |
ParameterValue=0x0033 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
[4203] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Other Event Counter 3 | |
;SEVCONFIELD OBJECT=EVENT_COUNTER | |
;SEVCONFIELD SECTION=EventLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4203sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4203sub1] | |
ParameterName=Event ID | |
ParameterValue=0x51c2 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=logging.ev_ctrs[2].mask | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4203sub2] | |
ParameterName=First Event Hours | |
ParameterValue=0x0016 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4203sub3] | |
ParameterName=First Event Minutes / Seconds | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4203sub4] | |
ParameterName=Last Event Hours | |
ParameterValue=0x0016 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4203sub5] | |
ParameterName=Last Event Minutes / Seconds | |
ParameterValue=0x15 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4203sub6] | |
ParameterName=Counter | |
ParameterValue=0x0002 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
[4204] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Other Event Counter 4 | |
;SEVCONFIELD OBJECT=EVENT_COUNTER | |
;SEVCONFIELD SECTION=EventLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4204sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4204sub1] | |
ParameterName=Event ID | |
ParameterValue=0x4f41 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=logging.ev_ctrs[3].mask | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4204sub2] | |
ParameterName=First Event Hours | |
ParameterValue=0x001e | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4204sub3] | |
ParameterName=First Event Minutes / Seconds | |
ParameterValue=0x38 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4204sub4] | |
ParameterName=Last Event Hours | |
ParameterValue=0x002f | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4204sub5] | |
ParameterName=Last Event Minutes / Seconds | |
ParameterValue=0xec | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4204sub6] | |
ParameterName=Counter | |
ParameterValue=0x0009 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
[4205] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Other Event Counter 5 | |
;SEVCONFIELD OBJECT=EVENT_COUNTER | |
;SEVCONFIELD SECTION=EventLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4205sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4205sub1] | |
ParameterName=Event ID | |
ParameterValue=0x52c4 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=logging.ev_ctrs[4].mask | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4205sub2] | |
ParameterName=First Event Hours | |
ParameterValue=0x0007 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4205sub3] | |
ParameterName=First Event Minutes / Seconds | |
ParameterValue=0x18 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4205sub4] | |
ParameterName=Last Event Hours | |
ParameterValue=0x0007 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4205sub5] | |
ParameterName=Last Event Minutes / Seconds | |
ParameterValue=0x19 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4205sub6] | |
ParameterName=Counter | |
ParameterValue=0x0002 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
[4206] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Other Event Counter 6 | |
;SEVCONFIELD OBJECT=EVENT_COUNTER | |
;SEVCONFIELD SECTION=EventLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4206sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4206sub1] | |
ParameterName=Event ID | |
ParameterValue=0x5044 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=logging.ev_ctrs[5].mask | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4206sub2] | |
ParameterName=First Event Hours | |
ParameterValue=0x0001 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4206sub3] | |
ParameterName=First Event Minutes / Seconds | |
ParameterValue=0xa9 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4206sub4] | |
ParameterName=Last Event Hours | |
ParameterValue=0x0030 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4206sub5] | |
ParameterName=Last Event Minutes / Seconds | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4206sub6] | |
ParameterName=Counter | |
ParameterValue=0x0041 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
[4207] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Other Event Counter 7 | |
;SEVCONFIELD OBJECT=EVENT_COUNTER | |
;SEVCONFIELD SECTION=EventLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4207sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4207sub1] | |
ParameterName=Event ID | |
ParameterValue=0x54c1 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=logging.ev_ctrs[6].mask | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4207sub2] | |
ParameterName=First Event Hours | |
ParameterValue=0x0018 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4207sub3] | |
ParameterName=First Event Minutes / Seconds | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4207sub4] | |
ParameterName=Last Event Hours | |
ParameterValue=0x001a | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4207sub5] | |
ParameterName=Last Event Minutes / Seconds | |
ParameterValue=0xc7 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4207sub6] | |
ParameterName=Counter | |
ParameterValue=0x0002 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
[4208] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Other Event Counter 8 | |
;SEVCONFIELD OBJECT=EVENT_COUNTER | |
;SEVCONFIELD SECTION=EventLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4208sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4208sub1] | |
ParameterName=Event ID | |
ParameterValue=0x3441 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=logging.ev_ctrs[7].mask | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4208sub2] | |
ParameterName=First Event Hours | |
ParameterValue=0x0007 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4208sub3] | |
ParameterName=First Event Minutes / Seconds | |
ParameterValue=0x18 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4208sub4] | |
ParameterName=Last Event Hours | |
ParameterValue=0x001a | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4208sub5] | |
ParameterName=Last Event Minutes / Seconds | |
ParameterValue=0x61 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4208sub6] | |
ParameterName=Counter | |
ParameterValue=0x000a | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
[4209] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Other Event Counter 9 | |
;SEVCONFIELD OBJECT=EVENT_COUNTER | |
;SEVCONFIELD SECTION=EventLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4209sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4209sub1] | |
ParameterName=Event ID | |
ParameterValue=0x4f55 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=logging.ev_ctrs[8].mask | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[4209sub2] | |
ParameterName=First Event Hours | |
ParameterValue=0x0020 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4209sub3] | |
ParameterName=First Event Minutes / Seconds | |
ParameterValue=0x61 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4209sub4] | |
ParameterName=Last Event Hours | |
ParameterValue=0x0020 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[4209sub5] | |
ParameterName=Last Event Minutes / Seconds | |
ParameterValue=0x61 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4209sub6] | |
ParameterName=Counter | |
ParameterValue=0x0001 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
[420A] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Other Event Counter 10 | |
;SEVCONFIELD OBJECT=EVENT_COUNTER | |
;SEVCONFIELD SECTION=EventLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[420Asub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[420Asub1] | |
ParameterName=Event ID | |
ParameterValue=0x5043 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD EEPROM=logging.ev_ctrs[9].mask | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[420Asub2] | |
ParameterName=First Event Hours | |
ParameterValue=0x0007 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[420Asub3] | |
ParameterName=First Event Minutes / Seconds | |
ParameterValue=0x18 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[420Asub4] | |
ParameterName=Last Event Hours | |
ParameterValue=0x0030 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD UNITS=Hours | |
[420Asub5] | |
ParameterName=Last Event Minutes / Seconds | |
ParameterValue=0x24 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[420Asub6] | |
ParameterName=Counter | |
ParameterValue=0x001f | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
[4300] | |
SubNumber=14 | |
ObjectType=9 | |
ParameterName=Operational Monitor - Customer Copy | |
;SEVCONFIELD OBJECT=CUST_OPERATIONAL_MONITOR | |
;SEVCONFIELD SECTION=OperationalLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4300sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x0d | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=13 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4300sub1] | |
ParameterName=Reset | |
ObjectType=7 | |
DataType=1 | |
AccessType=wo | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Reset | |
;SEVCONFIELD 1=Reset | |
[4300sub2] | |
ParameterName=Minimum Battery Voltage | |
ParameterValue=0x0278 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
[4300sub3] | |
ParameterName=Maximum Battery Voltage | |
ParameterValue=0x0668 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
[4300sub4] | |
ParameterName=Minimum Capacitor Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
[4300sub5] | |
ParameterName=Maximum Capacitor Voltage | |
ParameterValue=0x0658 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
[4300sub6] | |
ParameterName=Minimum Motor Current 1 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=A(RMS) | |
[4300sub7] | |
ParameterName=Maximum Motor Current 1 | |
ParameterValue=0x02c8 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=A(RMS) | |
[4300sub8] | |
ParameterName=Minimum Motor Current 2 | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=A(RMS) | |
[4300sub9] | |
ParameterName=Maximum Motor Current 2 | |
ParameterValue=0x8000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=A(RMS) | |
[4300subA] | |
ParameterName=Minimum Motor Speed | |
ParameterValue=0xf6ea | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=RPM | |
[4300subB] | |
ParameterName=Maximum Motor Speed | |
ParameterValue=0x116e | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=RPM | |
[4300subC] | |
ParameterName=Minimum Device Temperature | |
ParameterValue=0x0012 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=DegC | |
[4300subD] | |
ParameterName=Maximum Device Temperature | |
ParameterValue=0x0041 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=DegC | |
[4301] | |
SubNumber=14 | |
ObjectType=9 | |
ParameterName=Operational Monitor - Sevcon Copy | |
;SEVCONFIELD OBJECT=SEVCON_OPERATIONAL_MONITOR | |
;SEVCONFIELD SECTION=OperationalLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4301sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x0d | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=13 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4301sub1] | |
ParameterName=Reset | |
ObjectType=7 | |
DataType=1 | |
AccessType=wo | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=5 | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Reset | |
;SEVCONFIELD 1=Reset | |
[4301sub2] | |
ParameterName=Minimum Battery Voltage | |
ParameterValue=0x0288 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
[4301sub3] | |
ParameterName=Maximum Battery Voltage | |
ParameterValue=0x0650 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
[4301sub4] | |
ParameterName=Minimum Capacitor Voltage | |
ParameterValue=0x0076 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
[4301sub5] | |
ParameterName=Maximum Capacitor Voltage | |
ParameterValue=0x065f | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
[4301sub6] | |
ParameterName=Minimum Motor Current 1 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=A(RMS) | |
[4301sub7] | |
ParameterName=Maximum Motor Current 1 | |
ParameterValue=0x0240 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=A(RMS) | |
[4301sub8] | |
ParameterName=Minimum Motor Current 2 | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=A(RMS) | |
[4301sub9] | |
ParameterName=Maximum Motor Current 2 | |
ParameterValue=0x8000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=A(RMS) | |
[4301subA] | |
ParameterName=Minimum Motor Speed | |
ParameterValue=0xf6ea | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=RPM | |
[4301subB] | |
ParameterName=Maximum Motor Speed | |
ParameterValue=0x116e | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=RPM | |
[4301subC] | |
ParameterName=Minimum Device Temperature | |
ParameterValue=0x0012 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=DegC | |
[4301subD] | |
ParameterName=Maximum Device Temperature | |
ParameterValue=0x0040 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=DegC | |
[4600] | |
SubNumber=16 | |
ObjectType=9 | |
ParameterName=Additional Motor Measurements | |
;SEVCONFIELD OBJECT=ADD_MOTOR_STATUS | |
;SEVCONFIELD SECTION=Motor1Status | |
;SEVCONFIELD CATEGORY=MONITORING | |
[4600sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x10 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=18 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4600sub1] | |
ParameterName=Slip Frequency | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=2.45436926061703E-02 | |
;SEVCONFIELD UNITS=rads/s | |
[4600sub3] | |
ParameterName=Temperature (Measured - PTC) | |
ParameterValue=0x0015 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-50 | |
HighLimit=250 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=DegC | |
[4600sub4] | |
ParameterName=Temperature (Measured - Switch) | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Motor OK | |
;SEVCONFIELD 1=Motor Too Hot | |
[4600sub5] | |
ParameterName=Target Id (If) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32000 | |
HighLimit=32000 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A | |
[4600sub6] | |
ParameterName=Target Iq (Ia) | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32000 | |
HighLimit=32000 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A | |
[4600sub7] | |
ParameterName=Id (If) | |
ParameterValue=0xfff9 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A | |
[4600sub8] | |
ParameterName=Iq (Ia) | |
ParameterValue=0x0001 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A | |
[4600sub9] | |
ParameterName=Ud (Uf) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-3200 | |
HighLimit=3200 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
[4600subA] | |
ParameterName=Uq (Ua) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-3200 | |
HighLimit=3200 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
[4600subB] | |
ParameterName=Voltage modulation | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=255 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.392156862745098 | |
;SEVCONFIELD UNITS=% | |
[4600subC] | |
ParameterName=Actual AC Motor Current | |
ParameterValue=0x0001 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=A | |
[4600subD] | |
ParameterName=Actual AC Motor Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
[4600subE] | |
ParameterName=Motor velocity for 2nd motor | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=4 | |
AccessType=ro | |
LowLimit=-20000 | |
HighLimit=20000 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=RPM | |
[4600subF] | |
ParameterName=Electrical output frequency | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-2048 | |
HighLimit=2047 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=rads/s | |
[4600sub10] | |
ParameterName=Temperature (Measured - Remote) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-50 | |
HighLimit=250 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=DegC | |
[4601] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Pulsing Hours Counter | |
;SEVCONFIELD OBJECT=PULSING_HOURS | |
;SEVCONFIELD SECTION=HoursCounters | |
;SEVCONFIELD CATEGORY=LOGGING | |
[4601sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4601sub1] | |
ParameterName=Hours | |
ParameterValue=0x0001 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=Hours | |
[4601sub2] | |
ParameterName=Minutes / Seconds | |
ParameterValue=0xc8 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[4602] | |
SubNumber=25 | |
ObjectType=9 | |
ParameterName=AC Motor Debug Information | |
;SEVCONFIELD OBJECT=MOTOR_DEBUG | |
;SEVCONFIELD SECTION=Motor1Debug | |
;SEVCONFIELD CATEGORY=MONITORING | |
[4602sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x23 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=45 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4602sub1] | |
ParameterName=Motor Temperature/Torque Cutback (DWork.Tj_cutback_factor) | |
ParameterValue=0x0100 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
[4602sub2] | |
ParameterName=Junction Temperature 1 (DWork.Tj[0]) | |
ParameterValue=0x0016 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=DegC | |
[4602sub3] | |
ParameterName=Junction Temperature 2 (DWork.Tj[1]) | |
ParameterValue=0x0016 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=DegC | |
[4602sub4] | |
ParameterName=Junction Temperature 3 (DWork.Tj[2]) | |
ParameterValue=0x0016 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=DegC | |
[4602sub5] | |
ParameterName=Junction Temperature 4 (DWork.Tj[3]) | |
ParameterValue=0x0016 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=DegC | |
[4602sub6] | |
ParameterName=Junction Temperature 5 (DWork.Tj[4]) | |
ParameterValue=0x0016 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=DegC | |
[4602sub7] | |
ParameterName=Junction Temperature 6 (DWork.Tj[5]) | |
ParameterValue=0x0016 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=DegC | |
[4602sub8] | |
ParameterName=Motor Temperature Estimate (DWork.T_motor) | |
ParameterValue=0x0016 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=DegC | |
[4602sub9] | |
ParameterName=Heatsink Temperature (U.DSP_Ts) | |
ParameterValue=0x16 | |
ObjectType=7 | |
DataType=2 | |
AccessType=ro | |
LowLimit=-128 | |
HighLimit=127 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=DegC | |
[4602subA] | |
ParameterName=Overall DSP Maximum Motor Temperature (Y.Temp_max) | |
ParameterValue=0x004d | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=DegC | |
[4602subB] | |
ParameterName=Torque demand value (U.T_d) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=Nm | |
[4602subC] | |
ParameterName=Torque actual value (DWork.Td) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=Nm | |
[4602subD] | |
ParameterName=Maximum torque (DWork.Td_max) | |
ParameterValue=0x055e | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=Nm | |
[4602subE] | |
ParameterName=Maximum power limit torque (Y.T_power_limit) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=Nm | |
[4602subF] | |
ParameterName=Trip Voltage (DWork.Vtrip) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
[4602sub10] | |
ParameterName=Drive torque voltage cutback factor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.000030517578125 | |
[4602sub11] | |
ParameterName=Battery Voltage | |
ParameterValue=0x0551 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
[4602sub12] | |
ParameterName=Capacitor Voltage | |
ParameterValue=0x00ac | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
[4602sub13] | |
ParameterName=Capacitor short term temperature estimate | |
ParameterValue=0x0015 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=DegC | |
[4602sub14] | |
ParameterName=PCB Track Temperature Estimate | |
ParameterValue=0x0016 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=DegC | |
[4602sub15] | |
ParameterName=Capacitor long term temperature estimate | |
ParameterValue=0x0015 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=DegC | |
[4602sub16] | |
ParameterName=Current sensor autozero value (M1) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A | |
[4602sub17] | |
ParameterName=Current sensor autozero value (M2) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A | |
[4602sub23] | |
ParameterName=Encoder debug flags | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
[4603] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=Additional Motor 2 Measurements | |
;SEVCONFIELD OBJECT=ADD_MOTOR_STATUS | |
;SEVCONFIELD SECTION=Motor1Status | |
;SEVCONFIELD CATEGORY=MONITORING | |
[4603sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4603sub1] | |
ParameterName=Temperature (Measured - PTC) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=-50 | |
HighLimit=250 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=DegC | |
[4610] | |
SubNumber=19 | |
ObjectType=9 | |
ParameterName=Id factor map | |
;SEVCONFIELD OBJECT=MOTOR_FLUX_MAP | |
;SEVCONFIELD SECTION=MOTOR1CHARACTERIZATION | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4610sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x12 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=18 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
[4610sub1] | |
ParameterName=Pt 1 Slip | |
ParameterValue=0xfff0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=65520 | |
HighLimit=65520 | |
PDOMapping=0 | |
DefaultValue=0x0000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=p.u. slip | |
;SEVCONFIELD EEPROM=motor_0.flux_map[0].x | |
[4610sub2] | |
ParameterName=Pt 1 Id factor | |
ParameterValue=0x0040 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue= | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.015625 | |
;SEVCONFIELD UNITS=p.u. Id | |
;SEVCONFIELD EEPROM=motor_0.flux_map[0].y | |
[4610sub3] | |
ParameterName=Pt 2 Slip | |
ParameterValue=0xffc0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0x0002 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=p.u. slip | |
;SEVCONFIELD EEPROM=motor_0.flux_map[1].x | |
[4610sub4] | |
ParameterName=Pt 2 Id factor | |
ParameterValue=0x0030 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue= | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.015625 | |
;SEVCONFIELD UNITS=p.u. Id | |
;SEVCONFIELD EEPROM=motor_0.flux_map[1].y | |
[4610sub5] | |
ParameterName=Pt 3 Slip | |
ParameterValue=0xffd0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0x0004 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=p.u. slip | |
;SEVCONFIELD EEPROM=motor_0.flux_map[2].x | |
[4610sub6] | |
ParameterName=Pt 3 Id factor | |
ParameterValue=0x0020 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue= | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.015625 | |
;SEVCONFIELD UNITS=p.u. Id | |
;SEVCONFIELD EEPROM=motor_0.flux_map[2].y | |
[4610sub7] | |
ParameterName=Pt 4 Slip | |
ParameterValue=0xffe8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0x0006 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=p.u. slip | |
;SEVCONFIELD EEPROM=motor_0.flux_map[3].x | |
[4610sub8] | |
ParameterName=Pt 4 Id factor | |
ParameterValue=0x0010 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue= | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.015625 | |
;SEVCONFIELD UNITS=p.u. Id | |
;SEVCONFIELD EEPROM=motor_0.flux_map[3].y | |
[4610sub9] | |
ParameterName=Pt 5 Slip | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0x0008 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=p.u. slip | |
;SEVCONFIELD EEPROM=motor_0.flux_map[4].x | |
[4610subA] | |
ParameterName=Pt 5 Id factor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue= | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.015625 | |
;SEVCONFIELD UNITS=p.u. Id | |
;SEVCONFIELD EEPROM=motor_0.flux_map[4].y | |
[4610subB] | |
ParameterName=Pt 6 Slip | |
ParameterValue=0x0018 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0x000a | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=p.u. slip | |
;SEVCONFIELD EEPROM=motor_0.flux_map[5].x | |
[4610subC] | |
ParameterName=Pt 6 Id factor | |
ParameterValue=0x0010 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue= | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.015625 | |
;SEVCONFIELD UNITS=p.u. Id | |
;SEVCONFIELD EEPROM=motor_0.flux_map[5].y | |
[4610subD] | |
ParameterName=Pt 7 Slip | |
ParameterValue=0x0030 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0x000c | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=p.u. slip | |
;SEVCONFIELD EEPROM=motor_0.flux_map[6].x | |
[4610subE] | |
ParameterName=Pt 7 Id factor | |
ParameterValue=0x0020 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue= | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.015625 | |
;SEVCONFIELD UNITS=p.u. Id | |
;SEVCONFIELD EEPROM=motor_0.flux_map[6].y | |
[4610subF] | |
ParameterName=Pt 8 Slip | |
ParameterValue=0x0040 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0x000e | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=p.u. slip | |
;SEVCONFIELD EEPROM=motor_0.flux_map[7].x | |
[4610sub10] | |
ParameterName=Pt 8 Id factor | |
ParameterValue=0x0030 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue= | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.015625 | |
;SEVCONFIELD UNITS=p.u. Id | |
;SEVCONFIELD EEPROM=motor_0.flux_map[7].y | |
[4610sub11] | |
ParameterName=Pt 9 Slip | |
ParameterValue=0x0010 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=16 | |
HighLimit=16 | |
PDOMapping=0 | |
DefaultValue=0x0010 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=p.u. slip | |
;SEVCONFIELD EEPROM=motor_0.flux_map[8].x | |
[4610sub12] | |
ParameterName=Pt 9 Id factor | |
ParameterValue=0x0040 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue= | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.015625 | |
;SEVCONFIELD UNITS=p.u. Id | |
;SEVCONFIELD EEPROM=motor_0.flux_map[8].y | |
[4611] | |
SubNumber=19 | |
ObjectType=9 | |
ParameterName=Motor max slip map | |
;SEVCONFIELD OBJECT=MOTOR_POWER_LIMIT_MAP | |
;SEVCONFIELD SECTION=MOTOR1CHARACTERIZATION | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4611sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x12 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=18 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
[4611sub1] | |
ParameterName=Pt 1 Max Slip | |
ParameterValue=0x0780 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=160 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=rad/s | |
;SEVCONFIELD EEPROM=motor_0.power_map[0].x | |
[4611sub2] | |
ParameterName=Pt 1 Speed | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=motor_0.power_map[0].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4611sub3] | |
ParameterName=Pt 2 Max Slip | |
ParameterValue=0x0780 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=160 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=rad/s | |
;SEVCONFIELD EEPROM=motor_0.power_map[1].x | |
[4611sub4] | |
ParameterName=Pt 2 Speed | |
ParameterValue=0x01f4 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=motor_0.power_map[1].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4611sub5] | |
ParameterName=Pt 3 Max Slip | |
ParameterValue=0x0780 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=320 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=rad/s | |
;SEVCONFIELD EEPROM=motor_0.power_map[2].x | |
[4611sub6] | |
ParameterName=Pt 3 Speed | |
ParameterValue=0x03e8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=2000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=motor_0.power_map[2].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4611sub7] | |
ParameterName=Pt 4 Max Slip | |
ParameterValue=0x0780 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=480 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=rad/s | |
;SEVCONFIELD EEPROM=motor_0.power_map[3].x | |
[4611sub8] | |
ParameterName=Pt 4 Speed | |
ParameterValue=0x07d0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=3000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=motor_0.power_map[3].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4611sub9] | |
ParameterName=Pt 5 Max Slip | |
ParameterValue=0x0780 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=480 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=rad/s | |
;SEVCONFIELD EEPROM=motor_0.power_map[4].x | |
[4611subA] | |
ParameterName=Pt 5 Speed | |
ParameterValue=0x0bb8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=4000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=motor_0.power_map[4].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4611subB] | |
ParameterName=Pt 6 Max Slip | |
ParameterValue=0x0780 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=480 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=rad/s | |
;SEVCONFIELD EEPROM=motor_0.power_map[5].x | |
[4611subC] | |
ParameterName=Pt 6 Speed | |
ParameterValue=0x0fa0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=5000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=motor_0.power_map[5].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4611subD] | |
ParameterName=Pt 7 Max Slip | |
ParameterValue=0x0780 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=480 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=rad/s | |
;SEVCONFIELD EEPROM=motor_0.power_map[6].x | |
[4611subE] | |
ParameterName=Pt 7 Speed | |
ParameterValue=0x1388 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=6000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=motor_0.power_map[6].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4611subF] | |
ParameterName=Pt 8 Max Slip | |
ParameterValue=0x0780 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=480 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=rad/s | |
;SEVCONFIELD EEPROM=motor_0.power_map[7].x | |
[4611sub10] | |
ParameterName=Pt 8 Speed | |
ParameterValue=0x1770 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=7000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=motor_0.power_map[7].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4611sub11] | |
ParameterName=Pt 9 Max Slip | |
ParameterValue=0x0780 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=480 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=rad/s | |
;SEVCONFIELD EEPROM=motor_0.power_map[8].x | |
[4611sub12] | |
ParameterName=Pt 9 Speed | |
ParameterValue=0x1b58 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=8000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=RPM | |
;SEVCONFIELD EEPROM=motor_0.power_map[8].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4612] | |
SubNumber=19 | |
ObjectType=9 | |
ParameterName=Voltage Torque-Cutback Map | |
;SEVCONFIELD OBJECT=VOLTAGE_TRQ_CUTBACK_MAP | |
;SEVCONFIELD SECTION=MOTOR1CHARACTERIZATION | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4612sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x12 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=18 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4612sub1] | |
ParameterName=Pt 1 Voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[0].x | |
[4612sub2] | |
ParameterName=Pt 1 Voltage Cutback Gain | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0000305175781 | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[0].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4612sub3] | |
ParameterName=Pt 2 Voltage | |
ParameterValue=0x0240 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=1382 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[1].x | |
[4612sub4] | |
ParameterName=Pt 2 Voltage Cutback Gain | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0000305175781 | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[1].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4612sub5] | |
ParameterName=Pt 3 Voltage | |
ParameterValue=0x0280 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=2304 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[2].x | |
[4612sub6] | |
ParameterName=Pt 3 Voltage Cutback Gain | |
ParameterValue=0x7ffc | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0000305175781 | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[2].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4612sub7] | |
ParameterName=Pt 4 Voltage | |
ParameterValue=0x0640 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=3840 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[3].x | |
[4612sub8] | |
ParameterName=Pt 4 Voltage Cutback Gain | |
ParameterValue=0x7ffc | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=32767 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0000305175781 | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[3].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4612sub9] | |
ParameterName=Pt 5 Voltage | |
ParameterValue=0x0740 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=4454 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[4].x | |
[4612subA] | |
ParameterName=Pt 5 Voltage Cutback Gain | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0000305175781 | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[4].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4612subB] | |
ParameterName=Pt 6 Voltage | |
ParameterValue=0x0740 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=4454 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[5].x | |
[4612subC] | |
ParameterName=Pt 6 Voltage Cutback Gain | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0000305175781 | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[5].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4612subD] | |
ParameterName=Pt 7 Voltage | |
ParameterValue=0x0740 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=4454 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[6].x | |
[4612subE] | |
ParameterName=Pt 7 Voltage Cutback Gain | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0000305175781 | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[6].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4612subF] | |
ParameterName=Pt 8 Voltage | |
ParameterValue=0x0740 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=4454 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[7].x | |
[4612sub10] | |
ParameterName=Pt 8 Voltage Cutback Gain | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0000305175781 | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[7].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4612sub11] | |
ParameterName=Pt 9 Voltage | |
ParameterValue=0x0740 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=4454 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[8].x | |
[4612sub12] | |
ParameterName=Pt 9 Voltage Cutback Gain | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7FFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0000305175781 | |
;SEVCONFIELD EEPROM=motor_0.torque_cutback[8].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4614] | |
SubNumber=19 | |
ObjectType=9 | |
ParameterName=Im/Lm Saturation Map | |
;SEVCONFIELD OBJECT=IMLM_SATURATION_MAP | |
;SEVCONFIELD SECTION=MOTOR1CHARACTERIZATION | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4614sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x12 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=18 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4614sub1] | |
ParameterName=Pt 1 Mag Current | |
ParameterValue=0x0149 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A(RMS) | |
;SEVCONFIELD EEPROM=misc.saturation_map[0].x | |
[4614sub2] | |
ParameterName=Pt 1 Mag Inductance | |
ParameterValue=0x11c3 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=4587 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000244141 | |
;SEVCONFIELD UNITS=puH | |
;SEVCONFIELD EEPROM=misc.saturation_map[0].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4614sub3] | |
ParameterName=Pt 2 Mag Current | |
ParameterValue=0x0226 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=500 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A(RMS) | |
;SEVCONFIELD EEPROM=misc.saturation_map[1].x | |
[4614sub4] | |
ParameterName=Pt 2 Mag Inductance | |
ParameterValue=0x1152 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=4301 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000244141 | |
;SEVCONFIELD UNITS=puH | |
;SEVCONFIELD EEPROM=misc.saturation_map[1].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4614sub5] | |
ParameterName=Pt 3 Mag Current | |
ParameterValue=0x0303 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A(RMS) | |
;SEVCONFIELD EEPROM=misc.saturation_map[2].x | |
[4614sub6] | |
ParameterName=Pt 3 Mag Inductance | |
ParameterValue=0x0fa2 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=3840 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000244141 | |
;SEVCONFIELD UNITS=puH | |
;SEVCONFIELD EEPROM=misc.saturation_map[2].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4614sub7] | |
ParameterName=Pt 4 Mag Current | |
ParameterValue=0x03e0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=1499 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A(RMS) | |
;SEVCONFIELD EEPROM=misc.saturation_map[3].x | |
[4614sub8] | |
ParameterName=Pt 4 Mag Inductance | |
ParameterValue=0x0d9f | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=3194 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000244141 | |
;SEVCONFIELD UNITS=puH | |
;SEVCONFIELD EEPROM=misc.saturation_map[3].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4614sub9] | |
ParameterName=Pt 5 Mag Current | |
ParameterValue=0x04be | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=1600 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A(RMS) | |
;SEVCONFIELD EEPROM=misc.saturation_map[4].x | |
[4614subA] | |
ParameterName=Pt 5 Mag Inductance | |
ParameterValue=0x0bec | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=3030 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000244141 | |
;SEVCONFIELD UNITS=puH | |
;SEVCONFIELD EEPROM=misc.saturation_map[4].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4614subB] | |
ParameterName=Pt 6 Mag Current | |
ParameterValue=0x059b | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=2100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A(RMS) | |
;SEVCONFIELD EEPROM=misc.saturation_map[5].x | |
[4614subC] | |
ParameterName=Pt 6 Mag Inductance | |
ParameterValue=0x0a91 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=2539 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000244141 | |
;SEVCONFIELD UNITS=puH | |
;SEVCONFIELD EEPROM=misc.saturation_map[5].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4614subD] | |
ParameterName=Pt 7 Mag Current | |
ParameterValue=0x0678 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=2400 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A(RMS) | |
;SEVCONFIELD EEPROM=misc.saturation_map[6].x | |
[4614subE] | |
ParameterName=Pt 7 Mag Inductance | |
ParameterValue=0x097c | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=2334 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000244141 | |
;SEVCONFIELD UNITS=puH | |
;SEVCONFIELD EEPROM=misc.saturation_map[6].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4614subF] | |
ParameterName=Pt 8 Mag Current | |
ParameterValue=0x0755 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=3200 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A(RMS) | |
;SEVCONFIELD EEPROM=misc.saturation_map[7].x | |
[4614sub10] | |
ParameterName=Pt 8 Mag Inductance | |
ParameterValue=0x089b | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=1884 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000244141 | |
;SEVCONFIELD UNITS=puH | |
;SEVCONFIELD EEPROM=misc.saturation_map[7].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4614sub11] | |
ParameterName=Pt 9 Mag Current | |
ParameterValue=0x0832 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=4000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A(RMS) | |
;SEVCONFIELD EEPROM=misc.saturation_map[8].x | |
[4614sub12] | |
ParameterName=Pt 9 Mag Inductance | |
ParameterValue=0x07e3 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=1556 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000244141 | |
;SEVCONFIELD UNITS=puH | |
;SEVCONFIELD EEPROM=misc.saturation_map[8].y | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4620] | |
SubNumber=8 | |
ObjectType=9 | |
ParameterName=Motor Temperature Sensor | |
;SEVCONFIELD OBJECT=ALG_IN_MOTOR_TEMP | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4620sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x07 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=8 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4620sub1] | |
ParameterName=Mode | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=3 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=motor_0.temp_meas_mode | |
;SEVCONFIELD NUMBER_FORMAT=5 | |
;SEVCONFIELD 0=None | |
;SEVCONFIELD 1=PTC | |
;SEVCONFIELD 2=Switch | |
;SEVCONFIELD 3=PTC and Switch | |
;SEVCONFIELD 4=Remote | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4620sub2] | |
ParameterName=High Temperature Voltage (PTC) | |
ParameterValue=0x11c0 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=motor_0.temp_meas_high_temp_voltage | |
[4620sub3] | |
ParameterName=Low Temperature Voltage (PTC) | |
ParameterValue=0x0b00 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=motor_0.temp_meas_low_temp_voltage | |
[4620sub4] | |
ParameterName=Switch source | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=motor_0.temp_meas_switch_source | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4620sub5] | |
ParameterName=PTC type | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=2 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD NUMBER_FORMAT=3 | |
;SEVCONFIELD 0=User Defined | |
;SEVCONFIELD 1=KTY84 | |
;SEVCONFIELD 2=KTY83 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4620sub6] | |
ParameterName=Failure torque cutback rate | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=19200 | |
PDOMapping=0 | |
DefaultValue=1920 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=s | |
[4620sub7] | |
ParameterName=Failure torque recovery rate | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=19200 | |
PDOMapping=0 | |
DefaultValue=80 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=s | |
[4621] | |
SubNumber=8 | |
ObjectType=9 | |
ParameterName=Motor Temperature Setup | |
;SEVCONFIELD OBJECT=MOTOR_TEMP_LIMIT | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4621sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x07 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=7 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4621sub1] | |
ParameterName=Motor temperature estimate current constant | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0x0078 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.5 | |
;SEVCONFIELD EEPROM=motor_0.temp_meas_i_const | |
[4621sub2] | |
ParameterName=Motor temperature estimate discretization | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0x7F4B | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=motor_0.temp_meas_discretisation | |
[4621sub3] | |
ParameterName=Maximum allowable motor temperature | |
ParameterValue=0x0078 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32768 | |
PDOMapping=0 | |
DefaultValue=0x005A | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=DegC | |
;SEVCONFIELD EEPROM=motor_0.temp_meas_maximum | |
[4621sub4] | |
ParameterName=Rotor resistance variation hot temperature | |
ParameterValue=0x0064 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32768 | |
PDOMapping=0 | |
DefaultValue=140 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=DegC | |
[4621sub5] | |
ParameterName=Rotor resistance variation cold temperature | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=-32768 | |
HighLimit=32768 | |
PDOMapping=0 | |
DefaultValue=-40 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=DegC | |
[4621sub6] | |
ParameterName=Rotor resistance variation hot factor | |
ParameterValue=0x0100 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=64 | |
HighLimit=1024 | |
PDOMapping=0 | |
DefaultValue=0x0100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
[4621sub7] | |
ParameterName=Rotor resistance variation cold factor | |
ParameterValue=0x0100 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=64 | |
HighLimit=1024 | |
PDOMapping=0 | |
DefaultValue=0x0100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
[4623] | |
SubNumber=5 | |
ObjectType=9 | |
ParameterName=Battery current limit | |
;SEVCONFIELD OBJECT=MOTOR_IBATT_CUTBACK | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4623sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x04 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=4 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
[4623sub1] | |
ParameterName=Maximum battery charge current | |
ParameterValue=0xff9c | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=-32768 | |
HighLimit=0 | |
PDOMapping=1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=A | |
[4623sub2] | |
ParameterName=Maximum battery discharge current | |
ParameterValue=0x0078 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rww | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=A | |
[4623sub3] | |
ParameterName=Cutback range | |
ParameterValue=0x0014 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x7fff | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=A | |
[4623sub4] | |
ParameterName=Battery current estimation correction factor | |
ParameterValue=0x1000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=rw | |
LowLimit=2048 | |
HighLimit=6144 | |
PDOMapping=0 | |
DefaultValue=0x1000 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000244140625 | |
[4624] | |
ParameterName=Motor overspeed protection | |
ParameterValue=0x1b58 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=1000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=rpm | |
;SEVCONFIELD OBJECT=MOTOR_OVERSPEED_PROTECTION | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4630] | |
SubNumber=5 | |
ObjectType=9 | |
ParameterName=Encoder Configuration | |
;SEVCONFIELD OBJECT=ENCODER_PULLUP | |
;SEVCONFIELD SECTION=EncoderConfig | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4630sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x04 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=19 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4630sub1] | |
ParameterName=Encoder Pull Up | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=motor_0.encoder_pullup | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4630sub2] | |
ParameterName=Encoder Supply | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=motor_0.encoder_supply | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=10V | |
;SEVCONFIELD 1=5V | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4630sub3] | |
ParameterName=Encoder Type | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD NUMBER_FORMAT=10 | |
;SEVCONFIELD 0=AB only | |
;SEVCONFIELD 1=AB and UVW | |
;SEVCONFIELD 2=UVW only | |
;SEVCONFIELD 3=AB and UVW invert | |
;SEVCONFIELD 4=UVW invert only | |
;SEVCONFIELD 5=SIN/COS | |
;SEVCONFIELD 6=Single channel | |
;SEVCONFIELD 7=Single pole pair resolver | |
;SEVCONFIELD 8=Multi pole pair resolver | |
;SEVCONFIELD 9=Sensoless Mode | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4630sub4] | |
ParameterName=Encoder Offset | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=46080 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=Degrees | |
[4640] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Motor Nameplate Data | |
;SEVCONFIELD OBJECT=NAME_PLATE_DATA | |
;SEVCONFIELD SECTION=Motor1PlateData | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4640sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x06 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=6 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4640sub1] | |
ParameterName=Rated line voltage | |
ParameterValue=0x0280 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=Vrms | |
;SEVCONFIELD EEPROM=misc.nameplate_rated_line_volts | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4640sub2] | |
ParameterName=Rated phase current | |
ParameterValue=0x0590 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=Arms | |
;SEVCONFIELD EEPROM=misc.nameplate_rated_phase_current | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4640sub3] | |
ParameterName=Rated mechanical speed | |
ParameterValue=0x2710 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=rpm | |
;SEVCONFIELD EEPROM=misc.nameplate_rated_mech_speed | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4640sub4] | |
ParameterName=Rated frequency | |
ParameterValue=0x03c0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=Hz | |
;SEVCONFIELD EEPROM=misc.nameplate_rated_elec_freq | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4640sub5] | |
ParameterName=Rated power | |
ParameterValue=0x00b0 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=Kw | |
;SEVCONFIELD EEPROM=misc.nameplate_rated_power | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4640sub6] | |
ParameterName=Power factor | |
ParameterValue=0x6e14 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000030517578125 | |
;SEVCONFIELD UNITS=sin theta | |
;SEVCONFIELD EEPROM=misc.nameplate_power_factor | |
;SEVCONFIELD SOFT_HIGH=65535 | |
[4641] | |
SubNumber=41 | |
ObjectType=9 | |
ParameterName=AC Motor data (manufacturer specific) | |
;SEVCONFIELD OBJECT=ESPAC_MOTOR_DATA | |
;SEVCONFIELD SECTION=Motor1PlateData | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4641sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x2a | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=49 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4641sub1] | |
ParameterName=Commit | |
ObjectType=7 | |
DataType=1 | |
AccessType=wo | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub2] | |
ParameterName=Maximum Stator Current (Is_max) | |
ParameterValue=0x0226 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=300 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=A(RMS) | |
;SEVCONFIELD EEPROM=motor_0.max_stator_current | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub3] | |
ParameterName=Minimum Magnetizing Current (Im_min) | |
ParameterValue=0x0100 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=1958 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=A(RMS) | |
;SEVCONFIELD EEPROM=motor_0.min_flux_current | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub4] | |
ParameterName=Maximum Magnetizing/Direct Current (Id_max) | |
ParameterValue=0x4b00 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=3917 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.015625 | |
;SEVCONFIELD UNITS=A(RMS) | |
;SEVCONFIELD EEPROM=motor_0.max_flux_current | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub5] | |
ParameterName=Number of Pole Pairs (np) | |
ParameterValue=0x0002 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=66 | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=motor_0.number_of_pole_pairs | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub6] | |
ParameterName=Stator Resistance (Rs) | |
ParameterValue=0x0015 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=82 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.244140625 | |
;SEVCONFIELD UNITS=mOhms | |
;SEVCONFIELD EEPROM=motor_0.stator_resistance | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub7] | |
ParameterName=Rated Stator Current | |
ParameterValue=0x010c | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=2000 | |
PDOMapping=0 | |
DefaultValue=172 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=A(RMS) | |
;SEVCONFIELD EEPROM=motor_0.rated_stator_i | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub8] | |
ParameterName=Rotor Resistance (Rr) | |
ParameterValue=0x0016 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=41 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.244140625 | |
;SEVCONFIELD UNITS=mOhms | |
;SEVCONFIELD EEPROM=motor_0.rotor_resistance | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub9] | |
ParameterName=Magnetizing Inductance (Lm) | |
ParameterValue=0x0057 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=125 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=15.2587890625 | |
;SEVCONFIELD UNITS=uH | |
;SEVCONFIELD EEPROM=motor_0.flux_inductance | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641subA] | |
ParameterName=Stator Leakage Inductance (Lls) | |
ParameterValue=0x0019 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.95367431640625 | |
;SEVCONFIELD UNITS=uH | |
;SEVCONFIELD EEPROM=motor_0.stator_leakage_inductance | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641subB] | |
ParameterName=Rotor Leakage Inductance (Llr) | |
ParameterValue=0x0019 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=21800 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.95367431640625 | |
;SEVCONFIELD UNITS=uH | |
;SEVCONFIELD EEPROM=motor_0.rotor_leakage_inductance | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641subC] | |
ParameterName=Nominal battery voltage | |
ParameterValue=0x0500 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=384 | |
HighLimit=3072 | |
PDOMapping=0 | |
DefaultValue=768 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=motor_0.nom_bat_v | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641subD] | |
ParameterName=Current control proportional gain (Kp) | |
ParameterValue=0x1996 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=22938 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000030517578125 | |
;SEVCONFIELD EEPROM=motor_0.i_ctrl_gain | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641subF] | |
ParameterName=Current control integral gain | |
ParameterValue=0x051d | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=28406 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000030517578125 | |
;SEVCONFIELD EEPROM=motor_0.i_ctrl_discretisation | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub10] | |
ParameterName=Reactive Gain Boost | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=65535 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52587890625E-05 | |
;SEVCONFIELD UNITS=Henry | |
;SEVCONFIELD EEPROM=motor_0.reactive_gain_boost | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub12] | |
ParameterName=Voltage Constant (Ke) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=7864 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000030517578125 | |
;SEVCONFIELD UNITS=V/rads (line, rms, elec_frq) | |
;SEVCONFIELD EEPROM=misc.pm_ke | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub13] | |
ParameterName=Im rated | |
ParameterValue=0x02d6 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32000 | |
PDOMapping=0 | |
DefaultValue=160 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A | |
;SEVCONFIELD EEPROM=misc.motor_im_rated | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub14] | |
ParameterName=Low speed slip | |
ParameterValue=0x0008 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=500 | |
PDOMapping=0 | |
DefaultValue=30 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=rad/s | |
;SEVCONFIELD EEPROM=misc.motor_max_m_slip | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub15] | |
ParameterName=High speed slip | |
ParameterValue=0x0008 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=500 | |
PDOMapping=0 | |
DefaultValue=30 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=rad/s | |
;SEVCONFIELD EEPROM=misc.motor_max_g_slip | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub16] | |
ParameterName=Openloop start speed | |
ParameterValue=0x000a | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=3000 | |
PDOMapping=0 | |
DefaultValue=150 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=9.54929658551372 | |
;SEVCONFIELD UNITS=rpm | |
;SEVCONFIELD EEPROM=misc.motor_openloop_on_speed | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub17] | |
ParameterName=Openloop exit speed | |
ParameterValue=0x0bb8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=3000 | |
PDOMapping=0 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=9.54929658551372 | |
;SEVCONFIELD UNITS=rpm | |
;SEVCONFIELD EEPROM=misc.motor_openloop_off_speed | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub18] | |
ParameterName=Frequency Slope | |
ParameterValue=0x03e8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub19] | |
ParameterName=Frequency/Mod index control Kp | |
ParameterValue=0x001a | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000030517578125 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub1A] | |
ParameterName=Frequency/Mod index control Ki | |
ParameterValue=0x00e6 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000030517578125 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub1B] | |
ParameterName=Slip control Kp | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000030517578125 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub1C] | |
ParameterName=Slip control Ki | |
ParameterValue=0x0300 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000030517578125 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub1D] | |
ParameterName=Slip control factor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=256 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub1E] | |
ParameterName=Max drive mod index | |
ParameterValue=0x1000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x1000 | |
PDOMapping=0 | |
DefaultValue=3891 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0244140625 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub1F] | |
ParameterName=Max brake mod index | |
ParameterValue=0x1000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x1000 | |
PDOMapping=0 | |
DefaultValue=3482 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0244140625 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub20] | |
ParameterName=Ls/Ls' | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD EEPROM=misc.ls_over_ls1 | |
[4641sub21] | |
ParameterName=Voltage Control Kp | |
ParameterValue=0x0ccd | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=8192 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000030517578125 | |
;SEVCONFIELD EEPROM=misc.ac_mtr0_voltage_kp | |
[4641sub22] | |
ParameterName=Voltage Control Ki | |
ParameterValue=0x0100 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=4096 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000030517578125 | |
;SEVCONFIELD EEPROM=misc.ac_mtr0_voltage_ki | |
[4641sub23] | |
ParameterName=start of Frequency cutback | |
ParameterValue=0x0d9a | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x1000 | |
PDOMapping=0 | |
DefaultValue=3481 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0244140625 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub24] | |
ParameterName=start of Voltage cutback | |
ParameterValue=0x0f33 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0x1000 | |
PDOMapping=0 | |
DefaultValue=3686 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0244140625 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub25] | |
ParameterName=Id recovery rate | |
ParameterValue=0x4e20 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=20000 | |
PDOMapping=0 | |
DefaultValue=20000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=A/s | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub26] | |
ParameterName=Ud stabilization factor (open loop slip) | |
ParameterValue=0x0400 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=512 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub27] | |
ParameterName=Iq_min factor (open loop slip) | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=64 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub28] | |
ParameterName=vf gain (open loop slip) | |
ParameterValue=0x0100 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=256 | |
HighLimit=1280 | |
PDOMapping=0 | |
DefaultValue=512 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4641sub29] | |
ParameterName=Stored Rs estimation | |
ParameterValue=0x003f | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.244140625 | |
;SEVCONFIELD UNITS=mOhms | |
[4641sub2A] | |
ParameterName=Iq_ref slew rate | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=800 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0x7FFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=A/s | |
;SEVCONFIELD EEPROM=misc.iq_ref_slew | |
[4650] | |
ParameterName=Miscellaneous DSP configuration | |
ParameterValue=0x0002 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD OBJECT=DSP_MISC_CONFIG | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD EEPROM=misc.dsp_config | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=15 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Encoder wire-off detection | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Enabled | |
;SEVCONFIELD 1=Disabled | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Software overcurrent | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Enabled | |
;SEVCONFIELD 1=Disabled | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Use low speed gains below | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=200rpm | |
;SEVCONFIELD 1=50rpm | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Sin-cos PLL (PMAC) / Closed loop slip compensation (IM) | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=Scale max torque by power limit | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Gain Scheduling | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=Allow drv/brk trq inhibit to 0 RPM | |
;SEVCONFIELD BITMASK=0x40 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=7 | |
;SEVCONFIELD PARAMETERNAME=Motor open circuit detection | |
;SEVCONFIELD BITMASK=0x80 | |
;SEVCONFIELD BITSHIFT=0x7 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=8 | |
;SEVCONFIELD PARAMETERNAME=Speed dependent field weakening | |
;SEVCONFIELD BITMASK=0x100 | |
;SEVCONFIELD BITSHIFT=0x8 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=9 | |
;SEVCONFIELD PARAMETERNAME=Motor fault state (PMAC only) | |
;SEVCONFIELD BITMASK=0x200 | |
;SEVCONFIELD BITSHIFT=0x9 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Open Circuit | |
;SEVCONFIELD 1=Short Circuit | |
;SEVCONFIELD SPLIT=10 | |
;SEVCONFIELD PARAMETERNAME=Bypass DC link discharge at power on (PMAC Only) | |
;SEVCONFIELD BITMASK=0x400 | |
;SEVCONFIELD BITSHIFT=0xA | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Discharge | |
;SEVCONFIELD 1=Bypass | |
;SEVCONFIELD SPLIT=11 | |
;SEVCONFIELD PARAMETERNAME=Use lookup tables for demand (IMPM PMAC only) | |
;SEVCONFIELD BITMASK=0x800 | |
;SEVCONFIELD BITSHIFT=0xB | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=12 | |
;SEVCONFIELD PARAMETERNAME=Switching freq allowed to change to - reduce thermal losses (PMAC) / control low field currents (DC-SEM) | |
;SEVCONFIELD BITMASK=0x1000 | |
;SEVCONFIELD BITSHIFT=0xC | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Yes | |
;SEVCONFIELD 1=No | |
;SEVCONFIELD SPLIT=13 | |
;SEVCONFIELD PARAMETERNAME=Motor Forward and Reverse Speed Limits | |
;SEVCONFIELD BITMASK=0x2000 | |
;SEVCONFIELD BITSHIFT=0xD | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Applied in drive direction only | |
;SEVCONFIELD 1=Equal and opposite | |
;SEVCONFIELD SPLIT=14 | |
;SEVCONFIELD PARAMETERNAME=SinCos MinMax Tracking | |
;SEVCONFIELD BITMASK=0x8000 | |
;SEVCONFIELD BITSHIFT=0xF | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Enabled | |
;SEVCONFIELD 1=Disabled | |
[4651] | |
SubNumber=10 | |
ObjectType=9 | |
ParameterName=Speed control Gains | |
;SEVCONFIELD OBJECT=VELOCITY_CONTROL_PARAM | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4651sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x09 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=12 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4651sub1] | |
ParameterName=Proportional gain | |
ParameterValue=0x0080 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0x80 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000244140625 | |
;SEVCONFIELD EEPROM=motor_0.vel_ctrl_kp | |
[4651sub2] | |
ParameterName=Integral gain | |
ParameterValue=0x0002 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0x40 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD EEPROM=motor_0.vel_ctrl_ki | |
[4651sub3] | |
ParameterName=Low Speed proportional gain | |
ParameterValue=0x1000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000244140625 | |
;SEVCONFIELD EEPROM=misc.pv_config_vel_control_kp_low | |
[4651sub4] | |
ParameterName=Rollback integral gain | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD EEPROM=misc.pv_config_vel_control_ki_rollback | |
[4651sub5] | |
ParameterName=Low speed integral gain | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD EEPROM=misc.pv_config_vel_control_ki_low | |
[4651sub6] | |
ParameterName=dw/dt gain | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=32767 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD EEPROM=misc.pv_config_vel_control_dw_dt | |
[4651sub7] | |
ParameterName=Integral initialization factor | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=4096 | |
PDOMapping=0 | |
DefaultValue=0x1000 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.000244140625 | |
;SEVCONFIELD EEPROM=misc.ac_mtr0_vel_ctrl_integral_init | |
[4651sub8] | |
ParameterName=Speed calculation filter pole | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0xF384 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1.52587890625E-05 | |
;SEVCONFIELD EEPROM=misc.ac_mtr0_trq_ctrl_speed_filter | |
[4651sub9] | |
ParameterName=Pre-limit speed | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=100 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=rpm | |
;SEVCONFIELD EEPROM=misc.ac_mtr0_pre_limit_speed | |
[4653] | |
ParameterName=Temporary DSP Configuration | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=DSP_MISC_CONFIG | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=3 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Current Control Quality Monitor (PMAC / DC only) | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Enabled | |
;SEVCONFIELD 1=Disabled | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME= Force low-frequency PWM mode (DC-SEM field and PMAC Gen4 size8/10 only) | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Force Field Established (DC-SEM only) | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD 0=Disabled | |
[4654] | |
ParameterName=Current sensor autozero range | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=60 | |
PDOMapping=0 | |
DefaultValue=60 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=A | |
;SEVCONFIELD OBJECT=MOTOR_AZ_RANGE_CONFIG | |
;SEVCONFIELD SECTION=MOTOR1SETUP | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4680] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=General Digital Input Configuration | |
;SEVCONFIELD OBJECT=DIG_IN_CONFIG | |
;SEVCONFIELD SECTION=DIConfiguration | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4680sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4680sub1] | |
ParameterName=Inputs active | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=io.lcl_di_pullup | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Low | |
;SEVCONFIELD 1=High | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[4681] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=Digital Input Wire-Off Detection Enable | |
;SEVCONFIELD OBJECT=DIG_IN_WIRE_OFF_CONFIG | |
;SEVCONFIELD SECTION=DIConfiguration | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4681sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4681sub1] | |
ParameterName=Digital Input wire-off enable | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=io.lcl_di_wire_off_enable_0 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=2 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=Digital Input Wire-Off 1 | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Digital Input Wire-Off 2 | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
[4690] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=General Analog Input Configuration | |
;SEVCONFIELD OBJECT=ALG_IN_CONFIG | |
;SEVCONFIELD SECTION=AIConfiguration | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[4690sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[4690sub1] | |
ParameterName=Analog input as Digital - Inactive Voltage | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=8 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=io.lcl_ai_dig_off_v | |
[4690sub2] | |
ParameterName=Analog input as Digital - Active Voltage | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=56 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=io.lcl_ai_dig_on_v | |
[46A1] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=Analog Output Current / Voltage mode | |
;SEVCONFIELD OBJECT=ALG_OUT_I_MODE_ENABLE | |
;SEVCONFIELD SECTION=AOConfiguration | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[46A1sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[46A1sub1] | |
ParameterName=Analog Outputs 1..8, current / voltage mode selection. | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=io.lcl_ao_v_or_i_mode_0 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[46A2] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=Analog Output Auxiliary Frequency | |
;SEVCONFIELD OBJECT=ALG_OUT_AUX_FREQ | |
;SEVCONFIELD SECTION=AOConfiguration | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[46A2sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[46A2sub1] | |
ParameterName=Analog Output Auxiliary Frequency | |
ParameterValue=0x03e8 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=40 | |
HighLimit=1000 | |
PDOMapping=0 | |
DefaultValue=40 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD UNITS=Hz | |
;SEVCONFIELD EEPROM=io.lcl_ao_aux_freq | |
[46A3] | |
SubNumber=2 | |
ObjectType=9 | |
ParameterName=Analog Output Frequency Selection | |
;SEVCONFIELD OBJECT=ALG_OUT_FREQ_SELECT | |
;SEVCONFIELD SECTION=AOConfiguration | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[46A3sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[46A3sub1] | |
ParameterName=Analog Outputs 1..8, 16kHz or auxiliary frequency selection. | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=io.lcl_ao_freq_select | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[46C0] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Analogue Input 1 Range | |
;SEVCONFIELD OBJECT=ALG_IN_VOLTAGE_RANGE | |
;SEVCONFIELD SECTION=AIConfiguration | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[46C0sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[46C0sub1] | |
ParameterName=Minimum allowed voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=misc.analogue_input_min_vals[0] | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[46C0sub2] | |
ParameterName=Maximum allowed voltage | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0xFFFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=misc.analogue_input_max_vals[0] | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[46C1] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Analogue Input 2 Range | |
;SEVCONFIELD OBJECT=ALG_IN_VOLTAGE_RANGE | |
;SEVCONFIELD SECTION=AIConfiguration | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[46C1sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[46C1sub1] | |
ParameterName=Minimum allowed voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=misc.analogue_input_min_vals[1] | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[46C1sub2] | |
ParameterName=Maximum allowed voltage | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0xFFFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=misc.analogue_input_max_vals[1] | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[46C2] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Analogue Input 3 Range | |
;SEVCONFIELD OBJECT=ALG_IN_VOLTAGE_RANGE | |
;SEVCONFIELD SECTION=AIConfiguration | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[46C2sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[46C2sub1] | |
ParameterName=Minimum allowed voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=misc.analogue_input_min_vals[2] | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[46C2sub2] | |
ParameterName=Maximum allowed voltage | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0xFFFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=misc.analogue_input_max_vals[2] | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[46C3] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Analogue Input 4 Range | |
;SEVCONFIELD OBJECT=ALG_IN_VOLTAGE_RANGE | |
;SEVCONFIELD SECTION=AIConfiguration | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[46C3sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[46C3sub1] | |
ParameterName=Minimum allowed voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=misc.analogue_input_min_vals[3] | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[46C3sub2] | |
ParameterName=Maximum allowed voltage | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0xFFFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=misc.analogue_input_max_vals[3] | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[46C4] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Analogue Input 5 Range | |
;SEVCONFIELD OBJECT=ALG_IN_VOLTAGE_RANGE | |
;SEVCONFIELD SECTION=AIConfiguration | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[46C4sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[46C4sub1] | |
ParameterName=Minimum allowed voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=misc.analogue_input_min_vals[4] | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[46C4sub2] | |
ParameterName=Maximum allowed voltage | |
ParameterValue=0xffff | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0xFFFF | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=misc.analogue_input_max_vals[4] | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[46D0] | |
SubNumber=6 | |
ObjectType=9 | |
ParameterName=Analog input resistances | |
;SEVCONFIELD OBJECT=READ_ALG_IN_RESISTANCE_16_BIT | |
;SEVCONFIELD SECTION=AIStatus | |
;SEVCONFIELD CATEGORY=MONITORING | |
[46D0sub0] | |
ParameterName=Number of analog inputs | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=8 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[46D0sub1] | |
ParameterName=Analog input 1 resistance | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=Ohms | |
[46D0sub2] | |
ParameterName=Analog input 2 resistance | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=Ohms | |
[46D0sub3] | |
ParameterName=Analog input 3 resistance | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=Ohms | |
[46D0sub4] | |
ParameterName=Analog input 4 resistance | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=Ohms | |
[46D0sub5] | |
ParameterName=Analog input 5 resistance | |
ParameterValue=0x7fff | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=Ohms | |
[5000] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Password Entry | |
;SEVCONFIELD OBJECT=PASSWORD | |
;SEVCONFIELD SECTION=Security | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5000sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5000sub1] | |
ParameterName=Access Level Indication | |
ParameterValue=0x04 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=5 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=6 | |
;SEVCONFIELD 0=Not logged in | |
;SEVCONFIELD 1=User | |
;SEVCONFIELD 2=Dealer | |
;SEVCONFIELD 3=Production | |
;SEVCONFIELD 4=Engineering | |
;SEVCONFIELD 5=SEVCON | |
[5000sub2] | |
ParameterName=Password (16-bit) | |
ObjectType=7 | |
DataType=6 | |
AccessType=wo | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[5000sub3] | |
ParameterName=User ID | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[5001] | |
ParameterName=Password Key | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=5 | |
;SEVCONFIELD OBJECT=PASSWORD_KEY | |
;SEVCONFIELD SECTION=Security | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5100] | |
SubNumber=8 | |
ObjectType=9 | |
ParameterName=Device Measurements | |
;SEVCONFIELD OBJECT=DEVICE_MEASUREMENTS | |
;SEVCONFIELD SECTION=VEHICLESTATUS | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5100sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x08 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=9 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5100sub1] | |
ParameterName=Battery Voltage | |
ParameterValue=0x0550 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
[5100sub2] | |
ParameterName=Battery Current | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=3 | |
AccessType=ro | |
LowLimit=0x8000 | |
HighLimit=0x7FFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=A | |
[5100sub3] | |
ParameterName=Capacitor Voltage | |
ParameterValue=0x00ad | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
[5100sub4] | |
ParameterName=Heatsink Temperature | |
ParameterValue=0x16 | |
ObjectType=7 | |
DataType=2 | |
AccessType=ro | |
LowLimit=-128 | |
HighLimit=127 | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=DegC | |
[5100sub6] | |
ParameterName=Battery Voltage (8-bit) | |
ParameterValue=0xff | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=V | |
[5100sub7] | |
ParameterName=Capacitor Voltage (8-bit) | |
ParameterValue=0x2b | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=V | |
[5100sub8] | |
ParameterName=Logic 12V supply | |
ParameterValue=0x0cd4 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
[5110] | |
ParameterName=NMT State | |
ParameterValue=0x7f | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=NMT_STATE | |
;SEVCONFIELD SECTION=CANOPEN_GENERALSTATUS | |
;SEVCONFIELD NUMBER_FORMAT=3 | |
;SEVCONFIELD 4=Stopped | |
;SEVCONFIELD 5=Operational | |
;SEVCONFIELD 127=Pre-Operational | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5180] | |
ParameterName=Capacitor Precharge activate | |
ObjectType=7 | |
DataType=5 | |
AccessType=wo | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=NODE_CAP_PRECHARGE | |
;SEVCONFIELD SECTION=VEHICLECONFIG | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5200] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Controller key hours | |
;SEVCONFIELD OBJECT=CONTROLLER_HOURS | |
;SEVCONFIELD SECTION=HoursCounters | |
;SEVCONFIELD CATEGORY=LOGGING | |
[5200sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5200sub1] | |
ParameterName=Hours | |
ParameterValue=0x0031 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD UNITS=Hours | |
[5200sub2] | |
ParameterName=Minutes / Seconds | |
ParameterValue=0xb5 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xEf | |
PDOMapping=1 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.25 | |
;SEVCONFIELD UNITS=Minutes | |
[5300] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=Node fault information | |
;SEVCONFIELD OBJECT=NODE_FAULT_INFO | |
;SEVCONFIELD SECTION=ActiveFaultLog | |
;SEVCONFIELD CATEGORY=LOGGING | |
[5300sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5300sub1] | |
ParameterName=Number of faults currently active. | |
ParameterValue=0x0001 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5300sub2] | |
ParameterName=Select position in fault list to read from 5300h, 3 | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5300sub3] | |
ParameterName=ID of Fault at position selected in 5300h, 2. | |
ParameterValue=0x4681 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[5310] | |
ParameterName=CANopen General Error Abort Code | |
ParameterValue=0x0003 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=GENERAL_ABORT_CODE | |
;SEVCONFIELD SECTION=CANOPEN_GENERALSTATUS | |
;SEVCONFIELD NUMBER_FORMAT=21 | |
;SEVCONFIELD 0=None | |
;SEVCONFIELD 1=General | |
;SEVCONFIELD 2=Nothing to Transmit | |
;SEVCONFIELD 3=Invalid Service | |
;SEVCONFIELD 4=Not In Preoperational | |
;SEVCONFIELD 5=Not In Operational | |
;SEVCONFIELD 6=Cannot goto Preoperational | |
;SEVCONFIELD 7=Cannot goto Operational | |
;SEVCONFIELD 8=Access Level too low | |
;SEVCONFIELD 9=Login Failed | |
;SEVCONFIELD 10=Range Underflow | |
;SEVCONFIELD 11=Range Overflow | |
;SEVCONFIELD 12=Invalid Value | |
;SEVCONFIELD 13=EEPROM Update Failed | |
;SEVCONFIELD 14=Cannot reset Service Time | |
;SEVCONFIELD 15=Cannot Reset Log | |
;SEVCONFIELD 16=Cannot Read Log | |
;SEVCONFIELD 17=Invalid Store Command | |
;SEVCONFIELD 18=Bootloader Failure | |
;SEVCONFIELD 19=DSP Update Failed | |
;SEVCONFIELD 20=GIO Update Failed | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5320] | |
ParameterName=Currently active highest priority fault | |
ParameterValue=0x4681 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=NODE_HIGHEST_PRIORITY_FAULT | |
;SEVCONFIELD SECTION=ActiveFaultLog | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5400] | |
ParameterName=Bootloader Activate | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD OBJECT=BOOTLOADER_INIT | |
;SEVCONFIELD SECTION=CANOPEN_GENERALCONTROL | |
;SEVCONFIELD COMMS_TIMEOUT=1 | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5500] | |
ParameterName=NVM Format | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=NVM_FORMAT | |
;SEVCONFIELD SECTION=Identity | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5501] | |
ParameterName=Internal ROM Checksum | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=INTERNAL_ROM_CHECKSUM | |
;SEVCONFIELD SECTION=Identity | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5502] | |
ParameterName=External ROM Checksum | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=EXTERNAL_ROM_CHECKSUM | |
;SEVCONFIELD SECTION=Identity | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5600] | |
SubNumber=10 | |
ObjectType=9 | |
ParameterName=Node domain uploads | |
;SEVCONFIELD OBJECT=DOMAIN_UPLOAD | |
;SEVCONFIELD SECTION=DomainLogs | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5600sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x0a | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=9 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5600sub1] | |
ParameterName=System FIFO | |
ParameterValue=0x00ff00ff00ff0061001a344100ff00ff00ff0050001a344100ff00ff00ff00de000f344100ff00ff00ff00ad000f344100ff00ff00ff0090000a3441000900bf0020007a000a344100ff00ff00ff004e000a3441000900bf00200005000a344100ff00ff00ff00dd00093441000200c20020001800073441 | |
ObjectType=7 | |
DataType=15 | |
AccessType=ro | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD COMMS_TIMEOUT=20000 | |
[5600sub2] | |
ParameterName=Faults FIFO | |
ParameterValue=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 | |
ObjectType=7 | |
DataType=15 | |
AccessType=ro | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD COMMS_TIMEOUT=20000 | |
[5600sub3] | |
ParameterName=Event Counters | |
ParameterValue=0x001f00240030001800075043000100610020006100204f55000a0061001a001800073441000200c7001a0003001854c100410003003000a9000150440002001900070018000752c4000900ec002f0038001e4f410002001500160005001651c20033009e00130000000051010013008c002d0067001a4f4c | |
ObjectType=7 | |
DataType=15 | |
AccessType=ro | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD COMMS_TIMEOUT=20000 | |
[5600sub4] | |
ParameterName=Customer Operational Monitor | |
ParameterValue=0x00410012116ef6ea80007fff02c800000658000006680278 | |
ObjectType=7 | |
DataType=15 | |
AccessType=ro | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD COMMS_TIMEOUT=20000 | |
[5600sub5] | |
ParameterName=Sevcon Operational Monitor | |
ParameterValue=0x00400012116ef6ea80007fff02400000065f007606500288 | |
ObjectType=7 | |
DataType=15 | |
AccessType=ro | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD COMMS_TIMEOUT=20000 | |
[5600sub6] | |
ParameterName=Active Fault List | |
ParameterValue=0x4681 | |
ObjectType=7 | |
DataType=15 | |
AccessType=ro | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD COMMS_TIMEOUT=20000 | |
[5600sub7] | |
ParameterName=Debug | |
ParameterValue=0x0002000000460000001a0001000a000000460052001a5044000a005100460052001a5043000a03e817700000000007d007d007d000000000001a5043000000000000000000000000 | |
ObjectType=7 | |
DataType=15 | |
AccessType=ro | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD COMMS_TIMEOUT=20000 | |
[5600sub8] | |
ParameterName=CLI In | |
ObjectType=7 | |
DataType=15 | |
AccessType=wo | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD COMMS_TIMEOUT=20000 | |
[5600subA] | |
ParameterName=Event List | |
ParameterValue=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 | |
ObjectType=7 | |
DataType=15 | |
AccessType=ro | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD COMMS_TIMEOUT=40000 | |
[5601] | |
SubNumber=6 | |
ObjectType=9 | |
ParameterName=Indirect Object Update | |
;SEVCONFIELD OBJECT=INDIRECT_OBJECT_UPDATE | |
;SEVCONFIELD SECTION=CANOPEN_GENERALCONTROL | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5601sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=4 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5601sub1] | |
ParameterName=Index | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[5601sub2] | |
ParameterName=Sub-Index | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFE | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[5601sub3] | |
ParameterName=New Value | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[5601sub4] | |
ParameterName=Seed/Unlock code | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[5601sub5] | |
ParameterName=Result | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[5602] | |
SubNumber=6 | |
ObjectType=9 | |
ParameterName=Debug object | |
;SEVCONFIELD OBJECT=DEBUG_CONTROL | |
;SEVCONFIELD SECTION=CANOPEN_GENERALCONTROL | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5602sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=19 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5602sub1] | |
ParameterName=Debug value 1 | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5602sub2] | |
ParameterName=Debug value 2 | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5602sub3] | |
ParameterName=Debug value 3 | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5602sub4] | |
ParameterName=Debug value 4 | |
ParameterValue=0x00000000 | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5602sub5] | |
ParameterName=Enable debug output | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5603] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Host/DSP Memory peek | |
;SEVCONFIELD OBJECT=MEMORY_PEEK | |
;SEVCONFIELD SECTION=CANOPEN_GENERALCONTROL | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5603sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x04 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=4 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5603sub3] | |
ParameterName=Slave address | |
ObjectType=7 | |
DataType=7 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFFFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=5 | |
[5603sub4] | |
ParameterName=Slave 16-bit value | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=2 | |
;SEVCONFIELD ACCESS_LEVEL=5 | |
[5604] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=DSP Trace Object | |
;SEVCONFIELD OBJECT=DSP_DETAILED_TRACE | |
;SEVCONFIELD SECTION=CANOPEN_GENERALSTATUS | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5604sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5604sub1] | |
ParameterName=Trace Index | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
[5604sub2] | |
ParameterName=Trace Data | |
ObjectType=7 | |
DataType=15 | |
AccessType=ro | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5605] | |
SubNumber=10 | |
ObjectType=9 | |
ParameterName=Timing Analysis | |
;SEVCONFIELD OBJECT=TIMING_ANALYSIS | |
;SEVCONFIELD SECTION=NODE_STATUS | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5605sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x09 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=9 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5605sub1] | |
ParameterName=ID | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5605sub2] | |
ParameterName=Sample rate | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5605sub3] | |
ParameterName=Periodic Minimum Time | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.4 | |
;SEVCONFIELD UNITS=us | |
[5605sub4] | |
ParameterName=Periodic Maximum Time | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.4 | |
;SEVCONFIELD UNITS=us | |
[5605sub5] | |
ParameterName=Periodic Average Time | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.4 | |
;SEVCONFIELD UNITS=us | |
[5605sub6] | |
ParameterName=Interval Minimum Time | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.4 | |
;SEVCONFIELD UNITS=us | |
[5605sub7] | |
ParameterName=Interval Maximum Time | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.4 | |
;SEVCONFIELD UNITS=us | |
[5605sub8] | |
ParameterName=Interval Average Time | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD SCALING=0.4 | |
;SEVCONFIELD UNITS=us | |
[5605sub9] | |
ParameterName=Interval Overflow Counter | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=1 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5610] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Event information | |
;SEVCONFIELD OBJECT=EVENT_ID_DESCRIPTION | |
;SEVCONFIELD SECTION=DomainLogs | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5610sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5610sub1] | |
ParameterName=Event ID | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[5610sub2] | |
ParameterName=Event Name | |
ParameterValue=<Event ID Unknown> | |
ObjectType=7 | |
DataType=9 | |
AccessType=ro | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5620] | |
ParameterName=Configuration Checksum | |
ParameterValue=0xe87f | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD OBJECT=CONFIG_CHECKSUM | |
;SEVCONFIELD SECTION=CANOPEN_GENERALSTATUS | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5621] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Range Check Failed Objects | |
;SEVCONFIELD OBJECT=RANGE_CHECK_FAILED_OBJECT | |
;SEVCONFIELD SECTION=VEHICLESTATUS | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5621sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5621sub1] | |
ParameterName=Index | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x1 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[5621sub2] | |
ParameterName=Sub-index | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BASE16 | |
[5630] | |
SubNumber=12 | |
ObjectType=9 | |
ParameterName=EDS Upload | |
;SEVCONFIELD OBJECT=EDS_UPLOAD | |
;SEVCONFIELD SECTION=CANOPEN_GENERALSTATUS | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5630sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x0b | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=10 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5630sub1] | |
ParameterName=OD table index | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5630sub2] | |
ParameterName=Index | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5630sub3] | |
ParameterName=Sub-Index | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5630sub4] | |
ParameterName=Object Type | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5630sub5] | |
ParameterName=Data Type | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=15 | |
;SEVCONFIELD 0=Boolean | |
;SEVCONFIELD 1=Integer8 | |
;SEVCONFIELD 2=Integer16 | |
;SEVCONFIELD 3=Integer32 | |
;SEVCONFIELD 4=Integer64 | |
;SEVCONFIELD 5=Unsigned8 | |
;SEVCONFIELD 6=Unsigned16 | |
;SEVCONFIELD 7=Unsigned32 | |
;SEVCONFIELD 8=Unsigned64 | |
;SEVCONFIELD 9=VisibleString | |
;SEVCONFIELD 10=Domain | |
;SEVCONFIELD 11=OctetString | |
;SEVCONFIELD 12=Real32 | |
;SEVCONFIELD 13=Real64 | |
;SEVCONFIELD 14=Void | |
;SEVCONFIELD 15=Domain | |
[5630sub6] | |
ParameterName=Access | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=4 | |
;SEVCONFIELD 0=ro | |
;SEVCONFIELD 1=wo | |
;SEVCONFIELD 2=rw | |
;SEVCONFIELD 3=const | |
[5630sub7] | |
ParameterName=Low Limit | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5630sub8] | |
ParameterName=High Limit | |
ObjectType=7 | |
DataType=7 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5630sub9] | |
ParameterName=PDO Mappable? | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5630subA] | |
ParameterName=Object Version | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5630subB] | |
ParameterName=Object Flags | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5631] | |
SubNumber=4 | |
ObjectType=9 | |
ParameterName=EDS Upload - Information | |
;SEVCONFIELD OBJECT=EDS_UPLOAD_INFO | |
;SEVCONFIELD SECTION=CANOPEN_GENERALSTATUS | |
;SEVCONFIELD CATEGORY=MONITORING | |
[5631sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x03 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5631sub1] | |
ParameterName=Supported Baudrates | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=8 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=10kHz | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=20kHz | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=50kHz | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=125kHz | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=250kHz | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=500kHz | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=800kHz | |
;SEVCONFIELD BITMASK=0x40 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=7 | |
;SEVCONFIELD PARAMETERNAME=1MHz | |
;SEVCONFIELD BITMASK=0x80 | |
;SEVCONFIELD BITSHIFT=0x7 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
[5631sub2] | |
ParameterName=LSS supported? | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
[5631sub3] | |
ParameterName=Supported Dummy RPDO maps | |
ObjectType=7 | |
DataType=6 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
ObjFlags=0x3 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=7 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=BOOLEAN | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=INTEGER8 | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=INTEGER16 | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=INTEGER32 | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=UNSIGNED8 | |
;SEVCONFIELD BITMASK=0x10 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=UNSIGNED16 | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=UNSIGNED32 | |
;SEVCONFIELD BITMASK=0x40 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
[5800] | |
ParameterName=Master / Slave configuration | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=MASTER_SLAVE_CONFIG | |
;SEVCONFIELD SECTION=CANopenSetup | |
;SEVCONFIELD EEPROM=node.is_master | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Slave | |
;SEVCONFIELD 1=Master | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[5810] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Automatic Configuration Set Up | |
;SEVCONFIELD OBJECT=PHYSICAL_LAYER_SETTINGS | |
;SEVCONFIELD SECTION=CANopenSetup | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[5810sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x07 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=7 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5810sub1] | |
ParameterName=Ctrl Flags | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=6 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=CANopen Auto Configuration | |
;SEVCONFIELD BITMASK=0x3 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Digital Input Auto Configuration | |
;SEVCONFIELD BITMASK=0xC | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=3 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=VPDO Only | |
;SEVCONFIELD 2=PDO Only | |
;SEVCONFIELD 3=Both PDO and VPDO | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Digital Output Auto Configuration | |
;SEVCONFIELD BITMASK=0x30 | |
;SEVCONFIELD BITSHIFT=0x4 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=3 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=VPDO Only | |
;SEVCONFIELD 2=PDO Only | |
;SEVCONFIELD 3=Both PDO and VPDO | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Analogue Input Auto Configuration | |
;SEVCONFIELD BITMASK=0xC0 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=3 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=VPDO Only | |
;SEVCONFIELD 2=PDO Only | |
;SEVCONFIELD 3=Both PDO and VPDO | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=Analogue Output Auto Configuration | |
;SEVCONFIELD BITMASK=0x300 | |
;SEVCONFIELD BITSHIFT=0x8 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=3 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=VPDO Only | |
;SEVCONFIELD 2=PDO Only | |
;SEVCONFIELD 3=Both PDO and VPDO | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=Motor Auto Configuration | |
;SEVCONFIELD BITMASK=0xC00 | |
;SEVCONFIELD BITSHIFT=0xA | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=3 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=VPDO Only | |
;SEVCONFIELD 2=PDO Only | |
;SEVCONFIELD 3=Both PDO and VPDO | |
[5810sub2] | |
ParameterName=CANopen Network Description | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=7 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=This node is a | |
;SEVCONFIELD BITMASK=0x1F | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=6 | |
;SEVCONFIELD NUMBERFORMAT=6 | |
;SEVCONFIELD 0=Slave | |
;SEVCONFIELD 1=Master(local is left traction) | |
;SEVCONFIELD 2=Master(local is right traction) | |
;SEVCONFIELD 3=Master(local is pump) | |
;SEVCONFIELD 4=Master(local is power steer) | |
;SEVCONFIELD 5=Master(io module or other) | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Left Traction | |
;SEVCONFIELD BITMASK=0x20 | |
;SEVCONFIELD BITSHIFT=0x5 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Right Traction | |
;SEVCONFIELD BITMASK=0x40 | |
;SEVCONFIELD BITSHIFT=0x6 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Pump | |
;SEVCONFIELD BITMASK=0x80 | |
;SEVCONFIELD BITSHIFT=0x7 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=4 | |
;SEVCONFIELD PARAMETERNAME=Power Steer | |
;SEVCONFIELD BITMASK=0x100 | |
;SEVCONFIELD BITSHIFT=0x8 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=5 | |
;SEVCONFIELD PARAMETERNAME=not used | |
;SEVCONFIELD BITMASK=0x200 | |
;SEVCONFIELD BITSHIFT=0x9 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
;SEVCONFIELD SPLIT=6 | |
;SEVCONFIELD PARAMETERNAME=Sevcon PST Module | |
;SEVCONFIELD BITMASK=0x400 | |
;SEVCONFIELD BITSHIFT=0xA | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=No | |
;SEVCONFIELD 1=Yes | |
[5810sub3] | |
ParameterName=Digital Input Configuration | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=11 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
[5810sub5] | |
ParameterName=Analogue Input Configuration | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=7 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
[5810sub6] | |
ParameterName=Analogue Output Configuration | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=13 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
[5810sub7] | |
ParameterName=Valid configurations | |
ParameterValue=0x003c | |
ObjectType=7 | |
DataType=15 | |
AccessType=ro | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
[5811] | |
SubNumber=7 | |
ObjectType=9 | |
ParameterName=Automatic Configuration Set Up | |
;SEVCONFIELD OBJECT=PHYSICAL_LAYER_SETTINGS | |
;SEVCONFIELD SECTION=CANopenSetup | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[5811sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x07 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=7 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5811sub1] | |
ParameterName=Digital Input Slave Config | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=13 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
[5811sub3] | |
ParameterName=Analogue Input Slave Config | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=5 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
[5811sub4] | |
ParameterName=Analogue Output Slave Config | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=3 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
[5811sub5] | |
ParameterName=Motors slave config | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
[5811sub6] | |
ParameterName=Display Options | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
[5811sub7] | |
ParameterName=Complete | |
ObjectType=7 | |
DataType=1 | |
AccessType=wo | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
[5820] | |
ParameterName=Final precharge level | |
ParameterValue=0x5a | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=50 | |
HighLimit=90 | |
PDOMapping=0 | |
DefaultValue=90 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=% | |
;SEVCONFIELD OBJECT=FINAL_PRECHARGE_LEVEL | |
;SEVCONFIELD SECTION=NodeSetup | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[5821] | |
ParameterName=Minimum precharge level | |
ParameterValue=0x0140 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0x0050 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0x00A0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.0625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD OBJECT=FINAL_PRECHARGE_LEVEL | |
;SEVCONFIELD SECTION=NodeSetup | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[5830] | |
ParameterName=PWM Configuration | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=DSP_MISC_CONFIG | |
;SEVCONFIELD SECTION=NodeSetup | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT | |
;SEVCONFIELD NUMBER_SPLIT=4 | |
;SEVCONFIELD SPLIT=0 | |
;SEVCONFIELD PARAMETERNAME=PWM Switching Frequency | |
;SEVCONFIELD BITMASK=0x1 | |
;SEVCONFIELD BITSHIFT=0x0 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=8kHz | |
;SEVCONFIELD 1=12kHz | |
;SEVCONFIELD SPLIT=1 | |
;SEVCONFIELD PARAMETERNAME=Deadtime Compensation | |
;SEVCONFIELD BITMASK=0x2 | |
;SEVCONFIELD BITSHIFT=0x1 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Enabled | |
;SEVCONFIELD 1=Disabled | |
;SEVCONFIELD SPLIT=2 | |
;SEVCONFIELD PARAMETERNAME=Reserved PWM mode | |
;SEVCONFIELD BITMASK=0x4 | |
;SEVCONFIELD BITSHIFT=0x2 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
;SEVCONFIELD SPLIT=3 | |
;SEVCONFIELD PARAMETERNAME=Reserved PWM mode | |
;SEVCONFIELD BITMASK=0x8 | |
;SEVCONFIELD BITSHIFT=0x3 | |
;SEVCONFIELD LOW_LIMIT=0 | |
;SEVCONFIELD HIGH_LIMIT=1 | |
;SEVCONFIELD NUMBERFORMAT=2 | |
;SEVCONFIELD 0=Off | |
;SEVCONFIELD 1=On | |
[5900] | |
SubNumber=3 | |
ObjectType=9 | |
ParameterName=Physical layer settings | |
;SEVCONFIELD OBJECT=PHYSICAL_LAYER_SETTINGS | |
;SEVCONFIELD SECTION=CANopenSetup | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[5900sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x02 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=2 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5900sub1] | |
ParameterName=Node ID | |
ParameterValue=0x01 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=1 | |
HighLimit=127 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=node.node_id | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[5900sub2] | |
ParameterName=Bit rate | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=6 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=node.bit_rate | |
;SEVCONFIELD NUMBER_FORMAT=8 | |
;SEVCONFIELD 0=1Mb | |
;SEVCONFIELD 1=500kb | |
;SEVCONFIELD 2=250kb | |
;SEVCONFIELD 3=125kb | |
;SEVCONFIELD 4=100kb | |
;SEVCONFIELD 5=50kb | |
;SEVCONFIELD 6=20kb | |
;SEVCONFIELD 7=10kb | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[5901] | |
ParameterName=CANbus fault detection on Standalone units | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=1 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=1 | |
PDOMapping=0 | |
DefaultValue=1 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=MASTER_SLAVE_CONFIG | |
;SEVCONFIELD SECTION=CANopenSetup | |
;SEVCONFIELD EEPROM=misc.enable_can_faults | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Enabled | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[5902] | |
ParameterName=RPDO timeout scheme | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=3 | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD OBJECT=RPDO_TIMEOUT_SCHEME | |
;SEVCONFIELD SECTION=CANopenSetup | |
;SEVCONFIELD NUMBER_FORMAT=4 | |
;SEVCONFIELD 0=Disabled | |
;SEVCONFIELD 1=Warn and Slow Down | |
;SEVCONFIELD 2=Inhibit Drive | |
;SEVCONFIELD 3=Severe | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[5A01] | |
SubNumber=6 | |
ObjectType=9 | |
ParameterName=External heat sink fans | |
;SEVCONFIELD OBJECT=HEATSINK_FAN | |
;SEVCONFIELD SECTION=FansConfig | |
;SEVCONFIELD CATEGORY=CONFIGURATION | |
[5A01sub0] | |
ParameterName=Number of entries | |
ParameterValue=0x05 | |
ObjectType=7 | |
DataType=5 | |
AccessType=ro | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=4 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
[5A01sub1] | |
ParameterName=External fan analogue output | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=misc.fan_output | |
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE | |
[5A01sub2] | |
ParameterName=External fan turn on temperature | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=-30 | |
HighLimit=127 | |
PDOMapping=0 | |
DefaultValue=50 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=DegC | |
;SEVCONFIELD EEPROM=misc.fan_on_temperature | |
[5A01sub3] | |
ParameterName=External fan turn off temperature | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=-30 | |
HighLimit=127 | |
PDOMapping=0 | |
DefaultValue=40 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=1 | |
;SEVCONFIELD UNITS=DegC | |
;SEVCONFIELD EEPROM=misc.fan_off_temperature | |
[5A01sub4] | |
ParameterName=Fan voltage | |
ParameterValue=0x0000 | |
ObjectType=7 | |
DataType=6 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFFFF | |
PDOMapping=0 | |
DefaultValue=0x1800 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=2 | |
;SEVCONFIELD SCALING=0.00390625 | |
;SEVCONFIELD UNITS=V | |
;SEVCONFIELD EEPROM=misc.fan_voltage | |
[5A01sub5] | |
ParameterName=Fan Temperature Source | |
ParameterValue=0x00 | |
ObjectType=7 | |
DataType=5 | |
AccessType=rw | |
LowLimit=0 | |
HighLimit=0xFF | |
PDOMapping=0 | |
DefaultValue=0 | |
;SEVCONFIELD OBJECT_VERSION=1 | |
;SEVCONFIELD ACCESS_LEVEL=4 | |
;SEVCONFIELD EEPROM=misc.fan_temperature_selection | |
;SEVCONFIELD NUMBER_FORMAT=2 | |
;SEVCONFIELD 0=Controller heatsink | |
;SEVCONFIELD 1=Motor temperature sensor | |
;SEVCONFIELD | |