Skip to content

Instantly share code, notes, and snippets.

@kasparsd
Created April 22, 2017 23:39
Show Gist options
  • Save kasparsd/1e164f0f9ad1a61448a96deb7bd0682c to your computer and use it in GitHub Desktop.
Save kasparsd/1e164f0f9ad1a61448a96deb7bd0682c to your computer and use it in GitHub Desktop.
[FileInfo]
FileName=C:/Users/Stealth/Desktop/AC24ls.dcf
FileVersion=1
FileRevision=0
EDSVersion=4.0
Description=Gen4 (T,P,PS - slip)29 March 2012 13:20
CreationTime=04:38PM
CreationDate=02-24-2015
CreatedBy=Tech/Ops SEVCON Ltd
ModificationTime=04:38PM
ModificationDate=02-24-2015
ModifiedBy=Tech/Ops SEVCON Ltd
[DeviceInfo]
VendorName=Tech/Ops SEVCON Ltd
ProductName=Gen4
OrderCode=TODO
VendorNumber=0x0000001e
ProductNumber=0x07065037
RevisionNumber=0x00010017
BaudRate_10=0
BaudRate_20=1
BaudRate_50=1
BaudRate_125=1
BaudRate_250=1
BaudRate_500=1
BaudRate_800=0
BaudRate_1000=1
SimpleBootUpMaster=1
SimpleBootUpSlave=1
Granularity=64
GroupMessaging=0
DynamicChannelsSupported=0
NrOfRXPDO=5
NrOfTXPDO=5
LSS_Supported=0
[DeviceComissioning]
NodeID=1
NodeName=
Baudrate=1000
NetNumber=
NetworkName=
CANopenManager=
LSS_SerialNumber=
[Comments]
Lines=1
Line1=A comment.
[DummyUsage]
Dummy0001=1
Dummy0002=0
Dummy0003=0
Dummy0004=0
Dummy0005=1
Dummy0006=1
Dummy0007=1
[MandatoryObjects]
SupportedObjects=3
1=0x1000
2=0x1001
3=0x1018
[1000]
ParameterName=Device type
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=const
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0xFFFF0192
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DEVICE_TYPE
;SEVCONFIELD SECTION=CANOPEN_PROFILEEND
;SEVCONFIELD CATEGORY=MONITORING
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=2
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Type
;SEVCONFIELD BITMASK=0xFFFF
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=0xFFFF
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 402=Electric Drive
;SEVCONFIELD 401=Generic I/O
;SEVCONFIELD 419=Battery charger
;SEVCONFIELD 418=Battery module
;SEVCONFIELD 410 = inclinometer
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Additional data
;SEVCONFIELD BITMASK=0xFFFF0000
;SEVCONFIELD BITSHIFT=0x10
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=0xFFFF
;SEVCONFIELD NUMBERFORMAT=BASE16
[1001]
ParameterName=Error register
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=ERROR_REGISTER
;SEVCONFIELD SECTION=Emergency
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD CATEGORY=MONITORING
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=7
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Generic error
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Cleared
;SEVCONFIELD 1=Set
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Current error
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Cleared
;SEVCONFIELD 1=Set
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Voltage error
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Cleared
;SEVCONFIELD 1=Set
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Temperature error
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Cleared
;SEVCONFIELD 1=Set
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=Comms error
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Cleared
;SEVCONFIELD 1=Set
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Device Profile error
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Cleared
;SEVCONFIELD 1=Set
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=Manf specific error
;SEVCONFIELD BITMASK=0x80
;SEVCONFIELD BITSHIFT=0x7
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Cleared
;SEVCONFIELD 1=Set
[1018]
SubNumber=5
ObjectType=9
ParameterName=Identity object
;SEVCONFIELD OBJECT=IDENTITY
;SEVCONFIELD SECTION=Identity
;SEVCONFIELD CATEGORY=MONITORING
[1018sub0]
ParameterName=Number of entries
ParameterValue=0x04
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=4
;SEVCONFIELD OBJECT_VERSION=1
[1018sub1]
ParameterName=Vendor ID
ParameterValue=0x0000001e
ObjectType=7
DataType=7
AccessType=const
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x0000001E
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1018sub2]
ParameterName=Product code
ParameterValue=0x07065037
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x0101503c
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1018sub3]
ParameterName=CANopen (Object Dictionary) revision
ParameterValue=0x00010017
ObjectType=7
DataType=7
AccessType=const
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x00010001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1018sub4]
ParameterName=Serial number
ParameterValue=0x4d8baf41
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[OptionalObjects]
SupportedObjects=81
1=0x1005
2=0x1006
3=0x1008
4=0x1009
5=0x100A
6=0x1010
7=0x1011
8=0x1014
9=0x1016
10=0x1017
11=0x1200
12=0x1201
13=0x1202
14=0x1203
15=0x1280
16=0x1281
17=0x1282
18=0x1283
19=0x1284
20=0x1285
21=0x1286
22=0x1287
23=0x1400
24=0x1401
25=0x1402
26=0x1403
27=0x1404
28=0x1600
29=0x1601
30=0x1602
31=0x1603
32=0x1604
33=0x1800
34=0x1801
35=0x1802
36=0x1803
37=0x1804
38=0x1A00
39=0x1A01
40=0x1A02
41=0x1A03
42=0x1A04
43=0x6040
44=0x6041
45=0x6060
46=0x6061
47=0x6069
48=0x606B
49=0x606C
50=0x6071
51=0x6072
52=0x6074
53=0x6075
54=0x6076
55=0x6077
56=0x6078
57=0x6079
58=0x607E
59=0x6080
60=0x6083
61=0x6086
62=0x6087
63=0x6088
64=0x608B
65=0x608C
66=0x608D
67=0x608E
68=0x6090
69=0x6095
70=0x6096
71=0x60F8
72=0x60FF
73=0x6502
74=0x67FF
75=0x6800
76=0x6802
77=0x6C01
78=0x6C11
79=0x6C43
80=0x6C44
81=0x6FFF
[1005]
ParameterName=Synchronization (SYNC) message COB-ID
ParameterValue=0x40000080
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x5FFFFFFF
PDOMapping=0
DefaultValue=0x40000080
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=COBID_SYNC
;SEVCONFIELD SECTION=SYNCCOB
;SEVCONFIELD EEPROM=comm.sync_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[1006]
ParameterName=Interval between SYNC messages (Communication cycle period)
ParameterValue=0x00004e20
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0x00002711
HighLimit=0x01F3FC18
PDOMapping=0
DefaultValue=100000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.001
;SEVCONFIELD UNITS=ms
;SEVCONFIELD OBJECT=COMM_CYCLE_PERIOD
;SEVCONFIELD SECTION=SYNCCOB
;SEVCONFIELD EEPROM=comm.cycle_period
;SEVCONFIELD CATEGORY=CONFIGURATION
[1008]
ParameterName=Product name
ParameterValue=Gen4 (T,P,PS - slip)29 March 2012 13:20
ObjectType=7
DataType=9
AccessType=const
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=MANU_DEVICE_NAME
;SEVCONFIELD SECTION=Identity
;SEVCONFIELD CATEGORY=MONITORING
[1009]
ParameterName=Hardware version
ParameterValue=0x00050004
ObjectType=7
DataType=9
AccessType=const
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=MANU_HW_VERSION
;SEVCONFIELD SECTION=Identity
;SEVCONFIELD CATEGORY=MONITORING
[100A]
ParameterName=Software version
ParameterValue=UK0328.24
ObjectType=7
DataType=9
AccessType=const
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=MANU_SW_VERSION
;SEVCONFIELD SECTION=Identity
;SEVCONFIELD CATEGORY=MONITORING
[1010]
SubNumber=2
ObjectType=9
ParameterName=Store command
;SEVCONFIELD OBJECT=STORE
;SEVCONFIELD SECTION=CANOpenStore
;SEVCONFIELD CATEGORY=MONITORING
[1010sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[1010sub1]
ParameterName=Save all parameters
ParameterValue=0x00000001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0x65766173
HighLimit=0x65766173
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0x0=Cancel
;SEVCONFIELD 0x65766173=Save to EEPROM
;SEVCONFIELD COMMS_TIMEOUT=10000
[1011]
SubNumber=2
ObjectType=9
ParameterName=Restore command
;SEVCONFIELD OBJECT=RESTORE
;SEVCONFIELD SECTION=CANOpenStore
;SEVCONFIELD CATEGORY=MONITORING
[1011sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[1011sub1]
ParameterName=Load all parameters
ParameterValue=0x00000001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0x64616F6C
HighLimit=0x64616F6C
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0x0=Cancel
;SEVCONFIELD 0x64616F6C=Load from EEPROM
;SEVCONFIELD COMMS_TIMEOUT=10000
[1014]
ParameterName=Emergency (EMCY) telegram COB-ID
ParameterValue=0x00000081
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x1FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=COBID_EMCY
;SEVCONFIELD SECTION=Emergency
;SEVCONFIELD EEPROM=comm.emergency_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[1016]
SubNumber=8
ObjectType=9
ParameterName=Consumer heartbeat time
;SEVCONFIELD OBJECT=CONSUMER_HBEAT_TIME
;SEVCONFIELD SECTION=Heartbeat
;SEVCONFIELD CATEGORY=CONFIGURATION
[1016sub0]
ParameterName=Number of entries
ParameterValue=0x07
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=7
;SEVCONFIELD OBJECT_VERSION=1
[1016sub1]
ParameterName=Consumer heartbeat time for 1st node
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=comm.con_heartbeat_0
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=2
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=1st node- Heartbeat time
;SEVCONFIELD BITMASK=0xFFFF
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=0xFFFF
;SEVCONFIELD NUMBERFORMAT=BASE10
;SEVCONFIELD UNITS=ms
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=1st node- Node ID
;SEVCONFIELD BITMASK=0xFF0000
;SEVCONFIELD BITSHIFT=0x10
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=127
;SEVCONFIELD NUMBERFORMAT=BASE10
;SEVCONFIELD
[1016sub2]
ParameterName=Consumer heartbeat time for 2nd node
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=comm.con_heartbeat_1
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=2
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=2nd node- Heartbeat time
;SEVCONFIELD BITMASK=0xFFFF
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=0xFFFF
;SEVCONFIELD NUMBERFORMAT=BASE10
;SEVCONFIELD UNITS=ms
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=2nd node- Node ID
;SEVCONFIELD BITMASK=0xFF0000
;SEVCONFIELD BITSHIFT=0x10
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=127
;SEVCONFIELD NUMBERFORMAT=BASE10
[1016sub3]
ParameterName=Consumer heartbeat time for 3rd node
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=comm.con_heartbeat_2
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=2
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=3rd node- Heartbeat time
;SEVCONFIELD BITMASK=0xFFFF
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=0xFFFF
;SEVCONFIELD NUMBERFORMAT=BASE10
;SEVCONFIELD UNITS=ms
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=3rd node- Node ID
;SEVCONFIELD BITMASK=0xFF0000
;SEVCONFIELD BITSHIFT=0x10
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=127
;SEVCONFIELD NUMBERFORMAT=BASE10
[1016sub4]
ParameterName=Consumer heartbeat time for 4th node
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=comm.con_heartbeat_3
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=2
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=4th node- Heartbeat time
;SEVCONFIELD BITMASK=0xFFFF
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=0xFFFF
;SEVCONFIELD NUMBERFORMAT=BASE10
;SEVCONFIELD UNITS=ms
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=4th node- Node ID
;SEVCONFIELD BITMASK=0xFF0000
;SEVCONFIELD BITSHIFT=0x10
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=127
;SEVCONFIELD NUMBERFORMAT=BASE10
[1016sub5]
ParameterName=Consumer heartbeat time for 5th node
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=comm.con_heartbeat_4
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=2
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=5th node- Heartbeat time
;SEVCONFIELD BITMASK=0xFFFF
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=0xFFFF
;SEVCONFIELD NUMBERFORMAT=BASE10
;SEVCONFIELD UNITS=ms
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=5th node- Node ID
;SEVCONFIELD BITMASK=0xFF0000
;SEVCONFIELD BITSHIFT=0x10
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=127
;SEVCONFIELD NUMBERFORMAT=BASE10
[1016sub6]
ParameterName=Consumer heartbeat time for 6th node
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=comm.con_heartbeat_5
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=2
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=6th node- Heartbeat time
;SEVCONFIELD BITMASK=0xFFFF
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=0xFFFF
;SEVCONFIELD NUMBERFORMAT=BASE10
;SEVCONFIELD UNITS=ms
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=6th node- Node ID
;SEVCONFIELD BITMASK=0xFF0000
;SEVCONFIELD BITSHIFT=0x10
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=127
;SEVCONFIELD NUMBERFORMAT=BASE10
[1016sub7]
ParameterName=Consumer heartbeat time for 7th node
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=comm.con_heartbeat_6
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=2
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=7th node- Heartbeat time
;SEVCONFIELD BITMASK=0xFFFF
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=0xFFFF
;SEVCONFIELD NUMBERFORMAT=BASE10
;SEVCONFIELD UNITS=ms
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=7th node- Node ID
;SEVCONFIELD BITMASK=0xFF0000
;SEVCONFIELD BITSHIFT=0x10
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=127
;SEVCONFIELD NUMBERFORMAT=BASE10
[1017]
ParameterName=Producer heartbeat time
ParameterValue=0x01f4
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=500
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=ms
;SEVCONFIELD OBJECT=PRODUCER_HBEAT_TIME
;SEVCONFIELD SECTION=Heartbeat
;SEVCONFIELD EEPROM=comm.heartbeat_reload
;SEVCONFIELD CATEGORY=CONFIGURATION
[1200]
SubNumber=3
ObjectType=9
ParameterName=Server SDO 1 (Default) parameters
;SEVCONFIELD OBJECT=SDO_PARAMETER
;SEVCONFIELD SECTION=ClientServerSDOs
;SEVCONFIELD CATEGORY=CONFIGURATION
[1200sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[1200sub1]
ParameterName=COB-ID Client->Server (rx)
ParameterValue=0x00000601
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=$NODEID+0x600
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1200sub2]
ParameterName=COB-ID Server->Client (tx)
ParameterValue=0x00000581
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=$NODEID+0x580
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1201]
SubNumber=3
ObjectType=9
ParameterName=Server SDO 2 parameters
;SEVCONFIELD OBJECT=SDO_PARAMETER
;SEVCONFIELD SECTION=ClientServerSDOs
;SEVCONFIELD CATEGORY=CONFIGURATION
[1201sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[1201sub1]
ParameterName=COB-ID Client->Server (rx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.ssdo_1.tx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1201sub2]
ParameterName=COB-ID Server->Client (tx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.ssdo_1.rx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1202]
SubNumber=3
ObjectType=9
ParameterName=Server SDO 3 parameters
;SEVCONFIELD OBJECT=SDO_PARAMETER
;SEVCONFIELD SECTION=ClientServerSDOs
;SEVCONFIELD CATEGORY=CONFIGURATION
[1202sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[1202sub1]
ParameterName=COB-ID Client->Server (rx)
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.ssdo_2.tx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1202sub2]
ParameterName=COB-ID Server->Client (tx)
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.ssdo_2.rx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1203]
SubNumber=3
ObjectType=9
ParameterName=Server SDO 4 parameters
;SEVCONFIELD OBJECT=SDO_PARAMETER
;SEVCONFIELD SECTION=ClientServerSDOs
;SEVCONFIELD CATEGORY=CONFIGURATION
[1203sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[1203sub1]
ParameterName=COB-ID Client->Server (rx)
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.ssdo_3.tx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1203sub2]
ParameterName=COB-ID Server->Client (tx)
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.ssdo_3.rx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1280]
SubNumber=4
ObjectType=9
ParameterName=Client SDO 1 parameters
;SEVCONFIELD OBJECT=SDO_PARAMETER
;SEVCONFIELD SECTION=ClientServerSDOs
;SEVCONFIELD CATEGORY=CONFIGURATION
[1280sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[1280sub1]
ParameterName=COB-ID Client->Server (tx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_0.tx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1280sub2]
ParameterName=COB-ID Server->Client (rx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_0.rx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1280sub3]
ParameterName=SDO server Node ID
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=0x7F
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_0.node_id
[1281]
SubNumber=4
ObjectType=9
ParameterName=Client SDO 2 parameters
;SEVCONFIELD OBJECT=SDO_PARAMETER
;SEVCONFIELD SECTION=ClientServerSDOs
;SEVCONFIELD CATEGORY=CONFIGURATION
[1281sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[1281sub1]
ParameterName=COB-ID Client->Server (tx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_1.tx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1281sub2]
ParameterName=COB-ID Server->Client (rx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_1.rx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1281sub3]
ParameterName=SDO server Node ID
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=0x7F
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_1.node_id
[1282]
SubNumber=4
ObjectType=9
ParameterName=Client SDO 3 parameters
;SEVCONFIELD OBJECT=SDO_PARAMETER
;SEVCONFIELD SECTION=ClientServerSDOs
;SEVCONFIELD CATEGORY=CONFIGURATION
[1282sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[1282sub1]
ParameterName=COB-ID Client->Server (tx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_2.tx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1282sub2]
ParameterName=COB-ID Server->Client (rx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_2.rx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1282sub3]
ParameterName=SDO server Node ID
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=0x7F
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_2.node_id
[1283]
SubNumber=4
ObjectType=9
ParameterName=Client SDO 4 parameters
;SEVCONFIELD OBJECT=SDO_PARAMETER
;SEVCONFIELD SECTION=ClientServerSDOs
;SEVCONFIELD CATEGORY=CONFIGURATION
[1283sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[1283sub1]
ParameterName=COB-ID Client->Server (tx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_3.tx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1283sub2]
ParameterName=COB-ID Server->Client (rx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_3.rx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1283sub3]
ParameterName=SDO server Node ID
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=0x7F
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_3.node_id
[1284]
SubNumber=4
ObjectType=9
ParameterName=Client SDO 5 parameters
;SEVCONFIELD OBJECT=SDO_PARAMETER
;SEVCONFIELD SECTION=ClientServerSDOs
;SEVCONFIELD CATEGORY=CONFIGURATION
[1284sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[1284sub1]
ParameterName=COB-ID Client->Server (tx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_4.tx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1284sub2]
ParameterName=COB-ID Server->Client (rx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_4.rx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1284sub3]
ParameterName=SDO server Node ID
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=0x7F
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_4.node_id
[1285]
SubNumber=4
ObjectType=9
ParameterName=Client SDO 6 parameters
;SEVCONFIELD OBJECT=SDO_PARAMETER
;SEVCONFIELD SECTION=ClientServerSDOs
;SEVCONFIELD CATEGORY=CONFIGURATION
[1285sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[1285sub1]
ParameterName=COB-ID Client->Server (tx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_5.tx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1285sub2]
ParameterName=COB-ID Server->Client (rx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_5.rx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1285sub3]
ParameterName=SDO server Node ID
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=0x7F
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_5.node_id
[1286]
SubNumber=4
ObjectType=9
ParameterName=Client SDO 7 parameters
;SEVCONFIELD OBJECT=SDO_PARAMETER
;SEVCONFIELD SECTION=ClientServerSDOs
;SEVCONFIELD CATEGORY=CONFIGURATION
[1286sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[1286sub1]
ParameterName=COB-ID Client->Server (tx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_6.tx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1286sub2]
ParameterName=COB-ID Server->Client (rx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_6.rx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1286sub3]
ParameterName=SDO server Node ID
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=0x7F
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_6.node_id
[1287]
SubNumber=4
ObjectType=9
ParameterName=Client SDO 8 parameters
;SEVCONFIELD OBJECT=SDO_PARAMETER
;SEVCONFIELD SECTION=ClientServerSDOs
;SEVCONFIELD CATEGORY=CONFIGURATION
[1287sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[1287sub1]
ParameterName=COB-ID Client->Server (tx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_7.tx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1287sub2]
ParameterName=COB-ID Server->Client (rx)
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_7.rx_sdo_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1287sub3]
ParameterName=SDO server Node ID
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=0x7F
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.csdo_7.node_id
[1400]
SubNumber=3
ObjectType=9
ParameterName=Receive PDO communication parameters 1
;SEVCONFIELD OBJECT=PDO_COMMUNICATION
;SEVCONFIELD SECTION=RECEIVEPDO1
;SEVCONFIELD CATEGORY=CONFIGURATION
[1400sub0]
ParameterName=Largest sub-index supported
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[1400sub1]
ParameterName=COB-ID used by PDO
ParameterValue=0x00000200
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0x00000001
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0x80000182
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_0.cob_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1400sub2]
ParameterName=Transmission type
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=255
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_0.trans_type
[1401]
SubNumber=3
ObjectType=9
ParameterName=Receive PDO communication parameters 2
;SEVCONFIELD OBJECT=PDO_COMMUNICATION
;SEVCONFIELD SECTION=RECEIVEPDO2
;SEVCONFIELD CATEGORY=CONFIGURATION
[1401sub0]
ParameterName=Largest sub-index supported
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[1401sub1]
ParameterName=COB-ID used by PDO
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0x00000001
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0x80000282
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_1.cob_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1401sub2]
ParameterName=Transmission type
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=255
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_1.trans_type
[1402]
SubNumber=3
ObjectType=9
ParameterName=Receive PDO communication parameters 3
;SEVCONFIELD OBJECT=PDO_COMMUNICATION
;SEVCONFIELD SECTION=RECEIVEPDO3
;SEVCONFIELD CATEGORY=CONFIGURATION
[1402sub0]
ParameterName=Largest sub-index supported
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[1402sub1]
ParameterName=COB-ID used by PDO
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0x00000001
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0x80000382
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_2.cob_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1402sub2]
ParameterName=Transmission type
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=255
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_2.trans_type
[1403]
SubNumber=3
ObjectType=9
ParameterName=Receive PDO communication parameters 4
;SEVCONFIELD OBJECT=PDO_COMMUNICATION
;SEVCONFIELD SECTION=RECEIVEPDO4
;SEVCONFIELD CATEGORY=CONFIGURATION
[1403sub0]
ParameterName=Largest sub-index supported
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[1403sub1]
ParameterName=COB-ID used by PDO
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0x00000001
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0x80000183
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_3.cob_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1403sub2]
ParameterName=Transmission type
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=255
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_3.trans_type
[1404]
SubNumber=3
ObjectType=9
ParameterName=Receive PDO communication parameters 5
;SEVCONFIELD OBJECT=PDO_COMMUNICATION
;SEVCONFIELD SECTION=RECEIVEPDO5
;SEVCONFIELD CATEGORY=CONFIGURATION
[1404sub0]
ParameterName=Largest sub-index supported
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[1404sub1]
ParameterName=COB-ID used by PDO
ParameterValue=0x80000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0x00000001
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0x80000283
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_4.cob_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1404sub2]
ParameterName=Transmission type
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=255
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_comm_4.trans_type
[1600]
SubNumber=9
ObjectType=9
ParameterName=Receive PDO mapping parameters 1
;SEVCONFIELD OBJECT=RPDO_MAPPING
;SEVCONFIELD SECTION=RECEIVEPDO1
;SEVCONFIELD CATEGORY=CONFIGURATION
[1600sub0]
ParameterName=Number of mapped objects
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.num_objects
[1600sub1]
ParameterName=Map 1
ParameterValue=0x21210001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x20210210
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[0]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1600sub2]
ParameterName=Map 2
ParameterValue=0x21220001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x20210420
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[1]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1600sub3]
ParameterName=Map 3
ParameterValue=0x21220001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x20210610
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[2]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1600sub4]
ParameterName=Map 4
ParameterValue=0x21230001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C110410
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[3]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1600sub5]
ParameterName=Map 5
ParameterValue=0x21240001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C110110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[4]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1600sub6]
ParameterName=Map 6
ParameterValue=0x21250001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C110110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[5]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1600sub7]
ParameterName=Map 7
ParameterValue=0x21240001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C110110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[6]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1600sub8]
ParameterName=Map 8
ParameterValue=0x21250001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C110110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_0.object[7]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1601]
SubNumber=9
ObjectType=9
ParameterName=Receive PDO mapping parameters 2
;SEVCONFIELD OBJECT=RPDO_MAPPING
;SEVCONFIELD SECTION=RECEIVEPDO2
;SEVCONFIELD CATEGORY=CONFIGURATION
[1601sub0]
ParameterName=Number of mapped objects
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=8
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.num_objects
[1601sub1]
ParameterName=Map 1
ParameterValue=0x21210001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x21200001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[0]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1601sub2]
ParameterName=Map 2
ParameterValue=0x21220001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x21210001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[1]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1601sub3]
ParameterName=Map 3
ParameterValue=0x21230001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x21220001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[2]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1601sub4]
ParameterName=Map 4
ParameterValue=0x21240001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x21230001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[3]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1601sub5]
ParameterName=Map 5
ParameterValue=0x21250001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x21240001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[4]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1601sub6]
ParameterName=Map 6
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x21250001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[5]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1601sub7]
ParameterName=Map 7
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x21260001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[6]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1601sub8]
ParameterName=Map 8
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x21270001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_1.object[7]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1602]
SubNumber=9
ObjectType=9
ParameterName=Receive PDO mapping parameters 3
;SEVCONFIELD OBJECT=RPDO_MAPPING
;SEVCONFIELD SECTION=RECEIVEPDO3
;SEVCONFIELD CATEGORY=CONFIGURATION
[1602sub0]
ParameterName=Number of mapped objects
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=4
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.num_objects
[1602sub1]
ParameterName=Map 1
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x22200010
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[0]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1602sub2]
ParameterName=Map 2
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x22210010
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[1]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1602sub3]
ParameterName=Map 3
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x22220010
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[2]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1602sub4]
ParameterName=Map 4
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x22230010
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[3]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1602sub5]
ParameterName=Map 5
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C110110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[4]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1602sub6]
ParameterName=Map 6
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C110110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[5]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1602sub7]
ParameterName=Map 7
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C110110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[6]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1602sub8]
ParameterName=Map 8
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C110110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_2.object[7]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1603]
SubNumber=9
ObjectType=9
ParameterName=Receive PDO mapping parameters 4
;SEVCONFIELD OBJECT=RPDO_MAPPING
;SEVCONFIELD SECTION=RECEIVEPDO4
;SEVCONFIELD CATEGORY=CONFIGURATION
[1603sub0]
ParameterName=Number of mapped objects
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.num_objects
[1603sub1]
ParameterName=Map 1
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x20400210
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[0]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1603sub2]
ParameterName=Map 2
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x20400420
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[1]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1603sub3]
ParameterName=Map 3
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x20400610
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[2]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1603sub4]
ParameterName=Map 4
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C110110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[3]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1603sub5]
ParameterName=Map 5
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C110110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[4]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1603sub6]
ParameterName=Map 6
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C110110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[5]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1603sub7]
ParameterName=Map 7
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C110110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[6]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1603sub8]
ParameterName=Map 8
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C110110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_3.object[7]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1604]
SubNumber=9
ObjectType=9
ParameterName=Receive PDO mapping parameters 5
;SEVCONFIELD OBJECT=RPDO_MAPPING
;SEVCONFIELD SECTION=RECEIVEPDO5
;SEVCONFIELD CATEGORY=CONFIGURATION
[1604sub0]
ParameterName=Number of mapped objects
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=7
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.num_objects
[1604sub1]
ParameterName=Map 1
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x21400001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[0]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1604sub2]
ParameterName=Map 2
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x21410001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[1]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1604sub3]
ParameterName=Map 3
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x21420001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[2]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1604sub4]
ParameterName=Map 4
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x21430001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[3]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1604sub5]
ParameterName=Map 5
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x21440001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[4]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1604sub6]
ParameterName=Map 6
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x21450001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[5]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1604sub7]
ParameterName=Map 7
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x21460001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[6]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1604sub8]
ParameterName=Map 8
ParameterValue=0x6c110110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C110110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.rpdo_map_4.object[7]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1800]
SubNumber=5
ObjectType=9
ParameterName=Transmit PDO communication parameters 1
;SEVCONFIELD OBJECT=PDO_COMMUNICATION
;SEVCONFIELD SECTION=TRANSMITPDO1
;SEVCONFIELD CATEGORY=CONFIGURATION
[1800sub0]
ParameterName=Largest sub-index supported
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=5
;SEVCONFIELD OBJECT_VERSION=1
[1800sub1]
ParameterName=COB-ID used by PDO
ParameterValue=0x00000310
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0x00000001
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0x80000202
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_0.cob_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1800sub2]
ParameterName=Transmission type
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_0.trans_type
[1800sub3]
ParameterName=Inhibit time
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=ms
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_0.inhibit_time
[1800sub5]
ParameterName=Event timer
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=ms
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_0.w_event_timer_reload
[1801]
SubNumber=5
ObjectType=9
ParameterName=Transmit PDO communication parameters 2
;SEVCONFIELD OBJECT=PDO_COMMUNICATION
;SEVCONFIELD SECTION=TRANSMITPDO2
;SEVCONFIELD CATEGORY=CONFIGURATION
[1801sub0]
ParameterName=Largest sub-index supported
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=5
;SEVCONFIELD OBJECT_VERSION=1
[1801sub1]
ParameterName=COB-ID used by PDO
ParameterValue=0x00000259
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0x00000001
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0x80000302
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_1.cob_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1801sub2]
ParameterName=Transmission type
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0xFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_1.trans_type
[1801sub3]
ParameterName=Inhibit time
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=ms
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_1.inhibit_time
[1801sub5]
ParameterName=Event timer
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=ms
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_1.w_event_timer_reload
[1802]
SubNumber=5
ObjectType=9
ParameterName=Transmit PDO communication parameters 3
;SEVCONFIELD OBJECT=PDO_COMMUNICATION
;SEVCONFIELD SECTION=TRANSMITPDO3
;SEVCONFIELD CATEGORY=CONFIGURATION
[1802sub0]
ParameterName=Largest sub-index supported
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=5
;SEVCONFIELD OBJECT_VERSION=1
[1802sub1]
ParameterName=COB-ID used by PDO
ParameterValue=0x00000132
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0x00000001
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0x80000402
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_2.cob_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1802sub2]
ParameterName=Transmission type
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0xFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_2.trans_type
[1802sub3]
ParameterName=Inhibit time
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=ms
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_2.inhibit_time
[1802sub5]
ParameterName=Event timer
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=ms
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_2.w_event_timer_reload
[1803]
SubNumber=5
ObjectType=9
ParameterName=Transmit PDO communication parameters 4
;SEVCONFIELD OBJECT=PDO_COMMUNICATION
;SEVCONFIELD SECTION=TRANSMITPDO4
;SEVCONFIELD CATEGORY=CONFIGURATION
[1803sub0]
ParameterName=Largest sub-index supported
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=5
;SEVCONFIELD OBJECT_VERSION=1
[1803sub1]
ParameterName=COB-ID used by PDO
ParameterValue=0x00000477
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0x00000001
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0x80000203
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_3.cob_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1803sub2]
ParameterName=Transmission type
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_3.trans_type
[1803sub3]
ParameterName=Inhibit time
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=ms
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_3.inhibit_time
[1803sub5]
ParameterName=Event timer
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=ms
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_3.w_event_timer_reload
[1804]
SubNumber=5
ObjectType=9
ParameterName=Transmit PDO communication parameters 5
;SEVCONFIELD OBJECT=PDO_COMMUNICATION
;SEVCONFIELD SECTION=TRANSMITPDO5
;SEVCONFIELD CATEGORY=CONFIGURATION
[1804sub0]
ParameterName=Largest sub-index supported
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=5
;SEVCONFIELD OBJECT_VERSION=1
[1804sub1]
ParameterName=COB-ID used by PDO
ParameterValue=0x00000140
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0x00000001
HighLimit=0x9FFFFFFF
PDOMapping=0
DefaultValue=0x80000303
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_4.cob_id
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1804sub2]
ParameterName=Transmission type
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0xFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_4.trans_type
[1804sub3]
ParameterName=Inhibit time
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=ms
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_4.inhibit_time
[1804sub5]
ParameterName=Event timer
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=ms
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_comm_4.w_event_timer_reload
[1A00]
SubNumber=9
ObjectType=9
ParameterName=Transmit PDO mapping parameters 1
;SEVCONFIELD OBJECT=TPDO_MAPPING
;SEVCONFIELD SECTION=TRANSMITPDO1
;SEVCONFIELD CATEGORY=CONFIGURATION
[1A00sub0]
ParameterName=Number of mapped objects
ParameterValue=0x04
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.num_objects
[1A00sub1]
ParameterName=Map 1
ParameterValue=0x46000510
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x20210110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[0]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A00sub2]
ParameterName=Map 2
ParameterValue=0x46000610
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x20210320
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[1]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A00sub3]
ParameterName=Map 3
ParameterValue=0x46000710
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x20210510
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[2]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A00sub4]
ParameterName=Map 4
ParameterValue=0x46000810
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[3]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A00sub5]
ParameterName=Map 5
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[4]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A00sub6]
ParameterName=Map 6
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[5]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A00sub7]
ParameterName=Map 7
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[6]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A00sub8]
ParameterName=Map 8
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_0.object[7]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A01]
SubNumber=9
ObjectType=9
ParameterName=Transmit PDO mapping parameters 2
;SEVCONFIELD OBJECT=TPDO_MAPPING
;SEVCONFIELD SECTION=TRANSMITPDO2
;SEVCONFIELD CATEGORY=CONFIGURATION
[1A01sub0]
ParameterName=Number of mapped objects
ParameterValue=0x04
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.num_objects
[1A01sub1]
ParameterName=Map 1
ParameterValue=0x46000910
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x23200001
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[0]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A01sub2]
ParameterName=Map 2
ParameterValue=0x46000a10
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C010210
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[1]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A01sub3]
ParameterName=Map 3
ParameterValue=0x46000b10
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C010310
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[2]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A01sub4]
ParameterName=Map 4
ParameterValue=0x60780010
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x6C010410
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[3]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A01sub5]
ParameterName=Map 5
ParameterValue=0x60410010
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[4]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A01sub6]
ParameterName=Map 6
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[5]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A01sub7]
ParameterName=Map 7
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[6]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A01sub8]
ParameterName=Map 8
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_1.object[7]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A02]
SubNumber=9
ObjectType=9
ParameterName=Transmit PDO mapping parameters 3
;SEVCONFIELD OBJECT=TPDO_MAPPING
;SEVCONFIELD SECTION=TRANSMITPDO3
;SEVCONFIELD CATEGORY=CONFIGURATION
[1A02sub0]
ParameterName=Number of mapped objects
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=4
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.num_objects
[1A02sub1]
ParameterName=Map 1
ParameterValue=0x51000310
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x24000010
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[0]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A02sub2]
ParameterName=Map 2
ParameterValue=0x51000408
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x24010010
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[1]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A02sub3]
ParameterName=Map 3
ParameterValue=0x51000210
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x24200010
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[2]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A02sub4]
ParameterName=Map 4
ParameterValue=0x60710010
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x24210010
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[3]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A02sub5]
ParameterName=Map 5
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[4]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A02sub6]
ParameterName=Map 6
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[5]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A02sub7]
ParameterName=Map 7
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[6]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A02sub8]
ParameterName=Map 8
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_2.object[7]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A03]
SubNumber=9
ObjectType=9
ParameterName=Transmit PDO mapping parameters 4
;SEVCONFIELD OBJECT=TPDO_MAPPING
;SEVCONFIELD SECTION=TRANSMITPDO4
;SEVCONFIELD CATEGORY=CONFIGURATION
[1A03sub0]
ParameterName=Number of mapped objects
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.num_objects
[1A03sub1]
ParameterName=Map 1
ParameterValue=0x20200320
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x20400110
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[0]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A03sub2]
ParameterName=Map 2
ParameterValue=0x606c0020
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x20400320
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[1]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A03sub3]
ParameterName=Map 3
ParameterValue=0x46000610
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x20400510
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[2]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A03sub4]
ParameterName=Map 4
ParameterValue=0x46000710
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[3]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A03sub5]
ParameterName=Map 5
ParameterValue=0x27200208
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[4]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A03sub6]
ParameterName=Map 6
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[5]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A03sub7]
ParameterName=Map 7
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[6]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A03sub8]
ParameterName=Map 8
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_3.object[7]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A04]
SubNumber=9
ObjectType=9
ParameterName=Transmit PDO mapping parameters 5
;SEVCONFIELD OBJECT=TPDO_MAPPING
;SEVCONFIELD SECTION=TRANSMITPDO5
;SEVCONFIELD CATEGORY=CONFIGURATION
[1A04sub0]
ParameterName=Number of mapped objects
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.num_objects
[1A04sub1]
ParameterName=Map 1
ParameterValue=0x46000110
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[0]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A04sub2]
ParameterName=Map 2
ParameterValue=0x60770010
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[1]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A04sub3]
ParameterName=Map 3
ParameterValue=0x26200010
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[2]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A04sub4]
ParameterName=Map 4
ParameterValue=0x21210001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[3]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A04sub5]
ParameterName=Map 5
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[4]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A04sub6]
ParameterName=Map 6
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[5]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A04sub7]
ParameterName=Map 7
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[6]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[1A04sub8]
ParameterName=Map 8
ParameterValue=0x68000108
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x68000108
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=sdo_pdo.tpdo_map_4.object[7]
;SEVCONFIELD NUMBER_FORMAT=BASE16
[6040]
ParameterName=controlword
ParameterValue=0x8007
ObjectType=7
DataType=6
AccessType=rww
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=CONTROLWORD
;SEVCONFIELD SECTION=MOTOR1CONTROL
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD CATEGORY=MONITORING
[6041]
ParameterName=statusword
ParameterValue=0x0840
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=STATUSWORD
;SEVCONFIELD SECTION=Motor1Status
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD CATEGORY=MONITORING
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=7
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Device status
;SEVCONFIELD BITMASK=0x6F
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=0x6F
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0x20=not ready to switch on
;SEVCONFIELD 0x0=not ready to switch on
;SEVCONFIELD 0x40=switch on disabled
;SEVCONFIELD 0x60=switch on disabled
;SEVCONFIELD 0x21=ready to switch on
;SEVCONFIELD 0x31=ready to switch on
;SEVCONFIELD 0x23=switched on
;SEVCONFIELD 0x33=switched on
;SEVCONFIELD 0x27=Operation enabled
;SEVCONFIELD 0x37=Operation enabled
;SEVCONFIELD 0x7=Quick stop active
;SEVCONFIELD 0x17=Quick stop active
;SEVCONFIELD 0xF= Fault reaction active
;SEVCONFIELD 0x2F=Fault reaction active
;SEVCONFIELD 0x8=Fault
;SEVCONFIELD 0x28=Fault
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Voltage enabled
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=disabled
;SEVCONFIELD 1=enabled
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Warning
;SEVCONFIELD BITMASK=0x80
;SEVCONFIELD BITSHIFT=0x7
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=cleared
;SEVCONFIELD 1=set
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Remote
;SEVCONFIELD BITMASK=0x200
;SEVCONFIELD BITSHIFT=0x9
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=disabled
;SEVCONFIELD 1=enabled
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=Target reached
;SEVCONFIELD BITMASK=0x400
;SEVCONFIELD BITSHIFT=0xA
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=not reached
;SEVCONFIELD 1=reached
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Internal limit active
;SEVCONFIELD BITMASK=0x800
;SEVCONFIELD BITSHIFT=0xB
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=cleared
;SEVCONFIELD 1=active
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=Operation mode specific
;SEVCONFIELD BITMASK=0x3000
;SEVCONFIELD BITSHIFT=0xC
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD
[6060]
ParameterName=Mode of operation selection
ParameterValue=0x04
ObjectType=7
DataType=2
AccessType=rw
LowLimit=3
HighLimit=4
PDOMapping=0
DefaultValue=4
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=MODE_OF_OPERATION
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD EEPROM=motor_0.mode
;SEVCONFIELD NUMBER_FORMAT=3
;SEVCONFIELD 3=speed
;SEVCONFIELD 4=torque
;SEVCONFIELD 5=voltage
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[6061]
ParameterName=Operational mode
ParameterValue=0x04
ObjectType=7
DataType=2
AccessType=ro
LowLimit=3
HighLimit=4
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=MODE_OF_OPERATION_DISPLAY
;SEVCONFIELD SECTION=Motor1Status
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 3=speed
;SEVCONFIELD 4=torque
;SEVCONFIELD CATEGORY=MONITORING
[6069]
ParameterName=Encoder count
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=ro
LowLimit=-400000
HighLimit=400000
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=Inc/s
;SEVCONFIELD OBJECT=VELOCITY_SENSOR_ACTUAL
;SEVCONFIELD SECTION=Motor1Status
;SEVCONFIELD CATEGORY=MONITORING
[606B]
ParameterName=Velocity demand
ParameterValue=0x0000003d
ObjectType=7
DataType=4
AccessType=ro
LowLimit=-20000
HighLimit=20000
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD OBJECT=VELOCITY_DEMAND
;SEVCONFIELD SECTION=Motor1Status
;SEVCONFIELD CATEGORY=MONITORING
[606C]
ParameterName=Velocity
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=ro
LowLimit=-20000
HighLimit=20000
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD OBJECT=VELOCITY_ACTUAL
;SEVCONFIELD SECTION=Motor1Status
;SEVCONFIELD CATEGORY=MONITORING
[6071]
ParameterName=Target torque
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-1000
HighLimit=1000
PDOMapping=1
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=% of peak
;SEVCONFIELD OBJECT=TARGET_TORQUE
;SEVCONFIELD SECTION=MOTOR1CONTROL
;SEVCONFIELD SOFT_LOW=-32768
;SEVCONFIELD SOFT_HIGH=32767
;SEVCONFIELD CATEGORY=MONITORING
[6072]
ParameterName=Maximum torque
ParameterValue=0x03e8
ObjectType=7
DataType=6
AccessType=rww
LowLimit=0
HighLimit=1000
PDOMapping=1
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=% of peak
;SEVCONFIELD OBJECT=MAX_TORQUE
;SEVCONFIELD SECTION=MOTOR1CONTROL
;SEVCONFIELD EEPROM=motor_0.maximum_torque
;SEVCONFIELD CATEGORY=CONFIGURATION
[6074]
ParameterName=Torque demand
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-1000
HighLimit=1000
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=% of peak
;SEVCONFIELD OBJECT=TORQUE_DEMAND
;SEVCONFIELD SECTION=Motor1Status
;SEVCONFIELD CATEGORY=MONITORING
[6075]
ParameterName=Current limit
ParameterValue=0x00086470
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=700000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.001
;SEVCONFIELD UNITS=A(RMS)
;SEVCONFIELD OBJECT=MOTOR_RATED_TORQUE
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD EEPROM=motor_0.rated_current
;SEVCONFIELD CATEGORY=CONFIGURATION
[6076]
ParameterName=Peak torque
ParameterValue=0x00014ff0
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=2000000
PDOMapping=0
DefaultValue=25000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.001
;SEVCONFIELD UNITS=Nm
;SEVCONFIELD OBJECT=MOTOR_RATED_TORQUE
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD EEPROM=motor_0.rated_torque
;SEVCONFIELD CATEGORY=CONFIGURATION
[6077]
ParameterName=Torque
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-1000
HighLimit=1000
PDOMapping=1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=% of peak
;SEVCONFIELD OBJECT=TORQUE_ACTUAL
;SEVCONFIELD SECTION=Motor1Status
;SEVCONFIELD CATEGORY=MONITORING
[6078]
ParameterName=Current
ParameterValue=0x0001
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-1000
HighLimit=1000
PDOMapping=1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=A(RMS)
;SEVCONFIELD OBJECT=TORQUE_ACTUAL
;SEVCONFIELD SECTION=Motor1Status
;SEVCONFIELD CATEGORY=MONITORING
[6079]
ParameterName=Capacitor Voltage
ParameterValue=0x000000ac
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=400000
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.001
;SEVCONFIELD UNITS=V
;SEVCONFIELD OBJECT=DC_LINK_V
;SEVCONFIELD SECTION=Motor1Status
;SEVCONFIELD CATEGORY=MONITORING
[607E]
ParameterName=Encoder Polarity
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=64
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=ENCODER_POLARITY
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD EEPROM=motor_0.encoder_polarity
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=normal
;SEVCONFIELD 64=inverted
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[6080]
ParameterName=Maximum motor speed
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=1
DefaultValue=2500
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD OBJECT=MAX_MOTOR_SPEED
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD EEPROM=motor_0.maximum_motor_speed
;SEVCONFIELD CATEGORY=CONFIGURATION
[6083]
ParameterName=Maximum acceleration rate
ParameterValue=0x000003e8
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0x7FFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=rpm/s
;SEVCONFIELD OBJECT=PROFILE_ACCELERATION
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD EEPROM=motor_0.profile_accel
;SEVCONFIELD CATEGORY=CONFIGURATION
[6086]
ParameterName=Motion profile type
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=0
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=MOTION_PROFILE_TYPE
;SEVCONFIELD SECTION=MOTOR1STATUS
;SEVCONFIELD NUMBER_FORMAT=1
;SEVCONFIELD 0=Linear
;SEVCONFIELD CATEGORY=CONFIGURATION
[6087]
ParameterName=Torque slope
ParameterValue=0x0000ffff
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=65535
PDOMapping=0
DefaultValue=40000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=% rated/s
;SEVCONFIELD OBJECT=TORQUE_SLOPE
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD EEPROM=motor_0.trq_slope
;SEVCONFIELD CATEGORY=CONFIGURATION
[6088]
ParameterName=Torque profile type
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=0
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=TORQUE_PROFILE_TYPE
;SEVCONFIELD SECTION=MOTOR1STATUS
;SEVCONFIELD NUMBER_FORMAT=1
;SEVCONFIELD 0=Linear
;SEVCONFIELD CATEGORY=MONITORING
[608B]
ParameterName=Velocity notation index
ParameterValue=0x00
ObjectType=7
DataType=2
AccessType=ro
LowLimit=-128
HighLimit=127
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=VELOCITY_NOTATION_INDEX
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD CATEGORY=MONITORING
[608C]
ParameterName=Velocity dimension index
ParameterValue=0xa4
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0xA4
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=VELOCITY_DIMENSION_INDEX
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD CATEGORY=MONITORING
[608D]
ParameterName=Acceleration notation index
ParameterValue=0x00
ObjectType=7
DataType=2
AccessType=ro
LowLimit=-128
HighLimit=127
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=ACCELERATION_NOTATION_INDEX
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD CATEGORY=MONITORING
[608E]
ParameterName=Acceleration dimension index
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=ACCELERATION_DIMENSION_INDEX
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD CATEGORY=MONITORING
[6090]
SubNumber=3
ObjectType=9
ParameterName=Encoder resolution
;SEVCONFIELD OBJECT=ENCODER_RESOLUTION
;SEVCONFIELD SECTION=ENCODERCONFIG
;SEVCONFIELD CATEGORY=CONFIGURATION
[6090sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[6090sub1]
ParameterName=Pulses per revolution
ParameterValue=0x00000050
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=4294967295
PDOMapping=0
DefaultValue=64
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=PPR
;SEVCONFIELD EEPROM=motor_0.encoder_incs_per_second
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[6090sub2]
ParameterName=Motor revolutions per second
ParameterValue=0x00000001
ObjectType=7
DataType=7
AccessType=rw
LowLimit=1
HighLimit=4294967295
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPS
;SEVCONFIELD EEPROM=motor_0.encoder_revs_per_second
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[6095]
SubNumber=3
ObjectType=9
ParameterName=Velocity factor 1
;SEVCONFIELD OBJECT=VELOCITY_FACTOR1
;SEVCONFIELD SECTION=MOTOR1STATUS
;SEVCONFIELD CATEGORY=MONITORING
[6095sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[6095sub1]
ParameterName=Numerator
ParameterValue=0x00000001
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=100
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[6095sub2]
ParameterName=Denominator
ParameterValue=0x00000001
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=100
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[6096]
SubNumber=3
ObjectType=9
ParameterName=Velocity factor 2
;SEVCONFIELD OBJECT=VELOCITY_FACTOR2
;SEVCONFIELD SECTION=MOTOR1STATUS
;SEVCONFIELD CATEGORY=MONITORING
[6096sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[6096sub1]
ParameterName=Numerator
ParameterValue=0x00000001
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=100
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[6096sub2]
ParameterName=Denominator
ParameterValue=0x00000001
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=100
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[60F8]
ParameterName=Maximum Motor Slippage
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=rw
LowLimit=-804248
HighLimit=804248
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=6.21698996452716E-04
;SEVCONFIELD UNITS=rads/s
;SEVCONFIELD OBJECT=MAX_SLIPPAGE
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD EEPROM=motor_0.max_slippage
;SEVCONFIELD SOFT_HIGH=2147483647
;SEVCONFIELD SOFT_LOW=-2147483648
;SEVCONFIELD CATEGORY=CONFIGURATION
[60FF]
ParameterName=Target speed
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=rww
LowLimit=-20000
HighLimit=20000
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=rpm
;SEVCONFIELD OBJECT=TARGET_VELOCITY
;SEVCONFIELD SECTION=MOTOR1CONTROL
;SEVCONFIELD SOFT_HIGH=2147483647
;SEVCONFIELD SOFT_LOW=-2147483648
;SEVCONFIELD CATEGORY=MONITORING
[6502]
ParameterName=Supported drive modes
ParameterValue=0x0000000c
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x0000000C
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=SUPPORTED_DRIVE_MODES
;SEVCONFIELD SECTION=MOTOR1STATUS
;SEVCONFIELD CATEGORY=MONITORING
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=2
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Drive modes- Torque
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=not supported
;SEVCONFIELD 1=supported
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Drive modes- Speed
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=not supported
;SEVCONFIELD 1=supported
[67FF]
ParameterName=Device type
ParameterValue=0x00010192
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x00010192
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DEVICE_TYPE
;SEVCONFIELD SECTION=CANOPEN_PROFILEEND
;SEVCONFIELD CATEGORY=MONITORING
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=2
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Type
;SEVCONFIELD BITMASK=0xFFFF
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=0xFFFF
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 402=Electric Drive
;SEVCONFIELD 401=Generic I/O
;SEVCONFIELD 419=Battery charger
;SEVCONFIELD 418=Battery module
;SEVCONFIELD 410 = inclinometer
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Additional data
;SEVCONFIELD BITMASK=0xFFFF0000
;SEVCONFIELD BITSHIFT=0x10
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=0xFFFF
;SEVCONFIELD NUMBERFORMAT=BASE16
[6800]
SubNumber=3
ObjectType=9
ParameterName=Digital Input states
;SEVCONFIELD OBJECT=READ_DIG_IN_8
;SEVCONFIELD SECTION=DIStatus
;SEVCONFIELD CATEGORY=MONITORING
[6800sub0]
ParameterName=Number of digital input bytes
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[6800sub1]
ParameterName=Digital Inputs 1..8 states
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[6800sub2]
ParameterName=Digital Inputs 9..16 states
ParameterValue=0x1e
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[6802]
SubNumber=3
ObjectType=9
ParameterName=Digital Input Polarity (if set, input is active when switch is open (i.e. Normally closed))
;SEVCONFIELD OBJECT=DIG_IN_POLARITY
;SEVCONFIELD SECTION=DIConfiguration
;SEVCONFIELD CATEGORY=CONFIGURATION
[6802sub0]
ParameterName=Number of digital input bytes
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[6802sub1]
ParameterName=Digital Inputs 1..8 normally open/closed (set 1 for normally closed)
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=io.lcl_di_polarity_0
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=8
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Digital Input 1 Polarity
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Digital Input 2 Polarity
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Digital Input 3 Polarity
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Digital Input 4 Polarity
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=Digital Input 5 Polarity
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Digital Input 6 Polarity
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=Digital Input 7 Polarity
;SEVCONFIELD BITMASK=0x40
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
;SEVCONFIELD SPLIT=7
;SEVCONFIELD PARAMETERNAME=Digital Input 8 Polarity
;SEVCONFIELD BITMASK=0x80
;SEVCONFIELD BITSHIFT=0x7
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
[6802sub2]
ParameterName=Digital Inputs 9..15 normally open/closed (set 1 for normally closed)
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=io.lcl_di_polarity_1
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=8
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Digital Input 9 Polarity
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Digital Input 10 Polarity
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Digital Input 11 Polarity
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Digital Input 12 Polarity
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=Digital Input 13 Polarity
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Digital Input 14 Polarity
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=Digital Input 15 Polarity
;SEVCONFIELD BITMASK=0x40
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
;SEVCONFIELD SPLIT=7
;SEVCONFIELD PARAMETERNAME=Digital Input 16 Polarity
;SEVCONFIELD BITMASK=0x80
;SEVCONFIELD BITSHIFT=0x7
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Normally Open
;SEVCONFIELD 1=Normally Closed
[6C01]
SubNumber=6
ObjectType=9
ParameterName=Analog input values.
;SEVCONFIELD OBJECT=READ_ALG_IN_16_BIT
;SEVCONFIELD SECTION=AIStatus
;SEVCONFIELD CATEGORY=MONITORING
[6C01sub0]
ParameterName=Number of analog inputs
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=8
;SEVCONFIELD OBJECT_VERSION=1
[6C01sub1]
ParameterName=Analog input 1 voltage
ParameterValue=0x0003
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
[6C01sub2]
ParameterName=Analog input 2 voltage
ParameterValue=0x0019
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
[6C01sub3]
ParameterName=Analog input 3 voltage
ParameterValue=0x02b1
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
[6C01sub4]
ParameterName=Analog input 4 voltage
ParameterValue=0x0cbe
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
[6C01sub5]
ParameterName=Analog input 5 voltage
ParameterValue=0x0c86
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
[6C11]
SubNumber=4
ObjectType=9
ParameterName=Analog output (contactor drive) values.
;SEVCONFIELD OBJECT=WRITE_ALG_OUT_16_BIT
;SEVCONFIELD SECTION=AOStatus
;SEVCONFIELD CATEGORY=MONITORING
[6C11sub0]
ParameterName=Number of analog outputs
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=7
;SEVCONFIELD OBJECT_VERSION=1
[6C11sub1]
ParameterName=Analog output 1 value (in amps or volts depending on current / voltage mode (46A1h)).
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V_or_A
[6C11sub2]
ParameterName=Analog output 2 value (in amps or volts depending on current / voltage mode (46A1h)).
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V_or_A
[6C11sub3]
ParameterName=Analog output 3 value (in amps or volts depending on current / voltage mode (46A1h)).
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V_or_A
[6C43]
SubNumber=4
ObjectType=9
ParameterName=Analog output (contactor drive) error modes
;SEVCONFIELD OBJECT=ALG_OUT_ERROR_MODE
;SEVCONFIELD SECTION=AOConfiguration
;SEVCONFIELD CATEGORY=CONFIGURATION
[6C43sub0]
ParameterName=Number of analog outputs
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=7
;SEVCONFIELD OBJECT_VERSION=1
[6C43sub1]
ParameterName=Analog output 1 error mode (output goes to value in 6C44h if CAN communication is lost)
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0x1
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=io.lcl_ao_error_mode_0
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[6C43sub2]
ParameterName=Analog output 2 error mode (output goes to value in 6C44h if CAN communication is lost)
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0x1
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=io.lcl_ao_error_mode_1
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[6C43sub3]
ParameterName=Analog output 3 error mode (output goes to value in 6C44h if CAN communication is lost)
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0x1
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=io.lcl_ao_error_mode_2
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[6C44]
SubNumber=4
ObjectType=9
ParameterName=Analog output error value
;SEVCONFIELD OBJECT=ALG_OUT_ERROR_VALUE
;SEVCONFIELD SECTION=AOConfiguration
;SEVCONFIELD CATEGORY=CONFIGURATION
[6C44sub0]
ParameterName=Number of analog outputs
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=7
;SEVCONFIELD OBJECT_VERSION=1
[6C44sub1]
ParameterName=Analog output 1 error value (analog output goes to this value if enabled in 6C43h when CAN communication is lost)
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=rw
LowLimit=-2147483648
HighLimit=2147483647
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=5.96046447753906E-08
;SEVCONFIELD UNITS=V_or_A
;SEVCONFIELD EEPROM=io.lcl_ao_error_value_0
[6C44sub2]
ParameterName=Analog output 2 error value (analog output goes to this value if enabled in 6C43h when CAN communication is lost)
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=rw
LowLimit=-2147483648
HighLimit=2147483647
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=5.96046447753906E-08
;SEVCONFIELD UNITS=V_or_A
;SEVCONFIELD EEPROM=io.lcl_ao_error_value_1
[6C44sub3]
ParameterName=Analog output 3 error value (analog output goes to this value if enabled in 6C43h when CAN communication is lost)
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=rw
LowLimit=-2147483648
HighLimit=2147483647
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=5.96046447753906E-08
;SEVCONFIELD UNITS=V_or_A
;SEVCONFIELD EEPROM=io.lcl_ao_error_value_2
[6FFF]
ParameterName=Device Type
ParameterValue=0x000f0191
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
DefaultValue=0x000F0191
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DEVICE_TYPE
;SEVCONFIELD SECTION=CANOPEN_PROFILEEND
;SEVCONFIELD CATEGORY=MONITORING
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=2
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Type
;SEVCONFIELD BITMASK=0xFFFF
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=0xFFFF
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 402=Electric Drive
;SEVCONFIELD 401=Generic I/O
;SEVCONFIELD 419=Battery charger
;SEVCONFIELD 418=Battery module
;SEVCONFIELD 410 = inclinometer
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Additional data
;SEVCONFIELD BITMASK=0xFFFF0000
;SEVCONFIELD BITSHIFT=0x10
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=0xFFFF
;SEVCONFIELD NUMBERFORMAT=BASE16
[ManufacturerObjects]
SupportedObjects=240
1=0x2020
2=0x2021
3=0x2040
4=0x2060
5=0x2100
6=0x2101
7=0x2120
8=0x2121
9=0x2122
10=0x2123
11=0x2124
12=0x2125
13=0x2126
14=0x2127
15=0x2129
16=0x212A
17=0x212B
18=0x212C
19=0x212D
20=0x212E
21=0x212F
22=0x2130
23=0x2131
24=0x2139
25=0x213A
26=0x2140
27=0x2141
28=0x2142
29=0x2143
30=0x2144
31=0x2145
32=0x2146
33=0x2150
34=0x2152
35=0x2153
36=0x2160
37=0x217D
38=0x217F
39=0x2220
40=0x2221
41=0x2222
42=0x2223
43=0x2224
44=0x2240
45=0x2241
46=0x2320
47=0x2400
48=0x2401
49=0x2402
50=0x2403
51=0x2404
52=0x2405
53=0x2420
54=0x2421
55=0x2422
56=0x2423
57=0x2440
58=0x2460
59=0x2620
60=0x2621
61=0x2622
62=0x2623
63=0x2624
64=0x2626
65=0x2640
66=0x2641
67=0x2720
68=0x2721
69=0x2722
70=0x2723
71=0x2740
72=0x2760
73=0x2781
74=0x2782
75=0x2783
76=0x2784
77=0x2785
78=0x2786
79=0x278F
80=0x2790
81=0x2800
82=0x2810
83=0x2820
84=0x2830
85=0x2840
86=0x2850
87=0x2870
88=0x2871
89=0x2872
90=0x2900
91=0x2901
92=0x2902
93=0x2903
94=0x2904
95=0x2906
96=0x2907
97=0x2908
98=0x2909
99=0x290A
100=0x290B
101=0x290C
102=0x290D
103=0x290E
104=0x2910
105=0x2911
106=0x2912
107=0x2913
108=0x2914
109=0x2915
110=0x2916
111=0x2918
112=0x2919
113=0x291A
114=0x291C
115=0x291E
116=0x291F
117=0x2920
118=0x2921
119=0x2922
120=0x2928
121=0x2930
122=0x2931
123=0x2933
124=0x29A0
125=0x29A1
126=0x2A00
127=0x2A01
128=0x2A10
129=0x2A11
130=0x2A20
131=0x2A21
132=0x2A22
133=0x2A23
134=0x2A24
135=0x2A25
136=0x2A26
137=0x2A30
138=0x2A31
139=0x2B00
140=0x2B01
141=0x2B02
142=0x2C00
143=0x2C01
144=0x2C02
145=0x2C03
146=0x2C30
147=0x2C31
148=0x2D00
149=0x2D01
150=0x2D02
151=0x2E00
152=0x3000
153=0x3200
154=0x3300
155=0x3400
156=0x4000
157=0x4100
158=0x4101
159=0x4102
160=0x4110
161=0x4111
162=0x4112
163=0x4200
164=0x4201
165=0x4202
166=0x4203
167=0x4204
168=0x4205
169=0x4206
170=0x4207
171=0x4208
172=0x4209
173=0x420A
174=0x4300
175=0x4301
176=0x4600
177=0x4601
178=0x4602
179=0x4603
180=0x4610
181=0x4611
182=0x4612
183=0x4614
184=0x4620
185=0x4621
186=0x4623
187=0x4624
188=0x4630
189=0x4640
190=0x4641
191=0x4650
192=0x4651
193=0x4653
194=0x4654
195=0x4680
196=0x4681
197=0x4690
198=0x46A1
199=0x46A2
200=0x46A3
201=0x46C0
202=0x46C1
203=0x46C2
204=0x46C3
205=0x46C4
206=0x46D0
207=0x5000
208=0x5001
209=0x5100
210=0x5110
211=0x5180
212=0x5200
213=0x5300
214=0x5310
215=0x5320
216=0x5400
217=0x5500
218=0x5501
219=0x5502
220=0x5600
221=0x5601
222=0x5602
223=0x5603
224=0x5604
225=0x5605
226=0x5610
227=0x5620
228=0x5621
229=0x5630
230=0x5631
231=0x5800
232=0x5810
233=0x5811
234=0x5820
235=0x5821
236=0x5830
237=0x5900
238=0x5901
239=0x5902
240=0x5A01
[2020]
SubNumber=7
ObjectType=9
ParameterName=Motor drive left information
;SEVCONFIELD OBJECT=MOTOR_DRIVE
;SEVCONFIELD SECTION=TractionStatus
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2020sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[2020sub1]
ParameterName=controlword - left motor
ParameterValue=0x8000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[2020sub2]
ParameterName=statusword - left motor
ParameterValue=0x0833
ObjectType=7
DataType=6
AccessType=rww
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[2020sub3]
ParameterName=Target velocity - left motor
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=ro
LowLimit=-2147483648
HighLimit=2147483647
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=RPM
[2020sub4]
ParameterName=Velocity actual value - left motor
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=rww
LowLimit=-2147483648
HighLimit=2147483647
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=RPM
[2020sub5]
ParameterName=Max torque - left motor
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.001
[2020sub6]
ParameterName=Actual torque - left motor
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.001
[2021]
SubNumber=7
ObjectType=9
ParameterName=Motor drive right information
;SEVCONFIELD OBJECT=MOTOR_DRIVE
;SEVCONFIELD SECTION=TractionStatus
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2021sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[2021sub1]
ParameterName=controlword - right motor
ParameterValue=0x8000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[2021sub2]
ParameterName=statusword - right motor
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rww
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[2021sub3]
ParameterName=Target velocity - right motor
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=ro
LowLimit=-2147483648
HighLimit=2147483647
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=RPM
[2021sub4]
ParameterName=Velocity actual value - right motor
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=rww
LowLimit=-2147483648
HighLimit=2147483647
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=RPM
[2021sub5]
ParameterName=Max torque - right motor
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.001
[2021sub6]
ParameterName=Actual torque - right motor
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.001
[2040]
SubNumber=7
ObjectType=9
ParameterName=Motor drive pump information
;SEVCONFIELD OBJECT=MOTOR_DRIVE
;SEVCONFIELD SECTION=PumpStatus
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2040sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[2040sub1]
ParameterName=controlword - pump motor
ParameterValue=0xc000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[2040sub2]
ParameterName=statusword - pump motor
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rww
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[2040sub3]
ParameterName=Target velocity - pump motor
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=ro
LowLimit=-2147483648
HighLimit=2147483647
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=RPM
[2040sub4]
ParameterName=Velocity actual value - pump motor
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=rww
LowLimit=-2147483648
HighLimit=2147483647
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=RPM
[2040sub5]
ParameterName=Max torque - pump motor
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.001
[2040sub6]
ParameterName=Actual torque - pump motor
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.001
[2060]
SubNumber=7
ObjectType=9
ParameterName=Motor drive power steer information
;SEVCONFIELD OBJECT=MOTOR_DRIVE
;SEVCONFIELD SECTION=PSteerStatus
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2060sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[2060sub1]
ParameterName=controlword - power steer motor
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[2060sub2]
ParameterName=statusword - power steer motor
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rww
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[2060sub3]
ParameterName=Target velocity - power steer motor
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=ro
LowLimit=-2147483648
HighLimit=2147483647
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=RPM
[2060sub4]
ParameterName=Velocity actual value - power steer motor
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=rww
LowLimit=-2147483648
HighLimit=2147483647
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=RPM
[2060sub5]
ParameterName=Max torque - power steer motor
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.001
[2060sub6]
ParameterName=Actual torque - power steer motor
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.001
[2100]
ParameterName=Key switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=VehicleDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2101]
ParameterName=Horn switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=VehicleDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2120]
ParameterName=Drive enable switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2121]
ParameterName=Forward Switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2122]
ParameterName=Reverse Switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2123]
ParameterName=FS1 switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2124]
ParameterName=Seat switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2125]
ParameterName=Handbrake switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2126]
ParameterName=Driveability Select 1 switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2127]
ParameterName=Driveability Select 2 switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2129]
ParameterName=Inch forward switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[212A]
ParameterName=Inch reverse switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[212B]
ParameterName=Inner left steer switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[212C]
ParameterName=Outer left steer switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[212D]
ParameterName=Inner right steer switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[212E]
ParameterName=Outer right steer switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[212F]
ParameterName=High speed switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2130]
ParameterName=Footbrake switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2131]
ParameterName=Regen Charging Enable Switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2139]
ParameterName=Belly
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[213A]
ParameterName=Deadman switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2140]
ParameterName=Pump 1 switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=PumpDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2141]
ParameterName=Pump 2 switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=PumpDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2142]
ParameterName=Pump 3 switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=PumpDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2143]
ParameterName=Pump 4 switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=PumpDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2144]
ParameterName=Pump 5 switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=PumpDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2145]
ParameterName=Pump 6 switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=PumpDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2146]
ParameterName=Pump 7 switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=PumpDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2150]
ParameterName=Pump Inhibit switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=PumpDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2152]
ParameterName=Pump Driveability 1 switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=PumpDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2153]
ParameterName=Pump Driveability 2 switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=PumpDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2160]
ParameterName=Power steer trigger switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=PSteerDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[217D]
ParameterName=Trip Distance Reset
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 1=Inactive
;SEVCONFIELD 0=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[217F]
ParameterName=Slave Left Motor Invert Switch
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rww
LowLimit=0
HighLimit=1
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_IN
;SEVCONFIELD SECTION=TractionDI
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2220]
ParameterName=Throttle Input Voltage
ParameterValue=0x0003
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_IN
;SEVCONFIELD SECTION=TractionAI
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2221]
ParameterName=Footbrake Pot Input Voltage
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_IN
;SEVCONFIELD SECTION=TractionAI
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2222]
ParameterName=Economy Input Voltage
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_IN
;SEVCONFIELD SECTION=TractionAI
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2223]
ParameterName=Steer Pot Input Voltage
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_IN
;SEVCONFIELD SECTION=TractionAI
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2224]
ParameterName=Throttle 2 Input Voltage
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_IN
;SEVCONFIELD SECTION=TractionAI
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2240]
ParameterName=Pump Throttle 1 Input Voltage
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_IN
;SEVCONFIELD SECTION=TractionAI
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2241]
ParameterName=Pump Throttle 2 Input Voltage
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_IN
;SEVCONFIELD SECTION=TractionAI
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2320]
ParameterName=Traction Drive Hour-meter output
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=ro
LowLimit=0
HighLimit=1
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=DIGITAL_SIGNAL_OUT
;SEVCONFIELD SECTION=TractionDO
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2400]
ParameterName=Line contactor
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT
;SEVCONFIELD SECTION=VehicleAO
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2401]
ParameterName=External LED
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT
;SEVCONFIELD SECTION=VehicleAO
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2402]
ParameterName=Alarm buzzer
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT
;SEVCONFIELD SECTION=VehicleAO
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2403]
ParameterName=Horn
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT
;SEVCONFIELD SECTION=VehicleAO
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2404]
ParameterName=Brake Lights
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT
;SEVCONFIELD SECTION=VehicleAO
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2405]
ParameterName=Service Due
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT
;SEVCONFIELD SECTION=VehicleAO
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2420]
ParameterName=Electro-mechanical brake
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT
;SEVCONFIELD SECTION=TractionAO
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2421]
ParameterName=Traction Motor Cooling Fan
ParameterValue=0x7fff
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT
;SEVCONFIELD SECTION=TractionAO
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2422]
ParameterName=Motor Isolation Contactor
ParameterValue=0x7fff
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT
;SEVCONFIELD SECTION=TractionAO
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2423]
ParameterName=High / Low Speed Indication
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT
;SEVCONFIELD SECTION=TractionAO
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2440]
ParameterName=Pump contactor
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT
;SEVCONFIELD SECTION=PumpAO
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2460]
ParameterName=Power steer contactor
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_OUT
;SEVCONFIELD SECTION=PSteerAO
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2620]
ParameterName=Throttle Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE
;SEVCONFIELD SECTION=TractionAO
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2621]
ParameterName=Footbrake Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE
;SEVCONFIELD SECTION=TractionAO
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2622]
ParameterName=Economy Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE
;SEVCONFIELD SECTION=TractionAO
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2623]
ParameterName=Steer Angle
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE
;SEVCONFIELD SECTION=TractionAO
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2624]
ParameterName=Steer Angle (in degrees)
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-9000
HighLimit=9000
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.01
;SEVCONFIELD UNITS=Degrees
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE
;SEVCONFIELD SECTION=TractionValue
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2626]
ParameterName=Secondary Throttle Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE
;SEVCONFIELD SECTION=TractionAO
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2640]
ParameterName=Pump Throttle 1 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE
;SEVCONFIELD SECTION=PumpAO
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2641]
ParameterName=Pump Throttle 2 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD OBJECT=ANALOGUE_SIGNAL_VALUE
;SEVCONFIELD SECTION=PumpAO
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2720]
SubNumber=6
ObjectType=9
ParameterName=Traction Application Status
;SEVCONFIELD OBJECT=TRACTION_STATUS
;SEVCONFIELD SECTION=TractionStatus
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2720sub0]
ParameterName=Number of entries
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=5
;SEVCONFIELD OBJECT_VERSION=1
[2720sub1]
ParameterName=Driveability Profile Status
ParameterValue=0x0001
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=6
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Baseline
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Driveability Select 1
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Driveability Select 2
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Inactive
;SEVCONFIELD 1=Active
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Low Speed
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=On
;SEVCONFIELD 1=Off
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=BDI
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=On
;SEVCONFIELD 1=Off
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Service
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=On
;SEVCONFIELD 1=Off
[2720sub2]
ParameterName=Traction Drive State
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=11
;SEVCONFIELD 0=OFF
;SEVCONFIELD 1=FOOTBRAKING
;SEVCONFIELD 2=DRIVE
;SEVCONFIELD 3=STOP_AT_CD_RATE
;SEVCONFIELD 4=CD_DECEL
;SEVCONFIELD 5=CD_ACCEL
;SEVCONFIELD 6=NTRL_BRK_OR_COAST
;SEVCONFIELD 7=HILL_HOLD
;SEVCONFIELD 8=IDLE
;SEVCONFIELD 9=POWER_OFF
;SEVCONFIELD 10=CONTROLLED_ROLL_OFF
[2720sub3]
ParameterName=Drive / Direction Change State
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=7
;SEVCONFIELD 0=NO_DIR_SEL_NO_LDD
;SEVCONFIELD 1=FWD_SEL_LDD_FWD
;SEVCONFIELD 2=NO_DIR_SEL_LDD_FWD
;SEVCONFIELD 3=REV_SEL_LDD_FWD
;SEVCONFIELD 4=FWD_SEL_LDD_REV
;SEVCONFIELD 5=NO_DIR_SEL_LDD_REV
;SEVCONFIELD 6=REV_SEL_LDD_REV
[2720sub4]
ParameterName=SRO State
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=5
;SEVCONFIELD 0=NO_FS1_NO_DIR
;SEVCONFIELD 1=NO_FS1_DIR_ACTIVE
;SEVCONFIELD 2=FS1_ACTIVE_NO_DIR
;SEVCONFIELD 3=FS1_ACTIVE_DIR_ACTIVE
;SEVCONFIELD 4=SRO_FAULT
[2720sub5]
ParameterName=Operator Presence (Seat) State
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=5
;SEVCONFIELD 0=SEAT_SWITCH_INACTIVE
;SEVCONFIELD 1=SEAT_SWITCH_ACTIVE
;SEVCONFIELD 2=IN_DRIVE
;SEVCONFIELD 3=SEAT_INACTIVE_IN_DRIVE
;SEVCONFIELD 4=SEAT_FAULT
[2721]
ParameterName=Vehicle Speed
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=kph
;SEVCONFIELD OBJECT=VEHICLE_SPEED
;SEVCONFIELD SECTION=TractionStatus
;SEVCONFIELD EEPROM=app_stat.speed_info.vehicle_speed
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2722]
ParameterName=User speed 1
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=VEHICLE_SPEED
;SEVCONFIELD SECTION=TractionStatus
;SEVCONFIELD EEPROM=app_stat.speed_info.user_speed
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2723]
ParameterName=User speed 2
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=VEHICLE_SPEED
;SEVCONFIELD SECTION=TractionStatus
;SEVCONFIELD EEPROM=app_stat.speed_info.user_speed_2
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2740]
SubNumber=3
ObjectType=9
ParameterName=Pump Application Status
;SEVCONFIELD OBJECT=PUMP_STATUS
;SEVCONFIELD SECTION=PUMPSTATUS
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2740sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[2740sub1]
ParameterName=Pump Drive State
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=6
;SEVCONFIELD 0=OFF
;SEVCONFIELD 1=NEUTRAL
;SEVCONFIELD 2=PUMP_REQ_BUT_INHIBITED
;SEVCONFIELD 3=PUMP_INHIBIT
;SEVCONFIELD 4=PUMP
;SEVCONFIELD 5=PUMP_DURING_INHIBIT
[2740sub2]
ParameterName=Pump Driveability Profile Status
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=3
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Baseline
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=On
;SEVCONFIELD 1=Off
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Driveability Select 1
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=On
;SEVCONFIELD 1=Off
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Driveability Select 2
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=On
;SEVCONFIELD 1=Off
[2760]
SubNumber=2
ObjectType=9
ParameterName=Power Steer Application Status
;SEVCONFIELD OBJECT=PSTEER_STATUS
;SEVCONFIELD SECTION=PSTEERSTATUS
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2760sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[2760sub1]
ParameterName=Power Steer Drive State
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=4
;SEVCONFIELD 0=OFF
;SEVCONFIELD 1=NEUTRAL
;SEVCONFIELD 2=WAIT_FOR_TIMEOUT
;SEVCONFIELD 3=POWER_STEER
[2781]
SubNumber=3
ObjectType=9
ParameterName=Key Hours Counter
;SEVCONFIELD OBJECT=HOURS_COUNTER
;SEVCONFIELD SECTION=HoursCounters
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=LOGGING
[2781sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2781sub1]
ParameterName=Hours
ParameterValue=0x0031
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=Hours
[2781sub2]
ParameterName=Minutes / Seconds
ParameterValue=0xb4
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xEF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[2782]
SubNumber=3
ObjectType=9
ParameterName=Traction Hours Counter
;SEVCONFIELD OBJECT=HOURS_COUNTER
;SEVCONFIELD SECTION=HoursCounters
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=LOGGING
[2782sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2782sub1]
ParameterName=Hours
ParameterValue=0x0003
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=Hours
[2782sub2]
ParameterName=Minutes / Seconds
ParameterValue=0xba
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xEF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[2783]
SubNumber=3
ObjectType=9
ParameterName=Pump Hours Counter
;SEVCONFIELD OBJECT=HOURS_COUNTER
;SEVCONFIELD SECTION=HoursCounters
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=LOGGING
[2783sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2783sub1]
ParameterName=Hours
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=Hours
[2783sub2]
ParameterName=Minutes / Seconds
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xEF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[2784]
SubNumber=3
ObjectType=9
ParameterName=Power Steer Hours Counter
;SEVCONFIELD OBJECT=HOURS_COUNTER
;SEVCONFIELD SECTION=HoursCounters
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=LOGGING
[2784sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2784sub1]
ParameterName=Hours
ParameterValue=0x0005
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=Hours
[2784sub2]
ParameterName=Minutes / Seconds
ParameterValue=0x2e
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xEF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[2785]
SubNumber=3
ObjectType=9
ParameterName=Work Hours Counter
;SEVCONFIELD OBJECT=HOURS_COUNTER
;SEVCONFIELD SECTION=HoursCounters
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=LOGGING
[2785sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2785sub1]
ParameterName=Hours
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=Hours
[2785sub2]
ParameterName=Minutes / Seconds
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xEF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[2786]
SubNumber=3
ObjectType=9
ParameterName=Charging Hours Counter
;SEVCONFIELD OBJECT=HOURS_COUNTER
;SEVCONFIELD SECTION=HoursCounters
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=LOGGING
[2786sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2786sub1]
ParameterName=Hours
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=Hours
[2786sub2]
ParameterName=Minutes / Seconds
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xEF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[278F]
ParameterName=Running indicators
ParameterValue=0x0005
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=HOURS_COUNTER
;SEVCONFIELD SECTION=HoursCounters
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=8
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Node Hours
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Stopped
;SEVCONFIELD 1=Running
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Pulsing Hours
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Stopped
;SEVCONFIELD 1=Running
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Key Hours
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Stopped
;SEVCONFIELD 1=Running
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Traction Hours
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Stopped
;SEVCONFIELD 1=Running
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=Pump Hours
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Stopped
;SEVCONFIELD 1=Running
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Power Steer Hours
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Stopped
;SEVCONFIELD 1=Running
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=Work Hours
;SEVCONFIELD BITMASK=0x40
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Stopped
;SEVCONFIELD 1=Running
;SEVCONFIELD SPLIT=7
[2790]
SubNumber=2
ObjectType=9
ParameterName=Battery Status
;SEVCONFIELD OBJECT=BatteryStatus
;SEVCONFIELD SECTION=BatteryStatus
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2790sub0]
ParameterName=Number of parameters
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[2790sub1]
ParameterName=BDI remaining charge
ParameterValue=0x40
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=%
[2800]
ParameterName=Force system to pre-operational state
ParameterValue=0x01
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=FORCE_TO_PREOP
;SEVCONFIELD SECTION=CANopenSetup
;SEVCONFIELD EEPROM=vehicle.force_to_pre_op
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Operational
;SEVCONFIELD 1=Pre-Operational
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=MONITORING
[2810]
SubNumber=8
ObjectType=9
ParameterName=Node Indication
;SEVCONFIELD OBJECT=NODE_INDICATION
;SEVCONFIELD SECTION=CANopenSetup
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2810sub0]
ParameterName=Number of slaves
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=7
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vehicle.number_slaves
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2810sub1]
ParameterName=1st slave node ID
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=127
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vehicle.slave_node_id_0
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2810sub2]
ParameterName=2nd slave node ID
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=127
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vehicle.slave_node_id_1
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2810sub3]
ParameterName=3rd slave node ID
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=127
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vehicle.slave_node_id_2
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2810sub4]
ParameterName=4th slave node ID
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=127
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vehicle.slave_node_id_3
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2810sub5]
ParameterName=5th slave node ID
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=127
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vehicle.slave_node_id_4
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2810sub6]
ParameterName=6th slave node ID
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=127
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vehicle.slave_node_id_5
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2810sub7]
ParameterName=7th slave node ID
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=127
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vehicle.slave_node_id_6
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2820]
SubNumber=4
ObjectType=9
ParameterName=Line Contactor parameters
;SEVCONFIELD OBJECT=LINE_CONT_PARAM
;SEVCONFIELD SECTION=VehicleConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2820sub0]
ParameterName=Number of parameters
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2820sub1]
ParameterName=Line contactor drop out
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vehicle.line_contactor_drop_enabled
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2820sub2]
ParameterName=Line contactor drop out timer
ParameterValue=0x3c
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=10
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=vehicle.line_contactor_drop_timer
[2820sub3]
ParameterName=Line contactor options
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=1
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Line Contactor Welded Fault
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Enabled
;SEVCONFIELD 1=Disabled
[2830]
ParameterName=Assumed fault severity level for EMCY received from non-sevcon nodes.
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=5
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=NON_SEVCON_EMCY_LEVEL
;SEVCONFIELD SECTION=CANOPENSETUP
;SEVCONFIELD EEPROM=vehicle.anon_emcy_severity
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2840]
SubNumber=12
ObjectType=9
ParameterName=Alarm Buzzer Configuration
;SEVCONFIELD OBJECT=BUZZER_CONFIG
;SEVCONFIELD SECTION=VehicleConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2840sub0]
ParameterName=Number of parameters
ParameterValue=0x0b
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=17
;SEVCONFIELD OBJECT_VERSION=1
[2840sub1]
ParameterName=Alarm buzzer source enable flags.
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0x0F
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vehicle.buzzer_enable
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=6
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Forward
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Reverse
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Roll off
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Fault
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=BDI low
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=ELYT low
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
[2840sub2]
ParameterName=Forward Cadence On Time
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[0][0]
[2840sub3]
ParameterName=Forward Cadence Off Time
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=4
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[0][1]
[2840sub4]
ParameterName=Reverse Cadence On Time
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[1][0]
[2840sub5]
ParameterName=Reverse Cadence Off Time
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[1][1]
[2840sub6]
ParameterName=Fault Cadence On Time
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[2][0]
[2840sub7]
ParameterName=Fault Cadence Off Time
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[2][1]
[2840sub8]
ParameterName=Controlled Roll Off Cadence On Time
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=4
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[3][0]
[2840sub9]
ParameterName=Controlled Roll Off Cadence Off Time
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=vehicle.buzzer_cadance[3][1]
[2840subA]
ParameterName=BDI low Cadence On Time
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=misc.bdi_cadence[0]
[2840subB]
ParameterName=BDI low Cadence Off Time
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=misc.bdi_cadence[1]
[2850]
SubNumber=6
ObjectType=9
ParameterName=Servicing
;SEVCONFIELD OBJECT=SERVICE_CONFIG
;SEVCONFIELD SECTION=VehicleConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2850sub0]
ParameterName=Number of parameters
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=5
;SEVCONFIELD OBJECT_VERSION=1
[2850sub1]
ParameterName=Reset (write to reset next service time)
ObjectType=7
DataType=1
AccessType=wo
LowLimit=0
HighLimit=0x1
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=1
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Reset
;SEVCONFIELD 1=Reset
[2850sub2]
ParameterName=Flags
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=vehicle.service_flags
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=3
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Enable Service
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=On
;SEVCONFIELD 1=Off
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Activate Contactor Drive
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Flash LED
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
[2850sub3]
ParameterName=Source Hours Counter
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0x80
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=vehicle.service_source
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2850sub4]
ParameterName=Time between services (Service Interval)
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
;SEVCONFIELD EEPROM=vehicle.service_interval
[2850sub5]
ParameterName=Next Service Due time
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
DefaultValue=0xFFFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
;SEVCONFIELD EEPROM=vehicle.service_next_due
[2870]
SubNumber=8
ObjectType=9
ParameterName=Master Battery Current Limit Parameters
;SEVCONFIELD OBJECT=IBATT_LIMIT_PARAM
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2870sub0]
ParameterName=Number of parameters
ParameterValue=0x07
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=7
;SEVCONFIELD OBJECT_VERSION=1
[2870sub1]
ParameterName=Battery current limit data source
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=4
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=traction.traction_mode
;SEVCONFIELD NUMBER_FORMAT=5
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Use max currents only
;SEVCONFIELD 2=Use Delaware BMS
;SEVCONFIELD 3=Follow Profiles
;SEVCONFIELD 4=Use max power
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2870sub2]
ParameterName=Maximum battery discharge current
ParameterValue=0x0078
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=1
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=A
[2870sub3]
ParameterName=Maximum battery recharge current
ParameterValue=0xff9c
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=0
PDOMapping=1
DefaultValue=0xFF9C
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=A
[2870sub4]
ParameterName=Maximum battery discharge current in Drive Profile 1
ParameterValue=0x0050
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=100
PDOMapping=1
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=%
[2870sub5]
ParameterName=Maximum battery discharge current in Drive Profile 2
ParameterValue=0x001e
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=100
PDOMapping=1
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=%
[2870sub6]
ParameterName=Maximum battery discharge power
ParameterValue=0x0a00
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=1
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=kW
[2870sub7]
ParameterName=Maximum battery recharge power
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=0
PDOMapping=1
DefaultValue=0xFF9C
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=kW
[2871]
SubNumber=3
ObjectType=9
ParameterName=Master Battery Current Limit Status
;SEVCONFIELD OBJECT=IBATT_LIMIT_STATUS
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2871sub0]
ParameterName=Number of parameters
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2871sub1]
ParameterName=Available traction battery discharge current
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=32767
PDOMapping=1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=A
[2871sub2]
ParameterName=Available traction battery charge current
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=0
PDOMapping=1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=A
[2872]
SubNumber=3
ObjectType=9
ParameterName=Battery Current Limit Protection Parameters
;SEVCONFIELD OBJECT=IBATT_LIMIT_PROTECTION
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2872sub0]
ParameterName=Number of parameters
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2872sub1]
ParameterName=Cutback range for low traction discharge current
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=A
[2872sub2]
ParameterName=Cutback range for low traction charge current
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=0
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=A
[2900]
ParameterName=Traction control mode (Torque/speed mode (0) or closed loop speed control (1))
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=TRAC_CTRL_MODE
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD EEPROM=traction.traction_mode
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Torque/Speed
;SEVCONFIELD 1=Speed Control
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2901]
ParameterName=Hill hold delay
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD OBJECT=HILL_HOLD_DELAY
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD EEPROM=traction.hill_hold_delay
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2902]
ParameterName=Seat Switch delay
ParameterValue=0x14
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=20
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD OBJECT=SEAT_DELAY
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD EEPROM=traction.seat_delay
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2903]
SubNumber=4
ObjectType=9
ParameterName=Electromechanical Brake parameters
;SEVCONFIELD OBJECT=EBRAKE_PARAM
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2903sub0]
ParameterName=Number of parameters
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[2903sub1]
ParameterName=Electromechanical brake apply delay
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=50
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=traction.ebrake_apply_delay
[2903sub2]
ParameterName=Electromechanical brake release delay
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=traction.ebrake_release_delay
[2903sub3]
ParameterName=Electromechanical brake control
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Release after motor started
;SEVCONFIELD 1=Release immediately
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2904]
SubNumber=2
ObjectType=9
ParameterName=High speed parameters
;SEVCONFIELD OBJECT=HIGH_SPEED_PARAM
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2904sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[2904sub1]
ParameterName=Latched / momentary operation
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=traction.high_speed_latched_momentary
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Latched
;SEVCONFIELD 1=Momentary
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2906]
SubNumber=2
ObjectType=9
ParameterName=Low Speed Profile Configuration
;SEVCONFIELD OBJECT=LOW_SPEED_PRO_CONFIG
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2906sub0]
ParameterName=Number of parameters
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[2906sub1]
ParameterName=Speed below which low speed profile is active
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=misc.low_speed_threshold
[2907]
SubNumber=4
ObjectType=9
ParameterName=High/Low Speed Indication Configuration
;SEVCONFIELD OBJECT=SPEED_INDICATION_CONFIG
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2907sub0]
ParameterName=Number of parameters
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[2907sub1]
ParameterName=Activation Speed
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=misc.high_low_speed_ind_act_speed
[2907sub2]
ParameterName=Deactivation Speed
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=misc.high_low_speed_ind_deact_speed
[2907sub3]
ParameterName=Analogue output voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=misc.high_low_speed_ind_ao_voltage
[2908]
ParameterName=Drive torque disable speed
ParameterValue=0x012c
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=500
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD OBJECT=DRIVE_TRQ_DISABLE_SPEED
;SEVCONFIELD EEPROM=misc.trac_drive_disable_speed
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2909]
ParameterName=Direction change delay
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD OBJECT=DIR_CHANGE_DELAY
;SEVCONFIELD EEPROM=misc.trac_dir_change_delay
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[290A]
SubNumber=4
ObjectType=9
ParameterName=S-Curve Control
;SEVCONFIELD OBJECT=S_CURVE_PARAM
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[290Asub0]
ParameterName=Number of parameters
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[290Asub1]
ParameterName=Target speed approach curve
ParameterValue=0x08
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=11
PDOMapping=0
DefaultValue=8
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=misc.s_curve_factor_a
[290Asub2]
ParameterName=Ramp change delay
ParameterValue=0x7f
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=127
PDOMapping=0
DefaultValue=0x7F
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=misc.s_curve_factor_b
[290Asub3]
ParameterName=Ramp change delay speed
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=misc.s_curve_speed
[290B]
SubNumber=3
ObjectType=9
ParameterName=Tilt Alarm Delays
;SEVCONFIELD OBJECT=TILT_ALARM_DELAYS
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[290Bsub0]
ParameterName=Number of parameters
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=8
;SEVCONFIELD OBJECT_VERSION=1
[290Bsub1]
ParameterName=Off delay
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
[290Bsub2]
ParameterName=On delay
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
[290C]
SubNumber=4
ObjectType=9
ParameterName=Belly operation configuration
;SEVCONFIELD OBJECT=BELLY_CONFIGURATION
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[290Csub0]
ParameterName=Number of parameters
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[290Csub1]
ParameterName=Belly throttle value
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=16384
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.belly_throttle
[290Csub2]
ParameterName=Belly max speed
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=5000
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=misc.belly_max_speed
[290Csub3]
ParameterName=Belly timeout
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=100
PDOMapping=0
DefaultValue=50
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=misc.belly_timeout
[290D]
ParameterName=Neutral Braking Exit Timer
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.001
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD OBJECT=NTRL_BRK_EXIT_DELAY
;SEVCONFIELD EEPROM=misc.ntrl_brk_exit_delay
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[290E]
SubNumber=4
ObjectType=9
ParameterName=Brake Feathering
;SEVCONFIELD OBJECT=BRAKE_FEATHERING
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[290Esub0]
ParameterName=Number of parameters
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=5
;SEVCONFIELD OBJECT_VERSION=1
[290Esub1]
ParameterName=Brake feathering start speed
ParameterValue=0x1388
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=300
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=RPM
[290Esub2]
ParameterName=Brake feathering end speed
ParameterValue=0x0dac
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=50
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=RPM
[290Esub3]
ParameterName=Brake feathering end torque
ParameterValue=0x00c8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.001
[2910]
SubNumber=17
ObjectType=9
ParameterName=Throttle parameters
;SEVCONFIELD OBJECT=THROTTLE_PARAM
;SEVCONFIELD SECTION=TractionAIConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2910sub0]
ParameterName=Number of parameters
ParameterValue=0x10
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=22
;SEVCONFIELD OBJECT_VERSION=1
[2910sub1]
ParameterName=Throttle Flags
ParameterValue=0x0070
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=traction.throttle_flags
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=16
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Proportional Braking
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Directional Throttle
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Speed Limit Mode
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Proportional to throttle
;SEVCONFIELD 1=Fixed at maximum
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Braking Directional Throttle
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=Reverse Speed Limit Encoding
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Handbrake Fault
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Enabled
;SEVCONFIELD 1=Disabled
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=Proportional Speed Limit in Braking
;SEVCONFIELD BITMASK=0x40
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Enabled
;SEVCONFIELD 1=Disabled
;SEVCONFIELD SPLIT=7
;SEVCONFIELD PARAMETERNAME=Driveability profile generation style (some builds only)
;SEVCONFIELD BITMASK=0x80
;SEVCONFIELD BITSHIFT=0x7
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Use lowest values
;SEVCONFIELD 1=Use active profile only
;SEVCONFIELD SPLIT=8
;SEVCONFIELD PARAMETERNAME=Allow step change in steer angle
;SEVCONFIELD BITMASK=0x100
;SEVCONFIELD BITSHIFT=0x8
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=9
;SEVCONFIELD PARAMETERNAME=Virtual FS1
;SEVCONFIELD BITMASK=0x200
;SEVCONFIELD BITSHIFT=0x9
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=10
;SEVCONFIELD PARAMETERNAME=Absolute Steer Angle in single traction
;SEVCONFIELD BITMASK=0x400
;SEVCONFIELD BITSHIFT=0xA
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=11
;SEVCONFIELD PARAMETERNAME=Separate Seat Regen Braking settings
;SEVCONFIELD BITMASK=0x800
;SEVCONFIELD BITSHIFT=0xB
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=12
;SEVCONFIELD PARAMETERNAME=Slave Left Motor Speed Inversion
;SEVCONFIELD BITMASK=0x1000
;SEVCONFIELD BITSHIFT=0xC
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=13
;SEVCONFIELD PARAMETERNAME=Brake Light when Neutral Braking
;SEVCONFIELD BITMASK=0x2000
;SEVCONFIELD BITSHIFT=0xD
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=14
;SEVCONFIELD PARAMETERNAME=Inching functionality
;SEVCONFIELD BITMASK=0x4000
;SEVCONFIELD BITSHIFT=0xE
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Generic
;SEVCONFIELD 1=With E.Park Brake
;SEVCONFIELD SPLIT=15
;SEVCONFIELD PARAMETERNAME=Proportional Speed Limit in Drive
;SEVCONFIELD BITMASK=0x8000
;SEVCONFIELD BITSHIFT=0xF
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Enabled
;SEVCONFIELD 1=Disabled
[2910sub2]
ParameterName=Throttle input characteristic
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=3
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=1
;SEVCONFIELD EEPROM=traction.throttle_char
;SEVCONFIELD NUMBER_FORMAT=4
;SEVCONFIELD 0=User Defd
;SEVCONFIELD 1=Linear
;SEVCONFIELD 2=Curved
;SEVCONFIELD 3=Crawl
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2910sub3]
ParameterName=Throttle Start Voltage 1
ParameterValue=0x0033
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=16
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=traction.throttle_0_start_voltage
[2910sub4]
ParameterName=Throttle Start Value 1
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.throttle_0_start_value
[2910sub5]
ParameterName=Throttle End Voltage 1
ParameterValue=0x05b3
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=1309
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=traction.throttle_0_end_voltage
[2910sub6]
ParameterName=Throttle End Value 1
ParameterValue=0x7ffe
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.throttle_0_end_value
[2910sub7]
ParameterName=Throttle Start Voltage 2
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=traction.throttle_1_start_voltage
[2910sub8]
ParameterName=Throttle Start Value 2
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.throttle_1_start_value
[2910sub9]
ParameterName=Throttle End Voltage 2
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=traction.throttle_1_end_voltage
[2910subA]
ParameterName=Throttle End Value 2
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.throttle_1_end_value
[2910subB]
ParameterName=User Defined Char Pt 1 Voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=9830
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=traction.throttle_ud_map_0_voltage
[2910subC]
ParameterName=User Defined Char Pt 1 Value
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=9830
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=traction.throttle_ud_map_0_value
[2910subD]
ParameterName=User Defined Char Pt 2 Voltage
ParameterValue=0x8000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=19660
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=traction.throttle_ud_map_1_voltage
[2910subE]
ParameterName=User Defined Char Pt 2 Value
ParameterValue=0x8000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=traction.throttle_ud_map_1_value
[2910subF]
ParameterName=User Defined Char Pt 3 Voltage
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=52428
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=traction.throttle_ud_map_2_voltage
[2910sub10]
ParameterName=User Defined Char Pt 3 Value
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=62258
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=traction.throttle_ud_map_2_value
[2911]
SubNumber=15
ObjectType=9
ParameterName=Footbrake parameters
;SEVCONFIELD OBJECT=FBRAKE_PARAM
;SEVCONFIELD SECTION=TractionAIConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2911sub0]
ParameterName=Number of parameters
ParameterValue=0x0e
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=13
;SEVCONFIELD OBJECT_VERSION=1
[2911sub1]
ParameterName=Drive / footbrake priority
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=traction.drive_footbrake_priority
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Drive
;SEVCONFIELD 1=Footbrake
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2911sub2]
ParameterName=Footbrake braking exit speed
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=traction.footbrake_minimum_speed
[2911sub3]
ParameterName=Footbrake Input Characteristic
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=3
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=traction.footbrake_char
;SEVCONFIELD NUMBER_FORMAT=4
;SEVCONFIELD 0=User Defined
;SEVCONFIELD 1=Linear
;SEVCONFIELD 2=Curved
;SEVCONFIELD 3=Crawl
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2911sub4]
ParameterName=Footbrake Start Voltage 1
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=traction.footbrake_start_voltage
[2911sub5]
ParameterName=Footbrake Start Value 1
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.footbrake_start_value
[2911sub6]
ParameterName=Footbrake End Voltage 1
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=900
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=traction.footbrake_end_voltage
[2911sub7]
ParameterName=Footbrake End Value 1
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.footbrake_end_value
[2911sub8]
ParameterName=User Defined Char Pt 1 Voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=9830
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=traction.footbrake_ud_map_0_voltage
[2911sub9]
ParameterName=User Defined Char Pt 1 Value
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=9830
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=traction.footbrake_ud_map_0_value
[2911subA]
ParameterName=User Defined Char Pt 2 Voltage
ParameterValue=0x8000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=19660
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=traction.footbrake_ud_map_1_voltage
[2911subB]
ParameterName=User Defined Char Pt 2 Value
ParameterValue=0x8000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=traction.footbrake_ud_map_1_value
[2911subC]
ParameterName=User Defined Char Pt 3 Voltage
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=52428
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=traction.footbrake_ud_map_2_voltage
[2911subD]
ParameterName=User Defined Char Pt 3 Value
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=62258
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=traction.footbrake_ud_map_2_value
[2911subE]
ParameterName=Footbrake/Drive time out
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=misc.footbrake_timeout
[2912]
SubNumber=6
ObjectType=9
ParameterName=Economy parameters
;SEVCONFIELD OBJECT=ECONOMY_PARAM
;SEVCONFIELD SECTION=TractionAIConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2912sub0]
ParameterName=Number of parameters
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=5
;SEVCONFIELD OBJECT_VERSION=1
[2912sub1]
ParameterName=Economy function
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=2
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=traction.economy_function
;SEVCONFIELD NUMBER_FORMAT=3
;SEVCONFIELD 0=None
;SEVCONFIELD 1=Max Torque
;SEVCONFIELD 2=Accel Rate
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2912sub2]
ParameterName=Economy Start Voltage 1
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=traction.economy_start_voltage
[2912sub3]
ParameterName=Economy Start Value 1
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.economy_start_value
[2912sub4]
ParameterName=Economy End Voltage 1
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=900
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=traction.economy_end_voltage
[2912sub5]
ParameterName=Economy End Value 1
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.economy_end_value
[2913]
SubNumber=20
ObjectType=9
ParameterName=Steering parameters
;SEVCONFIELD OBJECT=STEERING_PARAM
;SEVCONFIELD SECTION=TractionAIConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2913sub0]
ParameterName=Number of parameters
ParameterValue=0x13
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=19
;SEVCONFIELD OBJECT_VERSION=1
[2913sub1]
ParameterName=Steer pot left voltage
ParameterValue=0x0064
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=traction.steer_left_voltage
[2913sub2]
ParameterName=Steer pot right voltage
ParameterValue=0x0384
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=900
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=traction.steer_right_voltage
[2913sub3]
ParameterName=Steer pot zero voltage
ParameterValue=0x01f4
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=500
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=traction.steer_zero_voltage
[2913sub4]
ParameterName=Angle (Outer Wheel) Pt 1
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=2.74666585283975E-03
;SEVCONFIELD EEPROM=traction.steering_cutback_map_0_angle
[2913sub5]
ParameterName=Cutback (Outer Wheel) Pt 1
ParameterValue=0x7fff
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.steering_cutback_map_0_speed
[2913sub6]
ParameterName=Angle (Outer Wheel) Pt 2
ParameterValue=0x0ccc
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=3276
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=2.74666585283975E-03
;SEVCONFIELD EEPROM=traction.steering_cutback_map_1_angle
[2913sub7]
ParameterName=Cutback (Outer Wheel) Pt 2
ParameterValue=0x7fff
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.steering_cutback_map_1_speed
[2913sub8]
ParameterName=Angle (Outer Wheel) Pt 3
ParameterValue=0x5999
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=22937
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=2.74666585283975E-03
;SEVCONFIELD EEPROM=traction.steering_cutback_map_2_angle
[2913sub9]
ParameterName=Cutback (Outer Wheel) Pt 3
ParameterValue=0x7fff
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=22937
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.steering_cutback_map_2_speed
[2913subA]
ParameterName=Angle (Outer Wheel) Pt 4
ParameterValue=0x7fff
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=2.74666585283975E-03
;SEVCONFIELD EEPROM=traction.steering_cutback_map_3_angle
[2913subB]
ParameterName=Cutback (Outer Wheel) Pt 4
ParameterValue=0x7fff
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=3276
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.steering_cutback_map_3_speed
[2913subC]
ParameterName=Angle (Inner Wheel) Pt 1
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=2.74666585283975E-03
;SEVCONFIELD EEPROM=traction.steering_map_0_angle
[2913subD]
ParameterName=Cutback (Inner Wheel) Pt 1
ParameterValue=0x7fff
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.steering_map_0_speed
[2913subE]
ParameterName=Angle (Inner Wheel) Pt 2
ParameterValue=0x051e
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=1310
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=2.74666585283975E-03
;SEVCONFIELD EEPROM=traction.steering_map_1_angle
[2913subF]
ParameterName=Cutback (Inner Wheel) Pt 2
ParameterValue=0x7fff
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.steering_map_1_speed
[2913sub10]
ParameterName=Angle (Inner Wheel) Pt 3
ParameterValue=0x5554
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=22937
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=2.74666585283975E-03
;SEVCONFIELD EEPROM=traction.steering_map_2_angle
[2913sub11]
ParameterName=Cutback (Inner Wheel) Pt 3
ParameterValue=0x3332
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.steering_map_2_speed
[2913sub12]
ParameterName=Angle (Inner Wheel) Pt 4
ParameterValue=0x7fff
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=2.74666585283975E-03
;SEVCONFIELD EEPROM=traction.steering_map_3_angle
[2913sub13]
ParameterName=Cutback (Inner Wheel) Pt 4
ParameterValue=0x3332
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=-3276
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=traction.steering_map_3_speed
[2914]
SubNumber=3
ObjectType=9
ParameterName=FS1 Parameters
;SEVCONFIELD OBJECT=FS1_PARAM
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2914sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2914sub1]
ParameterName=FS1 Flags
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=traction.fs1_flags
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=2
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=NOT_USED
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=FS1 Recycle
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
[2914sub2]
ParameterName=SRO delay
ParameterValue=0x0a
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=20
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=traction.sro_delay
[2915]
SubNumber=10
ObjectType=9
ParameterName=Motor to vehicle speed ratio
;SEVCONFIELD OBJECT=GEAR_RATIO
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2915sub0]
ParameterName=Number of entries
ParameterValue=0x09
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[2915sub1]
ParameterName=Vehicle speed numerator
ParameterValue=0x0020
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=traction.gear_ratio_numerator
[2915sub2]
ParameterName=Vehicle speed denominator
ParameterValue=0x0018
ObjectType=7
DataType=6
AccessType=rw
LowLimit=1
HighLimit=65535
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=traction.gear_ratio_denominator
[2915sub3]
ParameterName=Ignore vehicle speed ratio for driveability profiles
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=misc.gear_ratio_ignore_for_profiles
[2915sub4]
ParameterName=User speed 1 numerator
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=misc.user_gear_ratio.numerator
[2915sub5]
ParameterName=User speed 1 denominator
ParameterValue=0x0001
ObjectType=7
DataType=6
AccessType=rw
LowLimit=1
HighLimit=65535
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=misc.user_gear_ratio.denominator
[2915sub6]
ParameterName=Allow negative user speeds
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=misc.allow_negative_user_speeds
[2915sub7]
ParameterName=User speed 2 numerator
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=misc.user_2_gear_ratio.numerator
[2915sub8]
ParameterName=User speed 2 denominator
ParameterValue=0x0001
ObjectType=7
DataType=6
AccessType=rw
LowLimit=1
HighLimit=65535
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=misc.user_2_gear_ratio.denominator
[2915sub9]
ParameterName=Allow negative user speeds for user speed 2
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=misc.allow_negative_user_speeds_2
[2916]
SubNumber=2
ObjectType=9
ParameterName=Traction Motor Parameters
;SEVCONFIELD OBJECT=TRAC_MOTOR_PARAM
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2916sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[2916sub1]
ParameterName=Traction Motor Rated Torque
ParameterValue=0x000061a8
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=2000000
PDOMapping=0
DefaultValue=25000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.001
;SEVCONFIELD UNITS=Nm
;SEVCONFIELD EEPROM=traction.motor_rated_torque
[2918]
ParameterName=Sequence Fault Mask (set bit to ignore input during sequence fault check)
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=TRAC_SEQ_FLT_MASK
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD EEPROM=misc.seq_flt_mask
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=11
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Throttle direction
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Forward
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Reverse
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=FS1
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=Inch Fwd
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Inch Rev
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=Deadman
;SEVCONFIELD BITMASK=0x40
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=7
;SEVCONFIELD PARAMETERNAME=Belly
;SEVCONFIELD BITMASK=0x80
;SEVCONFIELD BITSHIFT=0x7
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=8
;SEVCONFIELD PARAMETERNAME=Belt Fwd
;SEVCONFIELD BITMASK=0x100
;SEVCONFIELD BITSHIFT=0x8
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=9
;SEVCONFIELD PARAMETERNAME=Belt Rev
;SEVCONFIELD BITMASK=0x200
;SEVCONFIELD BITSHIFT=0x9
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=10
;SEVCONFIELD PARAMETERNAME=Belt Stop
;SEVCONFIELD BITMASK=0x400
;SEVCONFIELD BITSHIFT=0xA
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
[2919]
SubNumber=4
ObjectType=9
ParameterName=Inching parameters
;SEVCONFIELD OBJECT=GEAR_RATIO
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2919sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[2919sub1]
ParameterName=Inch speed
ParameterValue=0x00c8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1500
PDOMapping=0
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm
;SEVCONFIELD EEPROM=misc.traction_inch_speed
[2919sub2]
ParameterName=Inch timeout
ParameterValue=0x07d0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=5000
PDOMapping=0
DefaultValue=5000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=ms
;SEVCONFIELD EEPROM=misc.traction_inch_timeout
[2919sub3]
ParameterName=Inch throttle
ParameterValue=0x7fff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0x2000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.inch_throttle
[291A]
ParameterName=Traction Fault Clear Mask (set bit to ignore input during traction fault neutral check)
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=TRAC_SEQ_FLT_MASK
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD EEPROM=misc.trc_flt_clear_mask
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=8
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Throttle direction
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Forward
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Reverse
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=FS1
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=Inch Fwd
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Inch Rev
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=Deadman
;SEVCONFIELD BITMASK=0x40
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
;SEVCONFIELD SPLIT=7
;SEVCONFIELD PARAMETERNAME=Belly
;SEVCONFIELD BITMASK=0x80
;SEVCONFIELD BITSHIFT=0x7
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Check
;SEVCONFIELD 1=Ignore
[291C]
SubNumber=3
ObjectType=9
ParameterName=Gearbox oscillation reduction
;SEVCONFIELD OBJECT=GEARBOX_OSC_REDUCTION
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[291Csub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[291Csub1]
ParameterName=Torque to use slower ramp to
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
[291Csub2]
ParameterName=Gear mesh reduction ramp rate
ParameterValue=0x2710
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
[291E]
SubNumber=3
ObjectType=9
ParameterName=Speed Limit Configuration
;SEVCONFIELD OBJECT=MAX_SPEED_LIMIT_RAMP
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[291Esub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[291Esub1]
ParameterName=Maximum allowable speed limit increase rate
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0xFFFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm/s
[291Esub2]
ParameterName=Maximum allowable speed limit decrease rate
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0xFFFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm/s
[291F]
ParameterName=Creep Torque
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=500
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.001
;SEVCONFIELD OBJECT=CREEP_TORQUE
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2920]
SubNumber=17
ObjectType=9
ParameterName=Traction baseline profile
;SEVCONFIELD OBJECT=DRIVEABILITY_PROFILE
;SEVCONFIELD SECTION=TractionDriveability
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2920sub0]
ParameterName=Number of parameters
ParameterValue=0x10
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=16
;SEVCONFIELD OBJECT_VERSION=1
[2920sub1]
ParameterName=Maximum Torque applied during drive
ParameterValue=0x03e8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=traction.baseline_pro_0
[2920sub2]
ParameterName=Maximum Torque applied during a direction change
ParameterValue=0x00c8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=500
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=traction.baseline_pro_1
[2920sub3]
ParameterName=Maximum Torque applied when neutral braking
ParameterValue=0x0064
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=traction.baseline_pro_2
[2920sub4]
ParameterName=Maximum Torque applied when footbraking
ParameterValue=0x00c8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=500
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=traction.baseline_pro_3
[2920sub5]
ParameterName=Maximum Speed in forward direction
ParameterValue=0x157c
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=5000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm
;SEVCONFIELD EEPROM=traction.baseline_pro_4
[2920sub6]
ParameterName=Maximum Speed in reverse direction
ParameterValue=0x1388
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm
;SEVCONFIELD EEPROM=traction.baseline_pro_5
[2920sub7]
ParameterName=Ramp up rate during drive
ParameterValue=0x07d0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.baseline_pro_6
[2920sub8]
ParameterName=Ramp up rate during direction change braking
ParameterValue=0x07d0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.baseline_pro_7
[2920sub9]
ParameterName=Ramp up rate during neutral braking
ParameterValue=0x07d0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.baseline_pro_8
[2920subA]
ParameterName=Ramp up rate during footbraking
ParameterValue=0x07d0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.baseline_pro_9
[2920subB]
ParameterName=Ramp down rate during drive
ParameterValue=0x07d0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.baseline_pro_10
[2920subC]
ParameterName=Ramp down rate during direction change braking
ParameterValue=0x07d0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.baseline_pro_11
[2920subD]
ParameterName=Ramp down rate during neutral braking
ParameterValue=0x07d0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.baseline_pro_12
[2920subE]
ParameterName=Ramp down rate during footbraking
ParameterValue=0x07d0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.baseline_pro_13
[2920subF]
ParameterName=Speed limit ramp up rate when in torque mode
ParameterValue=0x1770
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=2000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm/s
;SEVCONFIELD EEPROM=traction.baseline_pro_14
[2920sub10]
ParameterName=Speed limit ramp down rate when in torque mode
ParameterValue=0x03e8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=300
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm/s
;SEVCONFIELD EEPROM=traction.baseline_pro_15
[2921]
SubNumber=17
ObjectType=9
ParameterName=Driveability Select 1 Profile
;SEVCONFIELD OBJECT=DRIVEABILITY_PROFILE
;SEVCONFIELD SECTION=TractionDriveability
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2921sub0]
ParameterName=Number of parameters
ParameterValue=0x10
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=16
;SEVCONFIELD OBJECT_VERSION=1
[2921sub1]
ParameterName=Maximum Torque applied during drive
ParameterValue=0x03e8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_0
[2921sub2]
ParameterName=Maximum Torque applied during a direction change
ParameterValue=0x03e8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=500
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_1
[2921sub3]
ParameterName=Maximum Torque applied when neutral braking
ParameterValue=0x00c8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_2
[2921sub4]
ParameterName=Maximum Torque applied when footbraking
ParameterValue=0x03e8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=500
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_3
[2921sub5]
ParameterName=Maximum Speed in forward direction
ParameterValue=0x1388
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=5000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_4
[2921sub6]
ParameterName=Maximum Speed in reverse direction
ParameterValue=0x1388
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_5
[2921sub7]
ParameterName=Ramp up rate during drive
ParameterValue=0x1f40
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_6
[2921sub8]
ParameterName=Ramp up rate during direction change braking
ParameterValue=0x0bb8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_7
[2921sub9]
ParameterName=Ramp up rate during neutral braking
ParameterValue=0x0bb8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_8
[2921subA]
ParameterName=Ramp up rate during footbraking
ParameterValue=0x0bb8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_9
[2921subB]
ParameterName=Ramp down rate during drive
ParameterValue=0xc350
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_10
[2921subC]
ParameterName=Ramp down rate during direction change braking
ParameterValue=0xc350
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_11
[2921subD]
ParameterName=Ramp down rate during neutral braking
ParameterValue=0xc350
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_12
[2921subE]
ParameterName=Ramp down rate during footbraking
ParameterValue=0xc350
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_13
[2921subF]
ParameterName=Speed limit ramp up rate when in torque mode
ParameterValue=0x07d0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=2000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm/s
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_14
[2921sub10]
ParameterName=Speed limit ramp down rate when in torque mode
ParameterValue=0x012c
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=300
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm/s
;SEVCONFIELD EEPROM=traction.drv_sel_1_pro_15
[2922]
SubNumber=17
ObjectType=9
ParameterName=Driveability Select 2 Profile
;SEVCONFIELD OBJECT=DRIVEABILITY_PROFILE
;SEVCONFIELD SECTION=TractionDriveability
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2922sub0]
ParameterName=Number of parameters
ParameterValue=0x10
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=16
;SEVCONFIELD OBJECT_VERSION=1
[2922sub1]
ParameterName=Maximum Torque applied during drive
ParameterValue=0x03e8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_0
[2922sub2]
ParameterName=Maximum Torque applied during a direction change
ParameterValue=0x03e8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=500
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_1
[2922sub3]
ParameterName=Maximum Torque applied when neutral braking
ParameterValue=0x00c8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_2
[2922sub4]
ParameterName=Maximum Torque applied when footbraking
ParameterValue=0x03e8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=500
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_3
[2922sub5]
ParameterName=Maximum Speed in forward direction
ParameterValue=0x1388
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=5000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_4
[2922sub6]
ParameterName=Maximum Speed in reverse direction
ParameterValue=0x1388
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_5
[2922sub7]
ParameterName=Ramp up rate during drive
ParameterValue=0x1f40
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_6
[2922sub8]
ParameterName=Ramp up rate during direction change braking
ParameterValue=0x0bb8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_7
[2922sub9]
ParameterName=Ramp up rate during neutral braking
ParameterValue=0x0bb8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_8
[2922subA]
ParameterName=Ramp up rate during footbraking
ParameterValue=0x0bb8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_9
[2922subB]
ParameterName=Ramp down rate during drive
ParameterValue=0xc350
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_10
[2922subC]
ParameterName=Ramp down rate during direction change braking
ParameterValue=0xc350
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_11
[2922subD]
ParameterName=Ramp down rate during neutral braking
ParameterValue=0xc350
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_12
[2922subE]
ParameterName=Ramp down rate during footbraking
ParameterValue=0xc350
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_13
[2922subF]
ParameterName=Speed limit ramp up rate when in torque mode
ParameterValue=0x07d0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=2000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm/s
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_14
[2922sub10]
ParameterName=Speed limit ramp down rate when in torque mode
ParameterValue=0x012c
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=300
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm/s
;SEVCONFIELD EEPROM=traction.drv_sel_2_pro_15
[2928]
SubNumber=4
ObjectType=9
ParameterName=Seat Regen Parameters
;SEVCONFIELD OBJECT=SEAT_REGEN
;SEVCONFIELD SECTION=SeatConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2928sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=4
;SEVCONFIELD OBJECT_VERSION=1
[2928sub1]
ParameterName=Maximum Torque applied during seat activated braking
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=500
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=misc.seat_max_braking_torque
[2928sub2]
ParameterName=Ramp up rate during seat activated braking
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=misc.seat_regen_ramp_up_rate
[2928sub3]
ParameterName=Ramp down rate during seat activated braking
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%/s
;SEVCONFIELD EEPROM=misc.seat_regen_ramp_down_rate
[2930]
SubNumber=4
ObjectType=9
ParameterName=Controlled Roll Off parameters
;SEVCONFIELD OBJECT=ROLL_OFF_PARAM
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2930sub0]
ParameterName=Number of parameters
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[2930sub1]
ParameterName=Controlled Roll Off
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=traction.roll_off_enabled
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2930sub2]
ParameterName=Maximum torque applied in Controlled Roll Off
ParameterValue=0x03e8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=32000
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=traction.roll_off_maximum_torque
[2930sub3]
ParameterName=Maximum speed allowed in Controlled Roll Off
ParameterValue=0x0064
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=rpm
;SEVCONFIELD EEPROM=traction.roll_off_maximum_speed
[2931]
SubNumber=4
ObjectType=9
ParameterName=Drivability Select Profile Triggers
;SEVCONFIELD OBJECT=ROLL_OFF_PARAM
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2931sub0]
ParameterName=Number of parameters
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2931sub1]
ParameterName=Drivability Select 1 Profile Triggers
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0x0F
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=misc.drv_sel_triggers_pro1
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=4
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Low BDI activates profile
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Low speed activates profile
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Service interval activates profile
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Battery Electrolyte Low activates profile
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
[2931sub2]
ParameterName=Drivability Select 2 Profile Triggers
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0x0F
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=misc.drv_sel_triggers_pro2
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=4
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Low BDI activates profile
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Low speed activates profile
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Service interval activates profile
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Battery Electrolyte Low activates profile
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
[2931sub3]
ParameterName=Use active drivability values only
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=misc.use_active_profile_only
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Use lowest values from all active profiles
;SEVCONFIELD 1=Use active profile only
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2933]
ParameterName=Torque demand S-curve
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=10
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=TORQUE_S_CURVE
;SEVCONFIELD SECTION=TractionConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[29A0]
SubNumber=4
ObjectType=9
ParameterName=Odometer Counter
;SEVCONFIELD OBJECT=ODOMETER_COUNTER
;SEVCONFIELD SECTION=OdometerCounter
;SEVCONFIELD CATEGORY=LOGGING
[29A0sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[29A0sub1]
ParameterName=Odometer distance in Km
ParameterValue=0x00006df4
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=km
[29A0sub2]
ParameterName=Odometer distance in Km
ParameterValue=0x0000044b
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=km
[29A0sub3]
ParameterName=Odometer distance in miles
ParameterValue=0x000002aa
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=miles
[29A1]
SubNumber=4
ObjectType=9
ParameterName=Trip Meter Counter
;SEVCONFIELD OBJECT=TRIP_METER_COUNTER
;SEVCONFIELD SECTION=OdometerCounter
;SEVCONFIELD CATEGORY=LOGGING
[29A1sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[29A1sub1]
ParameterName=Trip Distance in km
ParameterValue=0x00006df4
ObjectType=7
DataType=7
AccessType=ro
LowLimit=
HighLimit=0xFFFFFFFF
PDOMapping=1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=km
[29A1sub2]
ParameterName=Trip Distance in km
ParameterValue=0x0000044b
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=km
[29A1sub3]
ParameterName=Trip Distance in miles
ParameterValue=0x000002aa
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=miles
[2A00]
SubNumber=2
ObjectType=9
ParameterName=General Pump Features
;SEVCONFIELD OBJECT=PUMP_PARAM
;SEVCONFIELD SECTION=PumpConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2A00sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[2A00sub1]
ParameterName=Pump Flags
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=3
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD EEPROM=pump.general_flags
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=9
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=BDI Inhibit
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Ignored
;SEVCONFIELD 1=Inhibits pump
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Drive Enable
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Ignored
;SEVCONFIELD 1=Disables pump
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Seat Switch
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Ignored
;SEVCONFIELD 1=Disables pump
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Line Contactor
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Ignored
;SEVCONFIELD 1=Disables pump
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=Add Power Steer Speed to Pump Speed
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Minimum speed without trigger
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=Pump to stop on low battery
;SEVCONFIELD BITMASK=0x40
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=7
;SEVCONFIELD PARAMETERNAME=Use power steer speed as minimum pump speed
;SEVCONFIELD BITMASK=0x80
;SEVCONFIELD BITSHIFT=0x7
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=8
;SEVCONFIELD PARAMETERNAME=Use power steer motor as 2nd pump motor
;SEVCONFIELD BITMASK=0x100
;SEVCONFIELD BITSHIFT=0x8
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
[2A01]
SubNumber=6
ObjectType=9
ParameterName=Pump Motor Parameters
;SEVCONFIELD OBJECT=PUMP_MOTOR_PARAM
;SEVCONFIELD SECTION=PumpConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2A01sub0]
ParameterName=Number of entries
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=5
;SEVCONFIELD OBJECT_VERSION=1
[2A01sub1]
ParameterName=Pump Motor Maximum Speed
ParameterValue=0x09c4
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=2500
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=pump.motor_max_speed
[2A01sub2]
ParameterName=Pump Motor Minimum Speed
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=pump.motor_min_speed
[2A01sub3]
ParameterName=Pump Motor Acceleration Rate
ParameterValue=0x0fa0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=rpm/s
;SEVCONFIELD EEPROM=pump.motor_acceleration
[2A01sub4]
ParameterName=Pump Motor Deceleration Rate
ParameterValue=0x0fa0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=rpm/s
;SEVCONFIELD EEPROM=pump.motor_deceleration
[2A01sub5]
ParameterName=Maximum Torque Applied in Baseline Profile
ParameterValue=0x03e8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.001
;SEVCONFIELD UNITS=
;SEVCONFIELD EEPROM=misc.pump_base_torque_limit
[2A10]
SubNumber=13
ObjectType=9
ParameterName=Pump Throttle 1 parameters
;SEVCONFIELD OBJECT=PUMP_THROTTLE_PARAM
;SEVCONFIELD SECTION=PUMPCONFIG
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2A10sub0]
ParameterName=Number of parameters
ParameterValue=0x0c
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=12
;SEVCONFIELD OBJECT_VERSION=1
[2A10sub1]
ParameterName=Priority Level / Additive
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD EEPROM=pump.throttles_0_priority
[2A10sub2]
ParameterName=Input Characteristic
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=3
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=1
;SEVCONFIELD NUMBER_FORMAT=4
;SEVCONFIELD 0=User Defd
;SEVCONFIELD 1=Linear
;SEVCONFIELD 2=Curved
;SEVCONFIELD 3=Crawl
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD EEPROM=pump.throttles_0_ip_char
[2A10sub3]
ParameterName=Pump throttle 1 Start Voltage
ParameterValue=0x000a
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=16
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=pump.throttles_0_ip_start_voltage
[2A10sub4]
ParameterName=Pump throttle 1 Start Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=pump.throttles_0_ip_start_value
[2A10sub5]
ParameterName=Pump throttle 1 End Voltage
ParameterValue=0x2710
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=1309
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=pump.throttles_0_ip_end_voltage
[2A10sub6]
ParameterName=Pump throttle 1 End Value
ParameterValue=0x7fff
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=pump.throttles_0_ip_end_value
[2A10sub7]
ParameterName=User Defined Char Pt 1 Voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=9830
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=pump.throttles_0_ud_map_0_voltage
[2A10sub8]
ParameterName=User Defined Char Pt 1 Value
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=9830
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=pump.throttles_0_ud_map_0_value
[2A10sub9]
ParameterName=User Defined Char Pt 2 Voltage
ParameterValue=0x8000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=19660
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=pump.throttles_0_ud_map_1_voltage
[2A10subA]
ParameterName=User Defined Char Pt 2 Value
ParameterValue=0x8000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=pump.throttles_0_ud_map_1_value
[2A10subB]
ParameterName=User Defined Char Pt 3 Voltage
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=52428
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=pump.throttles_0_ud_map_2_voltage
[2A10subC]
ParameterName=User Defined Char Pt 3 Value
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=62258
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=pump.throttles_0_ud_map_2_value
[2A11]
SubNumber=13
ObjectType=9
ParameterName=Pump Throttle 2 parameters
;SEVCONFIELD OBJECT=PUMP_THROTTLE_PARAM
;SEVCONFIELD SECTION=PUMPCONFIG
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2A11sub0]
ParameterName=Number of parameters
ParameterValue=0x0c
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=12
;SEVCONFIELD OBJECT_VERSION=1
[2A11sub1]
ParameterName=Priority Level / Additive
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD EEPROM=pump.throttles_1_priority
[2A11sub2]
ParameterName=Input Characteristic
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=3
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD NUMBER_FORMAT=4
;SEVCONFIELD 0=User Defd
;SEVCONFIELD 1=Linear
;SEVCONFIELD 2=Curved
;SEVCONFIELD 3=Crawl
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD EEPROM=pump.throttles_1_ip_char
[2A11sub3]
ParameterName=Pump throttle 2 Start Voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=16
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=pump.throttles_1_ip_start_voltage
[2A11sub4]
ParameterName=Pump throttle 2 Start Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=pump.throttles_1_ip_start_value
[2A11sub5]
ParameterName=Pump throttle 2 End Voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=1309
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=pump.throttles_1_ip_end_voltage
[2A11sub6]
ParameterName=Pump throttle 2 End Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=pump.throttles_1_ip_end_value
[2A11sub7]
ParameterName=User Defined Char Pt 1 Voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=9830
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=pump.throttles_1_ud_map_0_voltage
[2A11sub8]
ParameterName=User Defined Char Pt 1 Value
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=9830
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=pump.throttles_1_ud_map_0_value
[2A11sub9]
ParameterName=User Defined Char Pt 2 Voltage
ParameterValue=0x8000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=19660
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=pump.throttles_1_ud_map_1_voltage
[2A11subA]
ParameterName=User Defined Char Pt 2 Value
ParameterValue=0x8000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=pump.throttles_1_ud_map_1_value
[2A11subB]
ParameterName=User Defined Char Pt 3 Voltage
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=52428
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=pump.throttles_1_ud_map_2_voltage
[2A11subC]
ParameterName=User Defined Char Pt 3 Value
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=62258
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52590218966964E-05
;SEVCONFIELD EEPROM=pump.throttles_1_ud_map_2_value
[2A20]
SubNumber=3
ObjectType=9
ParameterName=Pump Switch 1 parameters
;SEVCONFIELD OBJECT=PUMP_SWITCH_PARAM
;SEVCONFIELD SECTION=PUMPCONFIG
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2A20sub0]
ParameterName=Number of parameters
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2A20sub1]
ParameterName=Priority Level / Additive
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD EEPROM=pump.switches_0_priority
[2A20sub2]
ParameterName=Pump Switch 1 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=pump.switches_0_value
[2A21]
SubNumber=3
ObjectType=9
ParameterName=Pump Switch 2 parameters
;SEVCONFIELD OBJECT=PUMP_SWITCH_PARAM
;SEVCONFIELD SECTION=PUMPCONFIG
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2A21sub0]
ParameterName=Number of parameters
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2A21sub1]
ParameterName=Priority Level / Additive
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD EEPROM=pump.switches_1_priority
[2A21sub2]
ParameterName=Pump Switch 2 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=pump.switches_1_value
[2A22]
SubNumber=3
ObjectType=9
ParameterName=Pump Switch 3 parameters
;SEVCONFIELD OBJECT=PUMP_SWITCH_PARAM
;SEVCONFIELD SECTION=PUMPCONFIG
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2A22sub0]
ParameterName=Number of parameters
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2A22sub1]
ParameterName=Priority Level / Additive
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD EEPROM=pump.switches_2_priority
[2A22sub2]
ParameterName=Pump Switch 3 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=pump.switches_2_value
[2A23]
SubNumber=3
ObjectType=9
ParameterName=Pump Switch 4 parameters
;SEVCONFIELD OBJECT=PUMP_SWITCH_PARAM
;SEVCONFIELD SECTION=PUMPCONFIG
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2A23sub0]
ParameterName=Number of parameters
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2A23sub1]
ParameterName=Priority Level / Additive
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD EEPROM=pump.switches_3_priority
[2A23sub2]
ParameterName=Pump Switch 4 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=pump.switches_3_value
[2A24]
SubNumber=3
ObjectType=9
ParameterName=Pump Switch 5 parameters
;SEVCONFIELD OBJECT=PUMP_SWITCH_PARAM
;SEVCONFIELD SECTION=PUMPCONFIG
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2A24sub0]
ParameterName=Number of parameters
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2A24sub1]
ParameterName=Priority Level / Additive
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD EEPROM=pump.switches_4_priority
[2A24sub2]
ParameterName=Pump Switch 5 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=pump.switches_4_value
[2A25]
SubNumber=3
ObjectType=9
ParameterName=Pump Switch 6 parameters
;SEVCONFIELD OBJECT=PUMP_SWITCH_PARAM
;SEVCONFIELD SECTION=PUMPCONFIG
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2A25sub0]
ParameterName=Number of parameters
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2A25sub1]
ParameterName=Priority Level / Additive
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD EEPROM=pump.switches_5_priority
[2A25sub2]
ParameterName=Pump Switch 6 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=pump.switches_5_value
[2A26]
SubNumber=3
ObjectType=9
ParameterName=Pump Switch 7 parameters
;SEVCONFIELD OBJECT=PUMP_SWITCH_PARAM
;SEVCONFIELD SECTION=PUMPCONFIG
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2A26sub0]
ParameterName=Number of parameters
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2A26sub1]
ParameterName=Priority Level / Additive
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD EEPROM=pump.switches_6_priority
[2A26sub2]
ParameterName=Pump Switch 7 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=pump.switches_6_value
[2A30]
SubNumber=13
ObjectType=9
ParameterName=Pump Driveability Profile 1 parameters
;SEVCONFIELD OBJECT=PUMP_PROFILE_PARAM
;SEVCONFIELD SECTION=PUMPCONFIG
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2A30sub0]
ParameterName=Number of parameters
ParameterValue=0x0c
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=12
;SEVCONFIELD OBJECT_VERSION=1
[2A30sub1]
ParameterName=Maximum Pump Motor Acceleration Rate
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=10000
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=rpm/s
;SEVCONFIELD EEPROM=misc.pump_drv1_accel_rate
[2A30sub2]
ParameterName=Maximum Pump Motor Deceleration Rate
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=10000
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=rpm/s
;SEVCONFIELD EEPROM=misc.pump_drv1_decel_rate
[2A30sub3]
ParameterName=Maximum Pump Throttle 1 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv1_value0
[2A30sub4]
ParameterName=Maximum Pump Throttle 2 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv1_value0
[2A30sub5]
ParameterName=Maximum Pump Switch 1 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv1_value0
[2A30sub6]
ParameterName=Maximum Pump Switch 2 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv1_value0
[2A30sub7]
ParameterName=Maximum Pump Switch 3 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv1_value0
[2A30sub8]
ParameterName=Maximum Pump Switch 4 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv1_value0
[2A30sub9]
ParameterName=Maximum Pump Switch 5 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv1_value0
[2A30subA]
ParameterName=Maximum Pump Switch 6 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv1_value0
[2A30subB]
ParameterName=Maximum Pump Switch 7 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv1_value0
[2A30subC]
ParameterName=Maximum Torque Applied in Pump Driveability Profile 1
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.001
;SEVCONFIELD UNITS=
;SEVCONFIELD EEPROM=misc.pump_drv1_torque_limit
[2A31]
SubNumber=13
ObjectType=9
ParameterName=Pump Driveability Profile 2 parameters
;SEVCONFIELD OBJECT=PUMP_PROFILE_PARAM
;SEVCONFIELD SECTION=PUMPCONFIG
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2A31sub0]
ParameterName=Number of parameters
ParameterValue=0x0c
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=12
;SEVCONFIELD OBJECT_VERSION=1
[2A31sub1]
ParameterName=Maximum Pump Motor Acceleration Rate
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=10000
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=rpm/s
;SEVCONFIELD EEPROM=misc.pump_drv2_accel_rate
[2A31sub2]
ParameterName=Maximum Pump Motor Deceleration Rate
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=10000
PDOMapping=0
DefaultValue=10000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=rpm/s
;SEVCONFIELD EEPROM=misc.pump_drv2_decel_rate
[2A31sub3]
ParameterName=Maximum Pump Throttle 1 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv2_value0
[2A31sub4]
ParameterName=Maximum Pump Throttle 2 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv2_value0
[2A31sub5]
ParameterName=Maximum Pump Switch 1 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv2_value0
[2A31sub6]
ParameterName=Maximum Pump Switch 2 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv2_value0
[2A31sub7]
ParameterName=Maximum Pump Switch 3 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv2_value0
[2A31sub8]
ParameterName=Maximum Pump Switch 4 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv2_value0
[2A31sub9]
ParameterName=Maximum Pump Switch 5 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv2_value0
[2A31subA]
ParameterName=Maximum Pump Switch 6 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv2_value0
[2A31subB]
ParameterName=Maximum Pump Switch 7 Value
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
;SEVCONFIELD EEPROM=misc.pump_drv2_value0
[2A31subC]
ParameterName=Maximum Torque Applied in Pump Driveability Profile 2
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.001
;SEVCONFIELD UNITS=
;SEVCONFIELD EEPROM=misc.pump_drv2_torque_limit
[2B00]
SubNumber=3
ObjectType=9
ParameterName=General Power steer features
;SEVCONFIELD OBJECT=PSTEER_PARAM
;SEVCONFIELD SECTION=PsteerConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2B00sub0]
ParameterName=Number of parameters
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2B00sub1]
ParameterName=Power steer delay
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=pwr_str.power_steer_delay
[2B00sub2]
ParameterName=Power steer trigger (set bit to enable trigger)
ParameterValue=0x07
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=pwr_str.internal_trigger
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=6
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Vehicle Moving
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=FS1 Switch
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Direction
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Seat Switch
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=Footbrake
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=INCH switches
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
[2B01]
SubNumber=4
ObjectType=9
ParameterName=Power Steer Motor Speed
;SEVCONFIELD OBJECT=PSTEER_MOTOR_PARAM
;SEVCONFIELD SECTION=PsteerConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2B01sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[2B01sub1]
ParameterName=Power Steer Motor Speed
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=500
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=pwr_str.speed_demand
[2B01sub2]
ParameterName=Power Steer Motor Acceleration Rate
ParameterValue=0x0100
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=500
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=rpm/s
;SEVCONFIELD EEPROM=pwr_str.acceleration
[2B01sub3]
ParameterName=Power Steer Motor Deceleration Rate
ParameterValue=0x0100
ObjectType=7
DataType=6
AccessType=rw
LowLimit=10
HighLimit=65535
PDOMapping=0
DefaultValue=500
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=rpm/s
;SEVCONFIELD EEPROM=pwr_str.deceleration
[2B02]
SubNumber=3
ObjectType=9
ParameterName=Variable Assist Power Steering
;SEVCONFIELD OBJECT=PSTEER_VAR_ASSIST_PARAM
;SEVCONFIELD SECTION=PsteerConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2B02sub0]
ParameterName=Number of parameters
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2B02sub1]
ParameterName=Power Steering Assist Maximum Speed
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=20000
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=RPM
[2B02sub2]
ParameterName=Power Steering Assist Cutback Factor
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=3.05185094759972E-05
[2C00]
ParameterName=Nominal battery voltage
ParameterValue=0x0500
ObjectType=7
DataType=6
AccessType=rw
LowLimit=384
HighLimit=3072
PDOMapping=0
DefaultValue=0x0300
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD OBJECT=NOM_BATT_V
;SEVCONFIELD SECTION=BatteryApplication
;SEVCONFIELD EEPROM=battery.nominal_battery
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2C01]
SubNumber=3
ObjectType=9
ParameterName=Battery over voltage protection
;SEVCONFIELD OBJECT=BATT_OVER_V_PROT
;SEVCONFIELD SECTION=BatteryProtection
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2C01sub0]
ParameterName=Number of parameters
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2C01sub1]
ParameterName=Over voltage start cutback
ParameterValue=0x0640
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0x03A0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=battery.high_v_start_cutback
[2C01sub2]
ParameterName=Over voltage limit
ParameterValue=0x0690
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0x0410
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=battery.high_v_limit
[2C02]
SubNumber=3
ObjectType=9
ParameterName=Battery under voltage protection
;SEVCONFIELD OBJECT=BATT_UNDER_V_PROT
;SEVCONFIELD SECTION=BatteryProtection
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2C02sub0]
ParameterName=Number of parameters
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2C02sub1]
ParameterName=Under voltage start cutback
ParameterValue=0x04b0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0x01c0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=battery.low_v_start_cutback
[2C02sub2]
ParameterName=Under voltage limit
ParameterValue=0x0490
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0x01a0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=battery.low_v_limit
[2C03]
ParameterName=Battery Protection Delay
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=10
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.1
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD OBJECT=NOM_BATT_V
;SEVCONFIELD SECTION=BatteryApplication
;SEVCONFIELD EEPROM=battery.protection_delay
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2C30]
SubNumber=9
ObjectType=9
ParameterName=BDI parameters
;SEVCONFIELD OBJECT=BDI_PARAM
;SEVCONFIELD SECTION=BDISetup
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2C30sub0]
ParameterName=Number of parameters
ParameterValue=0x08
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=7
;SEVCONFIELD OBJECT_VERSION=1
[2C30sub1]
ParameterName=BDI Flags
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=battery.bdi_flags
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=3
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Traction
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Pump
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=BDI Map
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
[2C30sub2]
ParameterName=Reset voltage (V)
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=210
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.01
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=battery.bdi_reset_voltage_level
[2C30sub3]
ParameterName=Discharge voltage (V)
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=173
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.01
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=battery.bdi_discharge_voltage_level
[2C30sub4]
ParameterName=Cutout level (%)
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=100
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=battery.bdi_cutout_level
[2C30sub5]
ParameterName=Warning level (%)
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=100
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=battery.bdi_warning_level
[2C30sub6]
ParameterName=Cell count
ParameterValue=0x50
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=24
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=battery.cell_count
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2C30sub7]
ParameterName=BDI Discharge Rate
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=16800
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.001
;SEVCONFIELD UNITS=s/%
;SEVCONFIELD EEPROM=battery.bdi_discharge
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2C30sub8]
ParameterName=BDI Reset Enable Level
ParameterValue=0x64
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=100
PDOMapping=0
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=battery.bdi_reset_enable_level
[2C31]
SubNumber=11
ObjectType=9
ParameterName=BDI Remaining Charge Map
;SEVCONFIELD OBJECT=BDI_REMAINING_MAP
;SEVCONFIELD SECTION=BDISetup
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2C31sub0]
ParameterName=Number of entries
ParameterValue=0x0a
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=16
;SEVCONFIELD OBJECT_VERSION=1
[2C31sub1]
ParameterName=Pt 1 Voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=42
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[0].battery_voltage
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2C31sub2]
ParameterName=Pt1 BDI Remaining Charge
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=10
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[0].BDI_Charge
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2C31sub3]
ParameterName=Pt 2 Voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=44
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[1].battery_voltage
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2C31sub4]
ParameterName=Pt 2 BDI Remaining Charge
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=30
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[1].BDI_Charge
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2C31sub5]
ParameterName=Pt 3 Voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=46
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[2].battery_voltage
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2C31sub6]
ParameterName=Pt 3 BDI Remaining Charge
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=50
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[2].BDI_Charge
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2C31sub7]
ParameterName=Pt 4 Voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=48
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[3].battery_voltage
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2C31sub8]
ParameterName=Pt 4 BDI Remaining Charge
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=70
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[3].BDI_Charge
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2C31sub9]
ParameterName=Pt 5 Voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=52
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[4].battery_voltage
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2C31subA]
ParameterName=Pt 5 BDI Remaining Charge
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=%
;SEVCONFIELD EEPROM=battery.bdi_discharge.config[4].BDI_Charge
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[2D00]
SubNumber=4
ObjectType=9
ParameterName=Contactor Output Configuration
;SEVCONFIELD OBJECT=CONTACTOR_PARAM
;SEVCONFIELD SECTION=VehicleConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2D00sub0]
ParameterName=Number of parameters
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[2D00sub1]
ParameterName=Pull-In Voltage
ParameterValue=0x50
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=48
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=contactor.pull_in_voltage
[2D00sub2]
ParameterName=Pull-In Time
ParameterValue=0x64
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.01
;SEVCONFIELD UNITS=Seconds
;SEVCONFIELD EEPROM=contactor.pull_in_time
[2D00sub3]
ParameterName=Hold-In Voltage
ParameterValue=0x50
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=36
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=contactor.hold_in_voltage
[2D01]
SubNumber=3
ObjectType=9
ParameterName=Voltage Control Enable
;SEVCONFIELD OBJECT=VOLTAGE_CTRL_ENABLE
;SEVCONFIELD SECTION=VehicleConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2D01sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2D01sub1]
ParameterName=Voltage Control Enable for Contactor Drives 1..8
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0xFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=contactor.voltage_control_enable_0
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=8
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Line Contactor
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Pump Contactor
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Power Steer Contactor
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Electromechanical Brake
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=External LED
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Traction Motor Cooling Fan
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=Buzzer
;SEVCONFIELD BITMASK=0x40
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=7
;SEVCONFIELD PARAMETERNAME=Horn
;SEVCONFIELD BITMASK=0x80
;SEVCONFIELD BITSHIFT=0x7
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
[2D01sub2]
ParameterName=Voltage Control Enable for Contactor Drives 9..16
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0xFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=contactor.voltage_control_enable_1
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=7
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Lights
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Service
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Motor Isolation
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Precharge Output
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=Belt Electromechanical Brake
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Belt ChangeOver Contactor
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=Electro-mechanical Park brake
;SEVCONFIELD BITMASK=0x40
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
[2D02]
SubNumber=3
ObjectType=9
ParameterName=Reduce to Hold Level Enable
;SEVCONFIELD OBJECT=REDUCE_TO_HOLD_LEVEL
;SEVCONFIELD SECTION=VehicleConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2D02sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2D02sub1]
ParameterName=Reduce to Hold Level Enable for Contactor Drives 1..8
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0xFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=contactor.reduction_enable_0
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=8
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Line Contactor
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Pump Contactor
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Power Steer Contactor
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Electromechanical Brake
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=External LED
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Traction Motor Cooling Fan
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=Buzzer
;SEVCONFIELD BITMASK=0x40
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=7
;SEVCONFIELD PARAMETERNAME=Horn
;SEVCONFIELD BITMASK=0x80
;SEVCONFIELD BITSHIFT=0x7
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
[2D02sub2]
ParameterName=Reduce to Hold Level Enable for Contactor Drives 9..16
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0xFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=contactor.reduction_enable_1
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=7
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Lights
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Service
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Motor Isolation
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Precharge Output
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=Belt Electromechanical Brake
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Belt ChangeOver Contactor
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=Electro-mechanical Park brake
;SEVCONFIELD BITMASK=0x40
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
[2E00]
SubNumber=3
ObjectType=9
ParameterName=Display Configuration
;SEVCONFIELD OBJECT=DISPLAY_CONFIGURATION
;SEVCONFIELD SECTION=VehicleConfig
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[2E00sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[2E00sub1]
ParameterName=Display Type
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=misc.display_config_type
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=No Display
;SEVCONFIELD 1=Smartview
[2E00sub2]
ParameterName=Display Information
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=7
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=misc.display_config_hours_count
;SEVCONFIELD NUMBER_FORMAT=7
;SEVCONFIELD 0=Key hours
;SEVCONFIELD 1=Traction hours
;SEVCONFIELD 2=Pump hours
;SEVCONFIELD 3=Charging hours
;SEVCONFIELD 4=Real Speed
;SEVCONFIELD 5=Real Speed & Key hrs
;SEVCONFIELD 6=Real Speed & Traction hrs
;SEVCONFIELD 7=Real Speed & Pump hrs
[3000]
SubNumber=2
ObjectType=9
ParameterName=Local Motor VPDO Mapping
;SEVCONFIELD OBJECT=LOCAL_MOTOR_MAPPING
;SEVCONFIELD SECTION=LocalMotorMapping
;SEVCONFIELD DUMMY_VPDO=0x20FF
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[3000sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.motor_number
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3000sub1]
ParameterName=Local Motor 1 VPDO Mapping
ParameterValue=0x2020
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8224
HighLimit=8447
PDOMapping=0
DefaultValue=0x2020
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.motor_0
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3200]
SubNumber=4
ObjectType=9
ParameterName=Analog output VPDO Mapping
;SEVCONFIELD OBJECT=LOCAL_ALG_OUT_MAPPING
;SEVCONFIELD SECTION=LocalAOMapping
;SEVCONFIELD DUMMY_VPDO=0x24FF
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[3200sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=3
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.alg_out_number
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3200sub1]
ParameterName=Analog Output 1 VPDO Mapping
ParameterValue=0x2400
ObjectType=7
DataType=6
AccessType=rw
LowLimit=9216
HighLimit=9471
PDOMapping=0
DefaultValue=0x2400
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.alg_out_0
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3200sub2]
ParameterName=Analog Output 2 VPDO Mapping
ParameterValue=0x24ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=9216
HighLimit=9471
PDOMapping=0
DefaultValue=0x2420
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.alg_out_1
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3200sub3]
ParameterName=Analog Output 3 VPDO Mapping
ParameterValue=0x24ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=9216
HighLimit=9471
PDOMapping=0
DefaultValue=0x2440
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.alg_out_2
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3300]
SubNumber=14
ObjectType=9
ParameterName=Digital input VPDO Mapping
;SEVCONFIELD OBJECT=LOCAL_DIG_IN_MAPPING
;SEVCONFIELD SECTION=LocalDIMapping
;SEVCONFIELD DUMMY_VPDO=0x21FF
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[3300sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=13
PDOMapping=0
DefaultValue=4
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.dig_in_number
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3300sub1]
ParameterName=Digital Input 1 VPDO Mapping
ParameterValue=0x2121
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8448
HighLimit=8703
PDOMapping=0
DefaultValue=0x2121
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.dig_in_0
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3300sub2]
ParameterName=Digital Input 2 VPDO Mapping
ParameterValue=0x2122
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8448
HighLimit=8703
PDOMapping=0
DefaultValue=0x2122
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.dig_in_1
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3300sub3]
ParameterName=Digital Input 3 VPDO Mapping
ParameterValue=0x2123
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8448
HighLimit=8703
PDOMapping=0
DefaultValue=0x2123
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.dig_in_2
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3300sub4]
ParameterName=Digital Input 4 VPDO Mapping
ParameterValue=0x21ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8448
HighLimit=8703
PDOMapping=0
DefaultValue=0x2124
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.dig_in_3
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3300sub5]
ParameterName=Digital Input 5 VPDO Mapping
ParameterValue=0x21ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8448
HighLimit=8703
PDOMapping=0
DefaultValue=0x2125
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.dig_in_4
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3300sub6]
ParameterName=Digital Input 6 VPDO Mapping
ParameterValue=0x21ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8448
HighLimit=8703
PDOMapping=0
DefaultValue=0x2126
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.dig_in_5
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3300sub7]
ParameterName=Digital Input 7 VPDO Mapping
ParameterValue=0x21ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8448
HighLimit=8703
PDOMapping=0
DefaultValue=0x2140
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.dig_in_6
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3300sub8]
ParameterName=Digital Input 8 VPDO Mapping
ParameterValue=0x21ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8448
HighLimit=8703
PDOMapping=0
DefaultValue=0x2160
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.dig_in_7
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3300sub9]
ParameterName=Digital Input 9 VPDO Mapping
ParameterValue=0x21ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8448
HighLimit=8703
PDOMapping=0
DefaultValue=0x21FF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.dig_in_8
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3300subA]
ParameterName=Digital Input 10 VPDO Mapping
ParameterValue=0x21ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8448
HighLimit=8703
PDOMapping=0
DefaultValue=0x21FF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.dig_in_9
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3300subB]
ParameterName=Digital Input 11 VPDO Mapping
ParameterValue=0x21ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8448
HighLimit=8703
PDOMapping=0
DefaultValue=0x21FF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.dig_in_10
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3300subC]
ParameterName=Digital Input 12 VPDO Mapping
ParameterValue=0x21ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8448
HighLimit=8703
PDOMapping=0
DefaultValue=0x21FF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.dig_in_11
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3300subD]
ParameterName=Digital Input 13 VPDO Mapping
ParameterValue=0x21ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8448
HighLimit=8703
PDOMapping=0
DefaultValue=0x21FF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.dig_in_12
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3400]
SubNumber=6
ObjectType=9
ParameterName=Analog input VPDO Mapping
;SEVCONFIELD OBJECT=LOCAL_ALG_IN_MAPPING
;SEVCONFIELD SECTION=LocalAIMapping
;SEVCONFIELD DUMMY_VPDO=0x22FF
;SEVCONFIELD MASTER=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[3400sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=5
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.alg_in_number
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3400sub1]
ParameterName=Analog Input 1 VPDO Mapping
ParameterValue=0x2220
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8736
HighLimit=8959
PDOMapping=0
DefaultValue=0x2220
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.alg_in_0
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3400sub2]
ParameterName=Analog Input 2 VPDO Mapping
ParameterValue=0x22ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8736
HighLimit=8959
PDOMapping=0
DefaultValue=0x2221
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.alg_in_1
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3400sub3]
ParameterName=Analog Input 3 VPDO Mapping
ParameterValue=0x22ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8736
HighLimit=8959
PDOMapping=0
DefaultValue=0x2222
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.alg_in_2
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3400sub4]
ParameterName=Analog Input 4 VPDO Mapping
ParameterValue=0x22ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8736
HighLimit=8959
PDOMapping=0
DefaultValue=0x22FF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.alg_in_3
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[3400sub5]
ParameterName=Analog Input 5 VPDO Mapping
ParameterValue=0x22ff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=8736
HighLimit=8959
PDOMapping=0
DefaultValue=0x22FF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=vpdos.alg_in_4
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4000]
SubNumber=2
ObjectType=9
ParameterName=Logging Control
;SEVCONFIELD OBJECT=ALL_LOGS_CTRL
;SEVCONFIELD SECTION=LogsReset
;SEVCONFIELD CATEGORY=LOGGING
[4000sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[4000sub1]
ParameterName=Reset (write to reset all logs)
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=5
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Reset
;SEVCONFIELD 1=Reset
;SEVCONFIELD COMMS_TIMEOUT=20000
[4100]
SubNumber=3
ObjectType=9
ParameterName=System FIFO Control
;SEVCONFIELD OBJECT=SYSTEM_FIFO_CTRL
;SEVCONFIELD SECTION=SystemLog
;SEVCONFIELD CATEGORY=LOGGING
[4100sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[4100sub1]
ParameterName=Reset (write to reset system FIFO)
ObjectType=7
DataType=1
AccessType=wo
LowLimit=0
HighLimit=1
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Reset
;SEVCONFIELD 1=Reset
;SEVCONFIELD COMMS_TIMEOUT=20000
[4100sub2]
ParameterName=Number of items in System FIFO
ParameterValue=0x000a
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
[4101]
ParameterName=Select System FIFO item to read in 4102h
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD OBJECT=SYSTEM_FIFO_IN
;SEVCONFIELD SECTION=SystemLog
;SEVCONFIELD CATEGORY=LOGGING
[4102]
SubNumber=7
ObjectType=9
ParameterName=System FIFO Output
;SEVCONFIELD OBJECT=SYSTEM_FIFO_OUT
;SEVCONFIELD SECTION=SystemLog
;SEVCONFIELD CATEGORY=LOGGING
[4102sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[4102sub1]
ParameterName=Event ID
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4102sub2]
ParameterName=Hours
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4102sub3]
ParameterName=Minutes / Seconds
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4102sub4]
ParameterName=Data Byte 1
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4102sub5]
ParameterName=Data Byte 2
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4102sub6]
ParameterName=Data Byte 3
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4110]
SubNumber=3
ObjectType=9
ParameterName=Faults FIFO Control
;SEVCONFIELD OBJECT=FAULTS_FIFO_CTRL
;SEVCONFIELD SECTION=FaultLog
;SEVCONFIELD CATEGORY=LOGGING
[4110sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[4110sub1]
ParameterName=Reset (write to reset faults FIFO)
ObjectType=7
DataType=1
AccessType=wo
LowLimit=0
HighLimit=1
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Reset
;SEVCONFIELD 1=Reset
;SEVCONFIELD COMMS_TIMEOUT=20000
[4110sub2]
ParameterName=Number of items in Faults FIFO
ParameterValue=0x0028
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
[4111]
ParameterName=Select Faults FIFO item to read in 4102h
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD OBJECT=FAULTS_FIFO_IN
;SEVCONFIELD SECTION=FaultLog
;SEVCONFIELD CATEGORY=LOGGING
[4112]
SubNumber=7
ObjectType=9
ParameterName=Faults FIFO Output
;SEVCONFIELD OBJECT=FAULTS_FIFO_OUT
;SEVCONFIELD SECTION=FaultLog
;SEVCONFIELD CATEGORY=LOGGING
[4112sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[4112sub1]
ParameterName=Event ID
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4112sub2]
ParameterName=Hours
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4112sub3]
ParameterName=Minutes / Seconds
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4112sub4]
ParameterName=Data Byte 1
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4112sub5]
ParameterName=Data Byte 2
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4112sub6]
ParameterName=Data Byte 3
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4200]
SubNumber=2
ObjectType=9
ParameterName=Other Event Log Control
;SEVCONFIELD OBJECT=OTHER_EventLog_CTRL
;SEVCONFIELD SECTION=EventLog
;SEVCONFIELD CATEGORY=LOGGING
[4200sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[4200sub1]
ParameterName=Reset (write to reset event counters)
ObjectType=7
DataType=1
AccessType=wo
LowLimit=0
HighLimit=1
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Reset
;SEVCONFIELD 1=Reset
;SEVCONFIELD COMMS_TIMEOUT=20000
[4201]
SubNumber=7
ObjectType=9
ParameterName=Other Event Counter 1
;SEVCONFIELD OBJECT=EVENT_COUNTER
;SEVCONFIELD SECTION=EventLog
;SEVCONFIELD CATEGORY=LOGGING
[4201sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[4201sub1]
ParameterName=Event ID
ParameterValue=0x4f4c
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=logging.ev_ctrs[0].mask
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4201sub2]
ParameterName=First Event Hours
ParameterValue=0x001a
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4201sub3]
ParameterName=First Event Minutes / Seconds
ParameterValue=0x67
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4201sub4]
ParameterName=Last Event Hours
ParameterValue=0x002d
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4201sub5]
ParameterName=Last Event Minutes / Seconds
ParameterValue=0x8c
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4201sub6]
ParameterName=Counter
ParameterValue=0x0013
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
[4202]
SubNumber=7
ObjectType=9
ParameterName=Other Event Counter 2
;SEVCONFIELD OBJECT=EVENT_COUNTER
;SEVCONFIELD SECTION=EventLog
;SEVCONFIELD CATEGORY=LOGGING
[4202sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[4202sub1]
ParameterName=Event ID
ParameterValue=0x5101
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=logging.ev_ctrs[1].mask
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4202sub2]
ParameterName=First Event Hours
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4202sub3]
ParameterName=First Event Minutes / Seconds
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4202sub4]
ParameterName=Last Event Hours
ParameterValue=0x0013
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4202sub5]
ParameterName=Last Event Minutes / Seconds
ParameterValue=0x9e
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4202sub6]
ParameterName=Counter
ParameterValue=0x0033
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
[4203]
SubNumber=7
ObjectType=9
ParameterName=Other Event Counter 3
;SEVCONFIELD OBJECT=EVENT_COUNTER
;SEVCONFIELD SECTION=EventLog
;SEVCONFIELD CATEGORY=LOGGING
[4203sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[4203sub1]
ParameterName=Event ID
ParameterValue=0x51c2
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=logging.ev_ctrs[2].mask
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4203sub2]
ParameterName=First Event Hours
ParameterValue=0x0016
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4203sub3]
ParameterName=First Event Minutes / Seconds
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4203sub4]
ParameterName=Last Event Hours
ParameterValue=0x0016
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4203sub5]
ParameterName=Last Event Minutes / Seconds
ParameterValue=0x15
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4203sub6]
ParameterName=Counter
ParameterValue=0x0002
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
[4204]
SubNumber=7
ObjectType=9
ParameterName=Other Event Counter 4
;SEVCONFIELD OBJECT=EVENT_COUNTER
;SEVCONFIELD SECTION=EventLog
;SEVCONFIELD CATEGORY=LOGGING
[4204sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[4204sub1]
ParameterName=Event ID
ParameterValue=0x4f41
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=logging.ev_ctrs[3].mask
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4204sub2]
ParameterName=First Event Hours
ParameterValue=0x001e
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4204sub3]
ParameterName=First Event Minutes / Seconds
ParameterValue=0x38
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4204sub4]
ParameterName=Last Event Hours
ParameterValue=0x002f
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4204sub5]
ParameterName=Last Event Minutes / Seconds
ParameterValue=0xec
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4204sub6]
ParameterName=Counter
ParameterValue=0x0009
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
[4205]
SubNumber=7
ObjectType=9
ParameterName=Other Event Counter 5
;SEVCONFIELD OBJECT=EVENT_COUNTER
;SEVCONFIELD SECTION=EventLog
;SEVCONFIELD CATEGORY=LOGGING
[4205sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[4205sub1]
ParameterName=Event ID
ParameterValue=0x52c4
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=logging.ev_ctrs[4].mask
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4205sub2]
ParameterName=First Event Hours
ParameterValue=0x0007
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4205sub3]
ParameterName=First Event Minutes / Seconds
ParameterValue=0x18
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4205sub4]
ParameterName=Last Event Hours
ParameterValue=0x0007
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4205sub5]
ParameterName=Last Event Minutes / Seconds
ParameterValue=0x19
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4205sub6]
ParameterName=Counter
ParameterValue=0x0002
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
[4206]
SubNumber=7
ObjectType=9
ParameterName=Other Event Counter 6
;SEVCONFIELD OBJECT=EVENT_COUNTER
;SEVCONFIELD SECTION=EventLog
;SEVCONFIELD CATEGORY=LOGGING
[4206sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[4206sub1]
ParameterName=Event ID
ParameterValue=0x5044
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=logging.ev_ctrs[5].mask
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4206sub2]
ParameterName=First Event Hours
ParameterValue=0x0001
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4206sub3]
ParameterName=First Event Minutes / Seconds
ParameterValue=0xa9
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4206sub4]
ParameterName=Last Event Hours
ParameterValue=0x0030
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4206sub5]
ParameterName=Last Event Minutes / Seconds
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4206sub6]
ParameterName=Counter
ParameterValue=0x0041
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
[4207]
SubNumber=7
ObjectType=9
ParameterName=Other Event Counter 7
;SEVCONFIELD OBJECT=EVENT_COUNTER
;SEVCONFIELD SECTION=EventLog
;SEVCONFIELD CATEGORY=LOGGING
[4207sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[4207sub1]
ParameterName=Event ID
ParameterValue=0x54c1
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=logging.ev_ctrs[6].mask
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4207sub2]
ParameterName=First Event Hours
ParameterValue=0x0018
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4207sub3]
ParameterName=First Event Minutes / Seconds
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4207sub4]
ParameterName=Last Event Hours
ParameterValue=0x001a
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4207sub5]
ParameterName=Last Event Minutes / Seconds
ParameterValue=0xc7
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4207sub6]
ParameterName=Counter
ParameterValue=0x0002
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
[4208]
SubNumber=7
ObjectType=9
ParameterName=Other Event Counter 8
;SEVCONFIELD OBJECT=EVENT_COUNTER
;SEVCONFIELD SECTION=EventLog
;SEVCONFIELD CATEGORY=LOGGING
[4208sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[4208sub1]
ParameterName=Event ID
ParameterValue=0x3441
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=logging.ev_ctrs[7].mask
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4208sub2]
ParameterName=First Event Hours
ParameterValue=0x0007
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4208sub3]
ParameterName=First Event Minutes / Seconds
ParameterValue=0x18
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4208sub4]
ParameterName=Last Event Hours
ParameterValue=0x001a
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4208sub5]
ParameterName=Last Event Minutes / Seconds
ParameterValue=0x61
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4208sub6]
ParameterName=Counter
ParameterValue=0x000a
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
[4209]
SubNumber=7
ObjectType=9
ParameterName=Other Event Counter 9
;SEVCONFIELD OBJECT=EVENT_COUNTER
;SEVCONFIELD SECTION=EventLog
;SEVCONFIELD CATEGORY=LOGGING
[4209sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[4209sub1]
ParameterName=Event ID
ParameterValue=0x4f55
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=logging.ev_ctrs[8].mask
;SEVCONFIELD NUMBER_FORMAT=BASE16
[4209sub2]
ParameterName=First Event Hours
ParameterValue=0x0020
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4209sub3]
ParameterName=First Event Minutes / Seconds
ParameterValue=0x61
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4209sub4]
ParameterName=Last Event Hours
ParameterValue=0x0020
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[4209sub5]
ParameterName=Last Event Minutes / Seconds
ParameterValue=0x61
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4209sub6]
ParameterName=Counter
ParameterValue=0x0001
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
[420A]
SubNumber=7
ObjectType=9
ParameterName=Other Event Counter 10
;SEVCONFIELD OBJECT=EVENT_COUNTER
;SEVCONFIELD SECTION=EventLog
;SEVCONFIELD CATEGORY=LOGGING
[420Asub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[420Asub1]
ParameterName=Event ID
ParameterValue=0x5043
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD EEPROM=logging.ev_ctrs[9].mask
;SEVCONFIELD NUMBER_FORMAT=BASE16
[420Asub2]
ParameterName=First Event Hours
ParameterValue=0x0007
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[420Asub3]
ParameterName=First Event Minutes / Seconds
ParameterValue=0x18
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[420Asub4]
ParameterName=Last Event Hours
ParameterValue=0x0030
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD UNITS=Hours
[420Asub5]
ParameterName=Last Event Minutes / Seconds
ParameterValue=0x24
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xEf
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[420Asub6]
ParameterName=Counter
ParameterValue=0x001f
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
[4300]
SubNumber=14
ObjectType=9
ParameterName=Operational Monitor - Customer Copy
;SEVCONFIELD OBJECT=CUST_OPERATIONAL_MONITOR
;SEVCONFIELD SECTION=OperationalLog
;SEVCONFIELD CATEGORY=LOGGING
[4300sub0]
ParameterName=Number of entries
ParameterValue=0x0d
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=13
;SEVCONFIELD OBJECT_VERSION=1
[4300sub1]
ParameterName=Reset
ObjectType=7
DataType=1
AccessType=wo
LowLimit=0
HighLimit=1
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Reset
;SEVCONFIELD 1=Reset
[4300sub2]
ParameterName=Minimum Battery Voltage
ParameterValue=0x0278
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
[4300sub3]
ParameterName=Maximum Battery Voltage
ParameterValue=0x0668
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
[4300sub4]
ParameterName=Minimum Capacitor Voltage
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
[4300sub5]
ParameterName=Maximum Capacitor Voltage
ParameterValue=0x0658
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
[4300sub6]
ParameterName=Minimum Motor Current 1
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=A(RMS)
[4300sub7]
ParameterName=Maximum Motor Current 1
ParameterValue=0x02c8
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=A(RMS)
[4300sub8]
ParameterName=Minimum Motor Current 2
ParameterValue=0x7fff
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=A(RMS)
[4300sub9]
ParameterName=Maximum Motor Current 2
ParameterValue=0x8000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=A(RMS)
[4300subA]
ParameterName=Minimum Motor Speed
ParameterValue=0xf6ea
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=RPM
[4300subB]
ParameterName=Maximum Motor Speed
ParameterValue=0x116e
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=RPM
[4300subC]
ParameterName=Minimum Device Temperature
ParameterValue=0x0012
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=DegC
[4300subD]
ParameterName=Maximum Device Temperature
ParameterValue=0x0041
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=DegC
[4301]
SubNumber=14
ObjectType=9
ParameterName=Operational Monitor - Sevcon Copy
;SEVCONFIELD OBJECT=SEVCON_OPERATIONAL_MONITOR
;SEVCONFIELD SECTION=OperationalLog
;SEVCONFIELD CATEGORY=LOGGING
[4301sub0]
ParameterName=Number of entries
ParameterValue=0x0d
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=13
;SEVCONFIELD OBJECT_VERSION=1
[4301sub1]
ParameterName=Reset
ObjectType=7
DataType=1
AccessType=wo
LowLimit=0
HighLimit=1
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=5
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Reset
;SEVCONFIELD 1=Reset
[4301sub2]
ParameterName=Minimum Battery Voltage
ParameterValue=0x0288
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
[4301sub3]
ParameterName=Maximum Battery Voltage
ParameterValue=0x0650
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
[4301sub4]
ParameterName=Minimum Capacitor Voltage
ParameterValue=0x0076
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
[4301sub5]
ParameterName=Maximum Capacitor Voltage
ParameterValue=0x065f
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
[4301sub6]
ParameterName=Minimum Motor Current 1
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=A(RMS)
[4301sub7]
ParameterName=Maximum Motor Current 1
ParameterValue=0x0240
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=A(RMS)
[4301sub8]
ParameterName=Minimum Motor Current 2
ParameterValue=0x7fff
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=A(RMS)
[4301sub9]
ParameterName=Maximum Motor Current 2
ParameterValue=0x8000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=A(RMS)
[4301subA]
ParameterName=Minimum Motor Speed
ParameterValue=0xf6ea
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=RPM
[4301subB]
ParameterName=Maximum Motor Speed
ParameterValue=0x116e
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=RPM
[4301subC]
ParameterName=Minimum Device Temperature
ParameterValue=0x0012
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=DegC
[4301subD]
ParameterName=Maximum Device Temperature
ParameterValue=0x0040
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=DegC
[4600]
SubNumber=16
ObjectType=9
ParameterName=Additional Motor Measurements
;SEVCONFIELD OBJECT=ADD_MOTOR_STATUS
;SEVCONFIELD SECTION=Motor1Status
;SEVCONFIELD CATEGORY=MONITORING
[4600sub0]
ParameterName=Number of entries
ParameterValue=0x10
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=18
;SEVCONFIELD OBJECT_VERSION=1
[4600sub1]
ParameterName=Slip Frequency
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=2.45436926061703E-02
;SEVCONFIELD UNITS=rads/s
[4600sub3]
ParameterName=Temperature (Measured - PTC)
ParameterValue=0x0015
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-50
HighLimit=250
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=DegC
[4600sub4]
ParameterName=Temperature (Measured - Switch)
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=ro
LowLimit=0
HighLimit=1
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Motor OK
;SEVCONFIELD 1=Motor Too Hot
[4600sub5]
ParameterName=Target Id (If)
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32000
HighLimit=32000
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A
[4600sub6]
ParameterName=Target Iq (Ia)
ParameterValue=0xffff
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32000
HighLimit=32000
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A
[4600sub7]
ParameterName=Id (If)
ParameterValue=0xfff9
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A
[4600sub8]
ParameterName=Iq (Ia)
ParameterValue=0x0001
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A
[4600sub9]
ParameterName=Ud (Uf)
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-3200
HighLimit=3200
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
[4600subA]
ParameterName=Uq (Ua)
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-3200
HighLimit=3200
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
[4600subB]
ParameterName=Voltage modulation
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=255
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.392156862745098
;SEVCONFIELD UNITS=%
[4600subC]
ParameterName=Actual AC Motor Current
ParameterValue=0x0001
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=A
[4600subD]
ParameterName=Actual AC Motor Voltage
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
[4600subE]
ParameterName=Motor velocity for 2nd motor
ParameterValue=0x00000000
ObjectType=7
DataType=4
AccessType=ro
LowLimit=-20000
HighLimit=20000
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=RPM
[4600subF]
ParameterName=Electrical output frequency
ParameterValue=0xffff
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-2048
HighLimit=2047
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=rads/s
[4600sub10]
ParameterName=Temperature (Measured - Remote)
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-50
HighLimit=250
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=DegC
[4601]
SubNumber=3
ObjectType=9
ParameterName=Pulsing Hours Counter
;SEVCONFIELD OBJECT=PULSING_HOURS
;SEVCONFIELD SECTION=HoursCounters
;SEVCONFIELD CATEGORY=LOGGING
[4601sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[4601sub1]
ParameterName=Hours
ParameterValue=0x0001
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=Hours
[4601sub2]
ParameterName=Minutes / Seconds
ParameterValue=0xc8
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xEf
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[4602]
SubNumber=25
ObjectType=9
ParameterName=AC Motor Debug Information
;SEVCONFIELD OBJECT=MOTOR_DEBUG
;SEVCONFIELD SECTION=Motor1Debug
;SEVCONFIELD CATEGORY=MONITORING
[4602sub0]
ParameterName=Number of entries
ParameterValue=0x23
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=45
;SEVCONFIELD OBJECT_VERSION=1
[4602sub1]
ParameterName=Motor Temperature/Torque Cutback (DWork.Tj_cutback_factor)
ParameterValue=0x0100
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=65535
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
[4602sub2]
ParameterName=Junction Temperature 1 (DWork.Tj[0])
ParameterValue=0x0016
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=DegC
[4602sub3]
ParameterName=Junction Temperature 2 (DWork.Tj[1])
ParameterValue=0x0016
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=DegC
[4602sub4]
ParameterName=Junction Temperature 3 (DWork.Tj[2])
ParameterValue=0x0016
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=DegC
[4602sub5]
ParameterName=Junction Temperature 4 (DWork.Tj[3])
ParameterValue=0x0016
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=DegC
[4602sub6]
ParameterName=Junction Temperature 5 (DWork.Tj[4])
ParameterValue=0x0016
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=DegC
[4602sub7]
ParameterName=Junction Temperature 6 (DWork.Tj[5])
ParameterValue=0x0016
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=DegC
[4602sub8]
ParameterName=Motor Temperature Estimate (DWork.T_motor)
ParameterValue=0x0016
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=DegC
[4602sub9]
ParameterName=Heatsink Temperature (U.DSP_Ts)
ParameterValue=0x16
ObjectType=7
DataType=2
AccessType=ro
LowLimit=-128
HighLimit=127
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=DegC
[4602subA]
ParameterName=Overall DSP Maximum Motor Temperature (Y.Temp_max)
ParameterValue=0x004d
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=DegC
[4602subB]
ParameterName=Torque demand value (U.T_d)
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=Nm
[4602subC]
ParameterName=Torque actual value (DWork.Td)
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=Nm
[4602subD]
ParameterName=Maximum torque (DWork.Td_max)
ParameterValue=0x055e
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=Nm
[4602subE]
ParameterName=Maximum power limit torque (Y.T_power_limit)
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=Nm
[4602subF]
ParameterName=Trip Voltage (DWork.Vtrip)
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=65535
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
[4602sub10]
ParameterName=Drive torque voltage cutback factor
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=65535
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.000030517578125
[4602sub11]
ParameterName=Battery Voltage
ParameterValue=0x0551
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=65535
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
[4602sub12]
ParameterName=Capacitor Voltage
ParameterValue=0x00ac
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=65535
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
[4602sub13]
ParameterName=Capacitor short term temperature estimate
ParameterValue=0x0015
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=65535
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=DegC
[4602sub14]
ParameterName=PCB Track Temperature Estimate
ParameterValue=0x0016
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-32768
HighLimit=32767
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=DegC
[4602sub15]
ParameterName=Capacitor long term temperature estimate
ParameterValue=0x0015
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=65535
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=DegC
[4602sub16]
ParameterName=Current sensor autozero value (M1)
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=65535
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A
[4602sub17]
ParameterName=Current sensor autozero value (M2)
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0
HighLimit=65535
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A
[4602sub23]
ParameterName=Encoder debug flags
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=65535
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
[4603]
SubNumber=2
ObjectType=9
ParameterName=Additional Motor 2 Measurements
;SEVCONFIELD OBJECT=ADD_MOTOR_STATUS
;SEVCONFIELD SECTION=Motor1Status
;SEVCONFIELD CATEGORY=MONITORING
[4603sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[4603sub1]
ParameterName=Temperature (Measured - PTC)
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=-50
HighLimit=250
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=DegC
[4610]
SubNumber=19
ObjectType=9
ParameterName=Id factor map
;SEVCONFIELD OBJECT=MOTOR_FLUX_MAP
;SEVCONFIELD SECTION=MOTOR1CHARACTERIZATION
;SEVCONFIELD CATEGORY=CONFIGURATION
[4610sub0]
ParameterName=Number of entries
ParameterValue=0x12
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=18
;SEVCONFIELD OBJECT_VERSION=2
[4610sub1]
ParameterName=Pt 1 Slip
ParameterValue=0xfff0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=65520
HighLimit=65520
PDOMapping=0
DefaultValue=0x0000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=p.u. slip
;SEVCONFIELD EEPROM=motor_0.flux_map[0].x
[4610sub2]
ParameterName=Pt 1 Id factor
ParameterValue=0x0040
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.015625
;SEVCONFIELD UNITS=p.u. Id
;SEVCONFIELD EEPROM=motor_0.flux_map[0].y
[4610sub3]
ParameterName=Pt 2 Slip
ParameterValue=0xffc0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0x0002
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=p.u. slip
;SEVCONFIELD EEPROM=motor_0.flux_map[1].x
[4610sub4]
ParameterName=Pt 2 Id factor
ParameterValue=0x0030
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.015625
;SEVCONFIELD UNITS=p.u. Id
;SEVCONFIELD EEPROM=motor_0.flux_map[1].y
[4610sub5]
ParameterName=Pt 3 Slip
ParameterValue=0xffd0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0x0004
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=p.u. slip
;SEVCONFIELD EEPROM=motor_0.flux_map[2].x
[4610sub6]
ParameterName=Pt 3 Id factor
ParameterValue=0x0020
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.015625
;SEVCONFIELD UNITS=p.u. Id
;SEVCONFIELD EEPROM=motor_0.flux_map[2].y
[4610sub7]
ParameterName=Pt 4 Slip
ParameterValue=0xffe8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0x0006
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=p.u. slip
;SEVCONFIELD EEPROM=motor_0.flux_map[3].x
[4610sub8]
ParameterName=Pt 4 Id factor
ParameterValue=0x0010
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.015625
;SEVCONFIELD UNITS=p.u. Id
;SEVCONFIELD EEPROM=motor_0.flux_map[3].y
[4610sub9]
ParameterName=Pt 5 Slip
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0x0008
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=p.u. slip
;SEVCONFIELD EEPROM=motor_0.flux_map[4].x
[4610subA]
ParameterName=Pt 5 Id factor
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.015625
;SEVCONFIELD UNITS=p.u. Id
;SEVCONFIELD EEPROM=motor_0.flux_map[4].y
[4610subB]
ParameterName=Pt 6 Slip
ParameterValue=0x0018
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0x000a
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=p.u. slip
;SEVCONFIELD EEPROM=motor_0.flux_map[5].x
[4610subC]
ParameterName=Pt 6 Id factor
ParameterValue=0x0010
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.015625
;SEVCONFIELD UNITS=p.u. Id
;SEVCONFIELD EEPROM=motor_0.flux_map[5].y
[4610subD]
ParameterName=Pt 7 Slip
ParameterValue=0x0030
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0x000c
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=p.u. slip
;SEVCONFIELD EEPROM=motor_0.flux_map[6].x
[4610subE]
ParameterName=Pt 7 Id factor
ParameterValue=0x0020
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.015625
;SEVCONFIELD UNITS=p.u. Id
;SEVCONFIELD EEPROM=motor_0.flux_map[6].y
[4610subF]
ParameterName=Pt 8 Slip
ParameterValue=0x0040
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0x000e
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=p.u. slip
;SEVCONFIELD EEPROM=motor_0.flux_map[7].x
[4610sub10]
ParameterName=Pt 8 Id factor
ParameterValue=0x0030
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.015625
;SEVCONFIELD UNITS=p.u. Id
;SEVCONFIELD EEPROM=motor_0.flux_map[7].y
[4610sub11]
ParameterName=Pt 9 Slip
ParameterValue=0x0010
ObjectType=7
DataType=6
AccessType=rw
LowLimit=16
HighLimit=16
PDOMapping=0
DefaultValue=0x0010
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=p.u. slip
;SEVCONFIELD EEPROM=motor_0.flux_map[8].x
[4610sub12]
ParameterName=Pt 9 Id factor
ParameterValue=0x0040
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.015625
;SEVCONFIELD UNITS=p.u. Id
;SEVCONFIELD EEPROM=motor_0.flux_map[8].y
[4611]
SubNumber=19
ObjectType=9
ParameterName=Motor max slip map
;SEVCONFIELD OBJECT=MOTOR_POWER_LIMIT_MAP
;SEVCONFIELD SECTION=MOTOR1CHARACTERIZATION
;SEVCONFIELD CATEGORY=CONFIGURATION
[4611sub0]
ParameterName=Number of entries
ParameterValue=0x12
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=18
;SEVCONFIELD OBJECT_VERSION=2
[4611sub1]
ParameterName=Pt 1 Max Slip
ParameterValue=0x0780
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=160
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=rad/s
;SEVCONFIELD EEPROM=motor_0.power_map[0].x
[4611sub2]
ParameterName=Pt 1 Speed
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=motor_0.power_map[0].y
;SEVCONFIELD SOFT_HIGH=65535
[4611sub3]
ParameterName=Pt 2 Max Slip
ParameterValue=0x0780
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=160
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=rad/s
;SEVCONFIELD EEPROM=motor_0.power_map[1].x
[4611sub4]
ParameterName=Pt 2 Speed
ParameterValue=0x01f4
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=motor_0.power_map[1].y
;SEVCONFIELD SOFT_HIGH=65535
[4611sub5]
ParameterName=Pt 3 Max Slip
ParameterValue=0x0780
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=320
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=rad/s
;SEVCONFIELD EEPROM=motor_0.power_map[2].x
[4611sub6]
ParameterName=Pt 3 Speed
ParameterValue=0x03e8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=2000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=motor_0.power_map[2].y
;SEVCONFIELD SOFT_HIGH=65535
[4611sub7]
ParameterName=Pt 4 Max Slip
ParameterValue=0x0780
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=480
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=rad/s
;SEVCONFIELD EEPROM=motor_0.power_map[3].x
[4611sub8]
ParameterName=Pt 4 Speed
ParameterValue=0x07d0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=3000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=motor_0.power_map[3].y
;SEVCONFIELD SOFT_HIGH=65535
[4611sub9]
ParameterName=Pt 5 Max Slip
ParameterValue=0x0780
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=480
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=rad/s
;SEVCONFIELD EEPROM=motor_0.power_map[4].x
[4611subA]
ParameterName=Pt 5 Speed
ParameterValue=0x0bb8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=4000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=motor_0.power_map[4].y
;SEVCONFIELD SOFT_HIGH=65535
[4611subB]
ParameterName=Pt 6 Max Slip
ParameterValue=0x0780
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=480
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=rad/s
;SEVCONFIELD EEPROM=motor_0.power_map[5].x
[4611subC]
ParameterName=Pt 6 Speed
ParameterValue=0x0fa0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=5000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=motor_0.power_map[5].y
;SEVCONFIELD SOFT_HIGH=65535
[4611subD]
ParameterName=Pt 7 Max Slip
ParameterValue=0x0780
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=480
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=rad/s
;SEVCONFIELD EEPROM=motor_0.power_map[6].x
[4611subE]
ParameterName=Pt 7 Speed
ParameterValue=0x1388
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=6000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=motor_0.power_map[6].y
;SEVCONFIELD SOFT_HIGH=65535
[4611subF]
ParameterName=Pt 8 Max Slip
ParameterValue=0x0780
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=480
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=rad/s
;SEVCONFIELD EEPROM=motor_0.power_map[7].x
[4611sub10]
ParameterName=Pt 8 Speed
ParameterValue=0x1770
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=7000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=motor_0.power_map[7].y
;SEVCONFIELD SOFT_HIGH=65535
[4611sub11]
ParameterName=Pt 9 Max Slip
ParameterValue=0x0780
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=480
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=rad/s
;SEVCONFIELD EEPROM=motor_0.power_map[8].x
[4611sub12]
ParameterName=Pt 9 Speed
ParameterValue=0x1b58
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=8000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=RPM
;SEVCONFIELD EEPROM=motor_0.power_map[8].y
;SEVCONFIELD SOFT_HIGH=65535
[4612]
SubNumber=19
ObjectType=9
ParameterName=Voltage Torque-Cutback Map
;SEVCONFIELD OBJECT=VOLTAGE_TRQ_CUTBACK_MAP
;SEVCONFIELD SECTION=MOTOR1CHARACTERIZATION
;SEVCONFIELD CATEGORY=CONFIGURATION
[4612sub0]
ParameterName=Number of entries
ParameterValue=0x12
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=18
;SEVCONFIELD OBJECT_VERSION=1
[4612sub1]
ParameterName=Pt 1 Voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=motor_0.torque_cutback[0].x
[4612sub2]
ParameterName=Pt 1 Voltage Cutback Gain
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0000305175781
;SEVCONFIELD EEPROM=motor_0.torque_cutback[0].y
;SEVCONFIELD SOFT_HIGH=65535
[4612sub3]
ParameterName=Pt 2 Voltage
ParameterValue=0x0240
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=1382
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=motor_0.torque_cutback[1].x
[4612sub4]
ParameterName=Pt 2 Voltage Cutback Gain
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0000305175781
;SEVCONFIELD EEPROM=motor_0.torque_cutback[1].y
;SEVCONFIELD SOFT_HIGH=65535
[4612sub5]
ParameterName=Pt 3 Voltage
ParameterValue=0x0280
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=2304
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=motor_0.torque_cutback[2].x
[4612sub6]
ParameterName=Pt 3 Voltage Cutback Gain
ParameterValue=0x7ffc
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0000305175781
;SEVCONFIELD EEPROM=motor_0.torque_cutback[2].y
;SEVCONFIELD SOFT_HIGH=65535
[4612sub7]
ParameterName=Pt 4 Voltage
ParameterValue=0x0640
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=3840
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=motor_0.torque_cutback[3].x
[4612sub8]
ParameterName=Pt 4 Voltage Cutback Gain
ParameterValue=0x7ffc
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=32767
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0000305175781
;SEVCONFIELD EEPROM=motor_0.torque_cutback[3].y
;SEVCONFIELD SOFT_HIGH=65535
[4612sub9]
ParameterName=Pt 5 Voltage
ParameterValue=0x0740
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=4454
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=motor_0.torque_cutback[4].x
[4612subA]
ParameterName=Pt 5 Voltage Cutback Gain
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0000305175781
;SEVCONFIELD EEPROM=motor_0.torque_cutback[4].y
;SEVCONFIELD SOFT_HIGH=65535
[4612subB]
ParameterName=Pt 6 Voltage
ParameterValue=0x0740
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=4454
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=motor_0.torque_cutback[5].x
[4612subC]
ParameterName=Pt 6 Voltage Cutback Gain
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0000305175781
;SEVCONFIELD EEPROM=motor_0.torque_cutback[5].y
;SEVCONFIELD SOFT_HIGH=65535
[4612subD]
ParameterName=Pt 7 Voltage
ParameterValue=0x0740
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=4454
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=motor_0.torque_cutback[6].x
[4612subE]
ParameterName=Pt 7 Voltage Cutback Gain
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0000305175781
;SEVCONFIELD EEPROM=motor_0.torque_cutback[6].y
;SEVCONFIELD SOFT_HIGH=65535
[4612subF]
ParameterName=Pt 8 Voltage
ParameterValue=0x0740
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=4454
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=motor_0.torque_cutback[7].x
[4612sub10]
ParameterName=Pt 8 Voltage Cutback Gain
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0000305175781
;SEVCONFIELD EEPROM=motor_0.torque_cutback[7].y
;SEVCONFIELD SOFT_HIGH=65535
[4612sub11]
ParameterName=Pt 9 Voltage
ParameterValue=0x0740
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=4454
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=motor_0.torque_cutback[8].x
[4612sub12]
ParameterName=Pt 9 Voltage Cutback Gain
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x7FFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0000305175781
;SEVCONFIELD EEPROM=motor_0.torque_cutback[8].y
;SEVCONFIELD SOFT_HIGH=65535
[4614]
SubNumber=19
ObjectType=9
ParameterName=Im/Lm Saturation Map
;SEVCONFIELD OBJECT=IMLM_SATURATION_MAP
;SEVCONFIELD SECTION=MOTOR1CHARACTERIZATION
;SEVCONFIELD CATEGORY=CONFIGURATION
[4614sub0]
ParameterName=Number of entries
ParameterValue=0x12
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=18
;SEVCONFIELD OBJECT_VERSION=1
[4614sub1]
ParameterName=Pt 1 Mag Current
ParameterValue=0x0149
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A(RMS)
;SEVCONFIELD EEPROM=misc.saturation_map[0].x
[4614sub2]
ParameterName=Pt 1 Mag Inductance
ParameterValue=0x11c3
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=4587
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000244141
;SEVCONFIELD UNITS=puH
;SEVCONFIELD EEPROM=misc.saturation_map[0].y
;SEVCONFIELD SOFT_HIGH=65535
[4614sub3]
ParameterName=Pt 2 Mag Current
ParameterValue=0x0226
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=500
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A(RMS)
;SEVCONFIELD EEPROM=misc.saturation_map[1].x
[4614sub4]
ParameterName=Pt 2 Mag Inductance
ParameterValue=0x1152
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=4301
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000244141
;SEVCONFIELD UNITS=puH
;SEVCONFIELD EEPROM=misc.saturation_map[1].y
;SEVCONFIELD SOFT_HIGH=65535
[4614sub5]
ParameterName=Pt 3 Mag Current
ParameterValue=0x0303
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A(RMS)
;SEVCONFIELD EEPROM=misc.saturation_map[2].x
[4614sub6]
ParameterName=Pt 3 Mag Inductance
ParameterValue=0x0fa2
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=3840
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000244141
;SEVCONFIELD UNITS=puH
;SEVCONFIELD EEPROM=misc.saturation_map[2].y
;SEVCONFIELD SOFT_HIGH=65535
[4614sub7]
ParameterName=Pt 4 Mag Current
ParameterValue=0x03e0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=1499
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A(RMS)
;SEVCONFIELD EEPROM=misc.saturation_map[3].x
[4614sub8]
ParameterName=Pt 4 Mag Inductance
ParameterValue=0x0d9f
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=3194
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000244141
;SEVCONFIELD UNITS=puH
;SEVCONFIELD EEPROM=misc.saturation_map[3].y
;SEVCONFIELD SOFT_HIGH=65535
[4614sub9]
ParameterName=Pt 5 Mag Current
ParameterValue=0x04be
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=1600
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A(RMS)
;SEVCONFIELD EEPROM=misc.saturation_map[4].x
[4614subA]
ParameterName=Pt 5 Mag Inductance
ParameterValue=0x0bec
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=3030
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000244141
;SEVCONFIELD UNITS=puH
;SEVCONFIELD EEPROM=misc.saturation_map[4].y
;SEVCONFIELD SOFT_HIGH=65535
[4614subB]
ParameterName=Pt 6 Mag Current
ParameterValue=0x059b
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=2100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A(RMS)
;SEVCONFIELD EEPROM=misc.saturation_map[5].x
[4614subC]
ParameterName=Pt 6 Mag Inductance
ParameterValue=0x0a91
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=2539
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000244141
;SEVCONFIELD UNITS=puH
;SEVCONFIELD EEPROM=misc.saturation_map[5].y
;SEVCONFIELD SOFT_HIGH=65535
[4614subD]
ParameterName=Pt 7 Mag Current
ParameterValue=0x0678
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=2400
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A(RMS)
;SEVCONFIELD EEPROM=misc.saturation_map[6].x
[4614subE]
ParameterName=Pt 7 Mag Inductance
ParameterValue=0x097c
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=2334
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000244141
;SEVCONFIELD UNITS=puH
;SEVCONFIELD EEPROM=misc.saturation_map[6].y
;SEVCONFIELD SOFT_HIGH=65535
[4614subF]
ParameterName=Pt 8 Mag Current
ParameterValue=0x0755
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=3200
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A(RMS)
;SEVCONFIELD EEPROM=misc.saturation_map[7].x
[4614sub10]
ParameterName=Pt 8 Mag Inductance
ParameterValue=0x089b
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=1884
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000244141
;SEVCONFIELD UNITS=puH
;SEVCONFIELD EEPROM=misc.saturation_map[7].y
;SEVCONFIELD SOFT_HIGH=65535
[4614sub11]
ParameterName=Pt 9 Mag Current
ParameterValue=0x0832
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=4000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A(RMS)
;SEVCONFIELD EEPROM=misc.saturation_map[8].x
[4614sub12]
ParameterName=Pt 9 Mag Inductance
ParameterValue=0x07e3
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=1556
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000244141
;SEVCONFIELD UNITS=puH
;SEVCONFIELD EEPROM=misc.saturation_map[8].y
;SEVCONFIELD SOFT_HIGH=65535
[4620]
SubNumber=8
ObjectType=9
ParameterName=Motor Temperature Sensor
;SEVCONFIELD OBJECT=ALG_IN_MOTOR_TEMP
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD CATEGORY=CONFIGURATION
[4620sub0]
ParameterName=Number of entries
ParameterValue=0x07
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=8
;SEVCONFIELD OBJECT_VERSION=1
[4620sub1]
ParameterName=Mode
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=3
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=motor_0.temp_meas_mode
;SEVCONFIELD NUMBER_FORMAT=5
;SEVCONFIELD 0=None
;SEVCONFIELD 1=PTC
;SEVCONFIELD 2=Switch
;SEVCONFIELD 3=PTC and Switch
;SEVCONFIELD 4=Remote
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4620sub2]
ParameterName=High Temperature Voltage (PTC)
ParameterValue=0x11c0
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=motor_0.temp_meas_high_temp_voltage
[4620sub3]
ParameterName=Low Temperature Voltage (PTC)
ParameterValue=0x0b00
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=motor_0.temp_meas_low_temp_voltage
[4620sub4]
ParameterName=Switch source
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=motor_0.temp_meas_switch_source
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4620sub5]
ParameterName=PTC type
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=2
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD NUMBER_FORMAT=3
;SEVCONFIELD 0=User Defined
;SEVCONFIELD 1=KTY84
;SEVCONFIELD 2=KTY83
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4620sub6]
ParameterName=Failure torque cutback rate
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=1
HighLimit=19200
PDOMapping=0
DefaultValue=1920
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=s
[4620sub7]
ParameterName=Failure torque recovery rate
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=1
HighLimit=19200
PDOMapping=0
DefaultValue=80
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=s
[4621]
SubNumber=8
ObjectType=9
ParameterName=Motor Temperature Setup
;SEVCONFIELD OBJECT=MOTOR_TEMP_LIMIT
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD CATEGORY=CONFIGURATION
[4621sub0]
ParameterName=Number of entries
ParameterValue=0x07
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=7
;SEVCONFIELD OBJECT_VERSION=1
[4621sub1]
ParameterName=Motor temperature estimate current constant
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=0x0078
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.5
;SEVCONFIELD EEPROM=motor_0.temp_meas_i_const
[4621sub2]
ParameterName=Motor temperature estimate discretization
ParameterValue=0x7fff
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32767
PDOMapping=0
DefaultValue=0x7F4B
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=motor_0.temp_meas_discretisation
[4621sub3]
ParameterName=Maximum allowable motor temperature
ParameterValue=0x0078
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32768
PDOMapping=0
DefaultValue=0x005A
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=DegC
;SEVCONFIELD EEPROM=motor_0.temp_meas_maximum
[4621sub4]
ParameterName=Rotor resistance variation hot temperature
ParameterValue=0x0064
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32768
PDOMapping=0
DefaultValue=140
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=DegC
[4621sub5]
ParameterName=Rotor resistance variation cold temperature
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=-32768
HighLimit=32768
PDOMapping=0
DefaultValue=-40
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=DegC
[4621sub6]
ParameterName=Rotor resistance variation hot factor
ParameterValue=0x0100
ObjectType=7
DataType=3
AccessType=rw
LowLimit=64
HighLimit=1024
PDOMapping=0
DefaultValue=0x0100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
[4621sub7]
ParameterName=Rotor resistance variation cold factor
ParameterValue=0x0100
ObjectType=7
DataType=3
AccessType=rw
LowLimit=64
HighLimit=1024
PDOMapping=0
DefaultValue=0x0100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
[4623]
SubNumber=5
ObjectType=9
ParameterName=Battery current limit
;SEVCONFIELD OBJECT=MOTOR_IBATT_CUTBACK
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD CATEGORY=CONFIGURATION
[4623sub0]
ParameterName=Number of entries
ParameterValue=0x04
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=4
;SEVCONFIELD OBJECT_VERSION=2
[4623sub1]
ParameterName=Maximum battery charge current
ParameterValue=0xff9c
ObjectType=7
DataType=3
AccessType=rww
LowLimit=-32768
HighLimit=0
PDOMapping=1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=A
[4623sub2]
ParameterName=Maximum battery discharge current
ParameterValue=0x0078
ObjectType=7
DataType=3
AccessType=rww
LowLimit=0
HighLimit=32767
PDOMapping=1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=A
[4623sub3]
ParameterName=Cutback range
ParameterValue=0x0014
ObjectType=7
DataType=3
AccessType=rw
LowLimit=0
HighLimit=0x7fff
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=A
[4623sub4]
ParameterName=Battery current estimation correction factor
ParameterValue=0x1000
ObjectType=7
DataType=3
AccessType=rw
LowLimit=2048
HighLimit=6144
PDOMapping=0
DefaultValue=0x1000
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000244140625
[4624]
ParameterName=Motor overspeed protection
ParameterValue=0x1b58
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=1000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=rpm
;SEVCONFIELD OBJECT=MOTOR_OVERSPEED_PROTECTION
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD CATEGORY=CONFIGURATION
[4630]
SubNumber=5
ObjectType=9
ParameterName=Encoder Configuration
;SEVCONFIELD OBJECT=ENCODER_PULLUP
;SEVCONFIELD SECTION=EncoderConfig
;SEVCONFIELD CATEGORY=CONFIGURATION
[4630sub0]
ParameterName=Number of entries
ParameterValue=0x04
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=19
;SEVCONFIELD OBJECT_VERSION=1
[4630sub1]
ParameterName=Encoder Pull Up
ParameterValue=0x01
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=motor_0.encoder_pullup
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4630sub2]
ParameterName=Encoder Supply
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=motor_0.encoder_supply
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=10V
;SEVCONFIELD 1=5V
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4630sub3]
ParameterName=Encoder Type
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD NUMBER_FORMAT=10
;SEVCONFIELD 0=AB only
;SEVCONFIELD 1=AB and UVW
;SEVCONFIELD 2=UVW only
;SEVCONFIELD 3=AB and UVW invert
;SEVCONFIELD 4=UVW invert only
;SEVCONFIELD 5=SIN/COS
;SEVCONFIELD 6=Single channel
;SEVCONFIELD 7=Single pole pair resolver
;SEVCONFIELD 8=Multi pole pair resolver
;SEVCONFIELD 9=Sensoless Mode
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4630sub4]
ParameterName=Encoder Offset
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=46080
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=Degrees
[4640]
SubNumber=7
ObjectType=9
ParameterName=Motor Nameplate Data
;SEVCONFIELD OBJECT=NAME_PLATE_DATA
;SEVCONFIELD SECTION=Motor1PlateData
;SEVCONFIELD CATEGORY=CONFIGURATION
[4640sub0]
ParameterName=Number of entries
ParameterValue=0x06
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=6
;SEVCONFIELD OBJECT_VERSION=1
[4640sub1]
ParameterName=Rated line voltage
ParameterValue=0x0280
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=Vrms
;SEVCONFIELD EEPROM=misc.nameplate_rated_line_volts
;SEVCONFIELD SOFT_HIGH=65535
[4640sub2]
ParameterName=Rated phase current
ParameterValue=0x0590
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=Arms
;SEVCONFIELD EEPROM=misc.nameplate_rated_phase_current
;SEVCONFIELD SOFT_HIGH=65535
[4640sub3]
ParameterName=Rated mechanical speed
ParameterValue=0x2710
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=rpm
;SEVCONFIELD EEPROM=misc.nameplate_rated_mech_speed
;SEVCONFIELD SOFT_HIGH=65535
[4640sub4]
ParameterName=Rated frequency
ParameterValue=0x03c0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=Hz
;SEVCONFIELD EEPROM=misc.nameplate_rated_elec_freq
;SEVCONFIELD SOFT_HIGH=65535
[4640sub5]
ParameterName=Rated power
ParameterValue=0x00b0
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=Kw
;SEVCONFIELD EEPROM=misc.nameplate_rated_power
;SEVCONFIELD SOFT_HIGH=65535
[4640sub6]
ParameterName=Power factor
ParameterValue=0x6e14
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000030517578125
;SEVCONFIELD UNITS=sin theta
;SEVCONFIELD EEPROM=misc.nameplate_power_factor
;SEVCONFIELD SOFT_HIGH=65535
[4641]
SubNumber=41
ObjectType=9
ParameterName=AC Motor data (manufacturer specific)
;SEVCONFIELD OBJECT=ESPAC_MOTOR_DATA
;SEVCONFIELD SECTION=Motor1PlateData
;SEVCONFIELD CATEGORY=CONFIGURATION
[4641sub0]
ParameterName=Number of entries
ParameterValue=0x2a
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=49
;SEVCONFIELD OBJECT_VERSION=1
[4641sub1]
ParameterName=Commit
ObjectType=7
DataType=1
AccessType=wo
LowLimit=0
HighLimit=1
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub2]
ParameterName=Maximum Stator Current (Is_max)
ParameterValue=0x0226
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=65535
PDOMapping=0
DefaultValue=300
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=A(RMS)
;SEVCONFIELD EEPROM=motor_0.max_stator_current
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub3]
ParameterName=Minimum Magnetizing Current (Im_min)
ParameterValue=0x0100
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=1958
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=A(RMS)
;SEVCONFIELD EEPROM=motor_0.min_flux_current
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub4]
ParameterName=Maximum Magnetizing/Direct Current (Id_max)
ParameterValue=0x4b00
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=65535
PDOMapping=0
DefaultValue=3917
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.015625
;SEVCONFIELD UNITS=A(RMS)
;SEVCONFIELD EEPROM=motor_0.max_flux_current
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub5]
ParameterName=Number of Pole Pairs (np)
ParameterValue=0x0002
ObjectType=7
DataType=6
AccessType=rw
LowLimit=1
HighLimit=66
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=motor_0.number_of_pole_pairs
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub6]
ParameterName=Stator Resistance (Rs)
ParameterValue=0x0015
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=65535
PDOMapping=0
DefaultValue=82
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.244140625
;SEVCONFIELD UNITS=mOhms
;SEVCONFIELD EEPROM=motor_0.stator_resistance
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub7]
ParameterName=Rated Stator Current
ParameterValue=0x010c
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=2000
PDOMapping=0
DefaultValue=172
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=A(RMS)
;SEVCONFIELD EEPROM=motor_0.rated_stator_i
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub8]
ParameterName=Rotor Resistance (Rr)
ParameterValue=0x0016
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=65535
PDOMapping=0
DefaultValue=41
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.244140625
;SEVCONFIELD UNITS=mOhms
;SEVCONFIELD EEPROM=motor_0.rotor_resistance
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub9]
ParameterName=Magnetizing Inductance (Lm)
ParameterValue=0x0057
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=65535
PDOMapping=0
DefaultValue=125
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=15.2587890625
;SEVCONFIELD UNITS=uH
;SEVCONFIELD EEPROM=motor_0.flux_inductance
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641subA]
ParameterName=Stator Leakage Inductance (Lls)
ParameterValue=0x0019
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=65535
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.95367431640625
;SEVCONFIELD UNITS=uH
;SEVCONFIELD EEPROM=motor_0.stator_leakage_inductance
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641subB]
ParameterName=Rotor Leakage Inductance (Llr)
ParameterValue=0x0019
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=65535
PDOMapping=0
DefaultValue=21800
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.95367431640625
;SEVCONFIELD UNITS=uH
;SEVCONFIELD EEPROM=motor_0.rotor_leakage_inductance
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641subC]
ParameterName=Nominal battery voltage
ParameterValue=0x0500
ObjectType=7
DataType=6
AccessType=rw
LowLimit=384
HighLimit=3072
PDOMapping=0
DefaultValue=768
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=motor_0.nom_bat_v
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641subD]
ParameterName=Current control proportional gain (Kp)
ParameterValue=0x1996
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=65535
PDOMapping=0
DefaultValue=22938
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000030517578125
;SEVCONFIELD EEPROM=motor_0.i_ctrl_gain
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641subF]
ParameterName=Current control integral gain
ParameterValue=0x051d
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=65535
PDOMapping=0
DefaultValue=28406
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000030517578125
;SEVCONFIELD EEPROM=motor_0.i_ctrl_discretisation
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub10]
ParameterName=Reactive Gain Boost
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=65535
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52587890625E-05
;SEVCONFIELD UNITS=Henry
;SEVCONFIELD EEPROM=motor_0.reactive_gain_boost
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub12]
ParameterName=Voltage Constant (Ke)
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=7864
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000030517578125
;SEVCONFIELD UNITS=V/rads (line, rms, elec_frq)
;SEVCONFIELD EEPROM=misc.pm_ke
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub13]
ParameterName=Im rated
ParameterValue=0x02d6
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=32000
PDOMapping=0
DefaultValue=160
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A
;SEVCONFIELD EEPROM=misc.motor_im_rated
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub14]
ParameterName=Low speed slip
ParameterValue=0x0008
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=500
PDOMapping=0
DefaultValue=30
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=rad/s
;SEVCONFIELD EEPROM=misc.motor_max_m_slip
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub15]
ParameterName=High speed slip
ParameterValue=0x0008
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=500
PDOMapping=0
DefaultValue=30
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=rad/s
;SEVCONFIELD EEPROM=misc.motor_max_g_slip
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub16]
ParameterName=Openloop start speed
ParameterValue=0x000a
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=3000
PDOMapping=0
DefaultValue=150
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=9.54929658551372
;SEVCONFIELD UNITS=rpm
;SEVCONFIELD EEPROM=misc.motor_openloop_on_speed
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub17]
ParameterName=Openloop exit speed
ParameterValue=0x0bb8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=3000
PDOMapping=0
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=9.54929658551372
;SEVCONFIELD UNITS=rpm
;SEVCONFIELD EEPROM=misc.motor_openloop_off_speed
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub18]
ParameterName=Frequency Slope
ParameterValue=0x03e8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub19]
ParameterName=Frequency/Mod index control Kp
ParameterValue=0x001a
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000030517578125
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub1A]
ParameterName=Frequency/Mod index control Ki
ParameterValue=0x00e6
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000030517578125
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub1B]
ParameterName=Slip control Kp
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000030517578125
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub1C]
ParameterName=Slip control Ki
ParameterValue=0x0300
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000030517578125
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub1D]
ParameterName=Slip control factor
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=256
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub1E]
ParameterName=Max drive mod index
ParameterValue=0x1000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x1000
PDOMapping=0
DefaultValue=3891
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0244140625
;SEVCONFIELD UNITS=%
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub1F]
ParameterName=Max brake mod index
ParameterValue=0x1000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x1000
PDOMapping=0
DefaultValue=3482
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0244140625
;SEVCONFIELD UNITS=%
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub20]
ParameterName=Ls/Ls'
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD EEPROM=misc.ls_over_ls1
[4641sub21]
ParameterName=Voltage Control Kp
ParameterValue=0x0ccd
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=8192
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000030517578125
;SEVCONFIELD EEPROM=misc.ac_mtr0_voltage_kp
[4641sub22]
ParameterName=Voltage Control Ki
ParameterValue=0x0100
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=4096
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000030517578125
;SEVCONFIELD EEPROM=misc.ac_mtr0_voltage_ki
[4641sub23]
ParameterName=start of Frequency cutback
ParameterValue=0x0d9a
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x1000
PDOMapping=0
DefaultValue=3481
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0244140625
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub24]
ParameterName=start of Voltage cutback
ParameterValue=0x0f33
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0x1000
PDOMapping=0
DefaultValue=3686
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0244140625
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub25]
ParameterName=Id recovery rate
ParameterValue=0x4e20
ObjectType=7
DataType=6
AccessType=rw
LowLimit=1
HighLimit=20000
PDOMapping=0
DefaultValue=20000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=A/s
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub26]
ParameterName=Ud stabilization factor (open loop slip)
ParameterValue=0x0400
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=512
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub27]
ParameterName=Iq_min factor (open loop slip)
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=64
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub28]
ParameterName=vf gain (open loop slip)
ParameterValue=0x0100
ObjectType=7
DataType=6
AccessType=rw
LowLimit=256
HighLimit=1280
PDOMapping=0
DefaultValue=512
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4641sub29]
ParameterName=Stored Rs estimation
ParameterValue=0x003f
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.244140625
;SEVCONFIELD UNITS=mOhms
[4641sub2A]
ParameterName=Iq_ref slew rate
ParameterValue=0x7fff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=800
HighLimit=32767
PDOMapping=0
DefaultValue=0x7FFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=A/s
;SEVCONFIELD EEPROM=misc.iq_ref_slew
[4650]
ParameterName=Miscellaneous DSP configuration
ParameterValue=0x0002
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD OBJECT=DSP_MISC_CONFIG
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD EEPROM=misc.dsp_config
;SEVCONFIELD CATEGORY=CONFIGURATION
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=15
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Encoder wire-off detection
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Enabled
;SEVCONFIELD 1=Disabled
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Software overcurrent
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Enabled
;SEVCONFIELD 1=Disabled
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Use low speed gains below
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=200rpm
;SEVCONFIELD 1=50rpm
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Sin-cos PLL (PMAC) / Closed loop slip compensation (IM)
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=Scale max torque by power limit
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Gain Scheduling
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=Allow drv/brk trq inhibit to 0 RPM
;SEVCONFIELD BITMASK=0x40
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=7
;SEVCONFIELD PARAMETERNAME=Motor open circuit detection
;SEVCONFIELD BITMASK=0x80
;SEVCONFIELD BITSHIFT=0x7
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=8
;SEVCONFIELD PARAMETERNAME=Speed dependent field weakening
;SEVCONFIELD BITMASK=0x100
;SEVCONFIELD BITSHIFT=0x8
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=9
;SEVCONFIELD PARAMETERNAME=Motor fault state (PMAC only)
;SEVCONFIELD BITMASK=0x200
;SEVCONFIELD BITSHIFT=0x9
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Open Circuit
;SEVCONFIELD 1=Short Circuit
;SEVCONFIELD SPLIT=10
;SEVCONFIELD PARAMETERNAME=Bypass DC link discharge at power on (PMAC Only)
;SEVCONFIELD BITMASK=0x400
;SEVCONFIELD BITSHIFT=0xA
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Discharge
;SEVCONFIELD 1=Bypass
;SEVCONFIELD SPLIT=11
;SEVCONFIELD PARAMETERNAME=Use lookup tables for demand (IMPM PMAC only)
;SEVCONFIELD BITMASK=0x800
;SEVCONFIELD BITSHIFT=0xB
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=12
;SEVCONFIELD PARAMETERNAME=Switching freq allowed to change to - reduce thermal losses (PMAC) / control low field currents (DC-SEM)
;SEVCONFIELD BITMASK=0x1000
;SEVCONFIELD BITSHIFT=0xC
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Yes
;SEVCONFIELD 1=No
;SEVCONFIELD SPLIT=13
;SEVCONFIELD PARAMETERNAME=Motor Forward and Reverse Speed Limits
;SEVCONFIELD BITMASK=0x2000
;SEVCONFIELD BITSHIFT=0xD
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Applied in drive direction only
;SEVCONFIELD 1=Equal and opposite
;SEVCONFIELD SPLIT=14
;SEVCONFIELD PARAMETERNAME=SinCos MinMax Tracking
;SEVCONFIELD BITMASK=0x8000
;SEVCONFIELD BITSHIFT=0xF
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Enabled
;SEVCONFIELD 1=Disabled
[4651]
SubNumber=10
ObjectType=9
ParameterName=Speed control Gains
;SEVCONFIELD OBJECT=VELOCITY_CONTROL_PARAM
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD CATEGORY=CONFIGURATION
[4651sub0]
ParameterName=Number of entries
ParameterValue=0x09
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=12
;SEVCONFIELD OBJECT_VERSION=1
[4651sub1]
ParameterName=Proportional gain
ParameterValue=0x0080
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0x80
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000244140625
;SEVCONFIELD EEPROM=motor_0.vel_ctrl_kp
[4651sub2]
ParameterName=Integral gain
ParameterValue=0x0002
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0x40
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD EEPROM=motor_0.vel_ctrl_ki
[4651sub3]
ParameterName=Low Speed proportional gain
ParameterValue=0x1000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000244140625
;SEVCONFIELD EEPROM=misc.pv_config_vel_control_kp_low
[4651sub4]
ParameterName=Rollback integral gain
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD EEPROM=misc.pv_config_vel_control_ki_rollback
[4651sub5]
ParameterName=Low speed integral gain
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD EEPROM=misc.pv_config_vel_control_ki_low
[4651sub6]
ParameterName=dw/dt gain
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=32767
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD EEPROM=misc.pv_config_vel_control_dw_dt
[4651sub7]
ParameterName=Integral initialization factor
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=4096
PDOMapping=0
DefaultValue=0x1000
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.000244140625
;SEVCONFIELD EEPROM=misc.ac_mtr0_vel_ctrl_integral_init
[4651sub8]
ParameterName=Speed calculation filter pole
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0xF384
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1.52587890625E-05
;SEVCONFIELD EEPROM=misc.ac_mtr0_trq_ctrl_speed_filter
[4651sub9]
ParameterName=Pre-limit speed
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=1000
PDOMapping=0
DefaultValue=100
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=rpm
;SEVCONFIELD EEPROM=misc.ac_mtr0_pre_limit_speed
[4653]
ParameterName=Temporary DSP Configuration
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=DSP_MISC_CONFIG
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD CATEGORY=CONFIGURATION
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=3
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Current Control Quality Monitor (PMAC / DC only)
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Enabled
;SEVCONFIELD 1=Disabled
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME= Force low-frequency PWM mode (DC-SEM field and PMAC Gen4 size8/10 only)
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 1=Enabled
;SEVCONFIELD 0=Disabled
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Force Field Established (DC-SEM only)
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 1=Enabled
;SEVCONFIELD 0=Disabled
[4654]
ParameterName=Current sensor autozero range
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=60
PDOMapping=0
DefaultValue=60
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=A
;SEVCONFIELD OBJECT=MOTOR_AZ_RANGE_CONFIG
;SEVCONFIELD SECTION=MOTOR1SETUP
;SEVCONFIELD CATEGORY=CONFIGURATION
[4680]
SubNumber=2
ObjectType=9
ParameterName=General Digital Input Configuration
;SEVCONFIELD OBJECT=DIG_IN_CONFIG
;SEVCONFIELD SECTION=DIConfiguration
;SEVCONFIELD CATEGORY=CONFIGURATION
[4680sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[4680sub1]
ParameterName=Inputs active
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=io.lcl_di_pullup
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Low
;SEVCONFIELD 1=High
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[4681]
SubNumber=2
ObjectType=9
ParameterName=Digital Input Wire-Off Detection Enable
;SEVCONFIELD OBJECT=DIG_IN_WIRE_OFF_CONFIG
;SEVCONFIELD SECTION=DIConfiguration
;SEVCONFIELD CATEGORY=CONFIGURATION
[4681sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[4681sub1]
ParameterName=Digital Input wire-off enable
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=io.lcl_di_wire_off_enable_0
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=2
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=Digital Input Wire-Off 1
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Digital Input Wire-Off 2
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
[4690]
SubNumber=3
ObjectType=9
ParameterName=General Analog Input Configuration
;SEVCONFIELD OBJECT=ALG_IN_CONFIG
;SEVCONFIELD SECTION=AIConfiguration
;SEVCONFIELD CATEGORY=CONFIGURATION
[4690sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[4690sub1]
ParameterName=Analog input as Digital - Inactive Voltage
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=8
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=io.lcl_ai_dig_off_v
[4690sub2]
ParameterName=Analog input as Digital - Active Voltage
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=56
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=io.lcl_ai_dig_on_v
[46A1]
SubNumber=2
ObjectType=9
ParameterName=Analog Output Current / Voltage mode
;SEVCONFIELD OBJECT=ALG_OUT_I_MODE_ENABLE
;SEVCONFIELD SECTION=AOConfiguration
;SEVCONFIELD CATEGORY=CONFIGURATION
[46A1sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[46A1sub1]
ParameterName=Analog Outputs 1..8, current / voltage mode selection.
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=io.lcl_ao_v_or_i_mode_0
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[46A2]
SubNumber=2
ObjectType=9
ParameterName=Analog Output Auxiliary Frequency
;SEVCONFIELD OBJECT=ALG_OUT_AUX_FREQ
;SEVCONFIELD SECTION=AOConfiguration
;SEVCONFIELD CATEGORY=CONFIGURATION
[46A2sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[46A2sub1]
ParameterName=Analog Output Auxiliary Frequency
ParameterValue=0x03e8
ObjectType=7
DataType=6
AccessType=rw
LowLimit=40
HighLimit=1000
PDOMapping=0
DefaultValue=40
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD UNITS=Hz
;SEVCONFIELD EEPROM=io.lcl_ao_aux_freq
[46A3]
SubNumber=2
ObjectType=9
ParameterName=Analog Output Frequency Selection
;SEVCONFIELD OBJECT=ALG_OUT_FREQ_SELECT
;SEVCONFIELD SECTION=AOConfiguration
;SEVCONFIELD CATEGORY=CONFIGURATION
[46A3sub0]
ParameterName=Number of entries
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
[46A3sub1]
ParameterName=Analog Outputs 1..8, 16kHz or auxiliary frequency selection.
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=io.lcl_ao_freq_select
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[46C0]
SubNumber=3
ObjectType=9
ParameterName=Analogue Input 1 Range
;SEVCONFIELD OBJECT=ALG_IN_VOLTAGE_RANGE
;SEVCONFIELD SECTION=AIConfiguration
;SEVCONFIELD CATEGORY=CONFIGURATION
[46C0sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[46C0sub1]
ParameterName=Minimum allowed voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=misc.analogue_input_min_vals[0]
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[46C0sub2]
ParameterName=Maximum allowed voltage
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0xFFFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=misc.analogue_input_max_vals[0]
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[46C1]
SubNumber=3
ObjectType=9
ParameterName=Analogue Input 2 Range
;SEVCONFIELD OBJECT=ALG_IN_VOLTAGE_RANGE
;SEVCONFIELD SECTION=AIConfiguration
;SEVCONFIELD CATEGORY=CONFIGURATION
[46C1sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[46C1sub1]
ParameterName=Minimum allowed voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=misc.analogue_input_min_vals[1]
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[46C1sub2]
ParameterName=Maximum allowed voltage
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0xFFFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=misc.analogue_input_max_vals[1]
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[46C2]
SubNumber=3
ObjectType=9
ParameterName=Analogue Input 3 Range
;SEVCONFIELD OBJECT=ALG_IN_VOLTAGE_RANGE
;SEVCONFIELD SECTION=AIConfiguration
;SEVCONFIELD CATEGORY=CONFIGURATION
[46C2sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[46C2sub1]
ParameterName=Minimum allowed voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=misc.analogue_input_min_vals[2]
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[46C2sub2]
ParameterName=Maximum allowed voltage
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0xFFFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=misc.analogue_input_max_vals[2]
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[46C3]
SubNumber=3
ObjectType=9
ParameterName=Analogue Input 4 Range
;SEVCONFIELD OBJECT=ALG_IN_VOLTAGE_RANGE
;SEVCONFIELD SECTION=AIConfiguration
;SEVCONFIELD CATEGORY=CONFIGURATION
[46C3sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[46C3sub1]
ParameterName=Minimum allowed voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=misc.analogue_input_min_vals[3]
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[46C3sub2]
ParameterName=Maximum allowed voltage
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0xFFFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=misc.analogue_input_max_vals[3]
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[46C4]
SubNumber=3
ObjectType=9
ParameterName=Analogue Input 5 Range
;SEVCONFIELD OBJECT=ALG_IN_VOLTAGE_RANGE
;SEVCONFIELD SECTION=AIConfiguration
;SEVCONFIELD CATEGORY=CONFIGURATION
[46C4sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[46C4sub1]
ParameterName=Minimum allowed voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=misc.analogue_input_min_vals[4]
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[46C4sub2]
ParameterName=Maximum allowed voltage
ParameterValue=0xffff
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0xFFFF
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=misc.analogue_input_max_vals[4]
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[46D0]
SubNumber=6
ObjectType=9
ParameterName=Analog input resistances
;SEVCONFIELD OBJECT=READ_ALG_IN_RESISTANCE_16_BIT
;SEVCONFIELD SECTION=AIStatus
;SEVCONFIELD CATEGORY=MONITORING
[46D0sub0]
ParameterName=Number of analog inputs
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=8
;SEVCONFIELD OBJECT_VERSION=1
[46D0sub1]
ParameterName=Analog input 1 resistance
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=Ohms
[46D0sub2]
ParameterName=Analog input 2 resistance
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=Ohms
[46D0sub3]
ParameterName=Analog input 3 resistance
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=Ohms
[46D0sub4]
ParameterName=Analog input 4 resistance
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=Ohms
[46D0sub5]
ParameterName=Analog input 5 resistance
ParameterValue=0x7fff
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=Ohms
[5000]
SubNumber=4
ObjectType=9
ParameterName=Password Entry
;SEVCONFIELD OBJECT=PASSWORD
;SEVCONFIELD SECTION=Security
;SEVCONFIELD CATEGORY=MONITORING
[5000sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[5000sub1]
ParameterName=Access Level Indication
ParameterValue=0x04
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=5
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=6
;SEVCONFIELD 0=Not logged in
;SEVCONFIELD 1=User
;SEVCONFIELD 2=Dealer
;SEVCONFIELD 3=Production
;SEVCONFIELD 4=Engineering
;SEVCONFIELD 5=SEVCON
[5000sub2]
ParameterName=Password (16-bit)
ObjectType=7
DataType=6
AccessType=wo
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[5000sub3]
ParameterName=User ID
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[5001]
ParameterName=Password Key
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=5
;SEVCONFIELD OBJECT=PASSWORD_KEY
;SEVCONFIELD SECTION=Security
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD CATEGORY=MONITORING
[5100]
SubNumber=8
ObjectType=9
ParameterName=Device Measurements
;SEVCONFIELD OBJECT=DEVICE_MEASUREMENTS
;SEVCONFIELD SECTION=VEHICLESTATUS
;SEVCONFIELD CATEGORY=MONITORING
[5100sub0]
ParameterName=Number of entries
ParameterValue=0x08
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=9
;SEVCONFIELD OBJECT_VERSION=1
[5100sub1]
ParameterName=Battery Voltage
ParameterValue=0x0550
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
[5100sub2]
ParameterName=Battery Current
ParameterValue=0x0000
ObjectType=7
DataType=3
AccessType=ro
LowLimit=0x8000
HighLimit=0x7FFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=A
[5100sub3]
ParameterName=Capacitor Voltage
ParameterValue=0x00ad
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
[5100sub4]
ParameterName=Heatsink Temperature
ParameterValue=0x16
ObjectType=7
DataType=2
AccessType=ro
LowLimit=-128
HighLimit=127
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=DegC
[5100sub6]
ParameterName=Battery Voltage (8-bit)
ParameterValue=0xff
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=V
[5100sub7]
ParameterName=Capacitor Voltage (8-bit)
ParameterValue=0x2b
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=V
[5100sub8]
ParameterName=Logic 12V supply
ParameterValue=0x0cd4
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
[5110]
ParameterName=NMT State
ParameterValue=0x7f
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=NMT_STATE
;SEVCONFIELD SECTION=CANOPEN_GENERALSTATUS
;SEVCONFIELD NUMBER_FORMAT=3
;SEVCONFIELD 4=Stopped
;SEVCONFIELD 5=Operational
;SEVCONFIELD 127=Pre-Operational
;SEVCONFIELD CATEGORY=MONITORING
[5180]
ParameterName=Capacitor Precharge activate
ObjectType=7
DataType=5
AccessType=wo
LowLimit=0
HighLimit=0xFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=NODE_CAP_PRECHARGE
;SEVCONFIELD SECTION=VEHICLECONFIG
;SEVCONFIELD CATEGORY=MONITORING
[5200]
SubNumber=3
ObjectType=9
ParameterName=Controller key hours
;SEVCONFIELD OBJECT=CONTROLLER_HOURS
;SEVCONFIELD SECTION=HoursCounters
;SEVCONFIELD CATEGORY=LOGGING
[5200sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[5200sub1]
ParameterName=Hours
ParameterValue=0x0031
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD UNITS=Hours
[5200sub2]
ParameterName=Minutes / Seconds
ParameterValue=0xb5
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xEf
PDOMapping=1
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.25
;SEVCONFIELD UNITS=Minutes
[5300]
SubNumber=4
ObjectType=9
ParameterName=Node fault information
;SEVCONFIELD OBJECT=NODE_FAULT_INFO
;SEVCONFIELD SECTION=ActiveFaultLog
;SEVCONFIELD CATEGORY=LOGGING
[5300sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=3
;SEVCONFIELD OBJECT_VERSION=1
[5300sub1]
ParameterName=Number of faults currently active.
ParameterValue=0x0001
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
[5300sub2]
ParameterName=Select position in fault list to read from 5300h, 3
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
[5300sub3]
ParameterName=ID of Fault at position selected in 5300h, 2.
ParameterValue=0x4681
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[5310]
ParameterName=CANopen General Error Abort Code
ParameterValue=0x0003
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=GENERAL_ABORT_CODE
;SEVCONFIELD SECTION=CANOPEN_GENERALSTATUS
;SEVCONFIELD NUMBER_FORMAT=21
;SEVCONFIELD 0=None
;SEVCONFIELD 1=General
;SEVCONFIELD 2=Nothing to Transmit
;SEVCONFIELD 3=Invalid Service
;SEVCONFIELD 4=Not In Preoperational
;SEVCONFIELD 5=Not In Operational
;SEVCONFIELD 6=Cannot goto Preoperational
;SEVCONFIELD 7=Cannot goto Operational
;SEVCONFIELD 8=Access Level too low
;SEVCONFIELD 9=Login Failed
;SEVCONFIELD 10=Range Underflow
;SEVCONFIELD 11=Range Overflow
;SEVCONFIELD 12=Invalid Value
;SEVCONFIELD 13=EEPROM Update Failed
;SEVCONFIELD 14=Cannot reset Service Time
;SEVCONFIELD 15=Cannot Reset Log
;SEVCONFIELD 16=Cannot Read Log
;SEVCONFIELD 17=Invalid Store Command
;SEVCONFIELD 18=Bootloader Failure
;SEVCONFIELD 19=DSP Update Failed
;SEVCONFIELD 20=GIO Update Failed
;SEVCONFIELD CATEGORY=MONITORING
[5320]
ParameterName=Currently active highest priority fault
ParameterValue=0x4681
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=NODE_HIGHEST_PRIORITY_FAULT
;SEVCONFIELD SECTION=ActiveFaultLog
;SEVCONFIELD CATEGORY=MONITORING
[5400]
ParameterName=Bootloader Activate
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
ObjFlags=0x3
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD OBJECT=BOOTLOADER_INIT
;SEVCONFIELD SECTION=CANOPEN_GENERALCONTROL
;SEVCONFIELD COMMS_TIMEOUT=1
;SEVCONFIELD CATEGORY=MONITORING
[5500]
ParameterName=NVM Format
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=NVM_FORMAT
;SEVCONFIELD SECTION=Identity
;SEVCONFIELD CATEGORY=MONITORING
[5501]
ParameterName=Internal ROM Checksum
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=INTERNAL_ROM_CHECKSUM
;SEVCONFIELD SECTION=Identity
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD CATEGORY=MONITORING
[5502]
ParameterName=External ROM Checksum
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=EXTERNAL_ROM_CHECKSUM
;SEVCONFIELD SECTION=Identity
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD CATEGORY=MONITORING
[5600]
SubNumber=10
ObjectType=9
ParameterName=Node domain uploads
;SEVCONFIELD OBJECT=DOMAIN_UPLOAD
;SEVCONFIELD SECTION=DomainLogs
;SEVCONFIELD CATEGORY=MONITORING
[5600sub0]
ParameterName=Number of entries
ParameterValue=0x0a
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=9
;SEVCONFIELD OBJECT_VERSION=1
[5600sub1]
ParameterName=System FIFO
ParameterValue=0x00ff00ff00ff0061001a344100ff00ff00ff0050001a344100ff00ff00ff00de000f344100ff00ff00ff00ad000f344100ff00ff00ff0090000a3441000900bf0020007a000a344100ff00ff00ff004e000a3441000900bf00200005000a344100ff00ff00ff00dd00093441000200c20020001800073441
ObjectType=7
DataType=15
AccessType=ro
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD COMMS_TIMEOUT=20000
[5600sub2]
ParameterName=Faults FIFO
ParameterValue=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
ObjectType=7
DataType=15
AccessType=ro
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD COMMS_TIMEOUT=20000
[5600sub3]
ParameterName=Event Counters
ParameterValue=0x001f00240030001800075043000100610020006100204f55000a0061001a001800073441000200c7001a0003001854c100410003003000a9000150440002001900070018000752c4000900ec002f0038001e4f410002001500160005001651c20033009e00130000000051010013008c002d0067001a4f4c
ObjectType=7
DataType=15
AccessType=ro
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD COMMS_TIMEOUT=20000
[5600sub4]
ParameterName=Customer Operational Monitor
ParameterValue=0x00410012116ef6ea80007fff02c800000658000006680278
ObjectType=7
DataType=15
AccessType=ro
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD COMMS_TIMEOUT=20000
[5600sub5]
ParameterName=Sevcon Operational Monitor
ParameterValue=0x00400012116ef6ea80007fff02400000065f007606500288
ObjectType=7
DataType=15
AccessType=ro
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD COMMS_TIMEOUT=20000
[5600sub6]
ParameterName=Active Fault List
ParameterValue=0x4681
ObjectType=7
DataType=15
AccessType=ro
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD COMMS_TIMEOUT=20000
[5600sub7]
ParameterName=Debug
ParameterValue=0x0002000000460000001a0001000a000000460052001a5044000a005100460052001a5043000a03e817700000000007d007d007d000000000001a5043000000000000000000000000
ObjectType=7
DataType=15
AccessType=ro
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD COMMS_TIMEOUT=20000
[5600sub8]
ParameterName=CLI In
ObjectType=7
DataType=15
AccessType=wo
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD COMMS_TIMEOUT=20000
[5600subA]
ParameterName=Event List
ParameterValue=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
ObjectType=7
DataType=15
AccessType=ro
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD COMMS_TIMEOUT=40000
[5601]
SubNumber=6
ObjectType=9
ParameterName=Indirect Object Update
;SEVCONFIELD OBJECT=INDIRECT_OBJECT_UPDATE
;SEVCONFIELD SECTION=CANOPEN_GENERALCONTROL
;SEVCONFIELD CATEGORY=MONITORING
[5601sub0]
ParameterName=Number of entries
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=4
;SEVCONFIELD OBJECT_VERSION=1
[5601sub1]
ParameterName=Index
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[5601sub2]
ParameterName=Sub-Index
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFE
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[5601sub3]
ParameterName=New Value
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[5601sub4]
ParameterName=Seed/Unlock code
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[5601sub5]
ParameterName=Result
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[5602]
SubNumber=6
ObjectType=9
ParameterName=Debug object
;SEVCONFIELD OBJECT=DEBUG_CONTROL
;SEVCONFIELD SECTION=CANOPEN_GENERALCONTROL
;SEVCONFIELD CATEGORY=MONITORING
[5602sub0]
ParameterName=Number of entries
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=19
;SEVCONFIELD OBJECT_VERSION=1
[5602sub1]
ParameterName=Debug value 1
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
[5602sub2]
ParameterName=Debug value 2
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
[5602sub3]
ParameterName=Debug value 3
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
[5602sub4]
ParameterName=Debug value 4
ParameterValue=0x00000000
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=1
;SEVCONFIELD OBJECT_VERSION=1
[5602sub5]
ParameterName=Enable debug output
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
[5603]
SubNumber=3
ObjectType=9
ParameterName=Host/DSP Memory peek
;SEVCONFIELD OBJECT=MEMORY_PEEK
;SEVCONFIELD SECTION=CANOPEN_GENERALCONTROL
;SEVCONFIELD CATEGORY=MONITORING
[5603sub0]
ParameterName=Number of entries
ParameterValue=0x04
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=4
;SEVCONFIELD OBJECT_VERSION=1
[5603sub3]
ParameterName=Slave address
ObjectType=7
DataType=7
AccessType=rw
LowLimit=0
HighLimit=0xFFFFFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=5
[5603sub4]
ParameterName=Slave 16-bit value
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=2
;SEVCONFIELD ACCESS_LEVEL=5
[5604]
SubNumber=3
ObjectType=9
ParameterName=DSP Trace Object
;SEVCONFIELD OBJECT=DSP_DETAILED_TRACE
;SEVCONFIELD SECTION=CANOPEN_GENERALSTATUS
;SEVCONFIELD CATEGORY=MONITORING
[5604sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[5604sub1]
ParameterName=Trace Index
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
[5604sub2]
ParameterName=Trace Data
ObjectType=7
DataType=15
AccessType=ro
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
[5605]
SubNumber=10
ObjectType=9
ParameterName=Timing Analysis
;SEVCONFIELD OBJECT=TIMING_ANALYSIS
;SEVCONFIELD SECTION=NODE_STATUS
;SEVCONFIELD CATEGORY=MONITORING
[5605sub0]
ParameterName=Number of entries
ParameterValue=0x09
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=9
;SEVCONFIELD OBJECT_VERSION=1
[5605sub1]
ParameterName=ID
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
[5605sub2]
ParameterName=Sample rate
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
[5605sub3]
ParameterName=Periodic Minimum Time
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.4
;SEVCONFIELD UNITS=us
[5605sub4]
ParameterName=Periodic Maximum Time
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.4
;SEVCONFIELD UNITS=us
[5605sub5]
ParameterName=Periodic Average Time
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.4
;SEVCONFIELD UNITS=us
[5605sub6]
ParameterName=Interval Minimum Time
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.4
;SEVCONFIELD UNITS=us
[5605sub7]
ParameterName=Interval Maximum Time
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.4
;SEVCONFIELD UNITS=us
[5605sub8]
ParameterName=Interval Average Time
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD SCALING=0.4
;SEVCONFIELD UNITS=us
[5605sub9]
ParameterName=Interval Overflow Counter
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=1
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
[5610]
SubNumber=3
ObjectType=9
ParameterName=Event information
;SEVCONFIELD OBJECT=EVENT_ID_DESCRIPTION
;SEVCONFIELD SECTION=DomainLogs
;SEVCONFIELD CATEGORY=MONITORING
[5610sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[5610sub1]
ParameterName=Event ID
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[5610sub2]
ParameterName=Event Name
ParameterValue=<Event ID Unknown>
ObjectType=7
DataType=9
AccessType=ro
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
[5620]
ParameterName=Configuration Checksum
ParameterValue=0xe87f
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD OBJECT=CONFIG_CHECKSUM
;SEVCONFIELD SECTION=CANOPEN_GENERALSTATUS
;SEVCONFIELD NUMBER_FORMAT=BASE16
;SEVCONFIELD CATEGORY=MONITORING
[5621]
SubNumber=3
ObjectType=9
ParameterName=Range Check Failed Objects
;SEVCONFIELD OBJECT=RANGE_CHECK_FAILED_OBJECT
;SEVCONFIELD SECTION=VEHICLESTATUS
;SEVCONFIELD CATEGORY=MONITORING
[5621sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[5621sub1]
ParameterName=Index
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x1
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[5621sub2]
ParameterName=Sub-index
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BASE16
[5630]
SubNumber=12
ObjectType=9
ParameterName=EDS Upload
;SEVCONFIELD OBJECT=EDS_UPLOAD
;SEVCONFIELD SECTION=CANOPEN_GENERALSTATUS
;SEVCONFIELD CATEGORY=MONITORING
[5630sub0]
ParameterName=Number of entries
ParameterValue=0x0b
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=10
;SEVCONFIELD OBJECT_VERSION=1
[5630sub1]
ParameterName=OD table index
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
[5630sub2]
ParameterName=Index
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
[5630sub3]
ParameterName=Sub-Index
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
[5630sub4]
ParameterName=Object Type
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
[5630sub5]
ParameterName=Data Type
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=15
;SEVCONFIELD 0=Boolean
;SEVCONFIELD 1=Integer8
;SEVCONFIELD 2=Integer16
;SEVCONFIELD 3=Integer32
;SEVCONFIELD 4=Integer64
;SEVCONFIELD 5=Unsigned8
;SEVCONFIELD 6=Unsigned16
;SEVCONFIELD 7=Unsigned32
;SEVCONFIELD 8=Unsigned64
;SEVCONFIELD 9=VisibleString
;SEVCONFIELD 10=Domain
;SEVCONFIELD 11=OctetString
;SEVCONFIELD 12=Real32
;SEVCONFIELD 13=Real64
;SEVCONFIELD 14=Void
;SEVCONFIELD 15=Domain
[5630sub6]
ParameterName=Access
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=4
;SEVCONFIELD 0=ro
;SEVCONFIELD 1=wo
;SEVCONFIELD 2=rw
;SEVCONFIELD 3=const
[5630sub7]
ParameterName=Low Limit
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
[5630sub8]
ParameterName=High Limit
ObjectType=7
DataType=7
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
[5630sub9]
ParameterName=PDO Mappable?
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
[5630subA]
ParameterName=Object Version
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
[5630subB]
ParameterName=Object Flags
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
[5631]
SubNumber=4
ObjectType=9
ParameterName=EDS Upload - Information
;SEVCONFIELD OBJECT=EDS_UPLOAD_INFO
;SEVCONFIELD SECTION=CANOPEN_GENERALSTATUS
;SEVCONFIELD CATEGORY=MONITORING
[5631sub0]
ParameterName=Number of entries
ParameterValue=0x03
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[5631sub1]
ParameterName=Supported Baudrates
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=8
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=10kHz
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=20kHz
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=50kHz
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=125kHz
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=250kHz
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=500kHz
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=800kHz
;SEVCONFIELD BITMASK=0x40
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=7
;SEVCONFIELD PARAMETERNAME=1MHz
;SEVCONFIELD BITMASK=0x80
;SEVCONFIELD BITSHIFT=0x7
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
[5631sub2]
ParameterName=LSS supported?
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
[5631sub3]
ParameterName=Supported Dummy RPDO maps
ObjectType=7
DataType=6
AccessType=ro
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
ObjFlags=0x3
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=7
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=BOOLEAN
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=INTEGER8
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=INTEGER16
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=INTEGER32
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=UNSIGNED8
;SEVCONFIELD BITMASK=0x10
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=UNSIGNED16
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=UNSIGNED32
;SEVCONFIELD BITMASK=0x40
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
[5800]
ParameterName=Master / Slave configuration
ParameterValue=0x01
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=MASTER_SLAVE_CONFIG
;SEVCONFIELD SECTION=CANopenSetup
;SEVCONFIELD EEPROM=node.is_master
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Slave
;SEVCONFIELD 1=Master
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[5810]
SubNumber=7
ObjectType=9
ParameterName=Automatic Configuration Set Up
;SEVCONFIELD OBJECT=PHYSICAL_LAYER_SETTINGS
;SEVCONFIELD SECTION=CANopenSetup
;SEVCONFIELD CATEGORY=CONFIGURATION
[5810sub0]
ParameterName=Number of entries
ParameterValue=0x07
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=7
;SEVCONFIELD OBJECT_VERSION=1
[5810sub1]
ParameterName=Ctrl Flags
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=6
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=CANopen Auto Configuration
;SEVCONFIELD BITMASK=0x3
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Digital Input Auto Configuration
;SEVCONFIELD BITMASK=0xC
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=3
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=VPDO Only
;SEVCONFIELD 2=PDO Only
;SEVCONFIELD 3=Both PDO and VPDO
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Digital Output Auto Configuration
;SEVCONFIELD BITMASK=0x30
;SEVCONFIELD BITSHIFT=0x4
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=3
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=VPDO Only
;SEVCONFIELD 2=PDO Only
;SEVCONFIELD 3=Both PDO and VPDO
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Analogue Input Auto Configuration
;SEVCONFIELD BITMASK=0xC0
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=3
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=VPDO Only
;SEVCONFIELD 2=PDO Only
;SEVCONFIELD 3=Both PDO and VPDO
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=Analogue Output Auto Configuration
;SEVCONFIELD BITMASK=0x300
;SEVCONFIELD BITSHIFT=0x8
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=3
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=VPDO Only
;SEVCONFIELD 2=PDO Only
;SEVCONFIELD 3=Both PDO and VPDO
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=Motor Auto Configuration
;SEVCONFIELD BITMASK=0xC00
;SEVCONFIELD BITSHIFT=0xA
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=3
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=VPDO Only
;SEVCONFIELD 2=PDO Only
;SEVCONFIELD 3=Both PDO and VPDO
[5810sub2]
ParameterName=CANopen Network Description
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=7
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=This node is a
;SEVCONFIELD BITMASK=0x1F
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=6
;SEVCONFIELD NUMBERFORMAT=6
;SEVCONFIELD 0=Slave
;SEVCONFIELD 1=Master(local is left traction)
;SEVCONFIELD 2=Master(local is right traction)
;SEVCONFIELD 3=Master(local is pump)
;SEVCONFIELD 4=Master(local is power steer)
;SEVCONFIELD 5=Master(io module or other)
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Left Traction
;SEVCONFIELD BITMASK=0x20
;SEVCONFIELD BITSHIFT=0x5
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Right Traction
;SEVCONFIELD BITMASK=0x40
;SEVCONFIELD BITSHIFT=0x6
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Pump
;SEVCONFIELD BITMASK=0x80
;SEVCONFIELD BITSHIFT=0x7
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=4
;SEVCONFIELD PARAMETERNAME=Power Steer
;SEVCONFIELD BITMASK=0x100
;SEVCONFIELD BITSHIFT=0x8
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=5
;SEVCONFIELD PARAMETERNAME=not used
;SEVCONFIELD BITMASK=0x200
;SEVCONFIELD BITSHIFT=0x9
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
;SEVCONFIELD SPLIT=6
;SEVCONFIELD PARAMETERNAME=Sevcon PST Module
;SEVCONFIELD BITMASK=0x400
;SEVCONFIELD BITSHIFT=0xA
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=No
;SEVCONFIELD 1=Yes
[5810sub3]
ParameterName=Digital Input Configuration
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=11
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
[5810sub5]
ParameterName=Analogue Input Configuration
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=7
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
[5810sub6]
ParameterName=Analogue Output Configuration
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=13
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
[5810sub7]
ParameterName=Valid configurations
ParameterValue=0x003c
ObjectType=7
DataType=15
AccessType=ro
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
[5811]
SubNumber=7
ObjectType=9
ParameterName=Automatic Configuration Set Up
;SEVCONFIELD OBJECT=PHYSICAL_LAYER_SETTINGS
;SEVCONFIELD SECTION=CANopenSetup
;SEVCONFIELD CATEGORY=CONFIGURATION
[5811sub0]
ParameterName=Number of entries
ParameterValue=0x07
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=7
;SEVCONFIELD OBJECT_VERSION=1
[5811sub1]
ParameterName=Digital Input Slave Config
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=13
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
[5811sub3]
ParameterName=Analogue Input Slave Config
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=5
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
[5811sub4]
ParameterName=Analogue Output Slave Config
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=3
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
[5811sub5]
ParameterName=Motors slave config
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
[5811sub6]
ParameterName=Display Options
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
[5811sub7]
ParameterName=Complete
ObjectType=7
DataType=1
AccessType=wo
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
[5820]
ParameterName=Final precharge level
ParameterValue=0x5a
ObjectType=7
DataType=5
AccessType=rw
LowLimit=50
HighLimit=90
PDOMapping=0
DefaultValue=90
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=%
;SEVCONFIELD OBJECT=FINAL_PRECHARGE_LEVEL
;SEVCONFIELD SECTION=NodeSetup
;SEVCONFIELD CATEGORY=CONFIGURATION
[5821]
ParameterName=Minimum precharge level
ParameterValue=0x0140
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0x0050
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0x00A0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.0625
;SEVCONFIELD UNITS=V
;SEVCONFIELD OBJECT=FINAL_PRECHARGE_LEVEL
;SEVCONFIELD SECTION=NodeSetup
;SEVCONFIELD CATEGORY=CONFIGURATION
[5830]
ParameterName=PWM Configuration
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=DSP_MISC_CONFIG
;SEVCONFIELD SECTION=NodeSetup
;SEVCONFIELD CATEGORY=CONFIGURATION
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD NUMBER_FORMAT=BIT_SPLIT
;SEVCONFIELD NUMBER_SPLIT=4
;SEVCONFIELD SPLIT=0
;SEVCONFIELD PARAMETERNAME=PWM Switching Frequency
;SEVCONFIELD BITMASK=0x1
;SEVCONFIELD BITSHIFT=0x0
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=8kHz
;SEVCONFIELD 1=12kHz
;SEVCONFIELD SPLIT=1
;SEVCONFIELD PARAMETERNAME=Deadtime Compensation
;SEVCONFIELD BITMASK=0x2
;SEVCONFIELD BITSHIFT=0x1
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Enabled
;SEVCONFIELD 1=Disabled
;SEVCONFIELD SPLIT=2
;SEVCONFIELD PARAMETERNAME=Reserved PWM mode
;SEVCONFIELD BITMASK=0x4
;SEVCONFIELD BITSHIFT=0x2
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
;SEVCONFIELD SPLIT=3
;SEVCONFIELD PARAMETERNAME=Reserved PWM mode
;SEVCONFIELD BITMASK=0x8
;SEVCONFIELD BITSHIFT=0x3
;SEVCONFIELD LOW_LIMIT=0
;SEVCONFIELD HIGH_LIMIT=1
;SEVCONFIELD NUMBERFORMAT=2
;SEVCONFIELD 0=Off
;SEVCONFIELD 1=On
[5900]
SubNumber=3
ObjectType=9
ParameterName=Physical layer settings
;SEVCONFIELD OBJECT=PHYSICAL_LAYER_SETTINGS
;SEVCONFIELD SECTION=CANopenSetup
;SEVCONFIELD CATEGORY=CONFIGURATION
[5900sub0]
ParameterName=Number of entries
ParameterValue=0x02
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=2
;SEVCONFIELD OBJECT_VERSION=1
[5900sub1]
ParameterName=Node ID
ParameterValue=0x01
ObjectType=7
DataType=5
AccessType=rw
LowLimit=1
HighLimit=127
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=node.node_id
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[5900sub2]
ParameterName=Bit rate
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=6
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=node.bit_rate
;SEVCONFIELD NUMBER_FORMAT=8
;SEVCONFIELD 0=1Mb
;SEVCONFIELD 1=500kb
;SEVCONFIELD 2=250kb
;SEVCONFIELD 3=125kb
;SEVCONFIELD 4=100kb
;SEVCONFIELD 5=50kb
;SEVCONFIELD 6=20kb
;SEVCONFIELD 7=10kb
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[5901]
ParameterName=CANbus fault detection on Standalone units
ParameterValue=0x00
ObjectType=7
DataType=1
AccessType=rw
LowLimit=0
HighLimit=1
PDOMapping=0
DefaultValue=1
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=MASTER_SLAVE_CONFIG
;SEVCONFIELD SECTION=CANopenSetup
;SEVCONFIELD EEPROM=misc.enable_can_faults
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Enabled
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[5902]
ParameterName=RPDO timeout scheme
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=3
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD OBJECT=RPDO_TIMEOUT_SCHEME
;SEVCONFIELD SECTION=CANopenSetup
;SEVCONFIELD NUMBER_FORMAT=4
;SEVCONFIELD 0=Disabled
;SEVCONFIELD 1=Warn and Slow Down
;SEVCONFIELD 2=Inhibit Drive
;SEVCONFIELD 3=Severe
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
;SEVCONFIELD CATEGORY=CONFIGURATION
[5A01]
SubNumber=6
ObjectType=9
ParameterName=External heat sink fans
;SEVCONFIELD OBJECT=HEATSINK_FAN
;SEVCONFIELD SECTION=FansConfig
;SEVCONFIELD CATEGORY=CONFIGURATION
[5A01sub0]
ParameterName=Number of entries
ParameterValue=0x05
ObjectType=7
DataType=5
AccessType=ro
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=4
;SEVCONFIELD OBJECT_VERSION=1
[5A01sub1]
ParameterName=External fan analogue output
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=misc.fan_output
;SEVCONFIELD WRITE_IN_PREOPERATIONAL_ONLY=TRUE
[5A01sub2]
ParameterName=External fan turn on temperature
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=-30
HighLimit=127
PDOMapping=0
DefaultValue=50
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=DegC
;SEVCONFIELD EEPROM=misc.fan_on_temperature
[5A01sub3]
ParameterName=External fan turn off temperature
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=-30
HighLimit=127
PDOMapping=0
DefaultValue=40
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=1
;SEVCONFIELD UNITS=DegC
;SEVCONFIELD EEPROM=misc.fan_off_temperature
[5A01sub4]
ParameterName=Fan voltage
ParameterValue=0x0000
ObjectType=7
DataType=6
AccessType=rw
LowLimit=0
HighLimit=0xFFFF
PDOMapping=0
DefaultValue=0x1800
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=2
;SEVCONFIELD SCALING=0.00390625
;SEVCONFIELD UNITS=V
;SEVCONFIELD EEPROM=misc.fan_voltage
[5A01sub5]
ParameterName=Fan Temperature Source
ParameterValue=0x00
ObjectType=7
DataType=5
AccessType=rw
LowLimit=0
HighLimit=0xFF
PDOMapping=0
DefaultValue=0
;SEVCONFIELD OBJECT_VERSION=1
;SEVCONFIELD ACCESS_LEVEL=4
;SEVCONFIELD EEPROM=misc.fan_temperature_selection
;SEVCONFIELD NUMBER_FORMAT=2
;SEVCONFIELD 0=Controller heatsink
;SEVCONFIELD 1=Motor temperature sensor
;SEVCONFIELD
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment