Last active
March 14, 2023 17:23
-
-
Save MorGuux/832054bcbe6c1207b1f3075d5ecf6a4a to your computer and use it in GitHub Desktop.
BMW E90 KCAN Notes
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Title | ID | Result Name | Data Type | Unit | MUL Factor | ADD Factor | Label | Description | |
---|---|---|---|---|---|---|---|---|---|
OBD_PID01_DSMRdy_xPId1 | 0x0001 | STAT_DSMRdy_xPId1_WERT | unsigned long | hex | 1.000000 | 0.000000 | OBD_PID01_DSMRdy_xPId1 | Number of confirmed DTCs and MIL status | |
OBD_PID04_CoETS_rTrq | 0x0004 | STAT_CoETS_rTrq_WERT | unsigned char | % | 0.392157 | 0.000000 | OBD_PID04_CoETS_rTrq | Calculated load value | |
OBD_PID05_CEngDsT_tSens | 0x0005 | STAT_CEngDsT_tSens_WERT | unsigned char | degC | 1.000000 | -40.000000 | OBD_PID05_CEngDsT_tSens | Coolant temperature (sensor value before correction) | |
OBD_PID0B_Air_pSensPIntkVUs | 0x000B | STAT_Air_pSensPIntkVUs_WERT | unsigned char | kPa | 1.000000 | 0.000000 | OBD_PID0B_Air_pSensPIntkVUs | Boost pressure (sensor value before correction) | |
OBD_PID0C_Epm_nEngRaw | 0x000C | STAT_Epm_nEngRaw_WERT | unsigned int | rpm | 0.250000 | 0.000000 | OBD_PID0C_Epm_nEngRaw | Engine speed - raw value before correction for OBD tester | |
OBD_PID0D_VehV_vSens | 0x000D | STAT_VehV_vSens_WERT | unsigned char | km/h | 1.000000 | 0.000000 | OBD_PID0D_VehV_vSens | Vehicle speed | |
OBD_PID0F_Air_tSensTAFS | 0x000F | STAT_Air_tSensTAFS_WERT | unsigned char | degC | 1.000000 | -40.000000 | OBD_PID0F_Air_tSensTAFS | Intake air temperature | |
OBD_PID10_AFS_dmSens | 0x0010 | STAT_AFS_dmSens_WERT | unsigned int | g/s | 0.010000 | 0.000000 | OBD_PID10_AFS_dmSens | Air mass from HFM | |
OBD_PID11_ThrVlv_rNrm | 0x0011 | STAT_ThrVlv_rNrm_WERT | unsigned char | % | 0.392157 | 0.000000 | OBD_PID11_ThrVlv_rNrm | Output duty cycle - throttle (before correction) | |
OBD_PID1C_I15031_PID1C | 0x001C | STAT_I15031_PID1C_WERT | unsigned char | - | 1.000000 | 0.000000 | OBD_PID1C_I15031_PID1C | OBD registration of the vehicle | |
OBD_PID1D_I15031_PID1D | 0x001D | STAT_I15031_PID1D_WERT | unsigned char | - | 1.000000 | 0.000000 | OBD_PID1D_I15031_PID1D | Position of lambda sensor(s) | |
OBD_PID1F_CoEng_tiNormal | 0x001F | STAT_CoEng_tiNormal_WERT | unsigned int | s | 1.000000 | 0.000000 | OBD_PID1F_CoEng_tiNormal | Operating time since last engine start | |
OBD_PID21_DSMDur_ctGlb_0 | 0x0021 | STAT_DSMDur_ctGlb_0_WERT | unsigned int | km | 1.000000 | 0.000000 | OBD_PID21_DSMDur_ctGlb_0 | Distance driven in MIL ON state | |
OBD_PID23_RailP_pLin | 0x0023 | STAT_RailP_pLin_WERT | unsigned int | kPa | 10.000000 | 0.000000 | OBD_PID23_RailP_pLin | Rail pressure (linearised) | |
OBD_PID24_LSU_rLamPID_uO2Raw_AB | 0x0024 | STAT_LSU_rLam_WERT | unsigned int | - | 0.000031 | 0.000000 | OBD_PID24_LSU_rLamPID_uO2Raw_AB | Oxygen Sensor Signal - Equivalence Ratio Bank 1 - Sensor 1 | |
OBD_PID25_LSU_rLamPID_uO2Raw_AB | 0x0025 | STAT_OBD_PID25_LSU_rLamPID_uO2Raw_AB_WERT | unsigned int | - | 0.000031 | 0.000000 | OBD_PID25_LSU_rLamPID_uO2Raw_AB | Oxygen Sensor Output - Equivalence Ratio Bank 1 - Sensor 2 | |
OBD_PID2C_EGRVlv_r | 0x002C | STAT_EGRVlv_r_WERT | unsigned char | % | 0.392157 | 0.000000 | OBD_PID2C_EGRVlv_r | Output Duty Cycle - Exhaust Gas Recirculation Control Valve | |
OBD_PID2D_EGRVlv_rGovDvtRel | 0x002D | STAT_EGRVlv_rGovDvtRel_WERT | unsigned char | % | 0.781255 | -100.000000 | OBD_PID2D_EGRVlv_rGovDvtRel | Exhaust gas recirculation regulator - Control deviation | |
OBD_PID30_DSMAUX_ctWUC | 0x0030 | STAT_DSMAUX_ctWUC_WERT | unsigned char | - | 1.000000 | 0.000000 | OBD_PID30_DSMAUX_ctWUC | Number of warm-ups since DTCs were deleted | |
OBD_PID31_DSMDur_ctGlb_1 | 0x0031 | STAT_DSMDur_ctGlb_1_WERT | unsigned int | km | 1.000000 | 0.000000 | OBD_PID31_DSMDur_ctGlb_1 | Distance travelled since last fault code clearing | |
OBD_PID33_EnvP_pSens | 0x0033 | STAT_EnvP_pSens_WERT | unsigned char | kPa | 1.000000 | 0.000000 | OBD_PID33_EnvP_pSens | Ambient pressure (sensor value before correction) | |
OBD_PID3C_Exh_tSensTOxiCatUs | 0x003C | STAT_Exh_tSensTOxiCatUs_WERT | unsigned int | degC | 0.100000 | -40.000000 | OBD_PID3C_Exh_tSensTOxiCatUs | Catalyst Temperature Bank 1, Sensor 1 | |
OBD_PID3E_Exh_tSensTPFltUs | 0x003E | STAT_Exh_tSensTPFltUs_WERT | unsigned int | degC | 0.100000 | -40.000000 | OBD_PID3E_Exh_tSensTPFltUs | Catalyst Temperature Bank 1, Sensor 2 | |
OBD_PID41_DSMRdy_xPId41 | 0x0041 | STAT_DSMRdy_xPId41_WERT | unsigned long | - | 1.000000 | 0.000000 | OBD_PID41_DSMRdy_xPId41 | monitor status since last engine shut off | |
IUBAT | 0x0042 | STAT_UBATT_WERT | unsigned int | Volt | 0.001000 | 0.000000 | OBD_PID42_BattU_uSens | Battery voltage (sensor value before correction) | |
OBD_PID45_ThrVlv_rAct | 0x0045 | STAT_ThrVlv_rAct_WERT | unsigned char | % | 0.392157 | 0.000000 | OBD_PID45_ThrVlv_rAct | Throttle - actual position corrected | |
OBD_PID46_EnvT_tSens | 0x0046 | STAT_EnvT_tSens_WERT | unsigned char | degC | 1.000000 | -40.000000 | OBD_PID46_EnvT_tSens | Ambient temperature | |
OBD_PID49_APP_rUnFlt | 0x0049 | STAT_APP_rUnFlt_WERT | unsigned char | % | 0.392157 | 0.000000 | OBD_PID49_APP_rUnFlt | Pedal sensor - unfiltered signal | |
OBD_PID4A_APP_uRaw2 | 0x004A | STAT_APP_uRaw2_WERT | unsigned char | Volt | 3.921569 | 0.000000 | OBD_PID4A_APP_uRaw2 | Pedal value sensor - raw voltage from sensor 2 | |
OBD_PID4C_ThrVlv_r | 0x004C | STAT_ThrVlv_r_WERT | unsigned char | % | 0.392157 | 0.000000 | OBD_PID4C_ThrVlv_r | Throttle valve - target duty cycle | |
OBD_PID24_LSU_rLamPID_uO2Raw_CD | 0x010E | STAT_LSU_uO2Raw_WERT | unsigned int | Volt | 0.000122 | 0.000000 | OBD_PID24_LSU_rLamPID_uO2Raw_CD | Lambda sensor signal - Oxygen sensor voltage bank 1 - sensor 1 | |
OBD_PID25_LSU_rLamPID_uO2Raw_CD | 0x0112 | STAT_OBD_PID25_LSU_rLamPID_uO2Raw_CD_WERT | unsigned int | Volt | 0.000122 | 0.000000 | OBD_PID25_LSU_rLamPID_uO2Raw_CD | Oxygen sensor output - Oxygen sensor voltage bank 1 - sensor 2 | |
IUBAT2 | 0x012C | STAT_UBATT2_WERT | unsigned int | mV | 0.389105 | 0.000000 | BattU_u | Battery Voltage | |
BattU_uSens | 0x012D | STAT_BattU_uSens_WERT | unsigned int | mV | 0.389105 | 0.000000 | BattU_uSens | Detected battery voltage | |
ITZUH | 0x014A | STAT_ZUHEIZER_ANSTEUERUNG_WERT | unsigned int | % | 0.001526 | 0.000000 | WaHtEl_rPs | Booster heater output duty cycle | |
WaHt_stShutOff_mp | 0x014C | STAT_WaHt_stShutOff_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | WaHt_stShutOff_mp | Status switch-off conditions for auxiliary heater | |
IFPWG | 0x015E | STAT_FAHRERWUNSCH_PEDAL_WERT | unsigned int | % | 0.001526 | 0.000000 | APP_rFlt_mp | Filtered pedal encoder signal | |
IUPW1 | 0x015F | STAT_PWG1_SPANNUNG_WERT | unsigned int | mV | 0.076295 | 0.000000 | APP_uRaw1 | Pedal encoder signal 1 - raw voltage value | |
IUPW2 | 0x0160 | STAT_PWG2_SPANNUNG_WERT | unsigned int | mV | 0.076295 | 0.000000 | APP_uRaw2 | Pedal encoder signal 2 - raw voltage value | |
APP_r | 0x0162 | STAT_APP_r_WERT | unsigned int | % | 0.012207 | 0.000000 | APP_r | Pedal encoder position | |
APP_stSigSrc | 0x0163 | STAT_APP_stSigSrc_WERT | unsigned char | - | 1.000000 | 0.000000 | APP_stSigSrc | Status of the guidance signal for further calculation of the driver's request | |
APP_stKD | 0x0164 | STAT_APP_stKD_WERT | unsigned char | - | 1.000000 | 0.000000 | APP_stKD | Status of kickdown (accelerator pedal) | |
AccPed_trqDes | 0x0168 | STAT_AccPed_trqDes_WERT | unsigned long | Nm | 0.100000 | 0.000000 | AccPed_trqDes | Driver's desired torque Target path | |
IGENL | 0x0186 | STAT_GENERATORLAST_WERT | unsigned int | % | 0.003052 | 0.000000 | AltIO_rAltLoad | Raw load to the generator | |
Gen_awnumm | 0x0187 | STAT_Gen_awnumm_WERT | unsigned char | - | 1.000000 | 0.000000 | Gen_awnumm | Generator map number | |
St_genallg | 0x0188 | STAT_St_genallg_WERT | unsigned char | - | 1.000000 | 0.000000 | St_genallg | Status byte generator in general | |
Tn_abstell | 0x01AE | STAT_Tn_abstell_WERT | unsigned int | s | 1.000000 | 0.000000 | Tn_abstell | Cut-off time | |
SUGEN | 0x01AF | STAT_SOLLWERT_GENERATORSPANNUNG_WERT | unsigned int | V | 0.100000 | 0.000000 | U_gen | Set generator set voltage (output value) | |
Absch_korr | 0x01B0 | STAT_Absch_korr_WERT | unsigned int | - | 0.001526 | 0.000000 | Absch_korr | Correction value Shutdown | |
D_soc | 0x01B1 | STAT_D_soc_WERT | unsigned int | - | 0.003052 | 0.000000 | D_soc | Distance to start capability limit | |
IIBAT | 0x01B2 | STAT_BATTERIESTROM_IBS_WERT | unsigned int | A | 0.080000 | -200.000000 | I_batt | Battery current measured by IBS | |
Stat_sv_reg1 | 0x01B3 | STAT_Stat_sv_reg1_WERT | unsigned char | - | 1.000000 | 0.000000 | Stat_sv_reg1 | Status of stand consumer 1 registered | |
Stat_sv_reg2 | 0x01B4 | STAT_Stat_sv_reg2_WERT | unsigned char | - | 1.000000 | 0.000000 | Stat_sv_reg2 | Status of stand consumer 2 registered | |
T2histshort | 0x01B5 | STAT_T2histshort_WERT | unsigned char | min | 14.933333 | 0.000000 | T2histshort | Quiescent current time - history 2 | |
T3histshort | 0x01B6 | STAT_T3histshort_WERT | unsigned char | min | 14.933333 | 0.000000 | T3histshort | Quiescent current time - history 3 | |
T4histshort | 0x01B7 | STAT_T4histshort_WERT | unsigned char | min | 14.933333 | 0.000000 | T4histshort | Quiescent current time - history 4 | |
ITBAT | 0x01B8 | STAT_BATTERIETEMPERATUR_IBS_WERT | unsigned int | degC | 0.009237 | -50.000000 | T_batt | Battery temperature | |
IIUBAT | 0x01B9 | STAT_BATTERIESPANNUNG_IBS_WERT | unsigned int | V | 0.000250 | 6.000000 | U_batt | Battery voltage measured by IBS | |
Toel | 0x01BA | STAT_Toel_WERT | unsigned int | degC | 0.005417 | -100.000000 | Toel | Output value engine oil temperature for LoCAN | |
Layer_stLPCOff | 0x01BB | STAT_Layer_stLPCOff_WERT | unsigned char | - | 1.000000 | 0.000000 | Layer_stLPCOff | Status - low pressure control shutdown | |
IIGEN | 0x01BC | STAT_GENERATOR_STROM_WERT | unsigned char | A | 1.000000 | 0.000000 | I_gen | Generator current | |
Rf | 0x01BD | STAT_Rf_WERT | unsigned int | % | 0.010000 | 0.000000 | Rf | relative filling | |
Stat_entl | 0x01BE | STAT_Stat_entl_WERT | unsigned char | - | 1.000000 | 0.000000 | Stat_entl | Status - discharge | |
Pr_bn_soll | 0x01BF | STAT_Pr_bn_soll_WERT | unsigned char | - | 1.000000 | 0.000000 | Pr_bn_soll | Set priority | |
U_bn_soll | 0x01C0 | STAT_U_bn_soll_WERT | unsigned char | V | 0.100000 | 0.000000 | U_bn_soll | On-board voltage - setpoint | |
T1histshort | 0x01C1 | STAT_T1histshort_WERT | unsigned char | min | 14.933333 | 0.000000 | T1histshort | T1histiruh in sec | |
IIMRV | 0x01C2 | STAT_STROM_MENGENREGELVENTIL_WERT | unsigned int | mA | 0.100000 | 0.000000 | MeUn_iActFlt_mp | Flow control valve - current setpoint from rail pressure control | |
SIMRV | 0x01C3 | STAT_STROM_MENGENREGELVENTIL_SOLL_WERT | unsigned int | mA | 0.100000 | 0.000000 | MeUn_iSet | Flow control valve - setpoint of the control current | |
IAMRV | 0x01C4 | STAT_MENGENREGELVENTIL_ANSTEUERUNG_WERT | unsigned int | % | 0.001526 | 0.000000 | MeUn_rPs_mp | Flow control valve - output duty cycle | |
SVRDR | 0x01C5 | STAT_VOLUMENSTROM_RAILDRUCKREGELUNG_SOLL_WERT | unsigned int | mm3/s | 0.003052 | -100.000000 | MeUn_dvolSet | Flow control valve - flow setpoint from rail pressure control | |
MeUn_uRaw_mp | 0x01C6 | STAT_MeUn_uRaw_mp_WERT | unsigned int | mV | 0.076295 | 0.000000 | MeUn_uRaw_mp | Flow control valve - raw voltage value | |
MeUn_stActrCtl_mp | 0x01CA | STAT_MeUn_stActrCtl_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | MeUn_stActrCtl_mp | Flow control valve - state of the actuating value control | |
MeUn_iActVal | 0x01CB | STAT_MeUn_iActVal_WERT | unsigned int | mA | 0.100000 | 0.000000 | MeUn_iActVal | Flow control valve - actual current value | |
Ibs_errors | 0x01D3 | STAT_Ibs_errors_WERT | unsigned char | - | 1.000000 | 0.000000 | Ibs_errors | IBS error status (IBS internal) | |
MisfDet_ctMifDrivCyc_0 | 0x01D6 | STAT_MisfDet_ctMifDrivCyc0_WERT | unsigned int | - | 1.000000 | 0.000000 | MisfDet_ctMifDrivCyc_0 | Counter for the misfires in the current drive cycle, vector with one element per cylinder 0 | |
MisfDet_ctMifDrivCyc_1 | 0x01D7 | STAT_MisfDet_ctMifDrivCyc1_WERT | unsigned int | - | 1.000000 | 0.000000 | MisfDet_ctMifDrivCyc_1 | Counter for the misfires in the current drive cycle, vector with one element per cylinder 1 | |
MisfDet_ctMifDrivCyc_2 | 0x01D8 | STAT_MisfDet_ctMifDrivCyc2_WERT | unsigned int | - | 1.000000 | 0.000000 | MisfDet_ctMifDrivCyc_2 | Counter for the misfires in the current driving cycle, vector with one element per cylinder 2 | |
MisfDet_ctMifDrivCyc_3 | 0x01D9 | STAT_MisfDet_ctMifDrivCyc3_WERT | unsigned int | - | 1.000000 | 0.000000 | MisfDet_ctMifDrivCyc_3 | Counter for the misfires in the current driving cycle, vector with one element per cylinder 3 | |
MisfDet_ctMifDrivCyc_4 | 0x01DA | STAT_MisfDet_ctMifDrivCyc4_WERT | unsigned int | - | 1.000000 | 0.000000 | MisfDet_ctMifDrivCyc_4 | Counter for the misfires in the current driving cycle, vector with one element per cylinder 4 | |
MisfDet_ctMifDrivCyc_5 | 0x01DB | STAT_MisfDet_ctMifDrivCyc5_WERT | unsigned int | - | 1.000000 | 0.000000 | MisfDet_ctMifDrivCyc_5 | Counter for the misfires in the current driving cycle, vector with one element per cylinder 5 | |
MisfDet_ctMifEWMA_mp_0 | 0x01DE | STAT_MisfDet_ctMifEWMA_mp0_WERT | unsigned int | - | 1.000000 | 0.000000 | MisfDet_ctMifEWMA_mp_0 | Counter for the average (EWMA) values for the last ten driving cycles, one measuring point for each cylinder 0 | |
MisfDet_ctMifEWMA_mp_1 | 0x01DF | STAT_MisfDet_ctMifEWMA_mp1_WERT | unsigned int | - | 1.000000 | 0.000000 | MisfDet_ctMifEWMA_mp_1 | Counter for the average (EWMA) values for the last ten driving cycles, one measuring point for each cylinder 1 | |
MisfDet_ctMifEWMA_mp_2 | 0x01E0 | STAT_MisfDet_ctMifEWMA_mp2_WERT | unsigned int | - | 1.000000 | 0.000000 | MisfDet_ctMifEWMA_mp_2 | Counter for the average (EWMA) values for the last ten driving cycles, one measuring point for each cylinder 2 | |
MisfDet_ctMifEWMA_mp_3 | 0x01E1 | STAT_MisfDet_ctMifEWMA_mp3_WERT | unsigned int | - | 1.000000 | 0.000000 | MisfDet_ctMifEWMA_mp_3 | Counter for the average (EWMA) values for the last ten driving cycles, one measuring point for each cylinder 3 | |
MisfDet_ctMifEWMA_mp_4 | 0x01E2 | STAT_MisfDet_ctMifEWMA_mp4_WERT | unsigned int | - | 1.000000 | 0.000000 | MisfDet_ctMifEWMA_mp_4 | Counter for the average (EWMA) values for the last ten driving cycles, one measuring point for each cylinder 4 | |
MisfDet_ctMifEWMA_mp_5 | 0x01E3 | STAT_MisfDet_ctMifEWMA_mp5_WERT | unsigned int | - | 1.000000 | 0.000000 | MisfDet_ctMifEWMA_mp_5 | Counter for the average (EWMA) values for the last ten driving cycles, one measuring point for each cylinder 5 | |
SPLAD | 0x01F4 | STAT_LADEDRUCK_SOLL_WERT | unsigned int | hPa | 0.091554 | 0.000000 | PCR_pDesVal | Boost pressure setpoint | |
PCR_pDesValLP | 0x01F6 | STAT_PCR_pDesValLP_WERT | unsigned int | hPa | 1.000000 | 0.000000 | PCR_pDesValLP | Boost pressure setpoint (low pressure stage) | |
PCR_pDesBas_mp | 0x01F7 | STAT_PCR_pDesBas_mp_WERT | unsigned int | hPa | 1.000000 | 0.000000 | PCR_pDesBas_mp | Basic boost pressure setpoint | |
PCR_pDesBasLP_mp | 0x01F8 | STAT_PCR_pDesBasLP_mp_WERT | unsigned int | hPa | 1.000000 | 0.000000 | PCR_pDesBasLP_mp | Basic boost pressure setpoint (low-pressure stage) | |
PCR_pGovDvt | 0x01F9 | STAT_PCR_pGovDvt_WERT | unsigned int | hPa | 0.999985 | -32767.000000 | PCR_pGovDvt | Control deviation of the boost pressure regulator | |
PCR_pGovDvtLP | 0x01FA | STAT_PCR_pGovDvtLP_WERT | unsigned int | hPa | 0.999985 | -32767.000000 | PCR_pGovDvtLP | Control deviation of the boost pressure regulator (low pressure stage) | |
ISLDR | 0x01FB | STAT_STATUS_ABSCHALTUNG_LADEDRUCKREGELUNG_WERT | unsigned char | - | 1.000000 | 0.000000 | PCR_stMon | Active deactivation of the boost pressure monitor | |
PCR_stMonLP | 0x01FC | STAT_PCR_stMonLP_WERT | unsigned char | - | 1.000000 | 0.000000 | PCR_stMonLP | active deactivation of the boost pressure monitoring (low pressure stage) | |
PCR_stNrmOp_mp | 0x01FD | STAT_PCR_stNrmOp_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | PCR_stNrmOp_mp | normal operation of the boost pressure control | |
PCR_stNrmOpLP_mp | 0x01FE | STAT_PCR_stNrmOpLP_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | PCR_stNrmOpLP_mp | normal operation of the boost pressure control (low pressure stage) | |
PCR_stWrkSph_mp | 0x01FF | STAT_PCR_stWrkSph_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | PCR_stWrkSph_mp | Current operating range of the boost pressure control | |
PCR_stWrkSphLP_mp | 0x0200 | STAT_PCR_stWrkSphLP_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | PCR_stWrkSphLP_mp | Current operating range of the boost pressure control (low pressure stage) | |
PCR_stPCRBits | 0x0201 | STAT_PCR_stPCRBits_WERT | unsigned long | - | 1.000000 | 0.000000 | PCR_stPCRBits | Shutdowns of the boost pressure control | |
PCR_stPCRBitsLP | 0x0202 | STAT_PCR_stPCRBitsLP_WERT | unsigned long | - | 1.000000 | 0.000000 | PCR_stPCRBitsLP | Cut-offs of the boost pressure control (low pressure stage) | |
PCR_rCtlVal | 0x0203 | STAT_PCR_rCtlVal_WERT | unsigned int | % | 0.012207 | 0.000000 | PCR_rCtlVal | Boost pressure control proportion of the manipulated variable | |
PCR_stDesValSysTst | 0x0204 | STAT_PCR_stDesValSysTst_WERT | unsigned char | - | 1.000000 | 0.000000 | PCR_stDesValSysTst | Air system test status (0=new, 1=old) | |
MeUn_dvolAdaptCrvPntNew_mp_0 | 0x0208 | STAT_MeUn_dvolAdaptCrvPntNew_mp_0_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvPntNew_mp_0 | Flow control valve - control points of the new adaptive characteristic 0 | |
MeUn_dvolAdaptCrvPntNew_mp_1 | 0x0209 | STAT_MeUn_dvolAdaptCrvPntNew_mp_1_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvPntNew_mp_1 | Flow control valve - control points of the new adaptive characteristic 1 | |
MeUn_dvolAdaptCrvPntNew_mp_2 | 0x020A | STAT_MeUn_dvolAdaptCrvPntNew_mp_2_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvPntNew_mp_2 | Flow control valve - positions of the new adaptive characteristic 2 | |
MeUn_dvolAdaptCrvPntNew_mp_3 | 0x020B | STAT_MeUn_dvolAdaptCrvPntNew_mp_3_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvPntNew_mp_3 | Flow control valve - positions of the new adaptive characteristic curve 3 | |
MeUn_dvolAdaptCrvPntNew_mp_4 | 0x020C | STAT_MeUn_dvolAdaptCrvPntNew_mp_4_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvPntNew_mp_4 | Flow control valve - points of the new adaptive characteristic 4 | |
MeUn_dvolAdaptCrvPntNew_mp_5 | 0x020D | STAT_MeUn_dvolAdaptCrvPntNew_mp_5_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvPntNew_mp_5 | Flow control valve â€" control points of the new adaptive characteristic curve 5 | |
MeUn_dvolAdaptCrvPntNew_mp_6 | 0x020E | STAT_MeUn_dvolAdaptCrvPntNew_mp_6_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvPntNew_mp_6 | Flow control valve â€" control points of the new adaptive characteristic curve 6 | |
MeUn_dvolAdaptCrvPntNew_mp_7 | 0x020F | STAT_MeUn_dvolAdaptCrvPntNew_mp_7_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvPntNew_mp_7 | Flow control valve - positions of the new adaptive characteristic 7 | |
MeUn_dvolAdaptCrvPntNew_mp_8 | 0x0210 | STAT_MeUn_dvolAdaptCrvPntNew_mp_8_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvPntNew_mp_8 | Flow control valve - points of the new adaptive characteristic 8 | |
MeUn_dvolAdaptCrvPntNew_mp_9 | 0x0211 | STAT_MeUn_dvolAdaptCrvPntNew_mp_9_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvPntNew_mp_9 | Flow control valve - control points of the new adaptive characteristic 9 | |
MeUn_dvolAdaptCrvValNew_mp_0 | 0x0212 | STAT_MeUn_dvolAdaptCrvValNew_mp_0_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvValNew_mp_0 | Flow control valve - characteristic values of the new adaptive characteristic 0 | |
MeUn_dvolAdaptCrvValNew_mp_1 | 0x0213 | STAT_MeUn_dvolAdaptCrvValNew_mp_1_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvValNew_mp_1 | Flow control valve - characteristic values of the new adaptive characteristic 1 | |
MeUn_dvolAdaptCrvValNew_mp_2 | 0x0214 | STAT_MeUn_dvolAdaptCrvValNew_mp_2_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvValNew_mp_2 | Flow control valve - characteristic values of the new adaptive characteristic 2 | |
MeUn_dvolAdaptCrvValNew_mp_3 | 0x0215 | STAT_MeUn_dvolAdaptCrvValNew_mp_3_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvValNew_mp_3 | Flow control valve - characteristic curve values of the new adaptive characteristic curve 3 | |
MeUn_dvolAdaptCrvValNew_mp_4 | 0x0216 | STAT_MeUn_dvolAdaptCrvValNew_mp_4_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvValNew_mp_4 | Flow control valve - characteristic curve values of the new adaptive characteristic curve 4 | |
MeUn_dvolAdaptCrvValNew_mp_5 | 0x0217 | STAT_MeUn_dvolAdaptCrvValNew_mp_5_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvValNew_mp_5 | Flow control valve - characteristic values of the new adaptive characteristic 5 | |
MeUn_dvolAdaptCrvValNew_mp_6 | 0x0218 | STAT_MeUn_dvolAdaptCrvValNew_mp_6_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvValNew_mp_6 | Flow control valve - characteristic values of the new adaptive characteristic 6 | |
MeUn_dvolAdaptCrvValNew_mp_7 | 0x0219 | STAT_MeUn_dvolAdaptCrvValNew_mp_7_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvValNew_mp_7 | Flow control valve - characteristic curve values of the new adaptive characteristic 7 | |
MeUn_dvolAdaptCrvValNew_mp_8 | 0x021A | STAT_MeUn_dvolAdaptCrvValNew_mp_8_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvValNew_mp_8 | Flow control valve - characteristic values of the new adaptive characteristic 8 | |
MeUn_dvolAdaptCrvValNew_mp_9 | 0x021B | STAT_MeUn_dvolAdaptCrvValNew_mp_9_WERT | unsigned int | mm3/s | 0.999985 | -32767.000000 | MeUn_dvolAdaptCrvValNew_mp_9 | Flow control valve - characteristic values of the new adaptive characteristic 9 | |
PCV_facAdapt | 0x0258 | STAT_PCV_facAdapt_WERT | unsigned int | - | 0.000031 | 0.000000 | PCV_facAdapt | Rail pressure control valve - adaptation factor for the characteristic curve | |
PCV_iActFlt_mp | 0x0259 | STAT_PCV_iActFlt_mp_WERT | unsigned int | mA | 0.061036 | 0.000000 | PCV_iActFlt_mp | Rail pressure control valve - actual current value filtered | |
PCV_uRaw_mp | 0x025A | STAT_PCV_uRaw_mp_WERT | unsigned int | mV | 0.076295 | 0.000000 | PCV_uRaw_mp | Rail pressure control valve - setpoint duty cycle | |
IARDS | 0x025B | STAT_RAILDRUCKREGELVENTIL_ANSTEUERUNG_WERT | unsigned int | % | 0.001526 | 0.000000 | PCV_rPs | Rail pressure control valve - output duty cycle | |
PCV_iSet | 0x025C | STAT_PCV_iSet_WERT | unsigned int | mA | 1.000000 | 0.000000 | PCV_iSet | Rail pressure control valve - setpoint of the actuating current | |
PCV_pSet | 0x025D | STAT_PCV_pSet_WERT | unsigned int | bar | 0.045777 | 0.000000 | PCV_pSet | Rail pressure control valve - pressure setpoint from rail pressure control | |
PCV_stActrCtl | 0x025F | STAT_PCV_stActrCtl_WERT | unsigned char | - | 1.000000 | 0.000000 | PCV_stActrCtl | Rail pressure control valve - status of the actuating value control | |
PCV_stAdapt | 0x0263 | STAT_PCV_stAdapt_WERT | unsigned char | - | 1.000000 | 0.000000 | PCV_stAdapt | Status of the status automaton of the adaptation function | |
PCV_pAdaptThres_mp | 0x0264 | STAT_PCV_pAdaptThres_mp_WERT | unsigned int | bar | 0.045777 | 0.000000 | PCV_pAdaptThres_mp | Rail pressure threshold for calculating the adaptation factor | |
PCV_iActVal | 0x0265 | STAT_PCV_iActVal_WERT | unsigned int | mA | 0.061036 | 0.000000 | PCV_iActVal | Rail pressure control valve - actual current value | |
PCV_ctAdaptSum_mp | 0x0267 | STAT_PCV_ctAdaptSum_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | PCV_ctAdaptSum_mp | Counter for the number of function calls of the PCV adaptation in the state PCV_ADAPT_SUM_UP | |
PCV_facAdaptFlow | 0x0268 | STAT_PCV_facAdaptFlow_WERT | unsigned int | - | 0.000122 | 0.000000 | PCV_facAdaptFlow | Factor for estimating the flow through the PCV | |
FlFltDsP_pSens | 0x02DA | STAT_FlFltDsP_pSens_WERT | unsigned int | hPa | 0.100000 | 0.000000 | FlFltDsP_pSens | Fuel feed pressure - sensor value | |
FlFltDsP_uRaw | 0x02DB | STAT_FlFltDsP_uRaw_WERT | unsigned int | mV | 0.076295 | 0.000000 | FlFltDsP_uRaw | Fuel feed pressure - raw voltage value from sensor | |
FlFltDsP_p | 0x02DC | STAT_FlFltDsP_p_WERT | unsigned int | hPa | 1.000000 | 0.000000 | FlFltDsP_p | Fuel feed pressure - filtered | |
FlFltHt_stPs | 0x02F8 | STAT_FlFltHt_stPs_WERT | unsigned char | - | 1.000000 | 0.000000 | FlFltHt_stPs | Status of the diesel filter heater | |
Dfh_pekpf | 0x0320 | STAT_Dfh_pekpf_WERT | unsigned int | W | 0.100000 | 0.000000 | Dfh_pekpf | Power EKP (U*I) filtered | |
PSP_dvolOut | 0x0321 | STAT_PSP_dvolOut_WERT | unsigned int | l/h | 0.003891 | 0.000000 | PSP_dvolOut | Flow rate | |
Uekp | 0x0324 | STAT_Uekp_WERT | unsigned char | V | 0.100000 | 0.000000 | Uekp | Voltage EKP | |
Dfh_lerncnt | 0x0325 | STAT_Dfh_lerncnt_WERT | unsigned int | - | 1.000000 | 0.000000 | Dfh_lerncnt | Counter for the diesel filter heater learning function | |
Dfh_lernpw | 0x0326 | STAT_Dfh_lernpw_WERT | unsigned int | W | 0.100000 | 0.000000 | Dfh_lernpw | Learned power of the EKP to control the diesel filter heater | |
Iekp | 0x0327 | STAT_Iekp_WERT | unsigned char | A | 0.100000 | 0.000000 | Iekp | Current EKP | |
BMWdfh_rat_EfpPwmLrnd_sw | 0x0328 | STAT_BMWdfh_rat_EfpPwmLrnd_sw_WERT | unsigned int | % | 0.030518 | -1000.000000 | BMWdfh_rat_EfpPwmLrnd_sw | Control value of FPC for EKP | |
BMWdfh_ct_EfpLrnFct_uw | 0x032A | STAT_BMWdfh_ct_EfpLrnFct_uw_WERT | unsigned int | - | 1.000000 | 0.000000 | BMWdfh_ct_EfpLrnFct_uw | Counter for the learn function diesel filter heating | |
BMWdfh_pwr_EfpLrnd_uw | 0x032B | STAT_BMWdfh_pwr_EfpLrnd_uw_WERT | unsigned int | W | 0.100000 | 0.000000 | BMWdfh_pwr_EfpLrnd_uw | Learned power of the EKP for controlling the diesel filter heater | |
BMWlpi_pwr_EfpFild_uw | 0x032C | STAT_BMWlpi_pwr_EfpFild_uw_WERT | unsigned int | W | 0.100000 | 0.000000 | BMWlpi_pwr_EfpFild_uw | Power EKP (U*I) filtered | |
BMWdfh_stb_DfhAcvIf_ub | 0x032D | STAT_BMWdfh_stb_DfhAcvIf_ub_WERT | unsigned char | - | 1.000000 | 0.000000 | BMWdfh_stb_DfhAcvIf_ub | Status word control DFH | |
IFTNK | 0x0384 | STAT_TANKFUELLSTAND_KRAFTSTOFF_WERT | unsigned int | l | 0.001907 | 0.000000 | FuelLvl_vol | Tank level - fuel | |
ITKRS | 0x0385 | STAT_KRAFTSTOFFTEMPERATUR_WERT | unsigned int | degC | 0.010000 | -50.000000 | FuelT_t | Fuel temperature | |
ISKRS | 0x0386 | STAT_KRAFTSTOFFTEMPERATUR_SPANNUNG_ROH_WERT | unsigned int | mV | 0.076295 | 0.000000 | FuelT_uRaw | Voltage raw value - Fuel temperature sensor | |
FuelT_tSens | 0x0389 | STAT_FuelT_tSens_WERT | unsigned int | degC | 0.003052 | -50.000000 | FuelT_tSens | Fuel sensor temperature | |
PFlt_stEffEnblPPDs_mp | 0x03DC | STAT_PFlt_stEffEnblPPDs_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | PFlt_stEffEnblPPDs_mp | Particle filter status for particle sensor | |
PFlt_rPFltEff_mp | 0x03DD | STAT_PFlt_rPFltEff_mp_WERT | unsigned int | - | 0.003891 | 0.000000 | PFlt_rPFltEff_mp | Ratio for calculation of DPF monitoring criterion | |
PFltRgn_vAvrgSnceRgn_mp | 0x03DE | STAT_PFltRgn_vAvrgSnceRgn_mp_WERT | unsigned int | km/h | 0.003815 | 0.000000 | PFltRgn_vAvrgSnceRgn_mp | Average speed since last successful regeneration | |
PFlt_tiRgnTot | 0x03DF | STAT_PFlt_tiRgnTot_WERT | unsigned int | s | 23.002976 | 0.000000 | PFlt_tiRgnTot | Total operating time of the regenerations | |
Exh_pUnFltPTrbnUs | 0x03E0 | STAT_Exh_pUnFltPTrbnUs_WERT | unsigned int | hPa | 0.038148 | 500.000000 | Exh_pUnFltPTrbnUs | Exhaust gas pressure before turbine - unfiltered | |
PFlt_mSotMeasNoCompl_mp | 0x03E1 | STAT_PFlt_mSotMeasNoCompl_mp_WERT | unsigned int | g | 0.100000 | 0.000000 | PFlt_mSotMeasNoCompl_mp | Measured soot mass | |
PFlt_pDiffMaxStyOfsCor_mp | 0x03E2 | STAT_PFlt_pDiffMaxStyOfsCor_mp_WERT | unsigned int | hPa | 0.039673 | -600.000000 | PFlt_pDiffMaxStyOfsCor_mp | Stationary maximum values of the differential pressure after offset correction | |
PFlt_tPFltUsEff_mp | 0x03E3 | STAT_PFlt_tPFltUsEff_mp_WERT | unsigned int | degC | 0.100000 | -273.140000 | PFlt_tPFltUsEff_mp | Temperatures upstream of the particle filter required for the condition query | |
PFlt_rEngPrtRgn_mp | 0x03E4 | STAT_PFlt_rEngPrtRgn_mp_WERT | unsigned int | % | 0.001526 | 0.000000 | PFlt_rEngPrtRgn_mp | Engine protection Regeneration ratio of feed time and last regeneration time | |
PFlt_pDiffNoDstrMin_mp | 0x03E5 | STAT_PFlt_pDiffNoDstrMin_mp_WERT | unsigned int | hPa | 1.000000 | 0.000000 | PFlt_pDiffNoDstrMin_mp | Minimum differential pressure in overrun dependent on steady-state exhaust gas volume flow for the assumption of a destroyed particulate filter | |
PFlt_pDiffMaxSty_mp | 0x03E6 | STAT_PFlt_pDiffMaxSty_mp_WERT | unsigned int | hPa | 1.000000 | 0.000000 | PFlt_pDiffMaxSty_mp | Stationary maximum values of the differential pressure | |
PFlt_pDiffCharMonMin_mp | 0x03E7 | STAT_PFlt_pDiffCharMonMin_mp_WERT | unsigned int | hPa | 1.000000 | 0.000000 | PFlt_pDiffCharMonMin_mp | Lower limit of DPF characteristic monitoring using differential pressure | |
IVTLR | 0x03E8 | STAT_KRAFTSTOFFVERBRAUCH_SEIT_ERFOLGREICHER_REGENER_WERT | unsigned int | l | 0.010000 | 0.000000 | PFltRgn_qFl_mp | Amount of fuel consumed since last successful regeneration | |
IMASOEL | 0x03E9 | STAT_OELASCHENMASSE_WERT | unsigned int | g | 0.015259 | 0.000000 | PFltLd_mAshOilEG | Oil-ash mass | |
IMRUP | 0x03EA | STAT_RUSSMASSE_IM_PARTIKELFILTER_WERT | unsigned int | g | 0.015259 | 0.000000 | PFltLd_mSot | Soot mass | |
IDSLRE | 0x03EB | STAT_STRECKE_SEIT_ERFOLGREICHER_REGENERATION_WERT | unsigned long | m | 1.000000 | 0.000000 | PFltRgn_lSnceRgn | Distance driven since last successful regeneration | |
ISREU | 0x03EC | STAT_STATUS_REGENERATION_UNTERBROCHEN_WERT | unsigned int | - | 1.000000 | 0.000000 | PFltRgn_stIntr | Status - regeneration interruption | |
IMPAS | 0x03ED | STAT_PARTIKELMASSE_SIMULIERT_WERT | unsigned int | g | 0.010000 | 0.000000 | PFltLd_mSotSim | Simulated rest mass | |
ISRBF | 0x03EE | STAT_REGENERATION_BLOCKIERUNG_UND_FREIGABE_WERT | unsigned char | - | 1.000000 | 0.000000 | PFltRgn_stLck | Status - regeneration interruption | |
PFlt_stPresPlaus_mp | 0x03EF | STAT_PFlt_stPresPlaus_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | PFlt_stPresPlaus_mp | Status - operating range for particle filter pressure plausibility check | |
PFlt_pPreCorr_mp | 0x03F0 | STAT_PFlt_pPreCorr_mp_WERT | unsigned int | hPa | 1.000000 | 0.000000 | PFlt_pPreCorr_mp | Exhaust backpressure before particulate filter - corrected | |
IWSTG | 0x03F1 | STAT_STROEMUNGSWIDERSTAND_GEFILTERT_WERT | unsigned int | hPa/(m^3/h) | 0.000100 | 0.000000 | PFltLd_resFlwFlt | Filtered flow resistance of the particulate filter | |
IKMZWREG | 0x03F3 | STAT_DURCHSCHNITT_KILOMETER_ZWISCHEN_REGENERATIONEN_WERT | unsigned int | km | 1.000000 | 0.000000 | PFlt_lAvrgRgn | Average regeneration interval | |
PFlt_ctRgnStep1_mp | 0x03F5 | STAT_PFlt_ctRgnStep1_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | PFlt_ctRgnStep1_mp | Regeneration counter type 1 | |
PFlt_ctRgnStep2_mp | 0x03F6 | STAT_PFlt_ctRgnStep2_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | PFlt_ctRgnStep2_mp | Regeneration counter type 2 | |
PFlt_ctRgnStep3_mp | 0x03F7 | STAT_PFlt_ctRgnStep3_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | PFlt_ctRgnStep3_mp | Regeneration counter type 3 | |
PFlt_ctRgnStep4_mp | 0x03F8 | STAT_PFlt_ctRgnStep4_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | PFlt_ctRgnStep4_mp | Regeneration counter type 4 | |
PFlt_ctRgnStep5_mp | 0x03F9 | STAT_PFlt_ctRgnStep5_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | PFlt_ctRgnStep5_mp | Regeneration counter type 5 | |
PFlt_ctRgnStep6_mp | 0x03FA | STAT_PFlt_ctRgnStep6_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | PFlt_ctRgnStep6_mp | Regeneration chiller type 6 | |
PFlt_ctRgnStep7_mp | 0x03FB | STAT_PFlt_ctRgnStep7_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | PFlt_ctRgnStep7_mp | Type 7 regeneration chiller | |
PFlt_ctRgnStep8_mp | 0x03FC | STAT_PFlt_ctRgnStep8_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | PFlt_ctRgnStep8_mp | Regeneration counter type 8 | |
IKMRE0 | 0x03FD | STAT_KM_STAND_SEIT_1_ERFOLGREICHEN_REGENERATIONEN_WERT | unsigned long | m | 1.000000 | 0.000000 | PFltRgn_lSumRgnBck0_mp | Vehicle mileage at last regeneration | |
IKMRE1 | 0x03FE | STAT_KM_STAND_SEIT_2_ERFOLGREICHEN_REGENERATIONEN_WERT | unsigned long | m | 1.000000 | 0.000000 | PFltRgn_lSumRgnBck1_mp | Vehicle mileage at the penultimate regeneration | |
IKMRE2 | 0x03FF | STAT_KM_STAND_SEIT_3_ERFOLGREICHEN_REGENERATIONEN_WERT | unsigned long | m | 1.000000 | 0.000000 | PFltRgn_lSumRgnBck2_mp | Vehicle mileage at the third last regeneration | |
IKMRE3 | 0x0400 | STAT_KM_STAND_SEIT_4_ERFOLGREICHEN_REGENERATIONEN_WERT | unsigned long | m | 1.000000 | 0.000000 | PFltRgn_lSumRgnBck3_mp | Vehicle mileage at the fourth last regeneration | |
IKMRE4 | 0x0401 | STAT_KM_STAND_SEIT_5_ERFOLGREICHEN_REGENERATIONEN_WERT | unsigned long | m | 1.000000 | 0.000000 | PFltRgn_lSumRgnBck4_mp | Vehicle mileage at the fifth last regeneration | |
IDSVP | 0x0402 | STAT_DURCHSCHNITT_VERBRAUCH_PRO100KM_WERT | unsigned int | l/100km | 0.050000 | 0.000000 | PFltRgn_dqFlAvrg_mp | Average fuel consumption of the vehicle since last DPF replacement | |
PFltRgn_numRgn | 0x0404 | STAT_PFltRgn_numRgn_WERT | unsigned char | - | 1.000000 | 0.000000 | PFltRgn_numRgn | Status - regeneration request | |
PFltLd_mSotMeas | 0x0405 | STAT_PFltLd_mSotMeas_WERT | unsigned int | g | 0.010000 | 0.000000 | PFltLd_mSotMeas | Particulate matter corrected additively | |
PFltLd_mSotSimCont | 0x0406 | STAT_PFltLd_mSotSimCont_WERT | unsigned int | g | 0.010000 | 0.000000 | PFltLd_mSotSimCont | Continuously simulated particulate mass | |
PFltRgn_ctRgnSucEEP_mp | 0x0407 | STAT_PFltRgn_ctRgnSucEEP_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | PFltRgn_ctRgnSucEEP_mp | Number of successful DPF regenerations | |
PFltRgn_tiSnceRgn | 0x0408 | STAT_PFltRgn_tiSnceRgn_WERT | unsigned long | s | 1.000000 | 0.000000 | PFltRgn_tiSnceRgn | Operating time since last successful regeneration | |
PFltLd_mAshCorOld | 0x0409 | STAT_PFltLd_mAshCorOld_WERT | unsigned int | g | 0.015259 | 0.000000 | PFltLd_mAshCorOld | Ash correction value from previous cycle | |
PFlt_mSotSumMeasFlt_mp | 0x040A | STAT_PFlt_mSotSumMeasFlt_mp_WERT | unsigned int | g | 0.010000 | 0.000000 | PFlt_mSotSumMeasFlt_mp | digitally filtered value of the measured soot mass | |
PFlt_dvolMaxSty_mp | 0x040B | STAT_PFlt_dvolMaxSty_mp_WERT | unsigned int | m^3/h | 0.100000 | 0.000000 | PFlt_dvolMaxSty_mp | Maximum steady-state exhaust gas volume flow for checking the maximum differential pressure in the overrun | |
PFlt_mSotNoComplMax_mp | 0x040C | STAT_PFlt_mSotNoComplMax_mp_WERT | unsigned int | g | 0.010000 | 0.000000 | PFlt_mSotNoComplMax_mp | Map for determining the monitoring limit | |
PFlt_mSotSumMeasActEff_mp | 0x040D | STAT_PFlt_mSotSumMeasActEff_mp_WERT | unsigned int | g | 0.010000 | 0.000000 | PFlt_mSotSumMeasActEff_mp | Soot mass integral of the measured value (filtered) | |
PFlt_mSotSumMeasActEffFlt_mp | 0x040E | STAT_PFlt_mSotSumMeasActEffFlt_mp_WERT | unsigned int | g | 0.010000 | 0.000000 | PFlt_mSotSumMeasActEffFlt_mp | Soot mass integral of the measured value | |
PFlt_mSotSumSimActEff_mp | 0x040F | STAT_PFlt_mSotSumSimActEff_mp_WERT | unsigned int | g | 0.010000 | 0.000000 | PFlt_mSotSumSimActEff_mp | Result of the summation of the simulated value | |
Exh_pDiffTrbnUsIntkVUs | 0x0410 | STAT_Exh_pDiffTrbnUsIntkVUs_WERT | unsigned int | hPa | 0.030518 | -1000.000000 | Exh_pDiffTrbnUsIntkVUs | newly learned relative deviation of pressure before turbine to boost pressure | |
Exh_pDiffTrbnUsIntkVUsAct | 0x0411 | STAT_Exh_pDiffTrbnUsIntkVUsAct_WERT | unsigned int | hPa | 0.030518 | -1000.000000 | Exh_pDiffTrbnUsIntkVUsAct | relative deviation from pressure before turbine to boost pressure | |
Exh_pDiffTrbnUsIntkVUsOld | 0x0412 | STAT_Exh_pDiffTrbnUsIntkVUsOld_WERT | unsigned int | hPa | 0.030518 | -1000.000000 | Exh_pDiffTrbnUsIntkVUsOld | old learned relative deviation from pressure before turbine to boost pressure | |
Exh_pSensFieldPTrbnUs_0 | 0x0413 | STAT_Exh_pSensFieldPTrbnUs0_WERT | unsigned int | hPa | 0.038148 | 500.000000 | Exh_pSensFieldPTrbnUs_0 | Ring buffer of the stored sensor values after release of the plausibility checks 0 | |
Exh_pSensFieldPTrbnUs_1 | 0x0414 | STAT_Exh_pSensFieldPTrbnUs1_WERT | unsigned int | hPa | 0.038148 | 500.000000 | Exh_pSensFieldPTrbnUs_1 | Ring buffer of the stored sensor values after release of the plausibility checks 1 | |
Exh_pSensFieldPTrbnUs_2 | 0x0415 | STAT_Exh_pSensFieldPTrbnUs2_WERT | unsigned int | hPa | 0.038148 | 500.000000 | Exh_pSensFieldPTrbnUs_2 | Ring buffer of the stored sensor values after release of the plausibility checks 2 | |
Exh_pSensFieldPTrbnUs_3 | 0x0416 | STAT_Exh_pSensFieldPTrbnUs3_WERT | unsigned int | hPa | 0.038148 | 500.000000 | Exh_pSensFieldPTrbnUs_3 | Ring buffer of the stored sensor values after release of the plausibility checks 3 | |
Exh_pSensFieldPTrbnUs_4 | 0x0417 | STAT_Exh_pSensFieldPTrbnUs4_WERT | unsigned int | hPa | 0.038148 | 500.000000 | Exh_pSensFieldPTrbnUs_4 | Ring buffer of the stored sensor values after release of the plausibility checks 4 | |
Exh_pSensFieldPTrbnUs_5 | 0x0418 | STAT_Exh_pSensFieldPTrbnUs5_WERT | unsigned int | hPa | 0.038148 | 500.000000 | Exh_pSensFieldPTrbnUs_5 | Ring buffer of the stored sensor values after release of the plausibility checks 5 | |
Exh_pSensMeanPTrbnUs | 0x0419 | STAT_Exh_pSensMeanPTrbnUs_WERT | unsigned int | hPa | 0.038148 | 500.000000 | Exh_pSensMeanPTrbnUs | Mean value of the sensor values of the ring buffer after release delay | |
Exh_pDiffOfsValOld | 0x041A | STAT_Exh_pDiffOfsValOld_WERT | unsigned int | hPa | 0.030518 | -1000.000000 | Exh_pDiffOfsValOld | Exh_pDiffOfsValOld | |
ITAVP1 | 0x041B | STAT_ABGASTEMPERATUR_VOR_PARTIKELFILTER_1_WERT | unsigned int | degC | 0.031281 | -50.000000 | Exh_tPFltUs | Exhaust gas temperature before particulate filter - corrected value | |
RUPVP | 0x041C | STAT_ABGASDRUCK_VOR_PARTIKELFILTER_SPANNUNG_ROH_WERT | unsigned int | mV | 0.076295 | 0.000000 | Exh_uRawPPFltUs | Raw voltage value - exhaust gas pressure before particulate filter | |
RUTVP | 0x041D | STAT_ABGASTEMPERATUR_VOR_PARTIKELFILTER_SPANNUNG_ROH_WERT | unsigned int | mV | 0.076295 | 0.000000 | Exh_uRawTPFltUs | Exhaust gas temperature before particulate filter - raw value | |
ITAVO | 0x041E | STAT_ABGASTEMPERATUR_VOR_KATALYSATOR_WERT | unsigned int | degC | 0.031281 | -50.000000 | Exh_tOxiCatUs | Exhaust gas temperature before catalyst - corrected value | |
Exh_uRawTOxiCatUs | 0x041F | STAT_Exh_uRawTOxiCatUs_WERT | unsigned int | mV | 0.076295 | 0.000000 | Exh_uRawTOxiCatUs | Exhaust gas temperature before catalyst - raw value | |
Exh_pPFltUs | 0x0420 | STAT_Exh_pPFltUs_WERT | unsigned int | hPa | 0.091554 | 0.000000 | Exh_pPFltUs | Exhaust pressure upstream of particulate filter | |
IPDIP | 0x0424 | STAT_DIFFERENZDRUCK_UEBER_PARTIKELFILTER_WERT | unsigned int | hPa | 0.045777 | -1000.000000 | Exh_pAdapPPFltDiff | Corrected differential pressure | |
Exh_pFltPPFltDiff | 0x0426 | STAT_Exh_pFltPPFltDiff_WERT | unsigned int | hPa | 0.045777 | -1000.000000 | Exh_pFltPPFltDiff | filtered differential pressure of the particulate filter | |
Exh_pDiffOfsValAct | 0x0428 | STAT_Exh_pDiffOfsValAct_mp_WERT | unsigned int | hPa | 0.030518 | -1000.000000 | Exh_pDiffOfsValAct | Offset for particulate filter differential pressure | |
Exh_pRawAdapPPFltDiff | 0x042A | STAT_Exh_pRawAdapPPFltDiff_WERT | unsigned int | hPa | 0.045777 | -1000.000000 | Exh_pRawAdapPPFltDiff | Raw value of the corrected absolute backpressure | |
Exh_tSensTOxiCatUs | 0x042C | STAT_Exh_tSensTOxiCatUs_WERT | unsigned int | degC | 0.031281 | -50.000000 | Exh_tSensTOxiCatUs | Exhaust gas temperature before catalytic converter | |
Exh_tSensTPFltUs | 0x042E | STAT_Exh_tSensTPFltUs_WERT | unsigned int | degC | 0.031281 | -50.000000 | Exh_tSensTPFltUs | Exhaust gas temperature before particulate filter | |
Exh_pAdapPPFltUs | 0x0430 | STAT_Exh_pAdapPPFltUs_WERT | unsigned int | hPa | 0.100000 | 0.000000 | Exh_pAdapPPFltUs | Corrected absolute backpressure of the particulate filter | |
IPABG1 | 0x0432 | STAT_ABGASDRUCK_VOR_PARTIKELFILTER_1_WERT | unsigned int | hPa | 0.100000 | 0.000000 | Exh_pFltPPFltUs | Absolute pressure upstream of particulate filter | |
Exh_tAdapTPFltUs | 0x0434 | STAT_Exh_tAdapTPFltUs_WERT | unsigned int | degC | 0.031281 | -50.000000 | Exh_tAdapTPFltUs | Adjusted temperature before particulate filter | |
Exh_dpModPTrbnUs_mp | 0x0436 | STAT_Exh_dpModPTrbnUs_mp_WERT | unsigned int | hPa/s | 0.100000 | 0.000000 | Exh_dpModPTrbnUs_mp | Exh_dpModPTrbnUs_mp | |
Exh_dpSensPTrbnUs_mp | 0x0437 | STAT_Exh_dpSensPTrbnUs_mp_WERT | unsigned int | hPa/s | 0.100000 | 0.000000 | Exh_dpSensPTrbnUs_mp | Exh_dpSensPTrbnUs_mp | |
Exh_stDynNplPTrbnUs_mp | 0x0438 | STAT_Exh_stDynNplPTrbnUs_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | Exh_stDynNplPTrbnUs_mp | Exh_stDynNplPTrbnUs_mp | |
Exh_uRawPPFltDiff | 0x0439 | STAT_Exh_uRawPPFltDiff_WERT | unsigned int | mV | 0.076295 | 0.000000 | Exh_uRawPPFltDiff | Raw voltage value of the pDiff sensor (from the ADC) | |
Exh_pSensPPFltDiff | 0x043A | STAT_Exh_pSensPPFltDiff_WERT | unsigned int | hPa | 0.038148 | 500.000000 | Exh_pSensPPFltDiff | measured differential pressure after the particle filter | |
Exh_pSensPPFltUs | 0x043B | STAT_Exh_pSensPPFltUs_WERT | unsigned int | hPa | 0.038148 | 500.000000 | Exh_pSensPPFltUs | Measured pressure before the particle filter | |
Exh_pPFltDiff | 0x043C | STAT_Exh_pPFltDiff_WERT | unsigned int | hPa | 0.045777 | -1000.000000 | Exh_pPFltDiff | Differential pressure at the particle filter | |
Exh_uRawPTrbnUs | 0x043D | STAT_Exh_uRawPTrbnUs_WERT | unsigned int | mV | 0.076295 | 0.000000 | Exh_uRawPTrbnUs | Raw voltage value for pressure before compressor (from ADC) | |
Exh_pTrbnUs | 0x043E | STAT_Exh_pTrbnUs_WERT | unsigned int | hPa | 0.038148 | 500.000000 | Exh_pTrbnUs | Pressure before turbine | |
ExhFlpLP_r | 0x0442 | STAT_ExhFlpLP_r_WERT | unsigned int | % | 0.001526 | 0.000000 | ExhFlpLP_r | Duty cycle of the exhaust gas throttle valve (set point) | |
ExhFlpLP_rPs | 0x0444 | STAT_ExhFlpLP_rPs_WERT | unsigned int | % | 0.001526 | 0.000000 | ExhFlpLP_rPs | Exhaust throttle - output duty cycle | |
Exh_stAftRunRlsPTrbnUs_mp | 0x0446 | STAT_Exh_stAftRunRlsPTrbnUs_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | Exh_stAftRunRlsPTrbnUs_mp | Status release delay in the run-on of the plausibility checks | |
Exh_stPlsTstRlsPTrbnUs_mp | 0x0448 | STAT_Exh_stPlsTstRlsPTrbnUs_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | Exh_stPlsTstRlsPTrbnUs_mp | Status release of plausibility check with ambient pressure | |
Exh_pTrbnUs_full | 0x0449 | STAT_Exh_pTrbnUs_full_WERT | unsigned int | hPa | 1.000000 | 0.000000 | Exh_pTrbnUs | Pressure before turbine (full range of values) | |
Exh_pUnFltPTrbnUs_full | 0x044A | STAT_Exh_pUnFltPTrbnUs_full_WERT | unsigned int | hPa | 1.000000 | 0.000000 | Exh_pUnFltPTrbnUs | Absolute pressure before turbine (full range of values) | |
Oz_oelkm | 0x044C | STAT_Oz_oelkm_WERT | unsigned int | km | 10.000000 | 0.000000 | Oz_oelkm | Oil kilometre | |
Oz_nivlangt | 0x044D | STAT_Oz_nivlangt_WERT | unsigned char | mm | 0.292969 | 0.000000 | Oz_nivlangt | Long-mean value level for the tester | |
Oz_orikor | 0x044E | STAT_Oz_orikor_WERT | unsigned char | mm | 0.292969 | 0.000000 | Oz_orikor | OriMw corrected | |
IFSOE | 0x044F | STAT_FUELLSTAND_MOTOROEL_KURZZEIT_WERT | unsigned char | mm | 0.292969 | 0.000000 | Oz_nivkrzt | Short average level for the tester | |
Oz_kvbmw | 0x0450 | STAT_Oz_kvbmw_WERT | unsigned long | ul | 0.000122 | 0.000000 | Oz_kvbmw | Average fuel consumption | |
Oz_kvbsm | 0x0452 | STAT_Oz_kvbsm_WERT | unsigned long | ul | 0.000122 | 0.000000 | Oz_kvbsm | Amount of fuel consumed | |
Oz_kvbsm_ul | 0x0453 | STAT_Oz_kvbsm_ul_WERT | unsigned long | ul | 0.000122 | 0.000000 | Oz_kvbsm_ul | Summed fuel quantity | |
Oz_lp | 0x0454 | STAT_Oz_lp_WERT | unsigned char | - | 1.000000 | 0.000000 | Oz_lp | Oil level display image | |
Oz_lv | 0x0455 | STAT_Oz_lv_WERT | unsigned char | - | 1.000000 | 0.000000 | Oz_lv | Oz level value | |
Oz_lf1c | 0x0456 | STAT_Oz_lf1c_WERT | unsigned char | - | 0.010000 | 0.000000 | Oz_lf1c | Country factor 1 coded | |
Oz_lf2c | 0x0457 | STAT_Oz_lf2c_WERT | unsigned char | - | 0.010000 | 0.000000 | Oz_lf2c | Country factor 2 coded | |
ITOEL | 0x0458 | STAT_MOTOROEL_TEMPERATUR_WERT | unsigned int | degC | 0.010000 | -100.000000 | Oz_tempf | Filtered oil temperature | |
Oz_vormw | 0x0459 | STAT_Oz_vormw_WERT | unsigned char | mm | 0.292969 | 0.000000 | Oz_vormw | average level value brought forward | |
Oz_peil | 0x045A | STAT_Oz_peil_WERT | unsigned char | mm | 0.292969 | 0.000000 | Oz_peil | Level value for dipstick display | |
Oz_peilaltanz | 0x045B | STAT_Oz_peilaltanz_WERT | unsigned char | mm | 0.292969 | 0.000000 | Oz_peilaltanz | Old level value before engine shutdown | |
Oz_peillang | 0x045C | STAT_Oz_peillang_WERT | unsigned char | mm | 0.292969 | 0.000000 | Oz_peillang | Last requested value for dipstick display | |
Oz_lf1t | 0x0461 | STAT_Oz_lf1t_WERT | unsigned char | - | 0.010000 | 0.000000 | Oz_lf1t | Country factor 1 | |
Oz_lf2t | 0x0462 | STAT_Oz_lf2t_WERT | unsigned char | - | 0.010000 | 0.000000 | Oz_lf2t | Country factor 2 | |
St_cbsozin0 | 0x0463 | STAT_St_cbsozin0_WERT | unsigned char | - | 1.000000 | 0.000000 | St_cbsozin0 | Status word | |
St_cbsozin1 | 0x0464 | STAT_St_cbsozin1_WERT | unsigned char | - | 1.000000 | 0.000000 | St_cbsozin1 | Status word | |
St_cbsozin_nv0 | 0x0465 | STAT_St_cbsozin_nv0_WERT | unsigned char | - | 1.000000 | 0.000000 | St_cbsozin_nv0 | Status word | |
Oz_manipt | 0x0466 | STAT_Oz_manipt_WERT | unsigned char | - | 1.000000 | 0.000000 | Oz_manipt | Tamper detection BOS values | |
Id_bosrtt | 0x0467 | STAT_Id_bosrtt_WERT | unsigned char | - | 1.000000 | 0.000000 | Id_bosrtt | ID for BOS reset from tester | |
Bosbtvfbkt | 0x0468 | STAT_Bosbtvfbkt_WERT | unsigned char | - | 1.000000 | 0.000000 | Bosbtvfbkt | Availability from tester | |
Zrbosrt | 0x0469 | STAT_Zrbosrt_WERT | unsigned char | - | 1.000000 | 0.000000 | Zrbosrt | Service meter reading from tester | |
Bosrlsmt | 0x046A | STAT_Bosrlsmt_WERT | unsigned int | - | 0.500000 | -16317.500000 | Bosrlsmt | Engine oil remaining distance from tester | |
Bosunt | 0x046B | STAT_Bosunt_WERT | unsigned char | - | 1.000000 | 0.000000 | Bosunt | Unit for Bosrlsmt | |
Bosrw2t | 0x046C | STAT_Bosrw2t_WERT | unsigned char | km | 1000.000000 | 0.000000 | Bosrw2t | Forecast interval distance from tester | |
Bosmzielt | 0x046D | STAT_Bosmzielt_WERT | unsigned char | - | 1.000000 | 0.000000 | Bosmzielt | Target date month from tester | |
Bosjzielt | 0x046E | STAT_Bosjzielt_WERT | unsigned char | - | 1.000000 | 0.000000 | Bosjzielt | Target date year from tester | |
Bosprog2t | 0x046F | STAT_Bosprog2t_WERT | unsigned char | - | 1.000000 | 0.000000 | Bosprog2t | Forecast interval time from tester | |
Id_bosrtak | 0x0470 | STAT_Id_bosrtak_WERT | unsigned char | - | 1.000000 | 0.000000 | Id_bosrtak | Acknowledge Reset performed | |
Oz_niv | 0x0471 | STAT_Oz_niv_WERT | unsigned char | mm | 0.294118 | 0.000000 | Oz_niv | Engine oil level Sensor raw value | |
DSM_DisblMode_mp | 0x047E | STAT_DSM_DisblMode_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | DSM_DisblMode_mp | Current shutdown conditions of the fault memory management (provided by DSM configuration) | |
DSM_stPostDrive | 0x047F | STAT_DSM_stPostDrive_WERT | unsigned char | - | 1.000000 | 0.000000 | DSM_stPostDrive | Status of the DSM overrun control | |
DSMRdy_Why_RdyComprCmpnt_mp | 0x0482 | STAT_DSMRdy_Why_RdyComprCmpnt_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | DSMRdy_Why_RdyComprCmpnt_mp | Cause (name of fault check)/Comprehensive component monitoring not ready | |
DSMRdy_Why_RdyEGR_mp | 0x0483 | STAT_DSMRdy_Why_RdyEGR_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | DSMRdy_Why_RdyEGR_mp | Cause (name of fault check)/EGR system monitoring not ready | |
DSMRdy_Why_RdyFlSys_mp | 0x0484 | STAT_DSMRdy_Why_RdyFlSys_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | DSMRdy_Why_RdyFlSys_mp | Cause (name of fault check)/Fuel system monitoring not ready | |
DSMRdy_Why_CyclCmplComprCmpnt_mp | 0x0485 | STAT_DSMRdy_Why_CyclCmplComprCmpnt_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | DSMRdy_Why_CyclCmplComprCmpnt_mp | Cause (name of fault check)/Comprehensive component monitoring not tested in current DC | |
DSMRdy_Why_CyclCmplEGR_mp | 0x0486 | STAT_DSMRdy_Why_CyclCmplEGR_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | DSMRdy_Why_CyclCmplEGR_mp | Cause (name of fault check)/EGR system monitoring not tested in current DC | |
DSMRdy_Why_CyclCmplFlSys_mp | 0x0487 | STAT_DSMRdy_Why_CyclCmplFlSys_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | DSMRdy_Why_CyclCmplFlSys_mp | Cause (name of fault check)/Fuel system monitoring not tested in current DC | |
DSMAUX_ctWUC | 0x0488 | STAT_DSMAUX_ctWUC_WERT | unsigned char | - | 1.000000 | 0.000000 | DSMAUX_ctWUC | Number of warm up cycles since fault memory was cleared | |
DFC_ctLDF_mp | 0x0489 | STAT_DFC_ctLDF_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | DFC_ctLDF_mp | Number of defective error checks, LDF (last debouced error flag) set | |
PFlt_stCdnDenom | 0x04A5 | STAT_PFlt_stCdnDenom_WERT | unsigned char | - | 1.000000 | 0.000000 | PFlt_stCdnDenom | DIUMPR denominator for particle filter regeneration | |
DFES_ctDef | 0x04A6 | STAT_DFES_ctDef_WERT | unsigned char | - | 1.000000 | 0.000000 | DFES_ctDef | Error counter (FLC) of all error memory entries | |
DFES_ctEntry | 0x04A7 | STAT_DFES_ctEntry_WERT | unsigned char | - | 1.000000 | 0.000000 | DFES_ctEntry | Number of occupied error memory entries | |
DFES_ctOBD | 0x04A8 | STAT_DFES_ctOBD_WERT | unsigned char | - | 1.000000 | 0.000000 | DFES_ctOBD | Number of fault memory entries visible in mode 3 | |
DFES_ctOBDPend | 0x04A9 | STAT_DFES_ctOBDPend_WERT | unsigned char | - | 1.000000 | 0.000000 | DFES_ctOBDPend | Number of fault memory entries visible in mode 7 (pending) | |
DIUMPR_ctGenDenom | 0x04AA | STAT_DIUMPR_ctGenDenom_WERT | unsigned int | - | 1.000000 | 0.000000 | DIUMPR_ctGenDenom | General denominator | |
DIUMPR_ctIgn | 0x04AB | STAT_DIUMPR_ctIgn_WERT | unsigned int | - | 1.000000 | 0.000000 | DIUMPR_ctIgn | Counter for number of start cycles | |
DFES_ctMIL | 0x04AC | STAT_DFES_ctMIL_WERT | unsigned char | - | 1.000000 | 0.000000 | DFES_ctMIL | Number of MIL triggering fault memory entries | |
InjVlv_volPiI1_mp | 0x04B0 | STAT_InjVlv_volPiI1_mp_WERT | unsigned int | mm^3/inj | 0.003052 | -100.000000 | InjVlv_volPiI1_mp | Injection volume of pre-injection 1 after quantity balancing | |
IDGH1 | 0x04B1 | STAT_ANSTEUERDAUER_HAUPTEINSPRITZUNG1_GESCHAETZT_WERT | unsigned int | us | 0.038148 | 0.000000 | InjVlv_tiMI1ET_mp | Control duration for main injection 1 | |
IDVE1 | 0x04B2 | STAT_ANSTEUERDAUER_VOREINSPRITZUNG1_WERT | unsigned int | us | 0.038148 | 0.000000 | InjVlv_tiPiI1ET_mp | Control duration for pre-injection 1 | |
InjVlv_volMI1_mp | 0x04B3 | STAT_InjVlv_volMI1_mp_WERT | unsigned int | mm^3/inj | 0.003052 | -100.000000 | InjVlv_volMI1_mp | Injection volume of main injection 1 after quantity calibration | |
InjVlv_stInjCoE | 0x04B7 | STAT_InjVlv_stInjCoE_WERT | unsigned char | - | 1.000000 | 0.000000 | InjVlv_stInjCoE | InjVlv_stInjCoE | |
InjVlv_stPsIcTra_0 | 0x04B8 | STAT_InjVlv_stPsIcTra_WERT | unsigned long | - | 1.000000 | 0.000000 | InjVlv_stPsIcTra_0 | InjVlv_stPsIcTra 0 | |
IWHE1 | 0x04CE | STAT_BEZUGSWINKEL_BEGINN_HAUPTEINSPRITZUNG1_WERT | unsigned int | degCrs | 0.003052 | -100.000000 | InjCrv_phiMI1Des | Setpoint of the reference angle for the start of main injection 1 | |
ITVE1 | 0x04CF | STAT_BEZUGSZEITKOMPONENTE_BEGINN_VOREINSPRITZUNG1_WERT | unsigned int | us | 0.400000 | 0.000000 | InjCrv_tiPiI1Des | Setpoint for start of pilot injection 1 | |
IMVE1 | 0x04D0 | STAT_MENGE_VOREINSPRITZUNG1_WERT | unsigned int | mg/Hub | 0.003052 | -100.000000 | InjCrv_qPiI1Des_mp | Injection quantity setpoint for pre-injection 1 | |
IMVE2 | 0x04D1 | STAT_MENGE_VOREINSPRITZUNG2_WERT | unsigned int | mg/Hub | 0.003052 | -100.000000 | InjCrv_qPiI2Des_mp | Injection quantity set point for pre-injection 2 | |
IWVE1 | 0x04D2 | STAT_WINKELKOMPONENTE_BEGINN_VOREINSPRITZUNG1_WERT | unsigned int | degCrS | 0.003052 | -100.000000 | InjCrv_phiPiI1Des | Set point of the reference angle for the start of pilot injection 1 | |
IWVE2 | 0x04D3 | STAT_WINKELKOMPONENTE_BEGINN_VOREINSPRITZUNG2_WERT | unsigned int | degCrS | 0.003052 | -100.000000 | InjCrv_phiPiI2Des | Reference angle setpoint for the start of pilot injection 2 | |
IWNE2 | 0x04D4 | STAT_BEZUGSWINKEL_BEGINN_NACHEINSPRITZUNG2_WERT | unsigned int | degCrS | 0.003052 | -100.000000 | InjCrv_phiPoI2Des | Reference angle setpoint for start of post-injection 2 | |
IWNE1 | 0x04D5 | STAT_BEZUGSWINKEL_BEGINN_NACHEINSPRITZUNG1_WERT | unsigned int | degCrS | 0.003052 | -100.000000 | InjCrv_phiPoI1Des | Reference angle setpoint for start of post-injection 1 | |
IMEIA | 0x0500 | STAT_EINSPRITZMENGE_AKTUELL_WERT | unsigned int | mg/hub | 0.003052 | -100.000000 | InjCtl_qCurr | Injection quantity - current value | |
SMEIO | 0x0501 | STAT_EINSPRITZMENGE_SOLL_OHNE_MENGENAUSGLEICH_WERT | unsigned int | mg/hub | 0.003052 | -100.000000 | InjCtl_qSetUnBal | Injection quantity - set value without quantity compensation control | |
SMEIN | 0x0502 | STAT_EINSPRITZMENGE_SOLL_WERT | unsigned int | mg/hub | 0.003052 | -100.000000 | InjCtl_qRaw | Injection quantity - raw value | |
InjCtl_qDriftComp | 0x0504 | STAT_InjCtl_qDriftComp_WERT | unsigned int | mg/cyc | 0.000305 | -10.000000 | InjCtl_qDriftComp | Calculated drift quantity from map | |
InjCtl_qDriftMax1_mp | 0x0505 | STAT_InjCtl_qDriftMax1_mp_WERT | unsigned int | mg/cyc | 0.000305 | -10.000000 | InjCtl_qDriftMax1_mp | Maximum quantity drift compensation limit (stored in EEPROM) | |
InjCtl_qDriftMin1_mp | 0x0506 | STAT_InjCtl_qDriftMin1_mp_WERT | unsigned int | mg/cyc | 0.000305 | -10.000000 | InjCtl_qDriftMin1_mp | Minimum quantity drift compensation limit (stored in EEPROM) | |
Tprot_Std_stDSPrfCls | 0x0508 | STAT_Tprot_Std_stDSPrfCls_WERT | unsigned char | - | 1.000000 | 0.000000 | Tprot_Std_stDSPrfCls | Applied value of the performance class | |
CodVar_stPrfCls | 0x0509 | STAT_CodVar_stPrfCls_WERT | unsigned char | - | 1.000000 | 0.000000 | CodVar_stPrfCls | Coded value of the power class | |
CodVar_stBlk0_mp | 0x050A | STAT_CodVar_stBlk0_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | CodVar_stBlk0_mp | Status of self-detection block 0 | |
CodVar_stBlk1_mp | 0x050B | STAT_CodVar_stBlk1_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | CodVar_stBlk1_mp | Status of self-detection block 1 | |
CodVar_stBlk2_mp | 0x050C | STAT_CodVar_stBlk2_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | CodVar_stBlk2_mp | Status of self-detection block 2 | |
CodVar_stBlk3_mp | 0x050D | STAT_CodVar_stBlk3_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | CodVar_stBlk3_mp | Status of self-detection block 3 | |
CoEng_st | 0x0514 | STAT_CoEng_st_WERT | unsigned char | - | 1.000000 | 0.000000 | CoEng_st | Current motor status | |
ISABU | 0x0515 | STAT_TYP_WIRKSAME_ABSCHALTURSACHE_WERT | unsigned long | - | 1.000000 | 0.000000 | CoEng_stShutOffPath | Active shutdown paths resulting from active reversible, irreversible and overrun shutdown paths. | |
CoEng_stState_mp | 0x0518 | STAT_CoEng_stState_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | CoEng_stState_mp | current motor status | |
CoEng_tiState | 0x051A | STAT_CoEng_tiState_WERT | unsigned int | s | 0.100000 | 0.000000 | CoEng_tiState | Current duration in current system state | |
CoEng_tiStart | 0x051B | STAT_CoEng_tiStart_WERT | unsigned long | ms | 10.000000 | 0.000000 | CoEng_tiStart | Time since reaching engine state COENG_READY & COENG_CRANKING (KL15 on to start ejection) | |
Exh_tAdapTOxiCatUs | 0x051E | STAT_Exh_tAdapTOxiCatUs_WERT | unsigned int | degC | 0.031281 | -50.000000 | Exh_tAdapTOxiCatUs | Exhaust gas temperature before catalytic converter | |
Exh_stPPDsBasCondNoMask_mp | 0x051F | STAT_Exh_stPPDsBasCondNoMask_mp_WERT | unsigned int | - | 0.003891 | 0.000000 | Exh_stPPDsBasCondNoMask_mp | Release condition of the particle sensor state machine | |
Exh_stPPDsStMa | 0x0520 | STAT_Exh_stPPDsStMa_WERT | unsigned char | - | 1.000000 | 0.000000 | Exh_stPPDsStMa | Status of the particle sensor state machine | |
Exh_stPPDsStCodRaw | 0x0521 | STAT_Exh_stPPDsStCodRaw_WERT | unsigned char | - | 1.000000 | 0.000000 | Exh_stPPDsStCodRaw | Status bit bar of the particle sensor | |
Exh_stPPDsErrCodRaw | 0x0522 | STAT_Exh_stPPDsErrCodRaw_WERT | unsigned char | - | 1.000000 | 0.000000 | Exh_stPPDsErrCodRaw | Error bit bar of the particle sensor | |
Exh_tPPDsTempMea | 0x0523 | STAT_Exh_tPPDsTempMea_WERT | unsigned int | degC | 0.016022 | -50.000000 | Exh_tPPDsTempMea | Maeander temperature of the particle sensor | |
Exh_facPPDsSnsrSnvtyRaw | 0x0524 | STAT_Exh_facPPDsSnsrSnvtyRaw_WERT | unsigned int | - | 0.000046 | 0.000000 | Exh_facPPDsSnsrSnvtyRaw | Sensitivity factor of the particle sensor | |
Exh_iPPDsIDEFild | 0x0525 | STAT_Exh_iPPDsIDEFild_WERT | unsigned int | uA | 0.001526 | 0.000000 | Exh_iPPDsIDEFild | Measured and filtered sensor current | |
Exh_uPPDsBattSnsrRaw | 0x0526 | STAT_Exh_uPPDsBattSnsrRaw_WERT | unsigned char | V | 0.078431 | 0.000000 | Exh_uPPDsBattSnsrRaw | Supply voltage at the sensor control unit | |
Exh_stPPDsProtnTubeIntglRlsCond_mp | 0x0527 | STAT_Exh_stPPDsProtnTubeIntglRlsCond_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | Exh_stPPDsProtnTubeIntglRlsCond_mp | Release conditions for protection tube diagnosis | |
Exh_stPPDsColdCdnNoMask_mp | 0x0528 | STAT_Exh_stPPDsColdCdnNoMask_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | Exh_stPPDsColdCdnNoMask_mp | Status Maeander Start temperature at cold start | |
Exh_tPPDsExh_mp | 0x0529 | STAT_Exh_tPPDsExh_mp_WERT | unsigned int | degC | 0.011444 | -50.000000 | Exh_tPPDsExh_mp | Exhaust gas temperature at sensor installation location | |
Exh_nrPPDsEMPSSwId | 0x052A | STAT_Exh_nrPPDsEMPSSwId_WERT | unsigned int | - | 1.000000 | 0.000000 | Exh_nrPPDsEMPSSwId | Software version of the particle sensor | |
Exh_stPPDsStrtCdnNoMask_mp | 0x052B | STAT_Exh_stPPDsStrtCdnNoMask_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | Exh_stPPDsStrtCdnNoMask_mp | Status TPE detection Maeander temperature start value | |
Exh_stPPDsDynCdnNoMask_mp | 0x052C | STAT_Exh_stPPDsDynCdnNoMask_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | Exh_stPPDsDynCdnNoMask_mp | Status Maeander start temperature during driving | |
RUTKU | 0x0546 | STAT_KUEHLMITTELTEMPERATUR_SPANNUNG_ROH_WERT | unsigned int | mV | 0.076295 | 0.000000 | CEngDsT_uRaw | Coolant temperature - raw voltage value of the sensor | |
ITKUM | 0x0547 | STAT_KUEHLMITTELTEMPERATUR_WERT | unsigned int | degC | 0.010000 | -100.000000 | CEngDsT_t | Coolant temperature | |
CEngDsT_tiDynTst_mp | 0x0548 | STAT_CEngDsT_tiDynTst_mp_WERT | unsigned long | s | 0.010000 | 0.000000 | CEngDsT_tiDynTst_mp | Dynamic plausibility check time for the coolant temperature | |
CEngDsT_tStrt_mp | 0x0549 | STAT_CEngDsT_tStrt_mp_WERT | unsigned int | degC | 0.100000 | -273.140000 | CEngDsT_tStrt_mp | Frozen coolant temperature at the start of the plausibility function | |
TEGRClr2Ds_t | 0x055A | STAT_TEGRClr2Ds_t_WERT | unsigned int | degC | 0.016022 | -50.000000 | TEGRClr2Ds_t | Temperature after LP-AGR cooler | |
TEGRClr2Ds_tSens | 0x055B | STAT_TEGRClr2Ds_tSens_WERT | unsigned int | degC | 0.016022 | -50.000000 | TEGRClr2Ds_tSens | Sensor temperature after LP-AGR cooler | |
TEGRClr2Ds_uRaw | 0x055C | STAT_TEGRClr2Ds_uRaw_WERT | unsigned int | mV | 0.076295 | 0.000000 | TEGRClr2Ds_uRaw | Sensor raw voltage - temperature after LP-AGR cooler | |
CtT_tClntEngMod | 0x0564 | STAT_CtT_tClntEngMod_WERT | unsigned int | degC | 0.100000 | -273.140000 | CtT_tClntEngMod | Modelled coolant temperature | |
EGRCPmp_r | 0x0569 | STAT_EGRCPmp_r_WERT | unsigned int | % | 0.001526 | 0.000000 | EGRCPmp_r | Duty cycle control of additional water pump NT-AGR | |
ClntVlv2_r | 0x056A | STAT_ClntVlv2_r_WERT | unsigned int | % | 0.001526 | 0.000000 | ClntVlv2_r | Duty cycle control of change-over valve NT-AGR | |
CTEGRClrUs_t | 0x056E | STAT_CTEGRClrUs_t_WERT | unsigned int | degC | 0.003052 | -50.000000 | CTEGRClrUs_t | Coolant temperature upstream of NT-AGR cooler | |
CTEGRClrUs_tSens | 0x056F | STAT_CTEGRClrUs_tSens_WERT | unsigned int | degC | 0.003052 | -50.000000 | CTEGRClrUs_tSens | Coolant sensor temperature upstream of NT-AGR cooler | |
CTEGRClrUs_uRaw | 0x0570 | STAT_CTEGRClrUs_uRaw_WERT | unsigned int | mV | 0.076295 | 0.000000 | CTEGRClrUs_uRaw | Raw sensor voltage - cooling medium temperature upstream of NT-AGR cooler | |
IAMMM | 0x0578 | STAT_VERHAELTNIS_AKTUELLES_MOMENT_MAXIMALMOMENT_WERT | unsigned int | % | 0.001526 | 0.000000 | CoETS_rTrq | Ratio of actual torque to maximum torque | |
SMIBA | 0x0579 | STAT_MOTORMOMENT_SOLL_NACH_BEGRENZUNG_VOR_ARD_WERT | unsigned int | Nm | 0.100000 | 0.000000 | CoETS_trqInrLim | Limiting torque (as internal motor torque) | |
CoETS_stCurrLimActive | 0x057A | STAT_CoETS_stCurrLimActive_WERT | unsigned int | - | 1.000000 | 0.000000 | CoETS_stCurrLimActive | Status word to mark the effective lowest limiting torques | |
IMBEG | 0x057B | STAT_MOTORMOMENT_BEGRENZUNG_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | CoETS_trqInrSetSlow | Setpoint-inner torque | |
HEGN_rAvrgSlfDiagB1S1 | 0x0582 | STAT_HEGN_rAvrgSlfDiagB1S1_WERT | unsigned int | % | 0.012207 | -400.000000 | HEGN_rAvrgSlfDiagB1S1 | Averaged value of the last three stored self-diagnostic values from the NOx sensor before SCR | |
HEGN_rMaxResSlfDiagB1S1 | 0x0583 | STAT_HEGN_rMaxResSlfDiagB1S1_WERT | unsigned int | % | 0.012207 | -400.000000 | HEGN_rMaxResSlfDiagB1S1 | Maximum self-diagnostic value of all run diangnosis cycles of the NOx sensor before SCR | |
HEGN_rMinResSlfDiagB1S1 | 0x0584 | STAT_HEGN_rMinResSlfDiagB1S1_WERT | unsigned int | % | 0.012207 | -400.000000 | HEGN_rMinResSlfDiagB1S1 | Minimum self-diagnosis value of all run diangnosis cycles of the NOx sensor before SCR | |
HEGN_rResFldSlfDiagB1S1_0 | 0x0585 | STAT_HEGN_rResFldSlfDiagB1S1_0_WERT | unsigned int | % | 0.012207 | -400.000000 | HEGN_rResFldSlfDiagB1S1_0 | Stored self-diagnosis value from NOx sensor before SCR - Index 0 | |
HEGN_rResFldSlfDiagB1S1_1 | 0x0586 | STAT_HEGN_rResFldSlfDiagB1S1_1_WERT | unsigned int | % | 0.012207 | -400.000000 | HEGN_rResFldSlfDiagB1S1_1 | Stored self-diagnosis value from NOx sensor before SCR - Index 1 | |
HEGN_rResFldSlfDiagB1S1_2 | 0x0587 | STAT_HEGN_rResFldSlfDiagB1S1_2_WERT | unsigned int | % | 0.012207 | -400.000000 | HEGN_rResFldSlfDiagB1S1_2 | Stored self-diagnostic value from NOx sensor before SCR - Index 2 | |
HEGN_rAvrgSlfDiagB1S2 | 0x0589 | STAT_HEGN_rAvrgSlfDiagB1S2_WERT | unsigned int | % | 0.012207 | -400.000000 | HEGN_rAvrgSlfDiagB1S2 | Averaged value of the last three stored self-diagnostic values from the NOx sensor after SCR | |
HEGN_rMaxResSlfDiagB1S2 | 0x058A | STAT_HEGN_rMaxResSlfDiagB1S2_WERT | unsigned int | % | 0.012207 | -400.000000 | HEGN_rMaxResSlfDiagB1S2 | Maximum self-diagnostic value of all run diangnosis cycles of the NOx sensor after SCR | |
HEGN_rMinResSlfDiagB1S2 | 0x058B | STAT_HEGN_rMinResSlfDiagB1S2_WERT | unsigned int | % | 0.012207 | -400.000000 | HEGN_rMinResSlfDiagB1S2 | Minimum self-diagnosis value of all run diangnosis cycles of the NOx sensor after SCR | |
HEGN_rResFldSlfDiagB1S2_0 | 0x058C | STAT_HEGN_rResFldSlfDiagB1S2_0_WERT | unsigned int | % | 0.012207 | -400.000000 | HEGN_rResFldSlfDiagB1S2_0 | First stored self-diagnosis value from NOx sensor after SCR 0 | |
HEGN_rResFldSlfDiagB1S2_1 | 0x058D | STAT_HEGN_rResFldSlfDiagB1S2_1_WERT | unsigned int | % | 0.012207 | -400.000000 | HEGN_rResFldSlfDiagB1S2_1 | First stored self-diagnosis value from NOx sensor after SCR 1 | |
HEGN_rResFldSlfDiagB1S2_2 | 0x058E | STAT_HEGN_rResFldSlfDiagB1S2_2_WERT | unsigned int | % | 0.012207 | -400.000000 | HEGN_rResFldSlfDiagB1S2_2 | First stored self-diagnosis value from NOx sensor after SCR 2 | |
CoEOM_stOpModeAct | 0x05AA | STAT_CoEOM_stOpModeAct_WERT | unsigned long | hex | 1.000000 | 0.000000 | CoEOM_stOpModeAct | Operating mode - status | |
Bszsi | 0x05C8 | STAT_Bszsi_WERT | unsigned long | - | 1.000000 | 0.000000 | Bszsi | Operating hours counter | |
CoPT_trqDes | 0x05D2 | STAT_CoPT_trqDes_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | CoPT_trqDes | Total torque application to torque controller (clutch torque) | |
EngPrt_trqLim | 0x05D3 | STAT_EngPrt_trqLim_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | EngPrt_trqLim | Limiting torque to protect against excessive torque (as internal engine torque) | |
EngReq_trqLim | 0x05D4 | STAT_EngReq_trqLim_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | EngReq_trqLim | Resulting limiting torque from motor specifications | |
EngDem_trqLimErr | 0x05D5 | STAT_EngDem_trqLimErr_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | EngDem_trqLimErr | Limiting torque in the event of a fault | |
Com_lSum_8km | 0x05DC | STAT_Com_lSum_WERT | unsigned int | km | 8.000000 | 0.000000 | Com_lSum_8km | Mileage (resolution 8 km) | |
ISKME | 0x05DD | STAT_KILOMETERSTAND_WERT | unsigned long | km | 1.000000 | 0.000000 | Com_lSum | Mileage | |
Com_nPsp | 0x05DE | STAT_Com_nPsp_WERT | unsigned int | rpm | 1.000000 | 0.000000 | Com_nPsp | Speed of the feed pump | |
Com_rPspSetPoint | 0x05DF | STAT_Com_rPspSetPoint_WERT | unsigned int | % | 0.012207 | 0.000000 | Com_rPspSetPoint | Output duty cycle - feed pump | |
Com_ctrSec | 0x05E0 | STAT_Com_ctrSec_WERT | unsigned long | s | 1.000000 | 0.000000 | Com_ctrSec | Second counter relative | |
Com_rawByte6SensNOxGnd | 0x05E1 | STAT_Com_rawByte6SensNOxGnd_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_rawByte6SensNOxGnd | Com_rawByte6SensNOxGnd | |
Com_rawByte6SensNOxUbatt | 0x05E2 | STAT_Com_rawByte6SensNOxUbatt_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_rawByte6SensNOxUbatt | Com_rawByte6SensNOxUbatt | |
Com_rawByte7SensNOxGnd | 0x05E3 | STAT_Com_rawByte7SensNOxGnd_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_rawByte7SensNOxGnd | Com_rawByte7SensNOxGnd | |
Com_rawByte7SensNOxUbatt | 0x05E4 | STAT_Com_rawByte7SensNOxUbatt_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_rawByte7SensNOxUbatt | Com_rawByte7SensNOxUbatt | |
Com_rLamLinRecCat2Ds | 0x05E5 | STAT_Com_rLamLinRecCat2Ds_WERT | unsigned int | - | 0.000100 | -3.267800 | Com_rLamLinRecCat2Ds | Oxygen linear NOx sensor 2 (after SCR cat) | |
Com_rLamLinRecDs | 0x05E6 | STAT_Com_rLamLinRecDs_WERT | unsigned int | - | 0.000100 | -3.267800 | Com_rLamLinRecDs | Oxygen linear NOx sensor 1 (before SCR catalytic converter) | |
Com_rNOxCat2Ds | 0x05E7 | STAT_Com_rNOxCat2Ds_WERT | unsigned int | ppm | 0.025940 | -50.000000 | Com_rNOxCat2Ds | determined NOx concentration NOx sensor 2 (after SCR catalytic converter) | |
Com_rNOxDs | 0x05E8 | STAT_Com_rNOxDs_WERT | unsigned int | ppm | 0.025940 | -50.000000 | Com_rNOxDs | determined NOx concentration NOx sensor 1 (before SCR catalytic converter) | |
Com_uLamBinCat2Ds | 0x05E9 | STAT_Com_uLamBinCat2Ds_WERT | unsigned int | mV | 0.033570 | -200.000000 | Com_uLamBinCat2Ds | Oxygen binary NOx sensor 2 (after SCR catalytic converter) | |
Com_uLamBinDs | 0x05EA | STAT_Com_uLamBinDs_WERT | unsigned int | mV | 0.033570 | -200.000000 | Com_uLamBinDs | Oxygen binary NOx sensor 1 (before SCR cat) | |
Com_ctrDay | 0x05EB | STAT_Com_ctrDay_WERT | unsigned int | - | 1.000000 | 0.000000 | Com_ctrDay | Day counter absolute | |
Com_dDay | 0x05EC | STAT_Com_dDay_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_dDay | Display weekday | |
Com_dMonth | 0x05ED | STAT_Com_dMonth_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_dMonth | Display month | |
Com_dYear | 0x05EE | STAT_Com_dYear_WERT | unsigned int | - | 1.000000 | 0.000000 | Com_dYear | Display year | |
Com_stMskLINSigAct | 0x05EF | STAT_Com_stMskLINSigAct_WERT | unsigned long | - | 1.000000 | 0.000000 | Com_stMskLINSigAct | Status word signal error LIN | |
Com_stMskCANSigAct | 0x05F0 | STAT_Com_stMskCANSigAct_WERT | unsigned long | - | 1.000000 | 0.000000 | Com_stMskCANSigAct | Status word signal error CAN | |
Com_stDoorSecuCoDr | 0x05F1 | STAT_Com_stDoorSecuCoDr_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_stDoorSecuCoDr | Door contact status - front passenger | |
Com_stDoorSecuCoDrBck | 0x05F2 | STAT_Com_stDoorSecuCoDrBck_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_stDoorSecuCoDrBck | Door contact status - rear passenger | |
Com_stDoorSecuDr | 0x05F3 | STAT_Com_stDoorSecuDr_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_stDoorSecuDr | Door contact status - driver front | |
Com_stDoorSecuDrBck | 0x05F4 | STAT_Com_stDoorSecuDrBck_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_stDoorSecuDrBck | Door contact status - rear driver | |
Isgusm_uist | 0x05F5 | STAT_Isgusm_uist_WERT | unsigned int | V | 0.010000 | 0.000000 | Isgusm_uist | Terminal voltage E-machine | |
Com_nTSC | 0x0604 | STAT_Com_nTSC_WERT | unsigned int | rpm | 0.500000 | 0.000000 | Com_nTSC | Transmission turbine speed | |
Gbx_nTrbn | 0x0605 | STAT_Gbx_nTrbn_WERT | unsigned int | rpm | 0.500000 | 0.000000 | Gbx_nTrbn | Turbine speed layer | |
Com_stDSC | 0x0606 | STAT_Com_stDSC_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_stDSC | DSC status | |
Com_tGbxOil | 0x0607 | STAT_Com_tGbxOil_WERT | unsigned char | degC | 1.000000 | -40.000000 | Com_tGbxOil | Transmission oil temperature (1 byte) | |
Tget | 0x0608 | STAT_Tget_WERT | unsigned char | degC | 1.000000 | -40.000000 | Tget | Transmission oil temperature layer (1 byte) | |
Twandler_sim | 0x0609 | STAT_Twandler_sim_WERT | unsigned char | degC | 1.529412 | -40.000000 | Twandler_sim | Modelled temperature at gearbox output layer (1 byte) | |
Com_stTrailer | 0x060A | STAT_Com_stTrailer_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_stTrailer | Trailer status | |
DIUMPR_stEvapDen | 0x060B | STAT_DIUMPR_stEvapDen_WERT | unsigned char | - | 1.000000 | 0.000000 | DIUMPR_stEvapDen | EVAP Counter | |
DSMEnv_lSumEnv | 0x060C | STAT_DSMEnv_lSumEnv_WERT | unsigned long | km | 1.000000 | 0.000000 | DSMEnv_lSumEnv | DSMEnv_lSumEnv | |
DSMEnv_ctrSecEnv | 0x060D | STAT_DSMEnv_ctrSecEnv_WERT | unsigned long | - | 1.000000 | 0.000000 | DSMEnv_ctrSecEnv | DSMEnv_ctrSecEnv | |
DSMEnv_ctEntryEnv | 0x060E | STAT_DSMEnv_ctEntryEnv_WERT | unsigned char | - | 1.000000 | 0.000000 | DSMEnv_ctEntryEnv | DSMEnv_ctEntryEnv | |
DSMEnv_stECUEnv | 0x060F | STAT_DSMEnv_stECUEnv_WERT | unsigned char | - | 1.000000 | 0.000000 | DSMEnv_stECUEnv | DSMEnv_stECUEnv | |
DSMEnv_stEntryStateEnv | 0x0610 | STAT_DSMEnv_stEntryStateEnv_WERT | unsigned char | - | 1.000000 | 0.000000 | DSMEnv_stEntryStateEnv | DSMEnv_stEntryStateEnv | |
Nturb_calc | 0x0611 | STAT_Nturb_calc_WERT | unsigned int | rpm | 0.100000 | 0.000000 | Nturb_calc | Modelled turbine speed (GOTM automatic transmission) | |
St_on_nv1 | 0x0613 | STAT_St_on_nv1_WERT | unsigned char | - | 1.000000 | 0.000000 | St_on_nv1 | Status indicator ON (B_onausg_25recognised, B_onsm_minerk_pwferk) | |
On_ausg_kmalt | 0x0614 | STAT_On_ausg_kmalt_WERT | unsigned int | km | 10.000000 | 0.000000 | On_ausg_kmalt | Odometer reading at minimum oil level detection | |
On_oelniveau | 0x0615 | STAT_On_oelniveau_WERT | unsigned char | cl | 1.000000 | 0.000000 | On_oelniveau | ABK interface oil level | |
SysVar_swtTgtMrkt | 0x0616 | STAT_SysVar_swtTgtMrkt_WERT | unsigned char | - | 1.000000 | 0.000000 | SysVar_swtTgtMrkt | Switch selection country variant | |
Conv_nTrbn | 0x0618 | STAT_Conv_nTrbn_WERT | unsigned int | rpm | 0.500000 | 0.000000 | Conv_nTrbn | Turbine speed | |
ISRDR | 0x0640 | STAT_STATUS_RAILDRUCKREGLER_WERT | unsigned char | - | 1.000000 | 0.000000 | Rail_stCtlLoop | Status - Rail pressure control mode | |
SPRDR | 0x0641 | STAT_RAILDRUCK_SOLL_WERT | unsigned int | bar | 0.045777 | 0.000000 | Rail_pSetPoint | Rail pressure setpoint | |
Rail_dvolPreCtl | 0x0642 | STAT_Rail_dvolPreCtl_WERT | unsigned int | mm3/s | 10.000000 | 0.000000 | Rail_dvolPreCtl | Flow control valve pilot value for pressure control | |
Rail_pDvt | 0x0644 | STAT_Rail_pDvt_WERT | unsigned int | bar | 0.100000 | 0.000000 | Rail_pDvt | Rail pressure controller control deviation | |
Rail_stCPC | 0x0645 | STAT_Rail_stCPC_WERT | unsigned char | - | 1.000000 | 0.000000 | Rail_stCPC | Rail pressure control status of the state machine | |
IPRDR | 0x0672 | STAT_RAILDRUCK_WERT | unsigned int | bar | 0.045777 | 0.000000 | RailP_pFlt | Maximum rail pressure of the last 10ms | |
IURDR | 0x0673 | STAT_RAILDRUCK_SPANNUNG_ROH_WERT | unsigned int | mV | 0.076295 | 0.000000 | RailP_uRaw | Rail pressure - raw voltage value from sensor | |
RailP_pCurr_mp | 0x0674 | STAT_RailP_pCurr_mp_WERT | unsigned int | bar | 0.045777 | 0.000000 | RailP_pCurr_mp | Rail pressure - actual value | |
RailP_pLin | 0x0675 | STAT_RailP_pLin_WERT | unsigned int | bar | 0.100000 | 0.000000 | RailP_pLin | linearised value of fuel pressure sensor | |
RailP_stGrad | 0x0677 | STAT_RailP_stGrad_WERT | unsigned char | - | 1.000000 | 0.000000 | RailP_stGrad | Status of the gradient test | |
RailP_ctGradExcd_mp | 0x0678 | STAT_RailP_ctGradExcd_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | RailP_ctGradExcd_mp | Number of detected pressure jumps | |
RailP_pOfsTstAvg | 0x0679 | STAT_RailP_pOfsTstAvg_WERT | unsigned int | bar | 0.100000 | -3273.500000 | RailP_pOfsTstAvg | Learned correction pressure from rail pressure offset test | |
Strt_stPs | 0x069A | STAT_Strt_stPs_WERT | unsigned char | - | 1.000000 | 0.000000 | Strt_stPs | Output of the starter to the output stage | |
St_dfh0 | 0x06A4 | STAT_St_dfh0_WERT | unsigned char | - | 1.000000 | 0.000000 | St_dfh0 | Status word - diesel filter heating | |
St_msaav | 0x06A6 | STAT_St_msaav_WERT | unsigned char | - | 1.000000 | 0.000000 | St_msaav | Status word - AV | |
St_msaanz | 0x06AD | STAT_St_msaanz_WERT | unsigned int | - | 1.000000 | 0.000000 | St_msaanz | Status word - MSA display | |
St_ngang | 0x06AE | STAT_St_ngang_WERT | unsigned char | - | 1.000000 | 0.000000 | St_ngang | Status zero gear detection | |
St_oznivdl1 | 0x06B0 | STAT_St_oznivdl1_WERT | unsigned char | - | 1.000000 | 0.000000 | St_oznivdl1 | Status word for oil level check | |
Msa_swdw | 0x06B3 | STAT_Msa_swdw_WERT | unsigned long | - | 1.000000 | 0.000000 | Msa_swdw | Status MSA deactivator (MSA2) | |
Msa_sweaw | 0x06B4 | STAT_Msa_sweaw_WERT | unsigned long | - | 1.000000 | 0.000000 | Msa_sweaw | Status MSA switch-on prompter (MSA2) | |
Msa_swevw | 0x06B5 | STAT_Msa_swevw_WERT | unsigned long | - | 1.000000 | 0.000000 | Msa_swevw | Status MSA switch-on inhibitor (MSA2) | |
Msa_swfavw | 0x06B6 | STAT_Msa_swfavw_WERT | unsigned long | - | 1.000000 | 0.000000 | Msa_swfavw | Status MSA driver switch-off preventer (MSA2) | |
Msa_swsavw | 0x06B7 | STAT_Msa_swsavw_WERT | unsigned long | - | 1.000000 | 0.000000 | Msa_swsavw | Status MSA System Shutdown Preventer (MSA2) | |
St_msae | 0x06B8 | STAT_St_msae_WERT | unsigned int | - | 1.000000 | 0.000000 | St_msae | Statusword msae (MSA2) | |
St_msasiko | 0x06B9 | STAT_St_msasiko_WERT | unsigned char | - | 1.000000 | 0.000000 | St_msasiko | Status byte MSA security concept (MSA2) | |
St_msacc | 0x06BB | STAT_St_msacc_WERT | unsigned char | - | 1.000000 | 0.000000 | St_msacc | Status byte CC messages for MSA (MSA2) | |
St_bgkuppl | 0x06BC | STAT_St_bgkuppl_WERT | unsigned char | - | 1.000000 | 0.000000 | St_bgkuppl | Status byte bgkuppl (MSA2) | |
Tvngang | 0x06BD | STAT_Tvngang_WERT | unsigned char | % | 0.392157 | 0.000000 | Tvngang | Duty cycle zero speed sensor (1 byte) | |
Tvneutral | 0x06BE | STAT_Tvneutral_WERT | unsigned int | % | 0.001526 | 0.000000 | Tvneutral | Zero speed position - layer | |
Tvneutrin | 0x06BF | STAT_Tvneutrin_WERT | unsigned int | % | 0.001526 | 0.000000 | Tvneutrin | Zero speed value from tester (layer) | |
Tumg | 0x06C0 | STAT_Tumg_WERT | unsigned int | degC | 0.004578 | -100.000000 | Tumg | Ambient temperature - layer | |
SmkLim_qLimSmk | 0x06C2 | STAT_SmkLim_qLimSmk_WERT | unsigned int | mg/Hub | 0.010000 | 0.000000 | SmkLim_qLimSmk | Limit quantity for smoke limitation | |
PthSet_trqInrSet | 0x06CD | STAT_PthSet_trqInrSet_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | PthSet_trqInrSet | Inner moment for the set path after monitoring limitation | |
ILMKG | 0x0708 | STAT_LUFTMASSE_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AFS_dm | Total HFM air mass flow | |
ILMMG | 0x0709 | STAT_LUFTMASSE_PRO_HUB_WERT | unsigned int | mg/hub | 0.024414 | 0.000000 | AFS_mAirPerCyl | Air mass per cylinder | |
AFS_rNorm_mp | 0x070A | STAT_AFS_rNorm_mp_WERT | unsigned int | - | 0.000122 | 0.000000 | AFS_rNorm_mp | Normalised airflow ratio | |
AFS_dmSensCorr_mp | 0x070B | STAT_AFS_dmSensCorr_mp_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AFS_dmSensCorr_mp | corrected airflow signal | |
AFS_facAdjVal_0 | 0x070C | STAT_AFS_facAdjVal_0_WERT | unsigned int | - | 0.000122 | 0.000000 | AFS_facAdjVal_0 | Correction factor of drift compensation (0=idle, 1=load) 0 | |
AFS_facAdjVal_1 | 0x070D | STAT_AFS_facAdjVal_1_WERT | unsigned int | - | 0.000122 | 0.000000 | AFS_facAdjVal_1 | Drift compensation correction factor (0=idle, 1=load) 1 | |
AFS_facAdjValUnLim_mp_0 | 0x0712 | STAT_AFS_facAdjValUnLim_mp_0_WERT | unsigned int | - | 0.000122 | 0.000000 | AFS_facAdjValUnLim_mp_0 | Air mass correction factor before step limitation (0=idle, 1=load) 0 | |
AFS_facAdjValUnLim_mp_1 | 0x0713 | STAT_AFS_facAdjValUnLim_mp_1_WERT | unsigned int | - | 0.000122 | 0.000000 | AFS_facAdjValUnLim_mp_1 | Air mass correction factor before step limitation (0=idle, 1=load) 1 | |
AFS_tiRaw | 0x0714 | STAT_AFS_tiRaw_WERT | unsigned long | us | 0.050000 | 0.000000 | AFS_tiRaw | Raw value of the air mass period | |
Air_uRawTAFS | 0x0715 | STAT_Air_uRawTAFS_WERT | unsigned int | mV | 0.200000 | 0.000000 | Air_uRawTAFS | Raw voltage value from the temperature sensor at HFM | |
Air_tiRawTAFS | 0x0716 | STAT_Air_tiRawTAFS_WERT | unsigned long | ms | 0.000050 | 0.000000 | Air_tiRawTAFS | Raw value of the period for the temperature signal from the HFM sensor | |
Air_facPerCorTAFS | 0x0717 | STAT_Air_facPerCorTAFS_WERT | unsigned int | - | 0.000122 | 0.000000 | Air_facPerCorTAFS | Time correction factor for the air mass signal | |
Air_tAFSCorr | 0x0718 | STAT_Air_tAFSCorr_WERT | unsigned int | degC | 0.100000 | -273.140000 | Air_tAFSCorr | Corrected intake air temperature | |
Air_tSensTCACDs | 0x0719 | STAT_Air_tSensTCACDs_WERT | unsigned int | degC | 0.003891 | -40.000000 | Air_tSensTCACDs | Temperature after charge air cooler | |
ITTAN | 0x076C | STAT_ANSAUGLUFTTEMPERATUR_TASTVERHAELTNIS_WERT | unsigned int | % | 0.010000 | 0.000000 | Air_rRawTAFS | Duty cycle - intake air temperature sensor | |
IPLAD | 0x076D | STAT_LADEDRUCK_WERT | unsigned int | hPa | 0.091554 | 0.000000 | Air_pIntkVUs | boost pressure - actual value | |
IULDF | 0x076E | STAT_LADEDRUCK_SPANNUNG_WERT | unsigned int | mV | 0.076295 | 0.000000 | Air_uRawPIntkVUs | Raw voltage value from ADC | |
ITLAL | 0x076F | STAT_LADELUFTTEMPERATUR_WERT | unsigned int | degC | 0.010000 | -100.000000 | Air_tCACDs | Temperature after the charge air cooler | |
Air_uRawTCACDs | 0x0770 | STAT_Air_uRawTCACDs_WERT | unsigned int | mV | 0.076295 | 0.000000 | Air_uRawTCACDs | Raw voltage value from ADC for CACDsT | |
Air_tSensTAFS | 0x0771 | STAT_Air_tSensTAFS_WERT | unsigned int | degC | 0.010000 | -50.000000 | Air_tSensTAFS | Air temperature HFM - from sensor curve | |
ITANS | 0x0772 | STAT_ANSAUGLUFTTEMPERATUR_WERT | unsigned int | degC | 0.100000 | -273.140000 | Air_tAFS | Air temperature at the HFM position | |
Air_uRawTEGRClrDs | 0x0775 | STAT_Air_uRawTEGRClrDs_WERT | unsigned int | mV | 0.076295 | 0.000000 | Air_uRawTEGRClrDs | Raw voltage value from the temperature sensor after the EGR cooler | |
Air_tSensTEGRClrDs | 0x0776 | STAT_Air_tSensTEGRClrDs_WERT | unsigned int | degC | 0.016022 | -50.000000 | Air_tSensTEGRClrDs | Recorded value of the exhaust gas temperature after the EGR cooler | |
Air_tEGRClrDs | 0x0777 | STAT_Air_tEGRClrDs_WERT | unsigned int | degC | 0.016022 | -50.000000 | Air_tEGRClrDs | EGR cooler down stream temperature | |
Air_uRawTEGRClrLPDs | 0x0778 | STAT_Air_uRawTEGRClrLPDs_WERT | unsigned int | mV | 0.076295 | 0.000000 | Air_uRawTEGRClrLPDs | Raw temperature signal after exhaust gas cooler | |
Air_tSensTEGRClrLPDs | 0x0779 | STAT_Air_tSensTEGRClrLPDs_WERT | unsigned int | degC | 0.016022 | -50.000000 | Air_tSensTEGRClrLPDs | Recorded temperature after exhaust gas cooler | |
Air_tEGRClrLPDs | 0x077A | STAT_Air_tEGRClrLPDs_WERT | unsigned int | degC | 0.016022 | -50.000000 | Air_tEGRClrLPDs | Temperature after low-pressure exhaust gas cooler | |
Air_pCACDs | 0x077B | STAT_Air_pCACDs_WERT | unsigned int | hPa | 1.000000 | 0.000000 | Air_pCACDs | PT1-filtered value of air pressure after charge air cooler | |
PCmprHiPUs_uRaw | 0x077D | STAT_PCmprHiPUs_uRaw_WERT | unsigned int | V | 0.000610 | -20.000000 | PCmprHiPUs_uRaw | Raw voltage value of pressure after charge air intercooler | |
PCmprHiPUs_pRaw | 0x077E | STAT_PCmprHiPUs_pRaw_WERT | unsigned int | hPa | 0.100000 | 0.000000 | PCmprHiPUs_pRaw | Raw value of pressure after charge air intercooler | |
PCmprHiPUs_p | 0x077F | STAT_PCmprHiPUs_p_WERT | unsigned int | hPa | 0.100000 | 0.000000 | PCmprHiPUs_p | Pressure before high-pressure compressor | |
PcmprHiPUs_pSnsr | 0x0780 | STAT_PcmprHiPUs_pSnsr_WERT | unsigned int | hPa | 0.100000 | 0.000000 | PcmprHiPUs_pSnsr | Detected pressure value before high-pressure compressor | |
AirCtl_stPrioRat | 0x0792 | STAT_AirCtl_stPrioRat_WERT | unsigned char | - | 1.000000 | 0.000000 | AirCtl_stPrioRat | Status indicating whether the total exhaust gas recirculation rate is the prioritised setpoint. | |
AirCtl_rDesVal | 0x0793 | STAT_AirCtl_rDesVal_WERT | unsigned int | - | 0.010000 | 0.000000 | AirCtl_rDesVal | EGR rate - set point | |
AirCtl_arEGRDes | 0x0794 | STAT_AirCtl_arEGRDes_WERT | unsigned int | cm^2 | 0.004000 | 0.000000 | AirCtl_arEGRDes | Exhaust gas recirculation valve setpoint area | |
AirCtl_arTVADes | 0x0795 | STAT_AirCtl_arTVADes_WERT | unsigned int | cm^2 | 0.004000 | 0.000000 | AirCtl_arTVADes | Target area of the throttle valve | |
AirCtl_dmEGRDes_r32 | 0x0796 | STAT_AirCtl_dmEGRDes_r32_WERT | motorola float | kg/h | 1.000000 | 0.000000 | AirCtl_dmEGRDes_r32 | Setpoint mass flow via exhaust gas recirculation valve | |
AirCtl_dmTVADes_r32 | 0x0797 | STAT_AirCtl_dmTVADes_r32_WERT | motorola float | kg/h | 1.000000 | 0.000000 | AirCtl_dmTVADes_r32 | Setpoint mass flow via throttle valve | |
AirCtl_stDesMax | 0x0798 | STAT_AirCtl_stDesMax_WERT | unsigned char | - | 1.000000 | 0.000000 | AirCtl_stDesMax | Status, whether one of the setpoints EGR rate or air mass is in max. limitation | |
AirCtl_rRatDesDyn_r32 | 0x0799 | STAT_AirCtl_rRatDesDyn_r32_WERT | motorola float | % | 1.000000 | 0.000000 | AirCtl_rRatDesDyn_r32 | dynamically adapted total set exhaust gas recirculation rate in the engine | |
AirCtl_dmAirDesDyn_r32 | 0x079A | STAT_AirCtl_dmAirDesDyn_r32_WERT | motorola float | kg/h | 1.000000 | 0.000000 | AirCtl_dmAirDesDyn_r32 | dynamically adapted target air mass flow into the engine | |
AirCtl_arEGREst | 0x079B | STAT_AirCtl_arEGREst_WERT | unsigned int | cm^2 | 0.004000 | 0.000000 | AirCtl_arEGREst | estimated actual area of the exhaust gas recirculation valve | |
AirCtl_arTVAEst | 0x079C | STAT_AirCtl_arTVAEst_WERT | unsigned int | cm^2 | 0.004000 | 0.000000 | AirCtl_arTVAEst | estimated actual flow of the throttle valve | |
AirCtl_pTrbnUs_r32 | 0x079D | STAT_AirCtl_pTrbnUs_r32_WERT | motorola float | hPa | 1.000000 | 0.000000 | AirCtl_pTrbnUs_r32 | estimated pressure upstream of the exhaust gas recirculation valve | |
SLMMG | 0x079E | STAT_LUFTMASSE_SOLL_WERT | unsigned int | mg/hub | 0.030518 | 0.000000 | AirCtl_mDesVal | Air mass - set point | |
AirCtl_stAirCtlBits | 0x07A0 | STAT_AirCtl_stAirCtlBits_WERT | unsigned long | - | 1.000000 | 0.000000 | AirCtl_stAirCtlBits | active shutdown of the air mass control | |
AirCtl_stMon | 0x07A1 | STAT_AirCtl_stMon_WERT | unsigned char | - | 1.000000 | 0.000000 | AirCtl_stMon | causal switch-off case of the air mass control | |
AirCtl_mGovDvt | 0x07A2 | STAT_AirCtl_mGovDvt_WERT | unsigned int | mg/hub | 0.100000 | 0.000000 | AirCtl_mGovDvt | Air mass - control deviation | |
AirCtl_rGovDvtNrm | 0x07A6 | STAT_AirCtl_rGovDvtNrm_WERT | unsigned int | % | 0.012207 | 0.000000 | AirCtl_rGovDvtNrm | Exhaust gas recirculation control - deviation | |
AirCtl_stMonBits | 0x07A7 | STAT_AirCtl_stMonBits_WERT | unsigned long | - | 1.000000 | 0.000000 | AirCtl_stMonBits | Selected, active shutdown cases of the air mass control | |
AirCtl_mDesBasEOM0 | 0x07A8 | STAT_AirCtl_mDesBasEOM0_WERT | unsigned int | mg/hub | 0.100000 | 0.000000 | AirCtl_mDesBasEOM0 | Air mass - base value from map (MCC) | |
AirCtl_rDesBasEOM0 | 0x07A9 | STAT_AirCtl_rDesBasEOM0_WERT | unsigned int | - | 0.010000 | 0.000000 | AirCtl_rDesBasEOM0 | base value of EGR - position | |
AirCtl_mAirPerCylDesDyn | 0x07AA | STAT_AirCtl_mAirPerCylDesDyn_WERT | unsigned int | mg/hub | 0.100000 | 0.000000 | AirCtl_mAirPerCylDesDyn | dynamically adapted air mass | |
AirCtl_rRatDesDyn | 0x07AB | STAT_AirCtl_rRatDesDyn_WERT | unsigned int | - | 0.010000 | 0.000000 | AirCtl_rRatDesDyn | dynamically adapted total setpoint exhaust gas recirculation rate in the engine | |
AirCtl_rRatGovDvt | 0x07AC | STAT_AirCtl_rRatGovDvt_WERT | unsigned int | - | 0.010000 | 0.000000 | AirCtl_rRatGovDvt | Control deviation of EGR rate | |
AirCtl_rEGREst | 0x07AD | STAT_AirCtl_rEGREst_WERT | unsigned int | % | 0.012207 | 0.000000 | AirCtl_rEGREst | EGR rate - actual value estimated | |
AirCtl_stMonBitsRaw_mp | 0x07AE | STAT_AirCtl_stMonBitsRaw_mp_WERT | unsigned long | - | 1.000000 | 0.000000 | AirCtl_stMonBitsRaw_mp | Bits before TimeToClosedLoop function | |
AirC_stPsCmpr | 0x07B2 | STAT_AirC_stPsCmpr_WERT | unsigned char | - | 1.000000 | 0.000000 | AirC_stPsCmpr | Final digital output to the final stage of the A/C compressor controller | |
AC_trqDes | 0x07BC | STAT_AC_trqDes_WERT | unsigned int | Nm | 0.099988 | -3276.000000 | AC_trqDes | Desired kilmacompressor torque | |
ISKLI | 0x07C6 | STAT_KLIMA_EIN_WERT | unsigned char | - | 1.000000 | 0.000000 | ACCtl_stOut | Status of the air conditioning (on/off) | |
ACCtl_trqMaxAC | 0x07C7 | STAT_ACCtl_trqMaxAC_WERT | unsigned int | Nm | 0.099988 | -3276.000000 | ACCtl_trqMaxAC | Limitation of kilomacompressor torque | |
SMOMO | 0x07D0 | STAT_MOTORMOMENT_SOLL_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | ActMod_trqInr | Current recalculated internal engine torque | |
IMOAK | 0x07D1 | STAT_MOTORMOMENT_AKTUELL_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | ActMod_trq | Current engine torque | |
ActMod_trqClth | 0x07D2 | STAT_ActMod_trqClth_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | ActMod_trqClth | Current clutch torque | |
IADRA | 0x0802 | STAT_DRALLKLAPPENSTELLER_ANSTEUERUNG_WERT | unsigned int | % | 0.001526 | 0.000000 | VSwVlv_rPs | Swirl flap - output duty cycle | |
VSwVlv_rAct | 0x0803 | STAT_VSwVlv_rAct_WERT | unsigned int | % | 0.012207 | 0.000000 | VSwVlv_rAct | Swirl valve - actual position corrected | |
VSwVlv_r | 0x0805 | STAT_VSwVlv_r_WERT | unsigned int | % | 0.001526 | 0.000000 | VSwVlv_r | Swirl damper - set position | |
VSwVlv_rSens | 0x0808 | STAT_VSwVlv_rSens_WERT | unsigned int | % | 0.001526 | 0.000000 | VSwVlv_rSens | Swirl damper - actual position from sensor characteristic curve | |
VSwVlv_uRaw | 0x080A | STAT_VSwVlv_uRaw_WERT | unsigned int | mV | 0.228885 | -5000.000000 | VSwVlv_uRaw | Raw voltage value of the twist damper position sensor | |
ACCI_trqDes | 0x0829 | STAT_ACCI_trqDes_WERT | unsigned int | Nm | 0.236515 | -500.000000 | ACCI_trqDes | Torque request ACC | |
ACCI_trqRaw_mp | 0x082A | STAT_ACCI_trqRaw_mp_WERT | unsigned int | Nm | 0.236515 | -500.000000 | ACCI_trqRaw_mp | ACC torque before monitoring intervention | |
ACCI_stACC | 0x082B | STAT_ACCI_stACC_WERT | unsigned char | - | 1.000000 | 0.000000 | ACCI_stACC | Status of ACC control unit | |
ACCI_dtrqPos_mp | 0x082C | STAT_ACCI_dtrqPos_mp_WERT | unsigned int | Nm/s | 1.541161 | -1000.000000 | ACCI_dtrqPos_mp | Pos. ramp gradient for ACC torque ramp | |
ACCI_dtrqNeg_mp | 0x082D | STAT_ACCI_dtrqNeg_mp_WERT | unsigned int | Nm/s | 1.541161 | -1000.000000 | ACCI_dtrqNeg_mp | Neg. ramp gradient for ACC torque ramp | |
ACCI_trqWhlDesFlt_mp | 0x082E | STAT_ACCI_trqWhlDesFlt_mp_WERT | unsigned int | Nm | 0.018311 | -200.000000 | ACCI_trqWhlDesFlt_mp | Requested wheel torque after filtering | |
ACCI_stCLCTRV | 0x082F | STAT_ACCI_stCLCTRV_WERT | unsigned char | - | 1.000000 | 0.000000 | ACCI_stCLCTRV | Status control speed ACC for transmission on CAN | |
ACCI_stRls | 0x0833 | STAT_ACCI_stRls_WERT | unsigned char | - | 1.000000 | 0.000000 | ACCI_stRls | Enable status for ACC | |
ACCI_stInActv | 0x0834 | STAT_ACCI_stInActv_WERT | unsigned char | - | 1.000000 | 0.000000 | ACCI_stInActv | Status - ACC is not active (for monitoring) | |
AccMon_stLim | 0x0835 | STAT_AccMon_stLim_WERT | unsigned char | - | 1.000000 | 0.000000 | AccMon_stLim | Status of the controller intervention - inactive/active | |
AccMon_trqDesSel | 0x0836 | STAT_AccMon_trqDesSel_WERT | unsigned long | Nm | 0.000015 | 0.000000 | AccMon_trqDesSel | Permissible target torque of level 1 Acceleration monitoring | |
Com_bRecACC | 0x0837 | STAT_Com_bRecACC_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_bRecACC | Self-detection ACC | |
CoVM_trqDes | 0x0838 | STAT_CoVM_trqDes_WERT | unsigned long | Nm | 0.000015 | 0.000000 | CoVM_trqDes | Propulsion target torque after coordination with ESP interventions (wheel torque) | |
CrCtl_stReq | 0x0839 | STAT_CrCtl_stReq_WERT | unsigned char | - | 1.000000 | 0.000000 | CrCtl_stReq | Cruise control is active | |
EpmCrS_stSigMode | 0x083A | STAT_EpmCrS_stSigMode_WERT | unsigned char | - | 1.000000 | 0.000000 | EpmCrS_stSigMode | Status of crankshaft signal evaluation | |
EpmSyn_stCasEval | 0x083B | STAT_EpmSyn_stCasEval_WERT | unsigned char | - | 1.000000 | 0.000000 | EpmSyn_stCasEval | Status of camshaft evaluation | |
InjCrv_qMI1Des | 0x083C | STAT_InjCrv_qMI1Des_WERT | unsigned int | mg/Hub | 0.003891 | 0.000000 | InjCrv_qMI1Des | Desired quantity of main injection | |
InjCrv_qPiI1Des | 0x083D | STAT_InjCrv_qPiI1Des_WERT | unsigned int | mg/Hub | 0.003891 | 0.000000 | InjCrv_qPiI1Des | Desired quantity pre-injection 1 | |
InjCrv_qPiI2Des | 0x083E | STAT_InjCrv_qPiI2Des_WERT | unsigned int | mg/Hub | 0.003891 | 0.000000 | InjCrv_qPiI2Des | Desired quantity pre-injection 2 | |
InjCrv_qPiI3Des | 0x083F | STAT_InjCrv_qPiI3Des_WERT | unsigned int | mg/Hub | 0.003891 | 0.000000 | InjCrv_qPiI3Des | Desired quantity pre-injection 3 | |
InjCrv_qPoI2Des | 0x0840 | STAT_InjCrv_qPoI2Des_WERT | unsigned int | mg/Hub | 0.003891 | 0.000000 | InjCrv_qPoI2Des | Desired quantity post-injection 2 | |
InjCrv_qPoI3Des | 0x0841 | STAT_InjCrv_qPoI3Des_WERT | unsigned int | mg/Hub | 0.003891 | 0.000000 | InjCrv_qPoI3Des | Target quantity post-injection 3 | |
Mo_ctRst | 0x0842 | STAT_Mo_ctRst_WERT | unsigned char | - | 1.000000 | 0.000000 | Mo_ctRst | Reset counter for the Pre-ICO Reset | |
Mo_stICOMsg | 0x0843 | STAT_Mo_stICOMsg_WERT | unsigned char | - | 1.000000 | 0.000000 | Mo_stICOMsg | Injection quantity limitation request of the control units monitoring | |
Mo_stIrvErrReacMsg | 0x0844 | STAT_Mo_stIrvErrReacMsg_WERT | unsigned char | - | 1.000000 | 0.000000 | Mo_stIrvErrReacMsg | Status whether EMB or irrev. CAN error present | |
Mo_stMoC | 0x0845 | STAT_Mo_stMoC_WERT | unsigned char | - | 1.000000 | 0.000000 | Mo_stMoC | Status bit for requesting an error reaction of the function computer monitoring | |
Mo_stMoF | 0x0846 | STAT_Mo_stMoF_WERT | unsigned char | - | 1.000000 | 0.000000 | Mo_stMoF | Status bit for requesting an error response from the function monitor | |
MoCADC_stIrvErrNTP | 0x0847 | STAT_MoCADC_stIrvErrNTP_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCADC_stIrvErrNTP | Irreversible error bit from testing with open-circuit test pulse method | |
MoCADC_stIrvErrTst | 0x0848 | STAT_MoCADC_stIrvErrTst_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCADC_stIrvErrTst | Irreversible error bit from testing the test voltage in ADC monitoring | |
MoCADC_uNTP_mp | 0x0849 | STAT_MoCADC_uNTP_mp_WERT | unsigned int | mV | 1.000000 | 0.000000 | MoCADC_uNTP_mp | Voltage at ADC for accelerator pedal signal 2 | |
MoCADC_uTst_mp | 0x084A | STAT_MoCADC_uTst_mp_WERT | unsigned int | mV | 1.000000 | 0.000000 | MoCADC_uTst_mp | Voltage at ADC test voltage input | |
MoXAMo_stLSUFIdAct | 0x084B | STAT_MoXAMo_stLSUFIdAct_WERT | unsigned char | - | 1.000000 | 0.000000 | MoXAMo_stLSUFIdAct | LSU signal for MoXAMo function iO | |
MoCCom_ctCorRespCnt | 0x084D | STAT_MoCCom_ctCorRespCnt_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCCom_ctCorRespCnt | Counter to count the number of corrections of the response counter | |
MoCCom_stWDAActvMsg | 0x084E | STAT_MoCCom_stWDAActvMsg_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCCom_stWDAActvMsg | Info at level 1: Watchdog shutdown active | |
MoCMem_adCurrent | 0x084F | STAT_MoCMem_adCurrent_WERT | unsigned long | - | 1.000000 | 0.000000 | MoCMem_adCurrent | Current address pointer for the cyclic ROM check | |
MoCMem_adRamOffset | 0x0850 | STAT_MoCMem_adRamOffset_WERT | unsigned long | - | 1.000000 | 0.000000 | MoCMem_adRamOffset | Current offset for the cyclic RAM check | |
MoCMem_ctDebErrChkRAM | 0x0851 | STAT_MoCMem_ctDebErrChkRAM_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCMem_ctDebErrChkRAM | Error counter for double storage error and cyclic RAM test | |
MoCMem_ctDebErrChkROM | 0x0852 | STAT_MoCMem_ctDebErrChkROM_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCMem_ctDebErrChkROM | Error counter for cyclic ROM test | |
MoCMem_ctDebHealChkRAM | 0x0853 | STAT_MoCMem_ctDebHealChkRAM_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCMem_ctDebHealChkRAM | Healing counters for double storage error and cyclic RAM test | |
MoCMem_ctDebHealChkROM | 0x0854 | STAT_MoCMem_ctDebHealChkROM_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCMem_ctDebHealChkROM | Healing counter for cyclic ROM test | |
MoCMem_numCurrent | 0x0855 | STAT_MoCMem_numCurrent_WERT | unsigned long | - | 1.000000 | 0.000000 | MoCMem_numCurrent | Current checksum for cyclic ROM check | |
MoCMem_stFunctionSwitch | 0x0856 | STAT_MoCMem_stFunctionSwitch_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCMem_stFunctionSwitch | Variable switches between monitored ROM code and ROM data area | |
MoCPCP_adCurrent | 0x0857 | STAT_MoCPCP_adCurrent_WERT | unsigned long | - | 1.000000 | 0.000000 | MoCPCP_adCurrent | Current address pointer for PCP code check | |
MoCPCP_ctErr | 0x0858 | STAT_MoCPCP_ctErr_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCPCP_ctErr | Error counter for CRC checksum calculation | |
MoCPCP_ctHeal | 0x0859 | STAT_MoCPCP_ctHeal_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCPCP_ctHeal | Cure counter for CRC checksum error | |
MoCPCP_numCurrentCSum | 0x085A | STAT_MoCPCP_numCurrentCSum_WERT | unsigned long | - | 1.000000 | 0.000000 | MoCPCP_numCurrentCSum | Current checksum for PCP code verification | |
MoCRam_ctMain1RamChk | 0x085B | STAT_MoCRam_ctMain1RamChk_WERT | unsigned long | us | 1.000000 | 0.000000 | MoCRam_ctMain1RamChk | Diagnostic counter for the time of the RAM check over the areas in MAIN 1. | |
MoCRam_ctMain2RamChk | 0x085C | STAT_MoCRam_ctMain2RamChk_WERT | unsigned long | us | 1.000000 | 0.000000 | MoCRam_ctMain2RamChk | Diagnostic counter for the time of the RAM check over the areas in MAIN 2 (excl. protected RAM size). | |
MoCRam_ctMainProtRam | 0x085D | STAT_MoCRam_ctMainProtRam_WERT | unsigned long | us | 1.000000 | 0.000000 | MoCRam_ctMainProtRam | Diagnostic counters for the time of the RAM check over the areas of the protected RAM. | |
MoCRam_ctRepEx | 0x085E | STAT_MoCRam_ctRepEx_WERT | unsigned long | us | 1.000000 | 0.000000 | MoCRam_ctRepEx | Diagnostic counter for the time of the RAM check over the areas of the retry check | |
MoCRam_numAreasChecked | 0x085F | STAT_MoCRam_numAreasChecked_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCRam_numAreasChecked | Diagnostic size for the number of areas currently checked. | |
MoCRam_numReset | 0x0860 | STAT_MoCRam_numReset_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCRam_numReset | Diagnostic quantity for resets triggered during start-up | |
MoCRam_stEEPInit | 0x0861 | STAT_MoCRam_stEEPInit_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCRam_stEEPInit | Diagnostic size for values transferred in the init for MoCMem_st from the EEPROM | |
MoCRam_stProtRAMCleared | 0x0862 | STAT_MoCRam_stProtRAMCleared_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCRam_stProtRAMCleared | Status variable for Protected-RAM status | |
MoCRam_stRepExRam | 0x0863 | STAT_MoCRam_stRepExRam_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCRam_stRepExRam | Status variable for whether a retry check was carried out | |
MoCRom_ctRepEx_mp | 0x0864 | STAT_MoCRom_ctRepEx_mp_WERT | unsigned long | us | 1.000000 | 0.000000 | MoCRom_ctRepEx_mp | Diagnostic counter for the time of the ROM check over the areas of the repeat check. | |
MoCRom_KeyCode | 0x0865 | STAT_MoCRom_KeyCode_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCRom_KeyCode | Variable for deactivating the complete ROM check via code | |
MoCRom_KeyData | 0x0866 | STAT_MoCRom_KeyData_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCRom_KeyData | Variable for disabling the complete ROM check over data. | |
MoCRom_stXPostDrv_mp | 0x0867 | STAT_MoCRom_stXPostDrv_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCRom_stXPostDrv_mp | Requirement for the detection of an extension of the overrun. | |
MoCSOP_ctDebHwNoRdy | 0x0868 | STAT_MoCSOP_ctDebHwNoRdy_WERT | unsigned int | - | 1.000000 | 0.000000 | MoCSOP_ctDebHwNoRdy | Number of repetitions until the hardware is ready to perform the shutdown path test. | |
MoCSOP_ctDebPSIni | 0x0869 | STAT_MoCSOP_ctDebPSIni_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_ctDebPSIni | Number of attempts to initiate injection | |
MoCSOP_ctErrMMRespByte | 0x086A | STAT_MoCSOP_ctErrMMRespByte_WERT | unsigned int | - | 1.000000 | 0.000000 | MoCSOP_ctErrMMRespByte | Byte counter for the response to the monitoring module | |
MoCSOP_ctErrRespTime | 0x086B | STAT_MoCSOP_ctErrRespTime_WERT | unsigned int | - | 1.000000 | 0.000000 | MoCSOP_ctErrRespTime | Error counter when setting the response time | |
MoCSOP_ctRst | 0x086C | STAT_MoCSOP_ctRst_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_ctRst | Number of resets triggered in the shutdown path test | |
MoCSOP_stIVHSOPTst_mp | 0x086D | STAT_MoCSOP_stIVHSOPTst_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stIVHSOPTst_mp | Return value of IVHSOPTst as array | |
MoCSOP_stOvl | 0x086E | STAT_MoCSOP_stOvl_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stOvl | Status variable of the CJ945 overvoltage detection latch | |
MoCSOP_tiResp | 0x086F | STAT_MoCSOP_tiResp_WERT | unsigned long | - | 1.000000 | 0.000000 | MoCSOP_tiResp | Monitoring module response time | |
MoFAPP_stDiff_mp | 0x0870 | STAT_MoFAPP_stDiff_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFAPP_stDiff_mp | Implausibility when comparing the two accelerator pedal signals | |
MoFAPP_stLimpMsg | 0x0871 | STAT_MoFAPP_stLimpMsg_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFAPP_stLimpMsg | Info for level 1: Error response requested from level 2 | |
MoFAPP_uRaw1_mp | 0x0872 | STAT_MoFAPP_uRaw1_mp_WERT | unsigned char | mV | 19.531250 | 0.000000 | MoFAPP_uRaw1_mp | Current value for accelerator pedal signal 1 | |
MoFAPP_uRaw2_mp | 0x0873 | STAT_MoFAPP_uRaw2_mp_WERT | unsigned char | mV | 9.765625 | 0.000000 | MoFAPP_uRaw2_mp | Current value for accelerator pedal signal 2 | |
MoFClth_st | 0x0874 | STAT_MoFClth_st_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFClth_st | Clutch status | |
MoFDCS_stFrz_mp | 0x0875 | STAT_MoFDCS_stFrz_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFDCS_stFrz_mp | Status of the temporary defect detection of the DSC message | |
MoFDCS_stTCSDem | 0x0876 | STAT_MoFDCS_stTCSDem_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFDCS_stTCSDem | Status of the ASR intervention in the function monitor | |
MoFDCS_trqDem | 0x0877 | STAT_MoFDCS_trqDem_WERT | unsigned int | Nm | 1.000000 | 0.000000 | MoFDCS_trqDem | Requested engine torque from MSR controller | |
MoFDCS_trqRaw_mp | 0x0878 | STAT_MoFDCS_trqRaw_mp_WERT | unsigned int | Nm | 1.000000 | 0.000000 | MoFDCS_trqRaw_mp | Raw value of the torque request of the DCS CAN message | |
MoFESpd_nEngL2_mp | 0x0879 | STAT_MoFESpd_nEngL2_mp_WERT | unsigned char | rpm | 40.000000 | 0.000000 | MoFESpd_nEngL2_mp | Engine speed calculated in the function monitor | |
MoFESpd_stSync1 | 0x087A | STAT_MoFESpd_stSync1_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFESpd_stSync1 | Identifier 1 for synchronisation in function monitoring | |
MoFESpd_stSync2 | 0x087B | STAT_MoFESpd_stSync2_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFESpd_stSync2 | Identifier 2 for synchronisation in function monitoring | |
MoFExtInt_stDCSPtdMsg | 0x087C | STAT_MoFExtInt_stDCSPtdMsg_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFExtInt_stDCSPtdMsg | Status of the MSR intervention permissibility from level 2 to level 1 | |
MoFInjDat_numCylActr_mp | 0x087D | STAT_MoFInjDat_numCylActr_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFInjDat_numCylActr_mp | Cylinder number injection place specific | |
MoFInjDat_numInjType_mp | 0x087E | STAT_MoFInjDat_numInjType_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFInjDat_numInjType_mp | Injection type injection-specific | |
MoFSpdG_stDem | 0x087F | STAT_MoFSpdG_stDem_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFSpdG_stDem | Status of general speed requirements | |
MoFTra_stDem | 0x0880 | STAT_MoFTra_stDem_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFTra_stDem | Status of the permissibility of the transmission intervention in the function monitoring | |
MoFVehAcc_st | 0x0881 | STAT_MoFVehAcc_st_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFVehAcc_st | Bit-coded status of acceleration monitoring in the function monitor | |
MoFVSS_a | 0x0882 | STAT_MoFVSS_a_WERT | unsigned int | m/s^2 | 0.001000 | 0.000000 | MoFVSS_a | Vehicle acceleration for function monitoring | |
MoFVSS_stErrVSS | 0x0883 | STAT_MoFVSS_stErrVSS_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFVSS_stErrVSS | MoFVSS_stErrVSS | |
MoFVSS_vAccMon | 0x0884 | STAT_MoFVSS_vAccMon_WERT | unsigned int | km/h | 0.010000 | 0.000000 | MoFVSS_vAccMon | Vehicle speed with calculated substitute value in the event of an error in function monitoring | |
Reset_xHistBuf_0 | 0x0885 | STAT_Reset_xHistBuf0_WERT | unsigned int | - | 1.000000 | 0.000000 | Reset_xHistBuf_0 | Ring buffer with the last 8 reset IDs 0 | |
Reset_xHistBuf_1 | 0x0886 | STAT_Reset_xHistBuf1_WERT | unsigned int | - | 1.000000 | 0.000000 | Reset_xHistBuf_1 | Ring memory with the last 8 reset IDs 1 | |
Reset_xHistBuf_2 | 0x0887 | STAT_Reset_xHistBuf2_WERT | unsigned int | - | 1.000000 | 0.000000 | Reset_xHistBuf_2 | Ring memory with the last 8 reset IDs 2 | |
Reset_xHistBuf_3 | 0x0888 | STAT_Reset_xHistBuf3_WERT | unsigned int | - | 1.000000 | 0.000000 | Reset_xHistBuf_3 | Ring buffer with the last 8 reset IDs 3 | |
Reset_xHistBuf_4 | 0x0889 | STAT_Reset_xHistBuf4_WERT | unsigned int | - | 1.000000 | 0.000000 | Reset_xHistBuf_4 | Ring buffer with the last 8 reset ID's 4 | |
Reset_xHistBuf_5 | 0x088A | STAT_Reset_xHistBuf5_WERT | unsigned int | - | 1.000000 | 0.000000 | Reset_xHistBuf_5 | Ring buffer with the last 8 reset ID's 5 | |
Reset_xHistBuf_6 | 0x088B | STAT_Reset_xHistBuf6_WERT | unsigned int | - | 1.000000 | 0.000000 | Reset_xHistBuf_6 | Ring buffer with the last 8 reset ID's 6 | |
Reset_xHistBuf_7 | 0x088C | STAT_Reset_xHistBuf7_WERT | unsigned int | - | 1.000000 | 0.000000 | Reset_xHistBuf_7 | Ring buffer with the last 8 reset IDs 7 | |
StbIntv_bDCSIntv | 0x088D | STAT_StbIntv_bDCSIntv_WERT | unsigned char | - | 1.000000 | 0.000000 | StbIntv_bDCSIntv | Enable for torque requests from the drag torque control (MSR) | |
StbIntv_bDCSNeutr | 0x088E | STAT_StbIntv_bDCSNeutr_WERT | unsigned char | - | 1.000000 | 0.000000 | StbIntv_bDCSNeutr | Neutral value received for torque requests from the drag torque control (TCRC) | |
VehMot_trqDCS | 0x088F | STAT_VehMot_trqDCS_WERT | unsigned long | Nm | 0.000015 | 0.000000 | VehMot_trqDCS | MSR intervention torque (gearbox output torque) | |
VMSI_stDCS | 0x0890 | STAT_VMSI_stDCS_WERT | unsigned int | - | 1.000000 | 0.000000 | VMSI_stDCS | Status MSR intervention | |
VMSI_stDCSPtd | 0x0891 | STAT_VMSI_stDCSPtd_WERT | unsigned char | - | 1.000000 | 0.000000 | VMSI_stDCSPtd | Increased stability intervention from level 1 prohibited | |
MoFVSS_stSlip | 0x0892 | STAT_MoFVSS_stSlip_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFVSS_stSlip | MoFVSS_stSlip | |
MoFVSS_stErrWhlSpd | 0x0893 | STAT_MoFVSS_stErrWhlSpd_WERT | unsigned int | - | 1.000000 | 0.000000 | MoFVSS_stErrWhlSpd | MoFVSS_stErrWhlSpd | |
MoFVSS_stFrzWhlSpd | 0x0894 | STAT_MoFVSS_stFrzWhlSpd_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFVSS_stFrzWhlSpd | MoFVSS_stFrzWhlSpd | |
MoFVSS_stFrzVSS | 0x0895 | STAT_MoFVSS_stFrzVSS_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFVSS_stFrzVSS | MoFVSS_stFrzVSS | |
ISC_trq | 0x0899 | STAT_ISC_trq_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | ISC_trq | Positioning value of the ISC torque | |
ISC_st_0 | 0x089A | STAT_ISC_st0_WERT | unsigned long | - | 1.000000 | 0.000000 | ISC_st_0 | Status information of the ISC and its clients for cylinder 1 | |
ISC_st_1 | 0x089B | STAT_ISC_st1_WERT | unsigned long | - | 1.000000 | 0.000000 | ISC_st_1 | Status information of the ISC and its clients for cylinder 2 | |
ISC_st_2 | 0x089C | STAT_ISC_st2_WERT | unsigned long | - | 1.000000 | 0.000000 | ISC_st_2 | Status information of the ISC and its clients for cylinder 3 | |
ISC_st_3 | 0x089D | STAT_ISC_st3_WERT | unsigned long | - | 1.000000 | 0.000000 | ISC_st_3 | Status information of the ISC and its clients for cylinder 4 | |
ISC_st_4 | 0x089E | STAT_ISC_st4_WERT | unsigned long | - | 1.000000 | 0.000000 | ISC_st_4 | Status information of the ISC and its clients for cylinder 5 | |
ISC_st_5 | 0x089F | STAT_ISC_st5_WERT | unsigned long | - | 1.000000 | 0.000000 | ISC_st_5 | Status information of the ISC and its clients for cylinder 6 | |
ISC_nSetPLo_0 | 0x08FC | STAT_ISC_nSetPLo0_WERT | unsigned int | rpm | 0.091554 | 0.000000 | ISC_nSetPLo_0 | Lower speed interval limit (set speed) of the ISC for cylinder 1 | |
ISC_nSetPLo_1 | 0x08FD | STAT_ISC_nSetPLo1_WERT | unsigned int | rpm | 0.091554 | 0.000000 | ISC_nSetPLo_1 | Lower speed interval limit (set speed) of the ISC for cylinder 2 | |
ISC_nSetPLo_2 | 0x08FE | STAT_ISC_nSetPLo2_WERT | unsigned int | rpm | 0.091554 | 0.000000 | ISC_nSetPLo_2 | Lower speed interval limit (set speed) of the ISC for cylinder 3 | |
ISC_nSetPLo_3 | 0x08FF | STAT_ISC_nSetPLo3_WERT | unsigned int | rpm | 0.091554 | 0.000000 | ISC_nSetPLo_3 | Lower speed interval limit (setpoint speed) of the ISC for cylinder 4 | |
IVActr_uUp_0 | 0x090E | STAT_IVActr_uUp0_WERT | unsigned int | V | 0.010000 | 0.000000 | IVActr_uUp_0 | Actuator voltage up level 0 | |
IVActr_uUp_1 | 0x090F | STAT_IVActr_uUp1_WERT | unsigned int | V | 0.010000 | 0.000000 | IVActr_uUp_1 | Actuator voltage up level 1 | |
IVActr_uUp_2 | 0x0910 | STAT_IVActr_uUp2_WERT | unsigned int | V | 0.010000 | 0.000000 | IVActr_uUp_2 | Actuator voltage up level 2 | |
IVActr_uUp_3 | 0x0911 | STAT_IVActr_uUp3_WERT | unsigned int | V | 0.010000 | 0.000000 | IVActr_uUp_3 | Actuator voltage up level 3 | |
IVCtl_iChrg_0 | 0x091E | STAT_IVCtl_iChrg0_WERT | unsigned int | mA | 1.000000 | 0.000000 | IVCtl_iChrg_0 | Charge current limit 0 | |
IVCtl_iChrg_1 | 0x091F | STAT_IVCtl_iChrg1_WERT | unsigned int | mA | 1.000000 | 0.000000 | IVCtl_iChrg_1 | Charge current limit 1 | |
IVCtl_iChrg_2 | 0x0920 | STAT_IVCtl_iChrg2_WERT | unsigned int | mA | 1.000000 | 0.000000 | IVCtl_iChrg_2 | Charge current limit 2 | |
IVCtl_iChrg_3 | 0x0921 | STAT_IVCtl_iChrg3_WERT | unsigned int | mA | 1.000000 | 0.000000 | IVCtl_iChrg_3 | Charge current limit 3 | |
IVAdj_clsIVA_0 | 0x092E | STAT_IVAdj_clsIVA0_WERT | unsigned char | - | 1.000000 | 0.000000 | IVAdj_clsIVA_0 | Injector voltage calibration class of the piezo actuator 0 | |
IVAdj_clsIVA_1 | 0x092F | STAT_IVAdj_clsIVA1_WERT | unsigned char | - | 1.000000 | 0.000000 | IVAdj_clsIVA_1 | Injector voltage calibration class of piezo actuator 1 | |
IVAdj_clsIVA_2 | 0x0930 | STAT_IVAdj_clsIVA2_WERT | unsigned char | - | 1.000000 | 0.000000 | IVAdj_clsIVA_2 | Injector voltage calibration class of piezo actuator 2 | |
IVAdj_clsIVA_3 | 0x0931 | STAT_IVAdj_clsIVA3_WERT | unsigned char | - | 1.000000 | 0.000000 | IVAdj_clsIVA_3 | Injector voltage calibration class of the piezo actuator 3 | |
IVAdj_ctImaProg_mp | 0x0938 | STAT_IVAdj_ctImaProg_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | IVAdj_ctImaProg_mp | Counter for injector programming for resetting the injector quantity. | |
FlSys_qFlTotInj | 0x0939 | STAT_FlSys_qFlTotInj_WERT | unsigned int | l | 1.000000 | 0.000000 | FlSys_qFlTotInj | Total flow rate through the injector | |
FlSys_volTotFlCons | 0x093A | STAT_FlSys_volTotFlCons_WERT | unsigned long | l | 0.500000 | 0.000000 | FlSys_volTotFlCons | Total fuel quantity | |
IVCtl_uUp_0 | 0x094C | STAT_IVCtl_uUp0_WERT | unsigned int | V | 0.010000 | 0.000000 | IVCtl_uUp_0 | Voltage setpoint up level 0 | |
IVCtl_uUp_1 | 0x094D | STAT_IVCtl_uUp1_WERT | unsigned int | V | 0.010000 | 0.000000 | IVCtl_uUp_1 | Voltage setpoint up level 1 | |
IVCtl_uUp_2 | 0x094E | STAT_IVCtl_uUp2_WERT | unsigned int | V | 0.010000 | 0.000000 | IVCtl_uUp_2 | Voltage setpoint up level 2 | |
IVCtl_uUp_3 | 0x094F | STAT_IVCtl_uUp3_WERT | unsigned int | V | 0.010000 | 0.000000 | IVCtl_uUp_3 | Voltage setpoint up level 3 | |
IVCtl_tiChrg | 0x0955 | STAT_IVCtl_tiChrg_WERT | unsigned int | us | 0.400000 | 0.000000 | IVCtl_tiChrg | Charge time setpoint | |
IVDia_stErrCyl_mp_0 | 0x0957 | STAT_IVDia_stErrCyl_mp0_WERT | unsigned char | - | 1.000000 | 0.000000 | IVDia_stErrCyl_mp_0 | Cylinder-specific diagnostic information 0 | |
IVDia_stErrCyl_mp_1 | 0x0958 | STAT_IVDia_stErrCyl_mp1_WERT | unsigned char | - | 1.000000 | 0.000000 | IVDia_stErrCyl_mp_1 | Cylinder-specific diagnostic information 1 | |
IVDia_stErrCyl_mp_2 | 0x0959 | STAT_IVDia_stErrCyl_mp2_WERT | unsigned char | - | 1.000000 | 0.000000 | IVDia_stErrCyl_mp_2 | Cylinder-specific diagnostic information 2 | |
IVDia_stErrCyl_mp_3 | 0x095A | STAT_IVDia_stErrCyl_mp3_WERT | unsigned char | - | 1.000000 | 0.000000 | IVDia_stErrCyl_mp_3 | Cylinder-specific diagnostic information 3 | |
IVDia_stErrClctComplCyl_mp_0 | 0x095D | STAT_IVDia_stErrClctComplCyl_mp0_WERT | unsigned int | - | 1.000000 | 0.000000 | IVDia_stErrClctComplCyl_mp_0 | Complete lowlevel error message for CY33x preprocessed per cylinder 0 | |
IVDia_stErrClctComplCyl_mp_1 | 0x095E | STAT_IVDia_stErrClctComplCyl_mp1_WERT | unsigned int | - | 1.000000 | 0.000000 | IVDia_stErrClctComplCyl_mp_1 | Full lowlevel error message for CY33x preprocessed per cylinder 1 | |
IVDia_stErrClctComplCyl_mp_2 | 0x095F | STAT_IVDia_stErrClctComplCyl_mp2_WERT | unsigned int | - | 1.000000 | 0.000000 | IVDia_stErrClctComplCyl_mp_2 | Complete lowlevel error message for CY33x preprocessed per cylinder 2 | |
IVDia_stErrClctComplCyl_mp_3 | 0x0960 | STAT_IVDia_stErrClctComplCyl_mp3_WERT | unsigned int | - | 1.000000 | 0.000000 | IVDia_stErrClctComplCyl_mp_3 | Complete lowlevel error message for CY33x preprocessed per cylinder 3 | |
IVDia_stErrClctPsIcCyl_mp_0 | 0x0963 | STAT_IVDia_stErrClctPsIcCyl_mp0_WERT | unsigned int | - | 1.000000 | 0.000000 | IVDia_stErrClctPsIcCyl_mp_0 | Collective error measuring point from diagnostic register for CY33x 0 | |
IVDia_stErrClctPsIcCyl_mp_1 | 0x0964 | STAT_IVDia_stErrClctPsIcCyl_mp1_WERT | unsigned int | - | 1.000000 | 0.000000 | IVDia_stErrClctPsIcCyl_mp_1 | Collective error measuring point from diagnostic register for CY33x 1 | |
IVDia_stErrClctPsIcCyl_mp_2 | 0x0965 | STAT_IVDia_stErrClctPsIcCyl_mp2_WERT | unsigned int | - | 1.000000 | 0.000000 | IVDia_stErrClctPsIcCyl_mp_2 | Collective error measuring point from diagnostic register for CY33x 2 | |
IVDia_stErrClctPsIcCyl_mp_3 | 0x0966 | STAT_IVDia_stErrClctPsIcCyl_mp3_WERT | unsigned int | - | 1.000000 | 0.000000 | IVDia_stErrClctPsIcCyl_mp_3 | Collective error measuring point from diagnostic register for CY33x 3 | |
IVDia_stPsIcChp_0 | 0x0969 | STAT_IVDia_stPsIcChp_WERT | unsigned int | - | 1.000000 | 0.000000 | IVDia_stPsIcChp_0 | chip-specific diagnostic information of SPI transmission and SPI control byte 0 | |
IVAdj_facNVC_0 | 0x0992 | STAT_IVAdj_facNVC0_WERT | unsigned int | - | 0.000122 | 0.000000 | IVAdj_facNVC_0 | NVC correction factor 0 | |
IVAdj_facNVC_1 | 0x0993 | STAT_IVAdj_facNVC1_WERT | unsigned int | - | 0.000122 | 0.000000 | IVAdj_facNVC_1 | NVC correction factor 1 | |
IVAdj_facNVC_2 | 0x0994 | STAT_IVAdj_facNVC2_WERT | unsigned int | - | 0.000122 | 0.000000 | IVAdj_facNVC_2 | NVC correction factor 2 | |
IVAdj_facNVC_3 | 0x0995 | STAT_IVAdj_facNVC3_WERT | unsigned int | - | 0.000122 | 0.000000 | IVAdj_facNVC_3 | NVC correction factor 3 | |
IVDia_stErrClctChp_mp_0 | 0x09A2 | STAT_IVDia_stErrClctChp_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | IVDia_stErrClctChp_mp_0 | Chip error (collective byte) 0 | |
InjCrv_stInjCharActVal | 0x09A3 | STAT_InjCrv_stInjCharActVal_WERT | unsigned char | - | 1.000000 | 0.000000 | InjCrv_stInjCharActVal | Injection enable status | |
IVAdj_facNVCEepWrI_mp_0 | 0x09A6 | STAT_IVAdj_facNVCEepWrI_mp0_WERT | unsigned int | - | 0.000122 | 0.000000 | IVAdj_facNVCEepWrI_mp_0 | Value of NVC-I controller stored in EEPROM 0 | |
IVAdj_facNVCEepWrI_mp_1 | 0x09A7 | STAT_IVAdj_facNVCEepWrI_mp1_WERT | unsigned int | - | 0.000122 | 0.000000 | IVAdj_facNVCEepWrI_mp_1 | Value of NVC-I controller stored in EEPROM 1 | |
IVAdj_facNVCEepWrI_mp_2 | 0x09A8 | STAT_IVAdj_facNVCEepWrI_mp2_WERT | unsigned int | - | 0.000122 | 0.000000 | IVAdj_facNVCEepWrI_mp_2 | Value of NVC-I controller stored in EEPROM 2 | |
IVAdj_facNVCEepWrI_mp_3 | 0x09A9 | STAT_IVAdj_facNVCEepWrI_mp3_WERT | unsigned int | - | 0.000122 | 0.000000 | IVAdj_facNVCEepWrI_mp_3 | Value of NVC-I controller stored in EEPROM 3 | |
IVAdj_facNVCInitI_mp_0 | 0x09B0 | STAT_IVAdj_facNVCInitI_mp0_WERT | unsigned int | - | 0.000122 | 0.000000 | IVAdj_facNVCInitI_mp_0 | Initialisation value of the NVC-I controller 0 | |
IVAdj_facNVCInitI_mp_1 | 0x09B1 | STAT_IVAdj_facNVCInitI_mp1_WERT | unsigned int | - | 0.000122 | 0.000000 | IVAdj_facNVCInitI_mp_1 | Initialisation value of the NVC-I controller 1 | |
IVAdj_facNVCInitI_mp_2 | 0x09B2 | STAT_IVAdj_facNVCInitI_mp2_WERT | unsigned int | - | 0.000122 | 0.000000 | IVAdj_facNVCInitI_mp_2 | Initialisation value of NVC-I controller 2 | |
IVAdj_facNVCInitI_mp_3 | 0x09B3 | STAT_IVAdj_facNVCInitI_mp3_WERT | unsigned int | - | 0.000122 | 0.000000 | IVAdj_facNVCInitI_mp_3 | Initialisation value of NVC-I controller 3 | |
IVAdj_lTotDst_mp | 0x09B6 | STAT_IVAdj_lTotDst_mp_WERT | unsigned long | m | 1.000000 | 0.000000 | IVAdj_lTotDst_mp | IVAdj_lTotDst_mp | |
Fan_rPs | 0x09C4 | STAT_Fan_rPs_WERT | unsigned int | % | 0.001526 | 0.000000 | Fan_rPs | Electric fan - output duty cycle | |
Fan_stDesStg | 0x09C6 | STAT_Fan_stDesStg_WERT | unsigned char | - | 1.000000 | 0.000000 | Fan_stDesStg | Status of the currently functionally requested fan stage by the fan control. | |
Fan_stPs2 | 0x09C7 | STAT_Fan_stPs2_WERT | unsigned char | - | 1.000000 | 0.000000 | Fan_stPs2 | Status of 2-stage digital electric fan control | |
FanCtl_nSetPoint | 0x09CE | STAT_FanCtl_nSetPoint_WERT | unsigned int | rpm | 0.152590 | -5000.000000 | FanCtl_nSetPoint | Speed of the electric fan | |
Gangi | 0x09F6 | STAT_Gangi_WERT | unsigned char | - | 1.000000 | 0.000000 | Gangi | Current gear internal | |
IGABE | 0x09F7 | STAT_BERECHNETER_GANG_WERT | unsigned char | - | 1.000000 | 0.000000 | Gbx_numGear | engaged gear | |
IGETT | 0x09F8 | STAT_GETRIEBETYP_WERT | unsigned char | - | 1.000000 | 0.000000 | PT_stTraType | Current gear type | |
IKSAB | 0x0A28 | STAT_SAUERSTOFFGEHALT_BERECHNET_WERT | unsigned int | - | 0.000381 | 0.000000 | LSU_rO2Adap_0 | Adapted oxygen concentration 0 | |
LSU_rO2Adap_1 | 0x0A29 | STAT_LSU_rO2Adap_1_WERT | unsigned int | - | 0.000381 | 0.000000 | LSU_rO2Adap_1 | Adapted oxygen concentration 1 | |
ILMBD0 | 0x0A2C | STAT_LAMBDA0_WERT | unsigned int | - | 0.001000 | 0.000000 | LSU_rLam_0 | The lambda value measured from LSU 0 | |
ILMBD1 | 0x0A2D | STAT_LAMBDA1_WERT | unsigned int | - | 0.001000 | 0.000000 | LSU_rLam_1 | The lambda value measured from LSU 1 | |
ISOSV | 0x0A30 | STAT_LAMBDASONDENSIGNAL_VALID | unsigned char | 0/1 | 1.000000 | 0.000000 | LSU_stO2IntValid | Oxygen signal valid (internal) | |
LSU_stO2IntValid_1 | 0x0A31 | STAT_LSU_stO2IntValid_1_WERT | unsigned char | - | 1.000000 | 0.000000 | LSU_stO2IntValid_1 | Oxygen signal valid (internal) 1 | |
LSU_rO2Raw | 0x0A32 | STAT_LSU_rO2Raw_WERT | unsigned int | - | 0.000010 | 0.000000 | LSU_rO2Raw | Raw oxygen value, offset compensated only | |
LSU_stAdap | 0x0A34 | STAT_LSU_stAdap_WERT | unsigned char | - | 1.000000 | 0.000000 | LSU_stAdap | Filtered oxygen value | |
LSU_tiState1_mp_0 | 0x0A36 | STAT_LSU_tiState1_mp_0_WERT | unsigned int | s | 0.100000 | 0.000000 | LSU_tiState1_mp_0 | Timer variable: fuel quantity is within tolerance band 0 | |
LSU_tiState1_mp_1 | 0x0A37 | STAT_LSU_tiState1_mp_1_WERT | unsigned int | s | 0.100000 | 0.000000 | LSU_tiState1_mp_1 | Timer variable: fuel quantity is within tolerance band 1 | |
LSU_tiState2_mp_0 | 0x0A38 | STAT_LSU_tiState2_mp_0_WERT | unsigned int | s | 0.100000 | 0.000000 | LSU_tiState2_mp_0 | Rise time O2 signal at load-thrust transition 0 | |
LSU_tiState2_mp_1 | 0x0A39 | STAT_LSU_tiState2_mp_1_WERT | unsigned int | s | 0.100000 | 0.000000 | LSU_tiState2_mp_1 | Rise time of O2 signal at transition from load to thrust 1 | |
LSU_tiState3_mp_0 | 0x0A3A | STAT_LSU_tiState3_mp_0_WERT | unsigned int | s | 0.100000 | 0.000000 | LSU_tiState3_mp_0 | Time until thrust is reached (fuel quantity less than threshold value) 0 | |
LSU_tiState3_mp_1 | 0x0A3B | STAT_LSU_tiState3_mp_1_WERT | unsigned int | s | 0.100000 | 0.000000 | LSU_tiState3_mp_1 | Time until thrust is reached (fuel quantity less than threshold value) 1 | |
LamCtl_stGov | 0x0A3C | STAT_LamCtl_stGov_WERT | unsigned char | - | 1.000000 | 0.000000 | LamCtl_stGov | Status - Lamda controller active | |
LamCtl_qLamDynDesCor_mp | 0x0A3D | STAT_LamCtl_qLamDynDesCor_mp_WERT | unsigned int | mg/Hub | 0.001000 | -32.657000 | LamCtl_qLamDynDesCor_mp | fraction fuel injection quantity from the lambda governor | |
LSU_facO2Cor_mp_0 | 0x0A40 | STAT_LSU_facO2Cor_mp_0_WERT | unsigned int | - | 0.001526 | -50.000000 | LSU_facO2Cor_mp_0 | Adjustment correction factor 0 | |
LSU_facO2Cor_mp_1 | 0x0A41 | STAT_LSU_facO2Cor_mp_1_WERT | unsigned int | - | 0.001526 | -50.000000 | LSU_facO2Cor_mp_1 | Adjustment correction factor 1 | |
LSU_uO2RawAdcDirect_0 | 0x0A42 | STAT_LSU_uO2RawAdcDirect_0_WERT | unsigned int | mV | 0.199991 | -6553.000000 | LSU_uO2RawAdcDirect_0 | Direct O2 signal value from the ADC 0 | |
LSU_uO2RawAdcDirect_1 | 0x0A43 | STAT_LSU_uO2RawAdcDirect_1_WERT | unsigned int | mV | 0.199991 | -6553.000000 | LSU_uO2RawAdcDirect_1 | Direct O2 signal value from the ADC 1 | |
LSU_uO2Flt_0 | 0x0A44 | STAT_LSU_uO2Flt_0_WERT | unsigned int | mV | 0.199991 | -6553.000000 | LSU_uO2Flt_0 | Filtered value of the raw O2 signal 0 | |
LSU_uO2Flt_1 | 0x0A45 | STAT_LSU_uO2Flt_1_WERT | unsigned int | mV | 0.199991 | -6553.000000 | LSU_uO2Flt_1 | Filtered value of the raw O2 signal 1 | |
LSU_uO2FltOfsCor_0 | 0x0A46 | STAT_LSU_uO2FltOfsCor_0_WERT | unsigned int | mV | 0.199991 | -6553.000000 | LSU_uO2FltOfsCor_0 | Filtered and corrected O2 voltage signal 0 | |
LSU_uO2FltOfsCor_1 | 0x0A47 | STAT_LSU_uO2FltOfsCor_1_WERT | unsigned int | mV | 0.199991 | -6553.000000 | LSU_uO2FltOfsCor_1 | Filtered and corrected O2 voltage signal 1 | |
LSU_rO2PresComp_0 | 0x0A48 | STAT_LSU_rO2PresComp_0_WERT | unsigned int | - | 0.000010 | -0.327600 | LSU_rO2PresComp_0 | Pressure corrected oxygen value 0 | |
LSU_rO2PresComp_1 | 0x0A49 | STAT_LSU_rO2PresComp_1_WERT | unsigned int | - | 0.000010 | -0.327600 | LSU_rO2PresComp_1 | Pressure corrected oxygen value 1 | |
LSU_rO2PresTempComp_0 | 0x0A4A | STAT_LSU_rO2PresTempComp_0_WERT | unsigned int | - | 0.000010 | -0.327600 | LSU_rO2PresTempComp_0 | Temperature- and pressure-compensated O2 concentration 0 | |
LSU_rO2PresTempComp_1 | 0x0A4B | STAT_LSU_rO2PresTempComp_1_WERT | unsigned int | - | 0.000010 | -0.327600 | LSU_rO2PresTempComp_1 | Temperature- and pressure-compensated O2 concentration 1 | |
LSU_stAdapActv_0 | 0x0A4C | STAT_LSU_stAdapActv_0_WERT | unsigned char | - | 1.000000 | 0.000000 | LSU_stAdapActv_0 | Release status for adaptation 0 | |
LSU_stAdapActv_1 | 0x0A4D | STAT_LSU_stAdapActv_1_WERT | unsigned char | - | 1.000000 | 0.000000 | LSU_stAdapActv_1 | Release status for adaptation 1 | |
LSU_stActv_mp | 0x0A4E | STAT_LSU_stActv_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | LSU_stActv_mp | LSU activation status information | |
LSU_tRi_0 | 0x0A4F | STAT_LSU_tRi_0_WERT | unsigned int | degC | 0.100000 | -3549.930000 | LSU_tRi_0 | LSU equivalent temperature for Ri 0 | |
LSU_tRi_1 | 0x0A50 | STAT_LSU_tRi_1_WERT | unsigned int | degC | 0.100000 | -3549.930000 | LSU_tRi_1 | LSU equivalent temperature for Ri 1 | |
LSU_stErr_0 | 0x0A51 | STAT_LSU_stErr_0_WERT | unsigned int | - | 1.000000 | 0.000000 | LSU_stErr_0 | Error status LSU 0 | |
LSU_stErr_1 | 0x0A52 | STAT_LSU_stErr_1_WERT | unsigned int | - | 1.000000 | 0.000000 | LSU_stErr_1 | Error status LSU 1 | |
Oil_tSwmp | 0x0A8C | STAT_Oil_tSwmp_WERT | unsigned int | degC | 0.010000 | -100.000000 | Oil_tSwmp | Oil temperature | |
Oil_stPSwmp | 0x0A8D | STAT_Oil_stPSwmp_WERT | unsigned char | - | 1.000000 | 0.000000 | Oil_stPSwmp | Status of oil pressure | |
Oil_stPSwmpPlaus_mp | 0x0A8E | STAT_Oil_stPSwmpPlaus_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | Oil_stPSwmpPlaus_mp | Status of the plausibility check of the oil pressure switch | |
Oil_pPSwmp | 0x0A8F | STAT_Oil_pPSwmp_WERT | unsigned int | hPa | 1.000000 | 0.000000 | Oil_pPSwmp | Oil pressure sensor signal | |
Oil_uRawPSwmp | 0x0A90 | STAT_Oil_uRawPSwmp_WERT | unsigned int | mV | 0.200000 | 0.000000 | Oil_uRawPSwmp | ADC sensor value of the oil pressure sensor | |
ISOED | 0x0ABE | STAT_OELDRUCKSCHALTER_EIN_WERT | unsigned int | - | 1.000000 | 0.000000 | OilPLmp_st | Digital output to the oil pressure switch after diagnosis | |
OxiCat_facHCCnvRat | 0x0AD2 | STAT_OxiCat_facHCCnvRat_WERT | unsigned int | - | 0.000122 | 0.000000 | OxiCat_facHCCnvRat | HC conversion rate | |
IZBST | 0x0AF0 | STAT_BETRIEBSSTUNDENZAEHLER_WERT | unsigned long | s | 1.000000 | 0.000000 | EngDa_tiEngOn | Operating hours counter | |
ITMOT | 0x0AF1 | STAT_MOTORTEMPERATUR_WERT | unsigned int | degC | 0.100000 | -273.140000 | EngDa_tEng | Engine temperature | |
EngDa_tFld_0 | 0x0AF2 | STAT_EngDa_tFld0_WERT | unsigned int | degC | 0.100000 | 0.000000 | EngDa_tFld_0 | Engine temperature field 0 | |
EngDa_tFld_1 | 0x0AF3 | STAT_EngDa_tFld1_WERT | unsigned int | degC | 0.100000 | 0.000000 | EngDa_tFld_1 | Engine temperature field 1 | |
EngDa_tFld_2 | 0x0AF4 | STAT_EngDa_tFld2_WERT | unsigned int | degC | 0.100000 | 0.000000 | EngDa_tFld_2 | Engine temperature field 2 | |
EngDa_tFld_3 | 0x0AF5 | STAT_EngDa_tFld3_WERT | unsigned int | degC | 0.100000 | 0.000000 | EngDa_tFld_3 | Engine temperature field 3 | |
EngDa_tiEngOff | 0x0AF7 | STAT_EngDa_tiEngOff_WERT | unsigned long | s | 1.000000 | 0.000000 | EngDa_tiEngOff | Current engine stop time | |
EngDa_ctrSecLst | 0x0AF9 | STAT_EngDa_ctrSecLst_WERT | unsigned long | s | 1.000000 | 0.000000 | EngDa_ctrSecLst | Relative time stored as a time stamp by the CAN Com_ctrSec when the engine is switched off. | |
EngDa_stEngOffRst_mp | 0x0AFA | STAT_EngDa_stEngOffRst_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | EngDa_stEngOffRst_mp | Status of the reset of the engine off time if a correct calculation can no longer be guaranteed (0 if error-free) | |
EngDa_ctrMonEngOff_mp | 0x0AFC | STAT_EngDa_ctrMonEngOff_mp_WERT | unsigned long | s | 1.000000 | 0.000000 | EngDa_ctrMonEngOff_mp | Difference time of the real time of the CAN Com_ctrSec related to the last initialisation | |
EngDa_tiMonEngOff_mp | 0x0AFD | STAT_EngDa_tiMonEngOff_mp_WERT | unsigned long | s | 0.010000 | 0.000000 | EngDa_tiMonEngOff_mp | Value of the SW timer for checking the correct counting up of the real time of the CAN Com_ctrSec. | |
EngDa_tiAftRunMon | 0x0AFE | STAT_EngDa_tiAftRunMon_WERT | unsigned long | s | 1.000000 | 0.000000 | EngDa_tiAftRunMon | Engine stop time of the last drive cycle | |
EngDa_tiMonEngOffDiffReal | 0x0AFF | STAT_EngDa_tiMonEngOffDiffReal_WERT | unsigned long | s | 1.000000 | 0.000000 | EngDa_tiMonEngOffDiffReal | Real difference time of AF timer and relative timer | |
GlbDa_lTotDst | 0x0B04 | STAT_GlbDa_lTotDst_WERT | unsigned long | m | 1.000000 | 0.000000 | GlbDa_lTotDst | Total distance travelled since first start-up | |
EngStA_stPs | 0x0B18 | STAT_EngStA_stPs_WERT | unsigned char | - | 1.000000 | 0.000000 | EngStA_stPs | Status of the power stage output for MSA | |
ThrVlv_uRaw | 0x0B1C | STAT_ThrVlv_uRaw_WERT | unsigned int | mV | 0.228885 | -5000.000000 | ThrVlv_uRaw | Raw voltage value of the throttle position sensor | |
ThrVlv_rSens | 0x0B1F | STAT_ThrVlv_rSens_WERT | unsigned int | % | 0.001526 | 0.000000 | ThrVlv_rSens | Throttle - actual position from sensor curve | |
IADRK | 0x0B22 | STAT_DROSSELKLAPPENSTELLER_ANSTEUERUNG_WERT | unsigned int | % | 0.001526 | 0.000000 | ThrVlv_rPs | Throttle - output duty cycle | |
ThrVlv_rAct | 0x0B24 | STAT_ThrVlv_rAct_WERT | unsigned int | % | 0.010000 | 0.000000 | ThrVlv_rAct | Throttle valve - actual position corrected | |
StbIntv_trqDCSDes | 0x0B25 | STAT_StbIntv_trqDCSDes_WERT | unsigned long | Nm | 0.100000 | 0.000000 | StbIntv_trqDCSDes | MSR engagement torque (wheel torque) | |
MoFDCS_stDem | 0x0B26 | STAT_MoFDCS_stDem_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFDCS_stDem | Status info of the MSR intervention monitoring | |
MoFDCS_stErr | 0x0B27 | STAT_MoFDCS_stErr_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFDCS_stErr | Status - Error redundant DSC intervention | |
ThrVlv_r | 0x0B28 | STAT_ThrVlv_r_WERT | unsigned int | % | 0.001526 | 0.000000 | ThrVlv_r | Throttle valve - target duty cycle | |
ThrVlv_stMon | 0x0B29 | STAT_ThrVlv_stMon_WERT | unsigned int | - | 1.000000 | 0.000000 | ThrVlv_stMon | Throttle valve system monitoring status | |
ThrVlv_rDesVal | 0x0B2A | STAT_ThrVlv_rDesVal_WERT | unsigned int | % | 0.003052 | -100.000000 | ThrVlv_rDesVal | Throttle - set position | |
IVKMH | 0x0B40 | STAT_GESCHWINDIGKEIT_WERT | unsigned int | km/h | 0.004578 | 0.000000 | VehV_v | Vehicle speed | |
IAFZG | 0x0B41 | STAT_FAHRZEUGBESCHLEUNIGUNG_WERT | unsigned int | m/s^2 | 0.001000 | -32.767000 | VehV_a | Vehicle acceleration | |
IMARD | 0x0B54 | STAT_MOMENTFORDERUNG_ARD_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | ASDdc_trq | ASD disturbance controller output torque | |
ASDdc_stSelSt_mp | 0x0B55 | STAT_ASDdc_stSelSt_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | ASDdc_stSelSt_mp | Selected primary state (decimal coded) | |
ASDrf_stSelSt_mp | 0x0B86 | STAT_ASDrf_stSelSt_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | ASDrf_stSelSt_mp | Selected primary state (decimal coded) | |
PCBS_lDistanceOut | 0x0BA4 | STAT_PCBS_lDistanceOut_WERT | unsigned int | km | 10.000000 | 0.000000 | PCBS_lDistanceOut | Remaining running distance for particle filter (calculated by CBS) | |
PCBS_lSumDPFChng | 0x0BA5 | STAT_PCBS_lSumDPFChng_WERT | unsigned long | km | 10.000000 | 0.000000 | PCBS_lSumDPFChng | Distance travelled since last particulate filter change (calculated by CBS) | |
EGRVlv_uRaw | 0x0BB1 | STAT_EGRVlv_uRaw_WERT | unsigned int | mV | 0.228885 | -5000.000000 | EGRVlv_uRaw | Raw voltage value of EGR position sensor | |
EGRVlv_rSens | 0x0BB4 | STAT_EGRVlv_rSens_WERT | unsigned int | % | 0.001526 | 0.000000 | EGRVlv_rSens | EGR valve - actual position from sensor characteristic curve | |
EGRVlv_rEGR | 0x0BB7 | STAT_EGRVlv_rEGR_WERT | unsigned int | % | 0.001526 | 0.000000 | EGRVlv_rEGR | EGR valve control value | |
EGRVlv_rAct | 0x0BB8 | STAT_EGRVlv_rAct_WERT | unsigned int | % | 0.012207 | 0.000000 | EGRVlv_rAct | Duty cycle - exhaust gas recirculation control valve | |
IAAGR | 0x0BB9 | STAT_ABGASRUECKFUEHRSTELLER_ANSTEUERUNG_WERT | unsigned int | % | 0.001526 | 0.000000 | EGRVlv_rPs | EGR valve - output duty cycle | |
EGRVlv_r | 0x0BBB | STAT_EGRVlv_r_WERT | unsigned int | % | 0.003052 | 0.000000 | EGRVlv_r | Target duty cycle - exhaust gas recirculation control valve | |
EGRVlv_stMon | 0x0BBC | STAT_EGRVlv_stMon_WERT | unsigned int | - | 1.000000 | 0.000000 | EGRVlv_stMon | Status of the system monitoring of the EGR valve | |
EGRVlv_rOfsLrnFrst | 0x0BBD | STAT_EGRVlv_rOfsLrnFrst_WERT | unsigned int | % | 0.003052 | -100.000000 | EGRVlv_rOfsLrnFrst | First learned offset value | |
EGRVlv_rOfsLrnLst | 0x0BBE | STAT_EGRVlv_rOfsLrnLst_WERT | unsigned int | % | 0.003052 | -100.000000 | EGRVlv_rOfsLrnLst | Last learned offset value | |
EGRVlv_rOfsLrnNew | 0x0BBF | STAT_EGRVlv_rOfsLrnNew_WERT | unsigned int | % | 0.003052 | -100.000000 | EGRVlv_rOfsLrnNew | Learned offset value in the current driving cycle | |
EGRVlv_rDesEGR | 0x0BC0 | STAT_EGRVlv_rDesEGR_WERT | unsigned int | % | 0.003052 | -100.000000 | EGRVlv_rDesEGR | EGR valve - set position | |
EGRVlvLP_rPs | 0x0BC2 | STAT_EGRVlvLP_rPs_WERT | unsigned int | % | 0.001526 | 0.000000 | EGRVlvLP_rPs | Low pressure EGR valve - output duty cycle | |
EGRVlvLP_r | 0x0BC4 | STAT_EGRVlvLP_r_WERT | unsigned int | % | 0.001526 | 0.000000 | EGRVlvLP_r | Low-pressure EGR valve â€" output duty cycle ratio | |
EGRVlvLP_rAct | 0x0BC5 | STAT_EGRVlvLP_rAct_WERT | unsigned int | % | 0.001526 | 0.000000 | EGRVlvLP_rAct | Low pressure EGR valve - actual position corrected | |
EGRVlvLP_uRaw | 0x0BC7 | STAT_EGRVlvLP_uRaw_WERT | unsigned int | mV | 0.076295 | 0.000000 | EGRVlvLP_uRaw | Raw voltage value - low pressure exhaust gas recirculation control valve | |
EGRVlvLP_stMon | 0x0BC8 | STAT_EGRVlvLP_stMon_WERT | unsigned int | - | 1.000000 | 0.000000 | EGRVlvLP_stMon | Status of the system monitoring of the LP EGR valve | |
EGRVlvLP_rOfsLrnFrst | 0x0BC9 | STAT_EGRVlvLP_rOfsLrnFrst_WERT | unsigned int | % | 0.003052 | -100.000000 | EGRVlvLP_rOfsLrnFrst | First learned offset value | |
EGRVlvLP_rOfsLrnLst | 0x0BCA | STAT_EGRVlvLP_rOfsLrnLst_WERT | unsigned int | % | 0.003052 | -100.000000 | EGRVlvLP_rOfsLrnLst | Last learned offset value | |
EGRVlvLP_rOfsLrnNew | 0x0BCB | STAT_EGRVlvLP_rOfsLrnNew_WERT | unsigned int | % | 0.003052 | -100.000000 | EGRVlvLP_rOfsLrnNew | Learned offset value in existing drive cycle | |
EGRVlvLP_rSens | 0x0BCD | STAT_EGRVlvLP_rSens_WERT | unsigned int | % | 0.001526 | 0.000000 | EGRVlvLP_rSens | Low pressure EGR - actuator position | |
EGRClgLP_tSens_mp | 0x0BD6 | STAT_EGRClgLP_tSens_mp_WERT | unsigned int | degC | 0.016022 | -50.000000 | EGRClgLP_tSens_mp | Temperature of the sensor | |
EGRClg_tSens_mp | 0x0BD7 | STAT_EGRClg_tSens_mp_WERT | unsigned int | degC | 0.016022 | -50.000000 | EGRClg_tSens_mp | Temperature of the sensor | |
TrbCh_r | 0x0BEA | STAT_TrbCh_r_WERT | unsigned int | % | 0.003052 | 0.000000 | TrbCh_r | Boost pressure regulator - target duty cycle | |
IALDS | 0x0BEB | STAT_LADEDRUCKSTELLER_ANSTEUERUNG_WERT | unsigned int | % | 0.001526 | 0.000000 | TrbCh_rPs | Boost pressure controller - output duty cycle | |
TrbCh_rRaw | 0x0BEC | STAT_TrbCh_rRaw_WERT | unsigned int | % | 0.010000 | 0.000000 | TrbCh_rRaw | Boost pressure regulator - actual position raw value | |
TrbCh_rAct | 0x0BF0 | STAT_TrbCh_rAct_WERT | unsigned int | % | 0.001526 | 0.000000 | TrbCh_rAct | Boost pressure controller - actual position corrected | |
TrbCh_rSens | 0x0BF2 | STAT_TrbCh_rSens_WERT | unsigned int | % | 0.001526 | 0.000000 | TrbCh_rSens | Boost pressure controller - actual position from sensor curve | |
TrbChVNT2_rPs | 0x0BF5 | STAT_TrbChVNT2_rPs_WERT | unsigned int | % | 0.001526 | 0.000000 | TrbChVNT2_rPs | High pressure VNT actuator 2 - output duty cycle | |
CCiByVlv_stPs | 0x0BF7 | STAT_CCiByVlv_stPs_WERT | unsigned char | - | 1.000000 | 0.000000 | CCiByVlv_stPs | Status of compressor bypass valve (final stage) | |
DCByVlv_stPs | 0x0BF8 | STAT_DCByVlv_stPs_WERT | unsigned char | - | 1.000000 | 0.000000 | DCByVlv_stPs | Status of compressor bypass valve of LP stage (final stage) | |
TrbCh_rDes | 0x0BF9 | STAT_TrbCh_rDes_WERT | unsigned int | % | 0.010000 | 0.000000 | TrbCh_rDes | Required turbocharger duty cycle | |
TrbCh_stMon | 0x0BFB | STAT_TrbCh_stMon_WERT | unsigned int | - | 1.000000 | 0.000000 | TrbCh_stMon | Boost pressure controller system monitoring status | |
TrbCh_uRaw | 0x0BFC | STAT_TrbCh_uRaw_WERT | unsigned int | mV | 0.228885 | -5000.000000 | TrbCh_uRaw | Raw voltage value of the ATL position sensor | |
TrbCh_rGovDvt | 0x0BFE | STAT_TrbCh_rGovDvt_WERT | unsigned int | % | 0.006104 | -200.000000 | TrbCh_rGovDvt | Control deviation of the ATL-seller | |
TrbChVNT_uRaw | 0x0C00 | STAT_TrbChVNT_uRaw_WERT | unsigned int | mV | 0.228885 | -5000.000000 | TrbChVNT_uRaw | Raw voltage value of the VNT position sensor | |
TrbChVNT_r | 0x0C02 | STAT_TrbChVNT_r_WERT | unsigned int | % | 0.012207 | 0.000000 | TrbChVNT_r | High pressure VNT positioner - target duty cycle | |
TrbChVNT_rDes | 0x0C03 | STAT_TrbChVNT_rDes_WERT | unsigned int | % | 0.010000 | 0.000000 | TrbChVNT_rDes | required turbocharger duty cycle (VNT) | |
TrbChVNT_rAct | 0x0C05 | STAT_TrbChVNT_rAct_WERT | unsigned int | % | 0.010000 | 0.000000 | TrbChVNT_rAct | High pressure VNT actuator - actual position corrected | |
TrbChVNT_stMon | 0x0C07 | STAT_TrbChVNT_stMon_WERT | unsigned int | - | 1.000000 | 0.000000 | TrbChVNT_stMon | High pressure VNT actuator system monitoring - status | |
TrbChLP_r | 0x0C08 | STAT_TrbChLP_r_WERT | unsigned int | % | 0.012207 | 0.000000 | TrbChLP_r | Low pressure boost pressure regulator - target duty cycle | |
TrbChLP_rPs | 0x0C09 | STAT_TrbChLP_rPs_WERT | unsigned int | % | 0.010000 | 0.000000 | TrbChLP_rPs | Low pressure boost pressure regulator - output duty cycle | |
TrbChVNT_rPs | 0x0C0D | STAT_TrbChVNT_rPs_WERT | unsigned char | % | 0.392157 | 0.000000 | TrbChVNT_rPs | High pressure VNT actuator - output duty cycle (1 byte) | |
TrbChVNT_rRaw | 0x0C0E | STAT_TrbChVNT_rRaw_WERT | unsigned char | % | 0.392157 | 0.000000 | TrbChVNT_rRaw | High pressure VNT actuator - actual position raw value (1 byte) | |
TrbChVNT_rSens | 0x0C0F | STAT_TrbChVNT_rSens_WERT | unsigned char | % | 0.392157 | 0.000000 | TrbChVNT_rSens | High-pressure VNT actuator - actual position from sensor characteristic (1 byte) | |
TrbChVNT_stActr | 0x0C10 | STAT_TrbChVNT_stActr_WERT | unsigned int | - | 1.000000 | 0.000000 | TrbChVNT_stActr | High-pressure VNT actuator state machine - status | |
TrbChVNT2_r | 0x0C12 | STAT_TrbChVNT2_r_WERT | unsigned int | % | 0.012207 | 0.000000 | TrbChVNT2_r | Output duty cycle of the output stage HD-VNT2 actuator (switchable) | |
TrbChVNT2_rActNrm | 0x0C14 | STAT_TrbChVNT2_rActNrm_WERT | unsigned int | % | 0.010000 | 0.000000 | TrbChVNT2_rActNrm | Current duty cycle of the output stage HD-VNT2 actuator (switchable) | |
TrbChVNT2_rDesVal | 0x0C16 | STAT_TrbChVNT2_rDesVal_WERT | unsigned int | % | 0.010000 | 0.000000 | TrbChVNT2_rDesVal | requested duty cycle of the output stage HD-VNT2 controller (switchable) | |
TrbChVNT2_rSens | 0x0C18 | STAT_TrbChVNT2_rSens_WERT | unsigned int | % | 0.010000 | 0.000000 | TrbChVNT2_rSens | Actual duty cycle of the output stage HD-VNT2 actuator (switchable) | |
TrbChVNT2_stActr | 0x0C1A | STAT_TrbChVNT2_stActr_WERT | unsigned int | - | 1.000000 | 0.000000 | TrbChVNT2_stActr | Status of the switchable high pressure stage (HD-VNT2) | |
IPUMG | 0x0C1C | STAT_UMGEBUNGSDRUCK_WERT | unsigned int | hPa | 0.030518 | 0.000000 | EnvP_p | Ambient pressure | |
IUUMG | 0x0C1D | STAT_UMGEBUNGSDRUCK_SPANNUNG_WERT | unsigned int | mV | 0.076295 | 0.000000 | EnvP_uRaw | Ambient pressure - raw voltage value from sensor | |
CCiByVlv_st | 0x0C30 | STAT_CCiByVlv_st_WERT | unsigned char | - | 1.000000 | 0.000000 | CCiByVlv_st | Status of compressor bypass valve | |
DCByVlv_st | 0x0C31 | STAT_DCByVlv_st_WERT | unsigned char | - | 1.000000 | 0.000000 | DCByVlv_st | Status from compressor bypass valve of LP stage (requested) | |
Layer_nDesTrbChgWP | 0x0C32 | STAT_Layer_nDesTrbChgWP_WERT | unsigned char | - | 1.000000 | 0.000000 | Layer_nDesTrbChgWP | Status - water pump control in LLK circuit (LIN) | |
CCACLpDsT_t | 0x0C33 | STAT_CCACLpDsT_t_WERT | unsigned int | degC | 0.100000 | -273.140000 | CCACLpDsT_t | Coolant temperature for charge air cooler (filtered) | |
CCACLpDsT_tSens | 0x0C35 | STAT_CCACLpDsT_tSens_WERT | unsigned int | degC | 0.100000 | -273.140000 | CCACLpDsT_tSens | Coolant temperature for charge air cooler (raw sensor value) | |
CCACLpDsT_uRaw | 0x0C37 | STAT_CCACLpDsT_uRaw_WERT | unsigned int | mV | 0.200000 | 0.000000 | CCACLpDsT_uRaw | Sensor raw voltage - coolant temperature for charge air cooler | |
ETCtl_tDvtDwnOLopThres_mp | 0x0C4E | STAT_ETCtl_tDvtDwnOLopThres_mp_WERT | unsigned int | K | 0.100000 | 0.000000 | ETCtl_tDvtDwnOLopThres_mp | Temperature threshold value for monitoring the maximum controller intervention | |
ETCtl_tDvtOutr | 0x0C4F | STAT_ETCtl_tDvtOutr_WERT | unsigned int | K | 0.016022 | -50.000000 | ETCtl_tDvtOutr | Control deviation of the outer control loop | |
ETCtl_tDvtUpOLopThres_mp | 0x0C50 | STAT_ETCtl_tDvtUpOLopThres_mp_WERT | unsigned int | K | 0.100000 | 0.000000 | ETCtl_tDvtUpOLopThres_mp | Temperature threshold for monitoring the minimum controller intervention | |
ETCtl_tOutrDes | 0x0C51 | STAT_ETCtl_tOutrDes_WERT | unsigned int | degC | 0.100000 | -273.140000 | ETCtl_tOutrDes | Temperature setpoint of the outer control loop | |
ETCtl_tiEOMOLopOn_mp | 0x0C52 | STAT_ETCtl_tiEOMOLopOn_mp_WERT | unsigned long | s | 0.000015 | 0.000000 | ETCtl_tiEOMOLopOn_mp | Activation time of the outer control loop | |
ASMod_dmIndAirRef | 0x0C80 | STAT_ASMod_dmIndAirRef_WERT | unsigned int | kg/h | 0.048829 | -1600.000000 | ASMod_dmIndAirRef | Reference gas mass flow into the engine | |
ASMod_pPFltSimDs | 0x0C81 | STAT_ASMod_pPFltSimDs_WERT | unsigned int | hPa | 1.000000 | 0.000000 | ASMod_pPFltSimDs | Simulated pressure after particulate filter | |
ASMod_dvolPFltEG | 0x0C83 | STAT_ASMod_dvolPFltEG_WERT | unsigned long | m^3/h | 0.100000 | 0.000000 | ASMod_dvolPFltEG | Calculated exhaust gas mass flow in the particulate filter | |
ASMod_mAirPerCylCor | 0x0C85 | STAT_ASMod_mAirPerCylCor_WERT | unsigned int | mg/Hub | 0.100000 | 0.000000 | ASMod_mAirPerCylCor | dynamically corrected air mass per cylinder before the mixing point in the inlet manifold | |
ASMod_nTrbCh | 0x0C86 | STAT_ASMod_nTrbCh_WERT | unsigned int | rpm | 3.814755 | 0.000000 | ASMod_nTrbCh | actual speed of the turbocharger (from AsMod) | |
ASMod_tCmprDs | 0x0C87 | STAT_ASMod_tCmprDs_WERT | unsigned int | degC | 0.009155 | -100.000000 | ASMod_tCmprDs | Air temperature before compressor (from AsMod) | |
ASMod_dmEGRDs | 0x0C89 | STAT_ASMod_dmEGRDs_WERT | unsigned int | kg/h | 0.009155 | -100.000000 | ASMod_dmEGRDs | EGR mass flow | |
ASMod_dmIntMnfUs | 0x0C8B | STAT_ASMod_dmIntMnfUs_WERT | unsigned int | kg/h | 0.076295 | 0.000000 | ASMod_dmIntMnfUs | Gas mass flow before EGR injection (from AsMod) | |
ASMod_dmIntMnfDs | 0x0C8D | STAT_ASMod_dmIntMnfDs_WERT | unsigned int | kg/h | 0.076295 | 0.000000 | ASMod_dmIntMnfDs | Charge mass flow (from AsMod) | |
ASMod_tIntMnfUs | 0x0C8F | STAT_ASMod_tIntMnfUs_WERT | unsigned int | degC | 0.009155 | -100.000000 | ASMod_tIntMnfUs | Temperature before inlet manifold (T21 from AsMod) | |
ASMod_tIntMnfDs | 0x0C91 | STAT_ASMod_tIntMnfDs_WERT | unsigned int | degC | 0.009155 | -100.000000 | ASMod_tIntMnfDs | Temperature before inlet manifold (T22 from AsMod) | |
ASMod_dmEGRLPDs | 0x0C93 | STAT_ASMod_dmEGRLPDs_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | ASMod_dmEGRLPDs | recirculated exhaust gas mass flow according to low pressure EGR | |
ASMod_pTrbnUs | 0x0C94 | STAT_ASMod_pTrbnUs_WERT | unsigned int | hPa | 1.000000 | 0.000000 | ASMod_pTrbnUs | Exhaust gas pressure before turbine | |
ASMod_facEGRClgDvtHi_mp | 0x0C95 | STAT_ASMod_facEGRClgDvtHi_mp_WERT | unsigned int | - | 0.000122 | 0.000000 | ASMod_facEGRClgDvtHi_mp | Act. Slope of the positive adaptation line at HDAGR cooler | |
ASMod_facEGRClgDvtLo_mp | 0x0C96 | STAT_ASMod_facEGRClgDvtLo_mp_WERT | unsigned int | - | 0.000122 | 0.000000 | ASMod_facEGRClgDvtLo_mp | Act. Slope of the negative adaptation line at the HDAGR cooler | |
ASMod_facEGRLPClgDvtHi_mp | 0x0C97 | STAT_ASMod_facEGRLPClgDvtHi_mp_WERT | unsigned int | - | 0.000122 | 0.000000 | ASMod_facEGRLPClgDvtHi_mp | Current Slope of the positive adaptation line at NDAGR cooler | |
ASMod_facEGRLPClgDvtLo_mp | 0x0C98 | STAT_ASMod_facEGRLPClgDvtLo_mp_WERT | unsigned int | - | 0.000122 | 0.000000 | ASMod_facEGRLPClgDvtLo_mp | Act. Slope of the negative adaptation line at NDAGR cooler | |
ASMod_facEtaEGRClgObsvCor | 0x0C99 | STAT_ASMod_facEtaEGRClgObsvCor_WERT | unsigned int | - | 0.000122 | 0.000000 | ASMod_facEtaEGRClgObsvCor | Correction factor from HDAGR cooler adaptation | |
ASMod_dmIntMnfDsRef | 0x0C9A | STAT_ASMod_dmIntMnfDsRef_WERT | unsigned int | kg/h | 0.076295 | 0.000000 | ASMod_dmIntMnfDsRef | Reference of gas mass flow after inlet manifold | |
ASMod_pHPTrbnUs | 0x0C9C | STAT_ASMod_pHPTrbnUs_WERT | unsigned int | hPa | 0.038148 | 500.000000 | ASMod_pHPTrbnUs | Pressure before turbine of high-pressure stage | |
ASMod_facEGRClgHiDev_mp | 0x0C9D | STAT_ASMod_facEGRClgHiDev_mp_WERT | unsigned int | - | 0.003052 | -100.000000 | ASMod_facEGRClgHiDev_mp | Reference slope - actual slope of the positive adaptation line to HDAGR cooler | |
ASMod_facEGRClgLoDev_mp | 0x0C9E | STAT_ASMod_facEGRClgLoDev_mp_WERT | unsigned int | - | 0.003052 | -100.000000 | ASMod_facEGRClgLoDev_mp | Reference slope - actual slope of the negative adaptation line at the HDAGR cooler | |
ASMod_facEGRLPClgLoDev_mp | 0x0C9F | STAT_ASMod_facEGRLPClgLoDev_mp_WERT | unsigned int | - | 0.003052 | -100.000000 | ASMod_facEGRLPClgLoDev_mp | Reference slope - actual slope of the negative adaptation line at NDAGR cooler | |
ASMod_facEGRLPClgHiDev_mp | 0x0CA0 | STAT_ASMod_facEGRLPClgHiDev_mp_WERT | unsigned int | - | 0.003052 | -100.000000 | ASMod_facEGRLPClgHiDev_mp | Reference slope - actual slope of the positive adaptation line at LPAGR cooler | |
ASMod_rEGRHP | 0x0CA1 | STAT_ASMod_rEGRHP_WERT | unsigned int | - | 0.010000 | 0.000000 | ASMod_rEGRHP | Exhaust gas recirculation rate via the HD-AGR valve into the engine | |
ASMod_tEGRDsSim_mp | 0x0CA2 | STAT_ASMod_tEGRDsSim_mp_WERT | unsigned int | degC | 0.100000 | -273.140000 | ASMod_tEGRDsSim_mp | Model temperature after HDAGR cooler | |
ASMod_tEGRLPDsSim_mp | 0x0CA3 | STAT_ASMod_tEGRLPDsSim_mp_WERT | unsigned int | degC | 0.010000 | -327.680000 | ASMod_tEGRLPDsSim_mp | Model temperature after NDAGR cooler | |
ASMod_tExhMnfLP | 0x0CA4 | STAT_ASMod_tExhMnfLP_WERT | unsigned int | degC | 0.100000 | -273.140000 | ASMod_tExhMnfLP | Model temperature at NDAGR withdrawal | |
ASMod_tPFltSurfSim | 0x0CA5 | STAT_ASMod_tPFltSurfSim_WERT | unsigned int | degC | 0.100000 | -273.140000 | ASMod_tPFltSurfSim | Simulated surface temperature particle filter | |
ASMod_rEGR | 0x0CA6 | STAT_ASMod_rEGR_WERT | unsigned int | - | 0.010000 | 0.000000 | ASMod_rEGR | EGR rate - actual value | |
AirMod_facDiagEgrCoolrObsvr1 | 0x0CA7 | STAT_AirMod_facDiagEgrCoolrObsvr1_WERT | unsigned char | - | 1.000000 | 0.000000 | AirMod_facDiagEgrCoolrObsvr1 | Index 1 for allocation of EGR cooler adaptation | |
AirMod_facDiagEgrCoolrObsvr2 | 0x0CA8 | STAT_AirMod_facDiagEgrCoolrObsvr2_WERT | unsigned char | - | 1.000000 | 0.000000 | AirMod_facDiagEgrCoolrObsvr2 | Index 2 for allocation of EGR cooler adaptation | |
ASMod_facEGRClgDvtHi1_mp | 0x0CA9 | STAT_ASMod_facEGRClgDvtHi1_mp_WERT | unsigned int | - | 0.003000 | -96.600000 | ASMod_facEGRClgDvtHi1_mp | act. Slope of the positive adaptation line to EGR cooler 1 | |
ASMod_facEGRClgDvtHi2_mp | 0x0CAA | STAT_ASMod_facEGRClgDvtHi2_mp_WERT | unsigned int | - | 0.003000 | -96.600000 | ASMod_facEGRClgDvtHi2_mp | Act. Slope of the positive adaptation line to EGR cooler 2 | |
ASMod_facEGRClgDvtLo1_mp | 0x0CAB | STAT_ASMod_facEGRClgDvtLo1_mp_WERT | unsigned int | - | 0.003000 | -96.600000 | ASMod_facEGRClgDvtLo1_mp | Act. Slope of the negative adaptation line at EGR cooler 1 | |
ASMod_facEGRClgDvtLo2_mp | 0x0CAC | STAT_ASMod_facEGRClgDvtLo2_mp_WERT | unsigned int | - | 0.003000 | -96.600000 | ASMod_facEGRClgDvtLo2_mp | Act. Slope of the negative adaptation line at EGR cooler 2 | |
AirMod_facEtaEgrCoolrObsvr1 | 0x0CAD | STAT_AirMod_facEtaEgrCoolrObsvr1_WERT | unsigned int | - | 0.003000 | -96.600000 | AirMod_facEtaEgrCoolrObsvr1 | Correction factor from EGR cooler adaptation 1 | |
AirMod_facEtaEgrCoolrObsvr2 | 0x0CAE | STAT_AirMod_facEtaEgrCoolrObsvr2_WERT | unsigned int | - | 0.003000 | -96.600000 | AirMod_facEtaEgrCoolrObsvr2 | Correction factor from EGR cooler adaptation 2 | |
ASMod_facEGRClgHiDev1_mp | 0x0CAF | STAT_ASMod_facEGRClgHiDev1_mp_WERT | unsigned int | - | 0.003000 | -96.600000 | ASMod_facEGRClgHiDev1_mp | Reference slope - actual slope of the positive adaptation line at EGR cooler 1 | |
ASMod_facEGRClgHiDev2_mp | 0x0CB0 | STAT_ASMod_facEGRClgHiDev2_mp_WERT | unsigned int | - | 0.003000 | -96.600000 | ASMod_facEGRClgHiDev2_mp | Reference slope - actual slope of the positive adaptation line at EGR cooler 2 | |
ASMod_facEGRClgLoDev1_mp | 0x0CB1 | STAT_ASMod_facEGRClgLoDev1_mp_WERT | unsigned int | - | 0.003000 | -96.600000 | ASMod_facEGRClgLoDev1_mp | Reference slope - actual slope of the negative adaptation line at EGR cooler 1 | |
ASMod_facEGRClgLoDev2_mp | 0x0CB2 | STAT_ASMod_facEGRClgLoDev2_mp_WERT | unsigned int | - | 0.003000 | -96.600000 | ASMod_facEGRClgLoDev2_mp | Reference slope - actual slope of the negative adaptation line at EGR cooler 2 | |
AirMod_tEGRDsSim | 0x0CB3 | STAT_AirMod_tEGRDsSim_WERT | unsigned int | degC | 0.010000 | -327.680000 | AirMod_tEGRDsSim | Model temperature according to HDAGR cooler | |
AirMod_tEGRLPDsSim | 0x0CB4 | STAT_AirMod_tEGRLPDsSim_WERT | unsigned int | degC | 0.010000 | -327.680000 | AirMod_tEGRLPDsSim | Model temperature after LP EGR cooler | |
CAClg_etaFlt_mp | 0x0CB5 | STAT_CAClg_etaFlt_mp_WERT | unsigned char | - | 0.007843 | -1.000000 | CAClg_etaFlt_mp | Charge air cooler efficiency (filtered) | |
EMDmp_rPs_0 | 0x0CE5 | STAT_EMDmp_rPs_WERT | unsigned int | % | 0.010000 | 0.000000 | EMDmp_rPs_0 | Motor vibration damper - output duty cycle | |
CByVlv_st | 0x0D48 | STAT_CByVlv_st_WERT | unsigned char | - | 1.000000 | 0.000000 | CByVlv_st | High pressure compressor bypass - status | |
CByVlv_stPs | 0x0D49 | STAT_CByVlv_stPs_WERT | unsigned char | - | 1.000000 | 0.000000 | CByVlv_stPs | Compressor bypass - digital output to controller | |
RadSht_stLogic_mp | 0x0D66 | STAT_RadSht_stLogic_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | RadSht_stLogic_mp | Supply air damper logic status | |
Shtr_rPs | 0x0D7B | STAT_Shtr_rPs_WERT | unsigned int | % | 0.010000 | 0.000000 | Shtr_rPs | Active cool air damper - output duty cycle | |
Shtr_st | 0x0D7D | STAT_Shtr_st_WERT | unsigned char | - | 1.000000 | 0.000000 | Shtr_st | Request status for digital output | |
StSys_nStrtCutOut_mp | 0x0D8E | STAT_StSys_nStrtCutOut_mp_WERT | unsigned int | rpm | 0.091554 | 0.000000 | StSys_nStrtCutOut_mp | Start ejector speed - dependent on coolant temperature and air pressure | |
StSys_nStrtCutOutMSA_mp | 0x0D8F | STAT_StSys_nStrtCutOutMSA_mp_WERT | unsigned int | rpm | 0.091554 | 0.000000 | StSys_nStrtCutOutMSA_mp | Start ejector speed - dependent on coolant temperature and air pressure | |
StSys_trqStrt | 0x0D90 | STAT_StSys_trqStrt_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | StSys_trqStrt | Inner torque Start value | |
SpdGov_trqSet | 0x0DAC | STAT_SpdGov_trqSet_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | SpdGov_trqSet | Target torque of the SpdGov on the fuel path | |
CrCtl_stShOffConRvActv_mp | 0x0DDE | STAT_CrCtl_stShOffConRvActv_mp_WERT | unsigned long | - | 1.000000 | 0.000000 | CrCtl_stShOffConRvActv_mp | Cruise control current cut-off conditions (reversible) | |
CrCtl_stShOff | 0x0DDF | STAT_CrCtl_stShOff_WERT | unsigned char | - | 1.000000 | 0.000000 | CrCtl_stShOff | Cruise control cut-off conditions | |
CrCtl_aReq | 0x0DE1 | STAT_CrCtl_aReq_WERT | unsigned int | m/s^2 | 0.001000 | -32.767000 | CrCtl_aReq | Acceleration request of cruise control | |
CrCtl_vDes | 0x0DE2 | STAT_CrCtl_vDes_WERT | unsigned int | km/h | 0.010000 | 0.000000 | CrCtl_vDes | Desired speed of cruise control | |
CrCtl_st | 0x0DE3 | STAT_CrCtl_st_WERT | unsigned char | - | 1.000000 | 0.000000 | CrCtl_st | Cruise control status | |
CrC_stKey | 0x0DE4 | STAT_CrC_stKey_WERT | unsigned int | - | 1.000000 | 0.000000 | CrC_stKey | Cruise control control unit status | |
CrCUI_stBtn | 0x0DE5 | STAT_CrCUI_stBtn_WERT | unsigned int | - | 1.000000 | 0.000000 | CrCUI_stBtn | Cruise control control unit actuation status | |
Com_stCrCtlLvr | 0x0DE6 | STAT_Com_stCrCtlLvr_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_stCrCtlLvr | Cruise control control unit status | |
Com_stDrvVehMSASend | 0x0DE7 | STAT_Com_stDrvVehMSASend_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_stDrvVehMSASend | Actual status drive car MSA | |
Com_phiStWhlAg | 0x0DE9 | STAT_Com_phiStWhlAg_WERT | unsigned int | degLW | 2048.031250 | -67108864.000000 | Com_phiStWhlAg | Steering wheel angle | |
Com_stACEFan | 0x0DEB | STAT_Com_stACEFan_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_stACEFan | Fan request air conditioning | |
Com_stStgEFan | 0x0DEC | STAT_Com_stStgEFan_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_stStgEFan | Steering fan demand | |
Md_gennm | 0x0E10 | STAT_Md_gennm_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | Md_gennm | Filtered generator torque (absolute at output) | |
Dffgen | 0x0E42 | STAT_Dffgen_WERT | unsigned char | % | 0.390625 | 0.000000 | Dffgen | Generator control - derivation of signal Dffgen | |
Ptc_pwr | 0x0E74 | STAT_Ptc_pwr_WERT | unsigned char | % | 0.500000 | 0.000000 | Ptc_pwr | Maximum allowed auxiliary heater output | |
Tra_numGear | 0x0EA6 | STAT_Tra_numGear_WERT | unsigned char | - | 1.000000 | 0.000000 | Tra_numGear | Current gear | |
Tra_tOil | 0x0EA7 | STAT_Tra_tOil_WERT | unsigned char | degC | 1.000000 | -40.000000 | Tra_tOil | Transmission oil temperature | |
RWKUP | 0x0ED8 | STAT_WAKEUP_ROH_WERT | unsigned char | - | 1.000000 | 0.000000 | T15_st | Debounced value of terminal 15 | |
T50_st | 0x0ED9 | STAT_T50_st_WERT | unsigned char | - | 1.000000 | 0.000000 | T50_st | Status of terminal 50 | |
T15_stRaw | 0x0EDA | STAT_T15_stRaw_WERT | unsigned char | - | 1.000000 | 0.000000 | T15_stRaw | Raw status of terminal 15 after debouncing | |
ISKUP | 0x0F0A | STAT_KUP_EIN_WERT | unsigned char | - | 1.000000 | 0.000000 | Clth_st | Clutch status information | |
Hegn_mAirAftOvrRunB1S2 | 0x0F3C | STAT_Hegn_mAirAftOvrRunB1S2_WERT | unsigned int | g | 0.100000 | 0.000000 | Hegn_mAirAftOvrRunB1S2 | Min. integrated mass air flow (after SCR) | |
Hegn_mAirAftOvrRunB1S1 | 0x0F3D | STAT_Hegn_mAirAftOvrRunB1S1_WERT | unsigned int | g | 0.100000 | 0.000000 | Hegn_mAirAftOvrRunB1S1 | Min. integrated mass air flow (before SCR) | |
Hegn_ratNoxPresCompB1S2 | 0x0F43 | STAT_Hegn_ratNoxPresCompB1S2_WERT | unsigned int | ppm | 0.025940 | -50.000000 | Hegn_ratNoxPresCompB1S2 | Pressure-compensated NOx signal (after SCR) | |
Hegn_ratNoxPresCompB1S1 | 0x0F44 | STAT_Hegn_ratNoxPresCompB1S1_WERT | unsigned int | ppm | 0.025940 | -50.000000 | Hegn_ratNoxPresCompB1S1 | Pressure-compensated NOx signal (before SCR) | |
Hegn_ratO2LinB1S2 | 0x0F45 | STAT_Hegn_ratO2LinB1S2_WERT | unsigned int | - | 0.000100 | -3.267800 | Hegn_ratO2LinB1S2 | O2 concentration in exhaust gas (after SCR) | |
Hegn_ratO2LinB1S1 | 0x0F46 | STAT_Hegn_ratO2LinB1S1_WERT | unsigned int | - | 0.000100 | -3.267800 | Hegn_ratO2LinB1S1 | O2 concentration in exhaust gas (before SCR) | |
Hegn_stLamLeanB1S2 | 0x0F47 | STAT_Hegn_stLamLeanB1S2_WERT | unsigned char | - | 1.000000 | 0.000000 | Hegn_stLamLeanB1S2 | Status - Lambda signal from NOx sensor (after SCR) | |
Hegn_stLamLeanB1S1 | 0x0F48 | STAT_Hegn_stLamLeanB1S1_WERT | unsigned char | - | 1.000000 | 0.000000 | Hegn_stLamLeanB1S1 | Status - Lambda signal from NOx sensor (before SCR) | |
Hegn_stNoxVldB1S2 | 0x0F49 | STAT_Hegn_stNoxVldB1S2_WERT | unsigned char | - | 1.000000 | 0.000000 | Hegn_stNoxVldB1S2 | Status - Validity of NOx signal from NOx sensor (after SCR) | |
Hegn_stNoxVldB1S1 | 0x0F4A | STAT_Hegn_stNoxVldB1S1_WERT | unsigned char | - | 1.000000 | 0.000000 | Hegn_stNoxVldB1S1 | Status - validity of NOx signal from NOx sensor (before SCR) | |
Hegn_ratNoxB1S2 | 0x0F4D | STAT_Hegn_ratNoxB1S2_WERT | unsigned int | ppm | 0.032044 | -100.000000 | Hegn_ratNoxB1S2 | offset corrected signal from NOx sensor 2 (after SCR) | |
Hegn_ratNoxB1S1 | 0x0F4F | STAT_Hegn_ratNoxB1S1_WERT | unsigned int | ppm | 0.032044 | -100.000000 | Hegn_ratNoxB1S1 | offset corrected signal from NOx sensor 1 (before SCR) | |
Hegn_ratNoxOffsB1S2 | 0x0F51 | STAT_Hegn_ratNoxOffsB1S2_WERT | unsigned int | ppm | 0.032044 | -100.000000 | Hegn_ratNoxOffsB1S2 | Sensor offset due to shear calibration (NOx sensor after SCR) | |
Hegn_ratNoxOffsB1S1 | 0x0F52 | STAT_Hegn_ratNoxOffsB1S1_WERT | unsigned int | ppm | 0.032044 | -100.000000 | Hegn_ratNoxOffsB1S1 | Sensor offset due to shear calibration (NOx sensor before SCR) | |
ECBVlv_rAct | 0x0FA0 | STAT_ECBVlv_rAct_WERT | unsigned int | % | 0.012207 | 0.000000 | ECBVlv_rAct | Duty cycle - EGR cooler bypass | |
ECBVlv_rPs | 0x0FA1 | STAT_ECBVlv_rPs_WERT | unsigned int | % | 0.010000 | 0.000000 | ECBVlv_rPs | EGR cooler bypass - output duty cycle | |
ECBVlv_r | 0x0FA2 | STAT_ECBVlv_r_WERT | unsigned int | % | 0.001526 | 0.000000 | ECBVlv_r | Target duty cycle - EGR cooler bypass | |
Eep_EnvRamCheckInfo | 0x0FAA | STAT_Eep_EnvRamCheckInfo_WERT | unsigned char | - | 1.000000 | 0.000000 | Eep_EnvRamCheckInfo | Info about the Envram Check | |
Cpu_rMaxUsrStackCons_mp | 0x0FAB | STAT_Cpu_rMaxUsrStackCons_mp_WERT | unsigned char | % | 0.392157 | 0.000000 | Cpu_rMaxUsrStackCons_mp | Maximum fill level of the ERCOSEK user stack (stored in EEPROM) (1 byte) | |
Cpu_rMaxCSACons_mp | 0x0FAC | STAT_Cpu_rMaxCSACons_mp_WERT | unsigned char | % | 0.392157 | 0.000000 | Cpu_rMaxCSACons_mp | Maximum fill level of the Context Save Area (CSA) (stored in EEPROM) (1 byte) | |
ITUMG | 0x0FD2 | STAT_UMGEBUNGSTEMPERATUR_WERT | unsigned int | degC | 0.100000 | -273.140000 | EnvT_t | Ambient temperature | |
ISMIL | 0x1004 | STAT_MIL_EIN_WERT | unsigned char | - | 1.000000 | 0.000000 | ErrLmp_stMILReq | Request status - MIL | |
ISSLA | 0x1005 | STAT_ANFORDERUNGSSTATUS_SYSTEMLAMPE_WERT | unsigned char | - | 1.000000 | 0.000000 | ErrLmp_stSVSReq | Request status - system lamp | |
ErrLmp_stMIL | 0x1006 | STAT_ErrLmp_stMIL_WERT | unsigned char | - | 1.000000 | 0.000000 | ErrLmp_stMIL | MIL status indicator | |
ErrLmp_stSVS | 0x1007 | STAT_ErrLmp_stSVS_WERT | unsigned char | - | 1.000000 | 0.000000 | ErrLmp_stSVS | SVS fault lamp status | |
RngMod_trqFrc | 0x1036 | STAT_RngMod_trqFrc_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | RngMod_trqFrc | Current frictional torque | |
BrkP_pSens | 0x1068 | STAT_BrkP_pSens_WERT | unsigned int | bar | 1.000000 | 0.000000 | BrkP_pSens | Brake vacuum - linearised sensor value | |
IPBUS2 | 0x1069 | STAT_BREMSUNTERDRUCK2_WERT | unsigned int | bar | 1.000000 | 0.000000 | BrkP_p | Brake vacuum | |
IUBUS | 0x106A | STAT_BREMSUNTERDRUCK_SPANNUNG_WERT | unsigned int | mV | 0.200000 | 0.000000 | BrkP_uRaw | Brake vacuum - raw sensor voltage value | |
ISBLS | 0x106B | STAT_BREMSLICHTSCHALTER_EIN_WERT | unsigned char | - | 1.000000 | 0.000000 | Brk_st | Brake applied message | |
MoFBrk_st | 0x106C | STAT_MoFBrk_st_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFBrk_st | Status of the brake light switch | |
Com_stLmpPrkBrk | 0x106D | STAT_Com_stLmpPrkBrk_WERT | unsigned char | - | 1.000000 | 0.000000 | Com_stLmpPrkBrk | Parking brake lamp status in the combi | |
ISBLT | 0x106E | STAT_BREMSLICHTTESTSCHALTER_EIN_WERT | unsigned char | - | 1.000000 | 0.000000 | Brk_stRed | Status of the redundant brake | |
St_poelreg1 | 0x1072 | STAT_St_poelreg1_WERT | unsigned char | - | 1.000000 | 0.000000 | St_poelreg1 | Status byte - regulated oil pump 1 | |
St_poelreg2 | 0x1073 | STAT_St_poelreg2_WERT | unsigned char | - | 1.000000 | 0.000000 | St_poelreg2 | Status byte - regulated oil pump 2 | |
St_poelreg3 | 0x1074 | STAT_St_poelreg3_WERT | unsigned char | - | 1.000000 | 0.000000 | St_poelreg3 | Status byte - regulated oil pump 3 | |
St_poelreg4 | 0x1075 | STAT_St_poelreg4_WERT | unsigned char | - | 1.000000 | 0.000000 | St_poelreg4 | Status byte - regulated oil pump 4 | |
St_poelreg5 | 0x1076 | STAT_St_poelreg5_WERT | unsigned char | - | 1.000000 | 0.000000 | St_poelreg5 | Status byte - regulated oil pump 5 | |
St_poelreg6 | 0x1077 | STAT_St_poelreg6_WERT | unsigned char | - | 1.000000 | 0.000000 | St_poelreg6 | Status byte - Regulated oil pump 6 | |
St_poelreg7 | 0x1078 | STAT_St_poelreg7_WERT | unsigned char | - | 1.000000 | 0.000000 | St_poelreg7 | Status byte - regulated oil pump 7 | |
St_poelreg8 | 0x1079 | STAT_St_poelreg8_WERT | unsigned char | - | 1.000000 | 0.000000 | St_poelreg8 | Status byte - regulated oil pump 8 | |
St_poelreg9 | 0x107A | STAT_St_poelreg9_WERT | unsigned char | - | 1.000000 | 0.000000 | St_poelreg9 | Status byte - regulated oil pump 9 | |
St_poelreg10 | 0x107B | STAT_St_poelreg10_WERT | unsigned char | - | 1.000000 | 0.000000 | St_poelreg10 | Status byte - Regulated oil pump 10 | |
St_poelreg11 | 0x107C | STAT_St_poelreg11_WERT | unsigned char | - | 1.000000 | 0.000000 | St_poelreg11 | Status byte - regulated oil pump 11 | |
St_ntagr | 0x107D | STAT_St_ntagr_WERT | unsigned char | - | 1.000000 | 0.000000 | St_ntagr | Status word low temperature EGR | |
SwSABMW_flgTstpOilSys1 | 0x1090 | STAT_SwSABMW_flgTstpOilSys1_WERT | unsigned char | - | 1.000000 | 0.000000 | SwSABMW_flgTstpOilSys1 | Tester request for controlled oil pump - status byte 1 | |
SwSABMW_rOilPres | 0x1091 | STAT_SwSABMW_rOilPres_WERT | unsigned int | % | 0.001526 | 0.000000 | SwSABMW_rOilPres | Keying ratio of KFR valve control for regulated oil pump | |
SwSABMW_flgTstpOilSys2 | 0x1092 | STAT_SwSABMW_flgTstpOilSys2_WERT | unsigned char | - | 1.000000 | 0.000000 | SwSABMW_flgTstpOilSys2 | Tester request for controlled oil pump - status byte 2 | |
IPBUS | 0x109A | STAT_BREMSUNTERDRUCK_WERT | unsigned int | hPa | 1.000000 | 0.000000 | Pbremsu | Brake booster vacuum | |
St_gen | 0x10CC | STAT_St_gen_WERT | unsigned char | - | 1.000000 | 0.000000 | St_gen | Generator status | |
Km_st | 0x10CD | STAT_Km_st_WERT | unsigned int | km | 10.000000 | 0.000000 | Km_st | Mileage (layer) | |
Tn_abstellm | 0x10CE | STAT_Tn_abstellm_WERT | unsigned int | min | 1.000000 | 0.000000 | Tn_abstellm | Stopping time in minutes | |
Nkw | 0x10CF | STAT_Nkw_WERT | unsigned int | rpm | 1.000000 | 0.000000 | Nkw | Engine speed at the crankshaft | |
T_saison | 0x10D0 | STAT_T_saison_WERT | unsigned int | degC | 0.100000 | 0.000000 | T_saison | Seasonal temperature | |
Soc_quali | 0x10D2 | STAT_Soc_quali_WERT | unsigned int | Ah | 0.018200 | 0.000000 | Soc_quali | Counter accuracy state of charge determination | |
Q_iruhe2 | 0x10D3 | STAT_Q_iruhe2_WERT | unsigned int | Ah | 0.018200 | 0.000000 | Q_iruhe2 | Discharge amount during time with increased idle current | |
Q_rekupah | 0x10D5 | STAT_Q_rekupah_WERT | unsigned int | Ah | 0.018204 | 0.000000 | Q_rekupah | Amount of energy recuperated | |
St_igr_nv | 0x10D6 | STAT_St_igr_nv_WERT | unsigned char | - | 1.000000 | 0.000000 | St_igr_nv | Status word - iGR charge control | |
St_co2mng_nv | 0x10D7 | STAT_St_co2mng_nv_WERT | unsigned char | - | 1.000000 | 0.000000 | St_co2mng_nv | Status word - iGR charge control | |
Drl_anz_pwf | 0x10D8 | STAT_Drl_anz_pwf_WERT | unsigned char | - | 1.000000 | 0.000000 | Drl_anz_pwf | Number of powerfails (DAROL) | |
Drl_km_bzg | 0x10D9 | STAT_Drl_km_bzg_WERT | unsigned int | km | 8.000000 | 0.000000 | Drl_km_bzg | Accumulated reference mileage for overruns (DAROL - resolution 8 km)) | |
Isgusm_chipherst | 0x10DC | STAT_Isgusm_chipherst_WERT | unsigned char | - | 1.000000 | 0.000000 | Isgusm_chipherst | Chip manufacturer (ISG) | |
Isgusm_chipvers | 0x10DD | STAT_Isgusm_chipvers_WERT | unsigned char | - | 1.000000 | 0.000000 | Isgusm_chipvers | Chip version (ISG) | |
Isgusm_df | 0x10DE | STAT_Isgusm_df_WERT | unsigned int | - | 0.005000 | 0.000000 | Isgusm_df | Generator load (ISG) | |
Isgusm_dfreg | 0x10DF | STAT_Isgusm_dfreg_WERT | unsigned int | - | 0.005000 | 0.000000 | Isgusm_dfreg | Dynamo field from controller (BSD, LIN, SGR) | |
Isgusm_herst | 0x10E0 | STAT_Isgusm_herst_WERT | unsigned char | - | 1.000000 | 0.000000 | Isgusm_herst | Chip manufacturer (ISG) | |
Isgusm_i | 0x10E1 | STAT_Isgusm_i_WERT | unsigned int | A | 0.125000 | 0.000000 | Isgusm_i | Generator current (ISG) | |
Isgusm_ierr | 0x10E2 | STAT_Isgusm_ierr_WERT | unsigned int | A | 0.001250 | 0.000000 | Isgusm_ierr | Excitation current (ISG) | |
Isgusm_ierrgrenz | 0x10E3 | STAT_Isgusm_ierrgrenz_WERT | unsigned int | A | 0.001250 | 0.000000 | Isgusm_ierrgrenz | Exciter current limit (ISG) | |
Isgusm_ierrgrenzz | 0x10E4 | STAT_Isgusm_ierrgrenzz_WERT | unsigned int | min | 1.000000 | 0.000000 | Isgusm_ierrgrenzz | Time counter for limit exciter current due to high temperature on (ISG) | |
Isgusm_ierrreg | 0x10E5 | STAT_Isgusm_ierrreg_WERT | unsigned int | A | 0.001250 | 0.000000 | Isgusm_ierrreg | Intermediate value of limiting exciter current for ramp (ISG) | |
Isgusm_m | 0x10E6 | STAT_Isgusm_m_WERT | unsigned int | Nm | 0.100000 | 0.000000 | Isgusm_m | Generator torque (ISG) | |
Isgusm_makenn | 0x10E7 | STAT_Isgusm_makenn_WERT | unsigned char | - | 1.000000 | 0.000000 | Isgusm_makenn | Machine identification (according to USM) | |
Isgusm_tchipfil | 0x10E8 | STAT_Isgusm_tchipfil_WERT | unsigned char | degC | 1.000000 | -50.000000 | Isgusm_tchipfil | Filtered chip temperature generator (ISG) | |
ITGEE | 0x10E9 | STAT_GENERATOR_ELEKTRONIKTEMPERATUR_WERT | unsigned char | degC | 1.000000 | -50.000000 | Isgusm_tchipreg | Chip temperature from controller (BSD, LIN, SGR - resolution 1 °C) | |
Isgusm_typ | 0x10EA | STAT_Isgusm_typ_WERT | unsigned char | - | 1.000000 | 0.000000 | Isgusm_typ | Detection type (BSD, LIN, SGR) | |
FlSys_qFlNrmInj | 0x10EB | STAT_FlSys_qFlNrmInj_WERT | unsigned int | l | 1.000000 | 0.000000 | FlSys_qFlNrmInj | Torque-forming quantity by the injector | |
St_isgusm_status | 0x10EC | STAT_St_isgusm_status_WERT | unsigned int | - | 1.000000 | 0.000000 | St_isgusm_status | Current status generator (ISG) | |
Tlrgen | 0x10ED | STAT_Tlrgen_WERT | unsigned char | s | 0.100000 | 0.000000 | Tlrgen | Setpoint Load-response time generator | |
Tlrgenschw | 0x10EE | STAT_Tlrgenschw_WERT | unsigned int | rpm | 1.000000 | 0.000000 | Tlrgenschw | Switch-off threshold Loadresponse | |
St_loadresp | 0x10EF | STAT_St_loadresp_WERT | unsigned char | - | 1.000000 | 0.000000 | St_loadresp | Status word | |
Mdk_ist | 0x10F9 | STAT_Mdk_ist_WERT | unsigned int | Nm | 0.100000 | 0.000000 | Mdk_ist | Clutch actual torque - Layer | |
St_zrs | 0x10FA | STAT_St_zrs_WERT | unsigned char | - | 1.000000 | 0.000000 | St_zrs | Status - Forced Reverse | |
SCRPOD_stEmptRet | 0x10FE | STAT_SCRPOD_stEmptRet_WERT | unsigned char | - | 1.000000 | 0.000000 | SCRPOD_stEmptRet | SCR engine test - status Empty test | |
DewDet_stHtgThresLSUHit_mp_0 | 0x1112 | STAT_DewDet_stHtgThresLSUHit_mp_0_WERT | unsigned char | - | 1.000000 | 0.000000 | DewDet_stHtgThresLSUHit_mp_0 | Heater enable end of dew point LSU 0 | |
DewDet_stHtgThresLSUHit_mp_1 | 0x1113 | STAT_DewDet_stHtgThresLSUHit_mp_1_WERT | unsigned char | - | 1.000000 | 0.000000 | DewDet_stHtgThresLSUHit_mp_1 | Heater enable end of dew point LSU 1 | |
DewDet_stHtgThresLSUHit_mp_2 | 0x1114 | STAT_DewDet_stHtgThresLSUHit_mp_2_WERT | unsigned char | - | 1.000000 | 0.000000 | DewDet_stHtgThresLSUHit_mp_2 | Heater enable end of dew point LSU 2 | |
DewDet_stHtgThresLSUHit_mp_3 | 0x1115 | STAT_DewDet_stHtgThresLSUHit_mp_3_WERT | unsigned char | - | 1.000000 | 0.000000 | DewDet_stHtgThresLSUHit_mp_3 | Heater enable end of dew point LSU 3 | |
DewDet_stHtgThresLSUHit_mp_4 | 0x1116 | STAT_DewDet_stHtgThresLSUHit_mp_4_WERT | unsigned char | - | 1.000000 | 0.000000 | DewDet_stHtgThresLSUHit_mp_4 | Heater enable end of dew point LSU 4 | |
DewDet_ctCldStrtLSU_mp_0 | 0x111C | STAT_DewDet_ctCldStrtLSU_mp_0_WERT | unsigned char | - | 1.000000 | 0.000000 | DewDet_ctCldStrtLSU_mp_0 | Counter for repeated cold starts 0 | |
DewDet_ctCldStrtLSU_mp_1 | 0x111D | STAT_DewDet_ctCldStrtLSU_mp_1_WERT | unsigned char | - | 1.000000 | 0.000000 | DewDet_ctCldStrtLSU_mp_1 | Counter for repeated cold starts 1 | |
DewDet_ctCldStrtLSU_mp_2 | 0x111E | STAT_DewDet_ctCldStrtLSU_mp_2_WERT | unsigned char | - | 1.000000 | 0.000000 | DewDet_ctCldStrtLSU_mp_2 | Counter for repeated cold starts 2 | |
DStgy_cntAdapStrtEEP_mp | 0x111F | STAT_DSTGY_CNTADAPSTRTEEP_MP_WERT | unsigned int | - | 1.000000 | 0.000000 | DStgy_cntAdapStrtEEP_mp | Number of SCR adaptations started | |
DStgy_cntAdapSucEEP_mp | 0x1120 | STAT_DSTGY_CNTADAPSUCEEP_MP_WERT | unsigned int | - | 1.000000 | 0.000000 | DStgy_cntAdapSucEEP_mp | Number of successful SCR adaptations | |
DStgy_dmNOxEmiEEP_mp | 0x1121 | STAT_DSTGY_DMNOXEMIEEP_MP_WERT | unsigned long | g/km | 0.001000 | 0.000000 | DStgy_dmNOxEmiEEP_mp | Weighted NOx raw emissions per km | |
DStgy_etaModEEP_mp | 0x1122 | STAT_DSTGY_ETAMODEEP_MP_WERT | unsigned int | - | 0.001000 | 0.000000 | DStgy_etaModEEP_mp | Averaged SCR efficiency from model | |
DStgy_etaSensEEP_mp | 0x1123 | STAT_DSTGY_ETASENSEEP_MP_WERT | unsigned int | - | 0.001000 | 0.000000 | DStgy_etaSensEEP_mp | averaged SCR efficiency over sensor | |
DStgy_facWghEmiEEP_mp | 0x1124 | STAT_DSTGY_FACWGHEMIEEP_MP_WERT | unsigned int | - | 0.000100 | 0.000000 | DStgy_facWghEmiEEP_mp | Weighting factor NOx raw emissions | |
DStgy_facWghEtaEEP_mp | 0x1125 | STAT_DSTGY_FACWGHETAEEP_MP_WERT | unsigned int | - | 0.001000 | 0.000000 | DStgy_facWghEtaEEP_mp | Weighting factor SCR efficiency | |
DStgy_lDstPrDrvCyclEEP_mp | 0x1126 | STAT_DSTGY_LDSTPRDRVCYCLEEP_MP_WERT | unsigned long | km | 1.000000 | 0.000000 | DStgy_lDstPrDrvCyclEEP_mp | Weighted driving distance per driving cycle | |
DStgy_lTotDstAdapSucEEP_mp | 0x1127 | STAT_DSTGY_LTOTDSTADAPSUCEEP_MP_WERT | unsigned long | km | 0.100000 | 0.000000 | DStgy_lTotDstAdapSucEEP_mp | km status at last successful SCR adaptation | |
DStgy_mEstNOxDsEEP_mp | 0x1128 | STAT_DSTGY_MESTNOXDSEEP_MP_WERT | unsigned int | g | 0.100000 | 0.000000 | DStgy_mEstNOxDsEEP_mp | Cumulative NOx emissions after SCR from model | |
SCRPOD_stDosMeasStrt | 0x1129 | STAT_SCRPOD_stDosMeasStrt_WERT | unsigned char | - | 1.000000 | 0.000000 | SCRPOD_stDosMeasStrt | Status of the motor tests qDosMeasStrt | |
SCRPOD_stDosMeasStrtRet | 0x112A | STAT_SCRPOD_stDosMeasStrtRet_WERT | unsigned char | - | 1.000000 | 0.000000 | SCRPOD_stDosMeasStrtRet | Return value of the motor test qDosMeasStrt for diagnostic tester | |
SCRPOD_stDosMeas | 0x112B | STAT_SCRPOD_stDosMeas_WERT | unsigned char | - | 1.000000 | 0.000000 | SCRPOD_stDosMeas | Status of the engine test qDosMeas | |
SCRPOD_qDosMeasAct | 0x112C | STAT_SCRPOD_qDosMeasAct_WERT | unsigned int | g | 0.045777 | 0.000000 | SCRPOD_qDosMeasAct | Current dosing quantity for the engine test Dosing quantity measurement | |
SCRPOD_qDosMeas | 0x112D | STAT_SCRPOD_qDosMeas_WERT | unsigned int | g | 0.045777 | 0.000000 | SCRPOD_qDosMeas | Dosing quantity for the motor test Dosing quantity measurement | |
UDosVlv_rDyc | 0x112E | STAT_UDosVlv_rDyc_WERT | unsigned int | % | 0.010000 | 0.000000 | UDosVlv_rDyc | Setpoint for the duty cycle of the metering valve output stage | |
CoSCR_st | 0x1130 | STAT_CoSCR_st_WERT | unsigned char | - | 1.000000 | 0.000000 | CoSCR_st | Status of the hydraulic SCR system | |
CoSCR_stSub | 0x1131 | STAT_CoSCR_stSub_WERT | unsigned char | - | 1.000000 | 0.000000 | CoSCR_stSub | Sub-state of the hydraulic SCR system | |
DStgy_stMetStgy | 0x1132 | STAT_DStgy_stMetStgy_WERT | unsigned char | - | 1.000000 | 0.000000 | DStgy_stMetStgy | Release of the dosing by the dosing strategy | |
DStgy_stCondDos | 0x1133 | STAT_DStgy_stCondDos_WERT | unsigned long | - | 1.000000 | 0.000000 | DStgy_stCondDos | Enable status of dosing strategy (bitwise) | |
UDC_mRdcAgDosQnt | 0x1134 | STAT_UDC_mRdcAgDosQnt_WERT | unsigned long | g | 0.001000 | 0.000000 | UDC_mRdcAgDosQnt | Urea consumption since last system filling | |
UDC_mRdcAgAct | 0x1136 | STAT_UDC_mRdcAgAct_WERT | unsigned int | g | 0.488289 | 0.000000 | UDC_mRdcAgAct | Urea consumption since last engine start | |
SCR_tUCatUsT | 0x1138 | STAT_SCR_tUCatUsT_WERT | unsigned int | degC | 0.031281 | -50.000000 | SCR_tUCatUsT | Temperature before SCR catalytic converter | |
SCR_uRawUCatUsT | 0x113A | STAT_SCR_uRawUCatUsT_WERT | unsigned int | mV | 0.076295 | 0.000000 | SCR_uRawUCatUsT | Raw sensor voltage of the temperature sensor upstream of the urea catalytic converter | |
SCRT_tAvrg | 0x113B | STAT_SCRT_tAvrg_WERT | unsigned int | degC | 0.031281 | -50.000000 | SCRT_tAvrg | Weighted average temperature of the SCR catalyst | |
SCR_tUTnkT | 0x113D | STAT_SCR_tUTnkT_WERT | unsigned int | degC | 0.031281 | -50.000000 | SCR_tUTnkT | Temperature of the urea-water solution | |
SCR_uRawUTnkT | 0x113F | STAT_SCR_uRawUTnkT_WERT | unsigned int | mV | 0.076295 | 0.000000 | SCR_uRawUTnkT | Sensor voltage of the temperature sensor of the urea-water solution | |
SCR_pUPmpP | 0x1140 | STAT_SCR_pUPmpP_WERT | unsigned int | hPa | 0.122072 | 0.000000 | SCR_pUPmpP | Pump pressure of the SCR system | |
SCR_uRawUPmpP | 0x1142 | STAT_SCR_uRawUPmpP_WERT | unsigned int | mV | 0.076295 | 0.000000 | SCR_uRawUPmpP | Sensor voltage of the pressure sensor of the HWL pump | |
Exh_rNOxNoCat2Ds | 0x1143 | STAT_Exh_rNOxNoCat2Ds_WERT | unsigned int | ppm | 0.032044 | -100.000000 | Exh_rNOxNoCat2Ds | Signal from NOx sensor 2 (offset-corrected) | |
Exh_rNOxNSCDs | 0x1145 | STAT_Exh_rNOxNSCDs_WERT | unsigned int | ppm | 0.032044 | -100.000000 | Exh_rNOxNSCDs | Signal from NOx sensor 1 (offset-corrected) | |
ASMod_rNOxEG | 0x1147 | STAT_ASMod_rNOxEG_WERT | unsigned int | - | 0.000015 | 0.000000 | ASMod_rNOxEG | Proportion of NOx emission in exhaust gas mass flow after combustion | |
ASMod_dmNOxEG | 0x1149 | STAT_ASMod_dmNOxEG_WERT | unsigned long | mg/s | 0.010000 | 0.000000 | ASMod_dmNOxEG | NOx mass flow in exhaust gas after combustion | |
ASMod_dmEGFld_0 | 0x114A | STAT_ASMod_dmEGFld0_WERT | unsigned int | kg/h | 0.022889 | 0.000000 | ASMod_dmEGFld_0 | Exhaust gas mass flow field 0 | |
ASMod_dmEGFld_1 | 0x114B | STAT_ASMod_dmEGFld1_WERT | unsigned int | kg/h | 0.022889 | 0.000000 | ASMod_dmEGFld_1 | Exhaust gas mass flow field 1 | |
ASMod_dmEGFld_2 | 0x114C | STAT_ASMod_dmEGFld2_WERT | unsigned int | kg/h | 0.022889 | 0.000000 | ASMod_dmEGFld_2 | Exhaust gas mass flow field 2 | |
ASMod_dmEGFld_3 | 0x114D | STAT_ASMod_dmEGFld3_WERT | unsigned int | kg/h | 0.022889 | 0.000000 | ASMod_dmEGFld_3 | Exhaust gas mass flow field 3 | |
ASMod_dmEGFld_4 | 0x114E | STAT_ASMod_dmEGFld4_WERT | unsigned int | kg/h | 0.022889 | 0.000000 | ASMod_dmEGFld_4 | Exhaust gas mass flow field 4 | |
ASMod_dmEGFld_5 | 0x114F | STAT_ASMod_dmEGFld5_WERT | unsigned int | kg/h | 0.022889 | 0.000000 | ASMod_dmEGFld_5 | Exhaust gas mass flow field 5 | |
ASMod_dmEGFld_6 | 0x1150 | STAT_ASMod_dmEGFld6_WERT | unsigned int | kg/h | 0.022889 | 0.000000 | ASMod_dmEGFld_6 | Exhaust gas mass flow field 6 | |
ASMod_dmEGFld_7 | 0x1151 | STAT_ASMod_dmEGFld7_WERT | unsigned int | kg/h | 0.022889 | 0.000000 | ASMod_dmEGFld_7 | Exhaust gas mass flow field 7 | |
ASMod_dmEGFld_8 | 0x1152 | STAT_ASMod_dmEGFld8_WERT | unsigned int | kg/h | 0.022889 | 0.000000 | ASMod_dmEGFld_8 | Exhaust gas mass flow field 8 | |
ASMod_dmEGFld_9 | 0x1153 | STAT_ASMod_dmEGFld9_WERT | unsigned int | kg/h | 0.022889 | 0.000000 | ASMod_dmEGFld_9 | Field of exhaust gas mass flows 9 | |
SCRFFC_rPPMNOxUs | 0x1154 | STAT_SCRFFC_rPPMNOxUs_WERT | unsigned int | ppm | 0.032044 | -100.000000 | SCRFFC_rPPMNOxUs | NOx raw emissions | |
DewDet_stShOff_mp | 0x1156 | STAT_DewDet_stShOff_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | DewDet_stShOff_mp | Status Withdrawal of the release condition of the probe heater | |
SCRMod_mEstNH3Ld | 0x1159 | STAT_SCRMod_mEstNH3Ld_WERT | unsigned int | g | 0.001000 | 0.000000 | SCRMod_mEstNH3Ld | Current NH3 storage level | |
DStgy_dmNH3Curr | 0x115A | STAT_DStgy_dmNH3Curr_WERT | unsigned long | mg/s | 0.010000 | 0.000000 | DStgy_dmNH3Curr | Current NH3 mass flow added | |
UDosVlv_rPs | 0x115B | STAT_UDosVlv_rPs_WERT | unsigned int | % | 0.001526 | 0.000000 | UDosVlv_rPs | Metering valve - output duty cycle | |
UDC_dmRdcAgDos | 0x115D | STAT_UDC_dmRdcAgDos_WERT | unsigned int | mg/s | 0.251774 | 0.000000 | UDC_dmRdcAgDos | Feedback of the dosed quantity | |
UPmpMot_r | 0x115E | STAT_UPmpMot_r_WERT | unsigned int | % | 0.001526 | 0.000000 | UPmpMot_r | Duty cycle for controlling the pump motor (setpoint) | |
UPmpMot_rPs | 0x1160 | STAT_UPmpMot_rPs_WERT | unsigned int | % | 0.001526 | 0.000000 | UPmpMot_rPs | Reducing agent feed pump - output duty cycle | |
UHC_stCtl | 0x1162 | STAT_UHC_stCtl_WERT | unsigned char | - | 1.000000 | 0.000000 | UHC_stCtl | Status of the tank temperature and thawing of the pressure line | |
UHC_stDfrstChk | 0x1163 | STAT_UHC_stDfrstChk_WERT | unsigned char | - | 1.000000 | 0.000000 | UHC_stDfrstChk | Status of the thawing check | |
UHC_stUTnkTemp_mp | 0x1164 | STAT_UHC_stUTnkTemp_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | UHC_stUTnkTemp_mp | Status - tank frozen | |
UHtrTnk_st | 0x1165 | STAT_UHtrTnk_st_WERT | unsigned int | - | 1.000000 | 0.000000 | UHtrTnk_st | Status of the final stage for the tank heater | |
UHtrTnk_stPs | 0x1166 | STAT_UHtrTnk_stPs_WERT | unsigned int | - | 1.000000 | 0.000000 | UHtrTnk_stPs | Status - set point for the tank heater | |
UHtrPL_st | 0x1167 | STAT_UHtrPL_st_WERT | unsigned int | - | 1.000000 | 0.000000 | UHtrPL_st | Status - set point for the pressure line heater | |
UHtrPL_stPs | 0x1168 | STAT_UHtrPL_stPs_WERT | unsigned int | - | 1.000000 | 0.000000 | UHtrPL_stPs | Status of the final stage for the pressure line heater | |
SCR_rUTnkLvl | 0x1169 | STAT_SCR_rUTnkLvl_WERT | unsigned int | % | 0.001526 | 0.000000 | SCR_rUTnkLvl | Tank level - active tank | |
SCR_rUPasTnkLvl | 0x116D | STAT_SCR_rUPasTnkLvl_WERT | unsigned int | % | 0.001526 | 0.000000 | SCR_rUPasTnkLvl | Tank level - passive tank | |
UPmpReFl_st | 0x116F | STAT_UPmpReFl_st_WERT | unsigned char | - | 1.000000 | 0.000000 | UPmpReFl_st | Status - transfer pump (setpoint) | |
URevVlv_st | 0x1171 | STAT_URevVlv_st_WERT | unsigned char | - | 1.000000 | 0.000000 | URevVlv_st | Status - digital output to 4/2-way valve (setpoint) | |
URevVlv_stPs | 0x1172 | STAT_URevVlv_stPs_WERT | unsigned char | - | 1.000000 | 0.000000 | URevVlv_stPs | Status - digital output to 4/2-way valve (final stage) | |
SCRAd_ctSlip | 0x1173 | STAT_SCRAd_ctSlip_WERT | unsigned int | - | 1.000000 | 0.000000 | SCRAd_ctSlip | Number of adaptations carried out | |
SCRAd_facQtyAdap | 0x1174 | STAT_SCRAd_facQtyAdap_WERT | unsigned int | - | 0.003052 | 0.000000 | SCRAd_facQtyAdap | Long-term adaptation factor | |
SCRAd_facPlaus_Fld_0 | 0x1175 | STAT_SCRAd_facPlaus_Fld0_WERT | unsigned long | - | 0.000100 | 0.000000 | SCRAd_facPlaus_Fld_0 | Array for storing the last three plausibilities 0 | |
SCRAd_facPlaus_Fld_1 | 0x1176 | STAT_SCRAd_facPlaus_Fld1_WERT | unsigned long | - | 0.000100 | 0.000000 | SCRAd_facPlaus_Fld_1 | Array for storing the last three plausibility values 1 | |
SCRAd_facPlaus_Fld_2 | 0x1177 | STAT_SCRAd_facPlaus_Fld2_WERT | unsigned long | - | 0.000100 | 0.000000 | SCRAd_facPlaus_Fld_2 | Array for storing the last three plausibility values 2 | |
SCRChk_rEtaAvrg1Fld_0 | 0x117B | STAT_SCRChk_rEtaAvrg1Fld_0_WERT | unsigned int | - | 0.000763 | 0.000000 | SCRChk_rEtaAvrg1Fld_0 | Last stored quotient from OBD-SCR-Cat (ratio limit/actual efficiency) - map 1 0 | |
SCRChk_rEtaAvrg1Fld_1 | 0x117C | STAT_SCRChk_rEtaAvrg1Fld_1_WERT | unsigned int | - | 0.000763 | 0.000000 | SCRChk_rEtaAvrg1Fld_1 | Last stored quotient from OBD-SCR-Cat (ratio limit/actual efficiency) - map 1 1 | |
SCRChk_rEtaAvrg1Fld_2 | 0x117D | STAT_SCRChk_rEtaAvrg1Fld_2_WERT | unsigned int | - | 0.000763 | 0.000000 | SCRChk_rEtaAvrg1Fld_2 | Last stored quotient from OBD-SCR-Cat (ratio limit/actual efficiency) - map 1 2 | |
SCRChk_rEtaAvrg1Fld_3 | 0x117E | STAT_SCRChk_rEtaAvrg1Fld_3_WERT | unsigned int | - | 0.000763 | 0.000000 | SCRChk_rEtaAvrg1Fld_3 | Last stored quotient from OBD-SCR-Cat (ratio limit/actual efficiency) - map 1 3 | |
SCRChk_rEtaAvrg1Fld_4 | 0x117F | STAT_SCRChk_rEtaAvrg1Fld_4_WERT | unsigned int | - | 0.000763 | 0.000000 | SCRChk_rEtaAvrg1Fld_4 | Last stored quotient from OBD-SCR-Cat (ratio limit/actual efficiency) - map 1 4 | |
SCRChk_rEtaAvrg2Fld_0 | 0x1185 | STAT_SCRChk_rEtaAvrg2Fld_0_WERT | unsigned int | - | 0.000763 | 0.000000 | SCRChk_rEtaAvrg2Fld_0 | Last stored quotient from OBD-SCR-Kat (ratio limit/actual efficiency) - map 2 0 | |
SCRChk_rEtaAvrg2Fld_1 | 0x1186 | STAT_SCRChk_rEtaAvrg2Fld_1_WERT | unsigned int | - | 0.000763 | 0.000000 | SCRChk_rEtaAvrg2Fld_1 | Last stored quotient from OBD-SCR-Kat (ratio of limit/actual efficiency) - map 2 1 | |
SCRChk_rEtaAvrg2Fld_2 | 0x1187 | STAT_SCRChk_rEtaAvrg2Fld_2_WERT | unsigned int | - | 0.000763 | 0.000000 | SCRChk_rEtaAvrg2Fld_2 | Last stored quotient from OBD-SCR-Cat (ratio limit/actual efficiency) - map 2 2 | |
SCRChk_rEtaAvrg2Fld_3 | 0x1188 | STAT_SCRChk_rEtaAvrg2Fld_3_WERT | unsigned int | - | 0.000763 | 0.000000 | SCRChk_rEtaAvrg2Fld_3 | Last stored quotient from OBD-SCR catalytic converter (ratio limit/actual efficiency) - map 2 3 | |
SCRChk_rEtaAvrg2Fld_4 | 0x1189 | STAT_SCRChk_rEtaAvrg2Fld_4_WERT | unsigned int | - | 0.000763 | 0.000000 | SCRChk_rEtaAvrg2Fld_4 | Last stored quotient from OBD-SCR-Cat (ratio limit/actual efficiency) - map 2 4 | |
Exh_rNOxOfsNoCat2Ds | 0x118F | STAT_Exh_rNOxOfsNoCat2Ds_WERT | unsigned int | ppm | 0.032044 | -100.000000 | Exh_rNOxOfsNoCat2Ds | Sensor offset due to thrust calibration (downstream) | |
Exh_rNOxOfsNSCDs | 0x1190 | STAT_Exh_rNOxOfsNSCDs_WERT | unsigned int | ppm | 0.032044 | -100.000000 | Exh_rNOxOfsNSCDs | Sensor offset by thrust calibration (upstream) | |
Exh_rNOxOfsAvrgNoCat2Ds | 0x1193 | STAT_Exh_rNOxOfsAvrgNoCat2Ds_WERT | unsigned int | ppm | 0.032044 | -100.000000 | Exh_rNOxOfsAvrgNoCat2Ds | Average NOx offset signal (after SCR cat) | |
Exh_rNOxOfsAvrgNSCDs | 0x1194 | STAT_Exh_rNOxOfsAvrgNSCDs_WERT | unsigned int | ppm | 0.032044 | -100.000000 | Exh_rNOxOfsAvrgNSCDs | Average NOx offset signal (before SCR cat) | |
Exh_pSensPTrbnUs | 0x1195 | STAT_Exh_pSensPTrbnUs_WERT | unsigned int | hPa | 1.000000 | 0.000000 | Exh_pSensPTrbnUs | Exhaust gas pressure before turbine - from sensor curve | |
SCRAd_facQtyAdapRaw_mp | 0x1196 | STAT_SCRAd_facQtyAdapRaw_mp_WERT | unsigned int | - | 0.003052 | 0.000000 | SCRAd_facQtyAdapRaw_mp | Long-term adaptation factor (raw value) | |
SCR_rRawUTnkLvl | 0x1197 | STAT_SCR_rRawUTnkLvl_WERT | unsigned int | % | 0.001526 | 0.000000 | SCR_rRawUTnkLvl | Duty cycle for PWM output (for bipolar sensor) | |
SCR_rRawUPasTnkLvl | 0x1198 | STAT_SCR_rRawUPasTnkLvl_WERT | unsigned int | % | 0.001526 | 0.000000 | SCR_rRawUPasTnkLvl | Duty cycle for PWM output passive tank (for bipolar sensor) | |
UDC_mRdcAgRmn | 0x1199 | STAT_UDC_mRdcAgRmn_WERT | unsigned int | g | 0.500000 | 0.000000 | UDC_mRdcAgRmn | Remaining tank quantity active tank | |
UDC_stDetReFill | 0x119A | STAT_UDC_stDetReFill_WERT | unsigned char | - | 1.000000 | 0.000000 | UDC_stDetReFill | Refuelling status | |
UDC_stReFill | 0x119B | STAT_UDC_stReFill_WERT | unsigned char | - | 1.000000 | 0.000000 | UDC_stReFill | Status message after refuelling with reducing agent | |
UDC_stDetPasTnkReFill | 0x119C | STAT_UDC_stDetPasTnkReFill_WERT | unsigned int | - | 1.000000 | 0.000000 | UDC_stDetPasTnkReFill | Status of refuelling (passive tank) | |
UHC_stCReq | 0x119E | STAT_UHC_stCReq_WERT | unsigned char | - | 1.000000 | 0.000000 | UHC_stCReq | Request to heat the tank and/or the pressure line | |
UHC_stC1 | 0x119F | STAT_UHC_stC1_WERT | unsigned char | - | 1.000000 | 0.000000 | UHC_stC1 | Status of the C1 - Statemachine | |
UHC_stC2 | 0x11A0 | STAT_UHC_stC2_WERT | unsigned char | - | 1.000000 | 0.000000 | UHC_stC2 | Status of the C2 - state machine | |
UHC_iToT | 0x11A1 | STAT_UHC_iToT_WERT | unsigned int | mA | 0.500008 | 0.000000 | UHC_iToT | Feedback of the accumulated heater current level | |
IIHTTNK | 0x11A2 | STAT_HEIZSTROM_TANK_WERT | unsigned int | mA | 0.500008 | 0.000000 | UHtrTnk_iSensDia | Current current level of the tank heating | |
IIHTPL | 0x11A3 | STAT_HEIZSTROM_DRUCKLEITUNG_WERT | unsigned int | mA | 0.500008 | 0.000000 | UHtrPL_iSensDia | Current current level of the pressure line or conveyor module heating | |
UHC_pwrUHtrTnkWp_mp | 0x11A4 | STAT_UHC_pwrUHtrTnkWp_mp_WERT | unsigned int | W | 0.100000 | 0.000000 | UHC_pwrUHtrTnkWp_mp | Current value of the power at the operating point | |
RFC_stRls | 0x11A6 | STAT_RFC_stRls_WERT | unsigned char | - | 1.000000 | 0.000000 | RFC_stRls | Release status - changeover function | |
RFC_mReFlQnt | 0x11A7 | STAT_RFC_mReFlQnt_WERT | unsigned long | g | 0.001000 | 0.000000 | RFC_mReFlQnt | RFC_mReFlQnt | |
UPmpReFl_rPs | 0x11A9 | STAT_UPmpReFl_rPs_WERT | unsigned int | % | 0.001526 | 0.000000 | UPmpReFl_rPs | Reducing agent transfer unit - output duty cycle | |
Exh_pOfsValActMidPPFltDiff | 0x11AA | STAT_Exh_pOfsValActMidPPFltDiff_WERT | unsigned int | hPa | 1.000000 | 0.000000 | Exh_pOfsValActMidPPFltDiff | mean value of the differential pressure offset | |
Exh_tSim1Fld_mp | 0x11AB | STAT_Exh_tSim1Fld_mp_WERT | unsigned int | degC | 0.100000 | -273.140000 | Exh_tSim1Fld_mp | Simulated temperature of the first sensor | |
Exh_tSim2Fld_mp | 0x11AC | STAT_Exh_tSim2Fld_mp_WERT | unsigned int | degC | 0.100000 | -273.140000 | Exh_tSim2Fld_mp | simulated temperature of the second sensor | |
Exh_tSim3Fld_mp | 0x11AD | STAT_Exh_tSim3Fld_mp_WERT | unsigned int | degC | 0.100000 | -273.140000 | Exh_tSim3Fld_mp | simulated temperature of the third sensor | |
Exh_mAirAftOvrRunNoCat2Ds | 0x11AE | STAT_Exh_mAirAftOvrRunNoCat2Ds_WERT | unsigned int | g | 0.100000 | 0.000000 | Exh_mAirAftOvrRunNoCat2Ds | Min. integrated mass air flow (after SCR cat) | |
Exh_mAirAftOvrRunNSCDs | 0x11AF | STAT_Exh_mAirAftOvrRunNSCDs_WERT | unsigned int | g | 0.100000 | 0.000000 | Exh_mAirAftOvrRunNSCDs | Min. integrated air mass flow (before SCR catalytic converter) | |
Exh_qStrtNSCDs_mp | 0x11B0 | STAT_Exh_qStrtNSCDs_mp_WERT | unsigned int | mg/hub | 0.010000 | 0.000000 | Exh_qStrtNSCDs_mp | Reference value of the injection quantity in the test range of the operating point | |
Exh_rNOxOfsMaxNoCat2Ds_mp | 0x11B1 | STAT_Exh_rNOxOfsMaxNoCat2Ds_mp_WERT | unsigned int | ppm | 0.025940 | -50.000000 | Exh_rNOxOfsMaxNoCat2Ds_mp | Maximum value of the NOx offset during offset learning (after SCR catalytic converter) | |
Exh_rNOxOfsMaxNSCDs_mp | 0x11B2 | STAT_Exh_rNOxOfsMaxNSCDs_mp_WERT | unsigned int | ppm | 0.025940 | -50.000000 | Exh_rNOxOfsMaxNSCDs_mp | Maximum value of the NOx offset during offset learning (before SCR catalytic converter) | |
Exh_rNOxOfsMinNoCat2Ds_mp | 0x11B3 | STAT_Exh_rNOxOfsMinNoCat2Ds_mp_WERT | unsigned int | ppm | 0.025940 | -50.000000 | Exh_rNOxOfsMinNoCat2Ds_mp | Minimum value of NOx offset during offset learning (after SCR cat) | |
Exh_rNOxOfsMinNSCDs_mp | 0x11B4 | STAT_Exh_rNOxOfsMinNSCDs_mp_WERT | unsigned int | ppm | 0.025940 | -50.000000 | Exh_rNOxOfsMinNSCDs_mp | Minimum value of NOx offset during offset learning (before SCR cat) | |
Exh_rNOxPresCompNoCat2Ds | 0x11B5 | STAT_Exh_rNOxPresCompNoCat2Ds_WERT | unsigned int | ppm | 0.025940 | -50.000000 | Exh_rNOxPresCompNoCat2Ds | pressure-compensated NOx signal (after SCR cat) | |
Exh_rNOxPresCompNSCDs | 0x11B6 | STAT_Exh_rNOxPresCompNSCDs_WERT | unsigned int | ppm | 0.025940 | -50.000000 | Exh_rNOxPresCompNSCDs | Pressure-compensated NOx signal (before SCR catalytic converter) | |
Exh_rO2LinNoCat2Ds | 0x11B7 | STAT_Exh_rO2LinNoCat2Ds_WERT | unsigned int | - | 0.000100 | -3.267800 | Exh_rO2LinNoCat2Ds | O2 concentration in exhaust gas after secondary catalyst | |
Exh_rO2LinNSCDs | 0x11B8 | STAT_Exh_rO2LinNSCDs_WERT | unsigned int | - | 0.000100 | -3.267800 | Exh_rO2LinNSCDs | O2 concentration in the exhaust gas after main catalytic converter | |
Exh_stLamLeanNoCat2Ds | 0x11B9 | STAT_Exh_stLamLeanNoCat2Ds_WERT | unsigned char | - | 1.000000 | 0.000000 | Exh_stLamLeanNoCat2Ds | Lambda signal from NOx sensor after NOx storage catalytic converter (after SCR catalytic converter) | |
Exh_stLamLeanNSCDs | 0x11BA | STAT_Exh_stLamLeanNSCDs_WERT | unsigned char | - | 1.000000 | 0.000000 | Exh_stLamLeanNSCDs | Lambda signal from NOx sensor after NOx storage catalytic converter (before SCR catalytic converter) | |
Exh_stNOxNoCat2Ds | 0x11BB | STAT_Exh_stNOxNoCat2Ds_WERT | unsigned char | - | 1.000000 | 0.000000 | Exh_stNOxNoCat2Ds | Status of the NOx signal from the secondary NOx after sensor (after SCR catalytic converter) | |
Exh_stNOxNSCDs | 0x11BC | STAT_Exh_stNOxNSCDs_WERT | unsigned char | - | 1.000000 | 0.000000 | Exh_stNOxNSCDs | NOx status signal after NOx storage catalytic converter (before SCR cat) | |
Exh_stNOxSensDiaEnaNoCat2Ds | 0x11BD | STAT_Exh_stNOxSensDiaEnaNoCat2Ds_WERT | unsigned char | - | 1.000000 | 0.000000 | Exh_stNOxSensDiaEnaNoCat2Ds | Diagnostic status of the post-NOx sensor (after SCR catalytic converter) | |
Exh_stNOxSensDiaEnaNSCDs | 0x11BE | STAT_Exh_stNOxSensDiaEnaNSCDs_WERT | unsigned char | - | 1.000000 | 0.000000 | Exh_stNOxSensDiaEnaNSCDs | Diagnostic status of post-NOx sensor (before SCR catalytic converter) | |
Exh_tiState2NSCDs_mp | 0x11BF | STAT_Exh_tiState2NSCDs_mp_WERT | unsigned int | s | 0.010000 | 0.000000 | Exh_tiState2NSCDs_mp | Timer representing a 30% change in NOx concentration | |
Exh_tiState3NSCDs_mp | 0x11C0 | STAT_Exh_tiState3NSCDs_mp_WERT | unsigned int | s | 0.010000 | 0.000000 | Exh_tiState3NSCDs_mp | Timer representing a 60% change in NOx concentration | |
SCRChk_rNOxDiffMaxUsPlaus_mp | 0x11C1 | STAT_SCRChk_rNOxDiffMaxUsPlaus_mp_WERT | unsigned int | - | 0.000122 | 0.000000 | SCRChk_rNOxDiffMaxUsPlaus_mp | Normalised NOx deviation between model value and NOx sensor before SCR | |
SCRChk_rNOxModUsFlt_mp | 0x11C2 | STAT_SCRChk_rNOxModUsFlt_mp_WERT | unsigned int | ppm | 1.000000 | 0.000000 | SCRChk_rNOxModUsFlt_mp | filtered modelled NOx concentration before SCR | |
SCRChk_etaActAvrg1_mp | 0x11C3 | STAT_SCRChk_etaActAvrg1_mp_WERT | unsigned int | - | 0.001000 | 0.000000 | SCRChk_etaActAvrg1_mp | average actual efficiency in temperature range 1 | |
SCRChk_etaActAvrg2_mp | 0x11C4 | STAT_SCRChk_etaActAvrg2_mp_WERT | unsigned int | - | 0.001000 | 0.000000 | SCRChk_etaActAvrg2_mp | average actual efficiency in temperature range 2 | |
SCRChk_rNOxDiffUsDsAvrg_mp | 0x11C5 | STAT_SCRChk_rNOxDiffUsDsAvrg_mp_WERT | unsigned int | - | 0.001000 | -32.767000 | SCRChk_rNOxDiffUsDsAvrg_mp | averaged normalised NOx deviation between NOx sensors before and after SCR | |
SCRChk_rNOxDsStkDelta_mp | 0x11C6 | STAT_SCRChk_rNOxDsStkDelta_mp_WERT | unsigned int | ppm | 0.025940 | -50.000000 | SCRChk_rNOxDsStkDelta_mp | Max. deviation of NOx sensor signal between peak start and peak phase | |
SCRChk_rNOxDiffAvrgMaxUs_mp | 0x11C7 | STAT_SCRChk_rNOxDiffAvrgMaxUs_mp_WERT | unsigned int | - | 0.001000 | -32.767000 | SCRChk_rNOxDiffAvrgMaxUs_mp | averaged normalised NOx deviation between model value and NOx sensor before SCR | |
RFC_mRdcAgFreeQnt | 0x11CA | STAT_RFC_mRdcAgFreeQnt_WERT | unsigned long | g | 1.000000 | 0.000000 | RFC_mRdcAgFreeQnt | Free volume in the active tank | |
RFC_mRdcAgReFlQnt | 0x11CB | STAT_RFC_mRdcAgReFlQnt_WERT | unsigned long | g | 1.000000 | 0.000000 | RFC_mRdcAgReFlQnt | Long-term pumping volume | |
RFC_stUPmpReFl | 0x11CE | STAT_RFC_stUPmpReFl_WERT | unsigned char | - | 1.000000 | 0.000000 | RFC_stUPmpReFl | real demand for pumping over | |
RFC_stReFl | 0x11CF | STAT_RFC_stReFl_WERT | unsigned char | - | 1.000000 | 0.000000 | RFC_stReFl | Status of the RFC state machine | |
UDC_rUTnkLvlFlt | 0x11D2 | STAT_UDC_rUTnkLvlFlt_WERT | unsigned int | % | 0.001526 | 0.000000 | UDC_rUTnkLvlFlt | Level of the active tank - filtered sensor value | |
UDC_rUPasTnkLvlFlt_mp | 0x11D4 | STAT_UDC_rUPasTnkLvlFlt_mp_WERT | unsigned int | % | 0.001526 | 0.000000 | UDC_rUPasTnkLvlFlt_mp | Filling level of the passive tank - filtered sensor value | |
UDC_mPasRdcAgRmn | 0x11D8 | STAT_UDC_mPasRdcAgRmn_WERT | unsigned int | g | 0.762951 | 0.000000 | UDC_mPasRdcAgRmn | Tank content of passive tank (2 bytes) | |
SCRCtl_stReFillActv | 0x11D9 | STAT_SCRCtl_stReFillActv_WERT | unsigned char | - | 1.000000 | 0.000000 | SCRCtl_stReFillActv | Detection status for AdBlue refilling and Wrong Medium detection | |
RFC_mRdcAgReFlQntQlDet | 0x11DA | STAT_RFC_mRdcAgReFlQntQlDet_WERT | unsigned long | g | 0.001000 | 0.000000 | RFC_mRdcAgReFlQntQlDet | Pump-over quantity since start of pump-over strategy (after night tank detection passive tank) | |
RFC_stRdcAgReFlQntQlDetElps | 0x11DC | STAT_RFC_stRdcAgReFlQntQlDetElps_WERT | unsigned char | - | 1.000000 | 0.000000 | RFC_stRdcAgReFlQntQlDetElps | Release of the quality monitoring after the end of the pumping strategy. | |
RFC_stReFlStrgy | 0x11DD | STAT_RFC_stReFlStrgy_WERT | unsigned char | - | 1.000000 | 0.000000 | RFC_stReFlStrgy | Status pumping strategy - large pumping quantities activated | |
SCRCtl_stQlDetEna | 0x11DE | STAT_SCRCtl_stQlDetEna_WERT | unsigned char | - | 1.000000 | 0.000000 | SCRCtl_stQlDetEna | Quality monitoring - status of night tank detection | |
SCRCtl_stRdcAgRmnQlDetEna | 0x11DF | STAT_SCRCtl_stRdcAgRmnQlDetEna_WERT | unsigned char | - | 1.000000 | 0.000000 | SCRCtl_stRdcAgRmnQlDetEna | Quality monitoring release condition | |
SCRCtl_rAvrgRdcAgConsPrMlg_mp | 0x11E0 | STAT_SCRCtl_rAvrgRdcAgConsPrMlg_mp_WERT | unsigned int | g/km | 0.001000 | 0.000000 | SCRCtl_rAvrgRdcAgConsPrMlg_mp | Average consumption - AdBlue | |
SCRCtl_lIntrvMlgRmn_mp | 0x11E2 | STAT_SCRCtl_lIntrvMlgRmn_mp_WERT | unsigned int | km | 0.038148 | 0.000000 | SCRCtl_lIntrvMlgRmn_mp | Driving distance of the current interval for remaining range calculation | |
SCRCtl_lRdcAgMlgRmn_mp | 0x11E3 | STAT_SCRCtl_lRdcAgMlgRmn_mp_WERT | unsigned int | km | 0.152590 | 0.000000 | SCRCtl_lRdcAgMlgRmn_mp | Remaining range before shutdown scenario starts | |
UHC_bHtrDlyBox_mp | 0x11E4 | STAT_UHC_bHtrDlyBox_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | UHC_bHtrDlyBox_mp | Condition - new circuit breaker detected | |
UHC_cndUHtrPLWp_mp | 0x11E5 | STAT_UHC_cndUHtrPLWp_mp_WERT | unsigned int | 1/Ohm | 0.000153 | 0.000000 | UHC_cndUHtrPLWp_mp | Currently valid conductance of the metering line heater | |
UHC_cndUHtrTnkWp_mp | 0x11E6 | STAT_UHC_cndUHtrTnkWp_mp_WERT | unsigned int | 1/Ohm | 0.000153 | 0.000000 | UHC_cndUHtrTnkWp_mp | Current conductance of the tank heater | |
UHC_stMonC1 | 0x11E7 | STAT_UHC_stMonC1_WERT | unsigned char | - | 1.000000 | 0.000000 | UHC_stMonC1 | Status C1 Monitor | |
UHC_stMonC2 | 0x11E8 | STAT_UHC_stMonC2_WERT | unsigned char | - | 1.000000 | 0.000000 | UHC_stMonC2 | Status C2 Monitor | |
SCRMod_facTempSCRTot_mp | 0x11EC | STAT_SCRMod_facTempSCRTot_mp_WERT | motorola float | - | 1.000000 | 0.000000 | SCRMod_facTempSCRTot_mp | Ageing factor SCR catalytic converter | |
SCRMod_facTempOxiTot_mp | 0x11ED | STAT_SCRMod_facTempOxiTot_mp_WERT | motorola float | - | 1.000000 | 0.000000 | SCRMod_facTempOxiTot_mp | Ageing factor oxicate | |
DStgy_cntAdapEFlEEP_mp | 0x11EE | STAT_DSTGY_CNTADAPEFLEEP_MP_WERT | unsigned int | - | 1.000000 | 0.000000 | DStgy_cntAdapEFlEEP_mp | Number of SCR quick plausibility checks | |
DStgy_cntAdapSlipOvrEEP_mp | 0x11EF | STAT_DSTGY_CNTADAPSLIPOVREEP_MP_WERT | unsigned int | - | 1.000000 | 0.000000 | DStgy_cntAdapSlipOvrEEP_mp | Number of SCR adaptations due to slip in thrust | |
DStgy_mNOxUsIntegEEP_mp | 0x11F0 | STAT_DSTGY_MNOXUSINTEGEEP_MP_WERT | unsigned int | g | 0.100000 | 0.000000 | DStgy_mNOxUsIntegEEP_mp | Cumulative NOx raw emission | |
DStgy_mSensNOxDsEEP_mp | 0x11F1 | STAT_DSTGY_MSENSNOXDSEEP_MP_WERT | unsigned int | g | 0.100000 | 0.000000 | DStgy_mSensNOxDsEEP_mp | Cumulative NOx emission after SCR via sensor | |
DStgy_tiDOSINGEEP_mp | 0x11F2 | STAT_DSTGY_TIDOSINGEEP_MP_WERT | unsigned int | s | 60.000000 | 0.000000 | DStgy_tiDOSINGEEP_mp | State duration SCR active | |
DStgy_tiNODOSINGEEP_mp | 0x11F3 | STAT_DSTGY_TINODOSINGEEP_MP_WERT | unsigned int | s | 60.000000 | 0.000000 | DStgy_tiNODOSINGEEP_mp | State duration SCR inactive | |
DStgy_tiPreCtlMode2EEP_mp | 0x11F4 | STAT_DSTGY_TIPRECTLMODE2EEP_MP_WERT | unsigned int | s | 60.000000 | 0.000000 | DStgy_tiPreCtlMode2EEP_mp | State duration SCR substitute metering strategy | |
DStgy_cntNOxCorrlnLo_mp | 0x11F5 | STAT_DStgy_cntNOxCorrlnLo_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | DStgy_cntNOxCorrlnLo_mp | DStgy_cntNOxCorrlnLo_mp | |
DStgy_cntNOxCorrlnHi_mp | 0x11F6 | STAT_DStgy_cntNOxCorrlnHi_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | DStgy_cntNOxCorrlnHi_mp | DStgy_cntNOxCorrlnHi_mp | |
DStgy_cntNOxCorrlnNoRslt_mp | 0x11F7 | STAT_DStgy_cntNOxCorrlnNoRslt_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | DStgy_cntNOxCorrlnNoRslt_mp | DStgy_cntNOxCorrlnNoRslt_mp | |
CSERS_stRlsMonRhu | 0x11F8 | STAT_CSERS_stRlsMonRhu_WERT | unsigned char | - | 1.000000 | 0.000000 | CSERS_stRlsMonRhu | CSERS status (RHU) | |
SCRMod_facEffSCRAge | 0x11F9 | STAT_SCRMod_facEffSCRAge_WERT | unsigned int | - | 0.000050 | 0.000000 | SCRMod_facEffSCRAge | Total ageing factor of the SCR catalyst | |
SCRCtl_dvolAvrgConsPrTi | 0x11FA | STAT_SCRCtl_dvolAvrgConsPrTi_WERT | unsigned int | l/h | 0.005000 | 0.000000 | SCRCtl_dvolAvrgConsPrTi | Average consumption of reducing agent in volume per time (PID85_BC) | |
SCRCtl_dvolDemConsPrTi | 0x11FB | STAT_SCRCtl_dvolDemConsPrTi_WERT | unsigned int | l/h | 0.005000 | 0.000000 | SCRCtl_dvolDemConsPrTi | Average amount of reducing agent requested in volume per time (PID85_DE) | |
SCRCtl_stIndSysAct | 0x11FC | STAT_SCRCtl_stIndSysAct_WERT | unsigned char | - | 1.000000 | 0.000000 | SCRCtl_stIndSysAct | Reasons for activating the inducement system in the current driving cycle (PID88_A) | |
SCRCtl_stIndcSysHist12 | 0x11FD | STAT_SCRCtl_stIndcSysHist12_WERT | unsigned char | - | 1.000000 | 0.000000 | SCRCtl_stIndcSysHist12 | Reasons for activating the inducement system for intervals 10k and 20k (PID88_B) | |
SCRCtl_stIndcSysHist34 | 0x11FE | STAT_SCRCtl_stIndcSysHist34_WERT | unsigned char | - | 1.000000 | 0.000000 | SCRCtl_stIndcSysHist34 | Reasons for activating the inducement system for intervals 30k and 40k (PID88_C) | |
SCRCtl_lIndcSysActvHist1 | 0x11FF | STAT_SCRCtl_lIndcSysActvHist1_WERT | unsigned int | km | 1.000000 | 0.000000 | SCRCtl_lIndcSysActvHist1 | km-counter with active inducement system in interval 10k (PID88_EN) | |
SCRCtl_lIndcSysActvHist2 | 0x1200 | STAT_SCRCtl_lIndcSysActvHist2_WERT | unsigned int | km | 1.000000 | 0.000000 | SCRCtl_lIndcSysActvHist2 | km counter with active inducement system at interval 20k (PID88_HI) | |
SCRCtl_lIndcSysActvHist3 | 0x1201 | STAT_SCRCtl_lIndcSysActvHist3_WERT | unsigned int | km | 1.000000 | 0.000000 | SCRCtl_lIndcSysActvHist3 | km counter with active inducement system in interval 30k (PID88_JK) | |
SCRCtl_lIndcSysActvHist4 | 0x1202 | STAT_SCRCtl_lIndcSysActvHist4_WERT | unsigned int | km | 1.000000 | 0.000000 | SCRCtl_lIndcSysActvHist4 | km counter with active inducement system in interval 40k (PID88_LM) | |
SCRCtl_lDst10K | 0x1203 | STAT_SCRCtl_lDst10K_WERT | unsigned int | km | 1.000000 | 0.000000 | SCRCtl_lDst10K | Total mileage of the vehicle related to the last 10000km (PID88_FG) | |
SCRFBC_facNOxCtl | 0x1204 | STAT_SCRFBC_facNOxCtl_WERT | unsigned int | - | 0.000153 | -5.000000 | SCRFBC_facNOxCtl | Control factor NOx controller | |
SCR_tSensUCatUsT | 0x1206 | STAT_SCR_tSensUCatUsT_WERT | unsigned int | degC | 0.031281 | -50.000000 | SCR_tSensUCatUsT | Sensor temperature before SCR catalytic converter | |
EngTrqPtd_stPthLim | 0x1326 | STAT_EngTrqPtd_stPthLim_WERT | unsigned char | - | 1.000000 | 0.000000 | EngTrqPtd_stPthLim | Status of the engine-side torque limitation from monitoring | |
EngTrqPtd_trqSpdG | 0x1328 | STAT_EngTrqPtd_trqSpdG_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | EngTrqPtd_trqSpdG | Permissible torque of the speed controller | |
EngTrqPtd_trqLim | 0x1329 | STAT_EngTrqPtd_trqLim_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | EngTrqPtd_trqLim | Limiting torque of the setpoint paths from monitoring | |
SyC_tiDrv | 0x1355 | STAT_SyC_tiDrv_WERT | unsigned long | ms | 10.000000 | 0.000000 | SyC_tiDrv | Time since reaching SYC_DRIVE state (from KL15 on) | |
SyC_stSub | 0x1356 | STAT_SyC_stSub_WERT | unsigned char | - | 1.000000 | 0.000000 | SyC_stSub | Current system/ECU sub-state | |
SyC_stMn | 0x1357 | STAT_SyC_stMn_WERT | unsigned char | - | 1.000000 | 0.000000 | SyC_stMn | Current system/ECU state | |
SyC_stPostDrv | 0x1358 | STAT_SyC_stPostDrv_WERT | unsigned char | - | 1.000000 | 0.000000 | SyC_stPostDrv | State of the PostDrive control | |
SyC_stPreDrv | 0x1359 | STAT_SyC_stPreDrv_WERT | unsigned char | - | 1.000000 | 0.000000 | SyC_stPreDrv | State of the PreDrive control | |
SyC_tiPostDrv | 0x135A | STAT_SyC_tiPostDrv_WERT | unsigned long | ms | 10.000000 | 0.000000 | SyC_tiPostDrv | Time since reaching SYC_POSTDRIVE state | |
SyC_tiPreDrv | 0x135B | STAT_SyC_tiPreDrv_WERT | unsigned long | ms | 10.000000 | 0.000000 | SyC_tiPreDrv | Time since reaching SYC_PREDRIVE state | |
SyC_stPreDrvWait_mp | 0x135C | STAT_SyC_stPreDrvWait_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | SyC_stPreDrvWait_mp | Source delay PreDrive | |
SyC_stPostDrvWait_mp | 0x135D | STAT_SyC_stPostDrvWait_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | SyC_stPostDrvWait_mp | Source of deceleration | |
NSCUs_rLam | 0x1388 | STAT_NSCUs_rLam_WERT | unsigned int | - | 0.000488 | 0.000000 | NSCUs_rLam | Lambda value before NSC | |
NSCDs_rLam | 0x1389 | STAT_NSCDs_rLam_WERT | unsigned int | - | 0.000488 | 0.000000 | NSCDs_rLam | Lambda value after NSC | |
NSCLd_mSOxTot_mp | 0x138A | STAT_NSCLd_mSOxTot_mp_WERT | unsigned int | g | 0.001000 | 0.000000 | NSCLd_mSOxTot_mp | Total sulphur mass | |
NSCRgn_mNOxTot_mp | 0x138C | STAT_NSCRgn_mNOxTot_mp_WERT | unsigned long | g | 0.000010 | 0.000000 | NSCRgn_mNOxTot_mp | Total NOx loading mass of the NSC | |
NSCMon_mRdcSlip_mp | 0x138E | STAT_NSCMon_mRdcSlip_mp_WERT | unsigned int | g | 0.001000 | 0.000000 | NSCMon_mRdcSlip_mp | Reducing agent slip since last NSC regeneration | |
NSCMon_mRdcCons_mp | 0x138F | STAT_NSCMon_mRdcCons_mp_WERT | unsigned int | g | 0.001000 | 0.000000 | NSCMon_mRdcCons_mp | Reducing agent consumption since last NSC regeneration | |
NSCRgn_tiHtg | 0x1391 | STAT_NSCRgn_tiHtg_WERT | unsigned long | s | 0.000100 | 0.000000 | NSCRgn_tiHtg | Time in heating mode | |
NSCRgn_tiDSOx | 0x1393 | STAT_NSCRgn_tiDSOx_WERT | unsigned long | s | 0.000100 | 0.000000 | NSCRgn_tiDSOx | Time in DSOx operation | |
NSCRgn_tiDNOx | 0x1395 | STAT_NSCRgn_tiDNOx_WERT | unsigned long | s | 0.000100 | 0.000000 | NSCRgn_tiDNOx | Time of operation in DeNOx mode | |
NSCLd_mNOxFld_0 | 0x1397 | STAT_NSCLd_mNOxFld_0_WERT | unsigned long | g | 0.000015 | 0.000000 | NSCLd_mNOxFld_0 | NOx loading of the NSC (from model) 0 | |
NSCLd_mNOxFld_1 | 0x1398 | STAT_NSCLd_mNOxFld_1_WERT | unsigned long | g | 0.000015 | 0.000000 | NSCLd_mNOxFld_1 | NOx loading of the NSC (from model) 1 | |
NSCLd_mNOxFld_2 | 0x1399 | STAT_NSCLd_mNOxFld_2_WERT | unsigned long | g | 0.000015 | 0.000000 | NSCLd_mNOxFld_2 | NOx loading of the NSC (from model) 2 | |
NSCLd_mSOxFld_0 | 0x139A | STAT_NSCLd_mSOxFld_0_WERT | unsigned long | g | 0.000015 | 0.000000 | NSCLd_mSOxFld_0 | SOx load of NSC (from model) 0 | |
NSCLd_mSOxFld_1 | 0x139B | STAT_NSCLd_mSOxFld_1_WERT | unsigned long | g | 0.000015 | 0.000000 | NSCLd_mSOxFld_1 | SOx loading of the NSC (from model) 1 | |
NSCLd_mSOxFld_2 | 0x139C | STAT_NSCLd_mSOxFld_2_WERT | unsigned long | g | 0.000015 | 0.000000 | NSCLd_mSOxFld_2 | SOx loading of the NSC (from model) 2 | |
AirSys_dmAirMinSoftShOff | 0x13BA | STAT_AirSys_dmAirMinSoftShOff_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AirSys_dmAirMinSoftShOff | AirSys_dmAirMinSoftShOff | |
AirSys_dmIndAirRef01 | 0x13BB | STAT_AirSys_dmIndAirRef01_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AirSys_dmIndAirRef01 | AirSys_dmIndAirRef01 | |
AirSys_dmIndAirRef02 | 0x13BC | STAT_AirSys_dmIndAirRef02_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AirSys_dmIndAirRef02 | AirSys_dmIndAirRef02 | |
AirSys_dmIndAirRef03 | 0x13BD | STAT_AirSys_dmIndAirRef03_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AirSys_dmIndAirRef03 | AirSys_dmIndAirRef03 | |
AirSys_dmPlsCorr01 | 0x13BE | STAT_AirSys_dmPlsCorr01_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AirSys_dmPlsCorr01 | AirSys_dmPlsCorr01 | |
AirSys_dmPlsCorr02 | 0x13BF | STAT_AirSys_dmPlsCorr02_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AirSys_dmPlsCorr02 | AirSys_dmPlsCorr02 | |
AirSys_dmPlsCorr03 | 0x13C0 | STAT_AirSys_dmPlsCorr03_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AirSys_dmPlsCorr03 | AirSys_dmPlsCorr03 | |
AirSys_dmPlsCorr04 | 0x13C1 | STAT_AirSys_dmPlsCorr04_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AirSys_dmPlsCorr04 | AirSys_dmPlsCorr04 | |
AirSys_dmPlsCorr05 | 0x13C2 | STAT_AirSys_dmPlsCorr05_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AirSys_dmPlsCorr05 | AirSys_dmPlsCorr05 | |
AirSys_dmPlsCorr06 | 0x13C3 | STAT_AirSys_dmPlsCorr06_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AirSys_dmPlsCorr06 | AirSys_dmPlsCorr06 | |
AirSys_dmPlsCorr07 | 0x13C4 | STAT_AirSys_dmPlsCorr07_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AirSys_dmPlsCorr07 | AirSys_dmPlsCorr07 | |
AirSys_dmPlsCorr08 | 0x13C5 | STAT_AirSys_dmPlsCorr08_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AirSys_dmPlsCorr08 | AirSys_dmPlsCorr08 | |
AirSys_dmPlsCorr09 | 0x13C6 | STAT_AirSys_dmPlsCorr09_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AirSys_dmPlsCorr09 | AirSys_dmPlsCorr09 | |
AirSys_dmPlsCorr10 | 0x13C7 | STAT_AirSys_dmPlsCorr10_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AirSys_dmPlsCorr10 | AirSys_dmPlsCorr10 | |
AirSys_dmPlsCorr11 | 0x13C8 | STAT_AirSys_dmPlsCorr11_WERT | unsigned int | kg/h | 0.100000 | 0.000000 | AirSys_dmPlsCorr11 | AirSys_dmPlsCorr11 | |
AirSys_pMeanDesVal | 0x13C9 | STAT_AirSys_pMeanDesVal_WERT | unsigned int | hPa | 1.000000 | 0.000000 | AirSys_pMeanDesVal | AirSys_pMeanDesVal | |
AirSys_pMeanIntkVUs | 0x13CA | STAT_AirSys_pMeanIntkVUs_WERT | unsigned int | hPa | 1.000000 | 0.000000 | AirSys_pMeanIntkVUs | AirSys_pMeanIntkVUs | |
AirSys_rP22P0R01 | 0x13CB | STAT_AirSys_rP22P0R01_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R01 | AirSys_rP22P0R01 | |
AirSys_rP22P0R02 | 0x13CC | STAT_AirSys_rP22P0R02_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R02 | AirSys_rP22P0R02 | |
AirSys_rP22P0R03 | 0x13CD | STAT_AirSys_rP22P0R03_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R03 | AirSys_rP22P0R03 | |
AirSys_rP22P0R04 | 0x13CE | STAT_AirSys_rP22P0R04_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R04 | AirSys_rP22P0R04 | |
AirSys_rP22P0R05 | 0x13CF | STAT_AirSys_rP22P0R05_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R05 | AirSys_rP22P0R05 | |
AirSys_rP22P0R06 | 0x13D0 | STAT_AirSys_rP22P0R06_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R06 | AirSys_rP22P0R06 | |
AirSys_rP22P0R07 | 0x13D1 | STAT_AirSys_rP22P0R07_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R07 | AirSys_rP22P0R07 | |
AirSys_rP22P0R08 | 0x13D2 | STAT_AirSys_rP22P0R08_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R08 | AirSys_rP22P0R08 | |
AirSys_rP22P0R09 | 0x13D3 | STAT_AirSys_rP22P0R09_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R09 | AirSys_rP22P0R09 | |
AirSys_rP22P0R10 | 0x13D4 | STAT_AirSys_rP22P0R10_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R10 | AirSys_rP22P0R10 | |
AirSys_rP22P0R11 | 0x13D5 | STAT_AirSys_rP22P0R11_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R11 | AirSys_rP22P0R11 | |
AirSys_rP22P0R12 | 0x13D6 | STAT_AirSys_rP22P0R12_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R12 | AirSys_rP22P0R12 | |
AirSys_rP22P0R13 | 0x13D7 | STAT_AirSys_rP22P0R13_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R13 | AirSys_rP22P0R13 | |
AirSys_rP22P0R14 | 0x13D8 | STAT_AirSys_rP22P0R14_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R14 | AirSys_rP22P0R14 | |
AirSys_rP22P0R15 | 0x13D9 | STAT_AirSys_rP22P0R15_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R15 | AirSys_rP22P0R15 | |
AirSys_rP22P0R16 | 0x13DA | STAT_AirSys_rP22P0R16_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R16 | AirSys_rP22P0R16 | |
AirSys_rP22P0R17 | 0x13DB | STAT_AirSys_rP22P0R17_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R17 | AirSys_rP22P0R17 | |
AirSys_rP22P0R18 | 0x13DC | STAT_AirSys_rP22P0R18_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R18 | AirSys_rP22P0R18 | |
AirSys_rP22P0R19 | 0x13DD | STAT_AirSys_rP22P0R19_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R19 | AirSys_rP22P0R19 | |
AirSys_rP22P0R20 | 0x13DE | STAT_AirSys_rP22P0R20_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R20 | AirSys_rP22P0R20 | |
AirSys_rP22P0R21 | 0x13DF | STAT_AirSys_rP22P0R21_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP22P0R21 | AirSys_rP22P0R21 | |
AirSys_rP31P40R01 | 0x13E0 | STAT_AirSys_rP31P40R01_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R01 | AirSys_rP31P40R01 | |
AirSys_rP31P40R02 | 0x13E1 | STAT_AirSys_rP31P40R02_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R02 | AirSys_rP31P40R02 | |
AirSys_rP31P40R03 | 0x13E2 | STAT_AirSys_rP31P40R03_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R03 | AirSys_rP31P40R03 | |
AirSys_rP31P40R04 | 0x13E3 | STAT_AirSys_rP31P40R04_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R04 | AirSys_rP31P40R04 | |
AirSys_rP31P40R05 | 0x13E4 | STAT_AirSys_rP31P40R05_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R05 | AirSys_rP31P40R05 | |
AirSys_rP31P40R06 | 0x13E5 | STAT_AirSys_rP31P40R06_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R06 | AirSys_rP31P40R06 | |
AirSys_rP31P40R07 | 0x13E6 | STAT_AirSys_rP31P40R07_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R07 | AirSys_rP31P40R07 | |
AirSys_rP31P40R08 | 0x13E7 | STAT_AirSys_rP31P40R08_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R08 | AirSys_rP31P40R08 | |
AirSys_rP31P40R09 | 0x13E8 | STAT_AirSys_rP31P40R09_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R09 | AirSys_rP31P40R09 | |
AirSys_rP31P40R10 | 0x13E9 | STAT_AirSys_rP31P40R10_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R10 | AirSys_rP31P40R10 | |
AirSys_rP31P40R11 | 0x13EA | STAT_AirSys_rP31P40R11_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R11 | AirSys_rP31P40R11 | |
AirSys_rP31P40R14 | 0x13ED | STAT_AirSys_rP31P40R14_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R14 | AirSys_rP31P40R14 | |
AirSys_rP31P40R15 | 0x13EE | STAT_AirSys_rP31P40R15_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R15 | AirSys_rP31P40R15 | |
AirSys_rP31P40R16 | 0x13EF | STAT_AirSys_rP31P40R16_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R16 | AirSys_rP31P40R16 | |
AirSys_rP31P40R18 | 0x13F1 | STAT_AirSys_rP31P40R18_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R18 | AirSys_rP31P40R18 | |
AirSys_rP31P40R19 | 0x13F2 | STAT_AirSys_rP31P40R19_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R19 | AirSys_rP31P40R19 | |
AirSys_rP31P40R20 | 0x13F3 | STAT_AirSys_rP31P40R20_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R20 | AirSys_rP31P40R20 | |
AirSys_rP31P40R21 | 0x13F4 | STAT_AirSys_rP31P40R21_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rP31P40R21 | AirSys_rP31P40R21 | |
AirSys_stGetAbrtReasonNG | 0x13F5 | STAT_AirSys_stGetAbrtReasonNG_WERT | unsigned char | - | 1.000000 | 0.000000 | AirSys_stGetAbrtReasonNG | AirSys_stGetAbrtReasonNG | |
AirSys_stGetStNG | 0x13F6 | STAT_AirSys_stGetStNG_WERT | unsigned char | - | 1.000000 | 0.000000 | AirSys_stGetStNG | AirSys_stGetStNG | |
AirSys_stGetStrtPrmsNG | 0x13F7 | STAT_AirSys_stGetStrtPrmsNG_WERT | unsigned int | - | 1.000000 | 0.000000 | AirSys_stGetStrtPrmsNG | AirSys_stGetStrtPrmsNG | |
AirSys_stResult1 | 0x13F8 | STAT_AirSys_stResult1_WERT | unsigned int | - | 1.000000 | 0.000000 | AirSys_stResult1 | AirSys_stResult1 | |
AirSys_stResult2 | 0x13F9 | STAT_AirSys_stResult2_WERT | unsigned int | - | 1.000000 | 0.000000 | AirSys_stResult2 | AirSys_stResult2 | |
AirSys_stResult3 | 0x13FA | STAT_AirSys_stResult3_WERT | unsigned int | - | 1.000000 | 0.000000 | AirSys_stResult3 | AirSys_stResult3 | |
AirSys_stStage1 | 0x13FB | STAT_AirSys_stStage1_WERT | unsigned int | - | 1.000000 | 0.000000 | AirSys_stStage1 | AirSys_stStage1 | |
AirSys_stStage2 | 0x13FC | STAT_AirSys_stStage2_WERT | unsigned int | - | 1.000000 | 0.000000 | AirSys_stStage2 | AirSys_stStage2 | |
AirSys_stStage3 | 0x13FD | STAT_AirSys_stStage3_WERT | unsigned int | - | 1.000000 | 0.000000 | AirSys_stStage3 | AirSys_stStage3 | |
AirSys_stStateSysTstNG | 0x13FE | STAT_AirSys_stStateSysTstNG_WERT | unsigned char | - | 1.000000 | 0.000000 | AirSys_stStateSysTstNG | AirSys_stStateSysTstNG | |
AirSys_stSubStateSysTstNG | 0x13FF | STAT_AirSys_stSubStateSysTstNG_WERT | unsigned char | - | 1.000000 | 0.000000 | AirSys_stSubStateSysTstNG | AirSys_stSubStateSysTstNG | |
AirSys_tEGRClg01 | 0x1400 | STAT_AirSys_tEGRClg01_WERT | unsigned int | degC | 0.009995 | -55.000000 | AirSys_tEGRClg01 | AirSys_tEGRClg01 | |
AirSys_tEGRClg02 | 0x1401 | STAT_AirSys_tEGRClg02_WERT | unsigned int | degC | 0.009995 | -55.000000 | AirSys_tEGRClg02 | AirSys_tEGRClg02 | |
AirSys_tiSoftShOff1 | 0x1402 | STAT_AirSys_tiSoftShOff1_WERT | unsigned long | ms | 10.000000 | 0.000000 | AirSys_tiSoftShOff1 | AirSys_tiSoftShOff1 | |
AirSys_tiSoftShOff2 | 0x1403 | STAT_AirSys_tiSoftShOff2_WERT | unsigned long | ms | 10.000000 | 0.000000 | AirSys_tiSoftShOff2 | AirSys_tiSoftShOff2 | |
AirSys_tLPEGRClg01 | 0x1404 | STAT_AirSys_tLPEGRClg01_WERT | unsigned int | degC | 0.009995 | -55.000000 | AirSys_tLPEGRClg01 | AirSys_tLPEGRClg01 | |
AirSys_tLPEGRClg02 | 0x1405 | STAT_AirSys_tLPEGRClg02_WERT | unsigned int | degC | 0.009995 | -55.000000 | AirSys_tLPEGRClg02 | AirSys_tLPEGRClg02 | |
AirSys_rRED11_mp | 0x141E | STAT_AirSys_rRED11_mp_WERT | unsigned int | - | 0.012512 | -410.000000 | AirSys_rRED11_mp | Result of the LMS test for calculation RED11 | |
AirSys_rRED12_mp | 0x141F | STAT_AirSys_rRED12_mp_WERT | unsigned int | - | 0.012512 | -410.000000 | AirSys_rRED12_mp | Result of the LMS test for calculation RED12 | |
AirSys_rRED13_mp | 0x1420 | STAT_AirSys_rRED13_mp_WERT | unsigned int | - | 0.012512 | -410.000000 | AirSys_rRED13_mp | Result of the LMS test for calculation RED13 | |
AirSys_rRED21_mp | 0x1421 | STAT_AirSys_rRED21_mp_WERT | unsigned int | - | 0.012512 | -410.000000 | AirSys_rRED21_mp | Result of the LMS test for calculation RED21 | |
AirSys_rRED22_mp | 0x1422 | STAT_AirSys_rRED22_mp_WERT | unsigned int | - | 0.012512 | -410.000000 | AirSys_rRED22_mp | Result of the LMS test for calculation RED22 | |
AirSys_dRED1_mp | 0x1423 | STAT_AirSys_dRED1_mp_WERT | unsigned int | - | 0.012512 | -410.000000 | AirSys_dRED1_mp | Result of the LMS test calculation for dRED1 | |
AirSys_dRED2_mp | 0x1424 | STAT_AirSys_dRED2_mp_WERT | unsigned int | - | 0.012512 | -410.000000 | AirSys_dRED2_mp | Result of the LMS test calculation for dRED2 | |
AirSys_rDIFF1_mp | 0x1425 | STAT_AirSys_rDIFF1_mp_WERT | unsigned int | - | 0.012512 | -410.000000 | AirSys_rDIFF1_mp | Result of the LMS test for calculation DIFF1 | |
AirSys_rDIFF2_mp | 0x1426 | STAT_AirSys_rDIFF2_mp_WERT | unsigned int | - | 0.012512 | -410.000000 | AirSys_rDIFF2_mp | Result of the LMS test for calculation DIFF2 | |
AirSys_mLM10_mp | 0x1427 | STAT_AirSys_mLM10_mp_WERT | unsigned long | kg/h | 0.100000 | 0.000000 | AirSys_mLM10_mp | Result of LMS test calculation for air mass base mean LM10 at <LDS off> | |
AirSys_mLM11_mp | 0x1428 | STAT_AirSys_mLM11_mp_WERT | unsigned long | kg/h | 0.100000 | 0.000000 | AirSys_mLM11_mp | Result of the LMS test calculation for air mass mean value LM11 at <LDS off>. | |
AirSys_mLM12_mp | 0x1429 | STAT_AirSys_mLM12_mp_WERT | unsigned long | kg/h | 0.100000 | 0.000000 | AirSys_mLM12_mp | Result of the LMS test calculation for air mass average LM12 at <LDS off>. | |
AirSys_mLM13_mp | 0x142A | STAT_AirSys_mLM13_mp_WERT | unsigned long | kg/h | 0.100000 | 0.000000 | AirSys_mLM13_mp | Result of the LMS test calculation for air mass average LM13 at <LDS off>. | |
AirSys_mLM20_mp | 0x142B | STAT_AirSys_mLM20_mp_WERT | unsigned long | kg/h | 0.100000 | 0.000000 | AirSys_mLM20_mp | Result of the LMS test calculation for air mass base mean value LM20 at <LDS on>. | |
AirSys_mLM21_mp | 0x142C | STAT_AirSys_mLM21_mp_WERT | unsigned long | kg/h | 0.100000 | 0.000000 | AirSys_mLM21_mp | Result of the LMS test calculation for air mass mean value LM21 at <LDS on>. | |
AirSys_mLM22_mp | 0x142D | STAT_AirSys_mLM22_mp_WERT | unsigned long | kg/h | 0.100000 | 0.000000 | AirSys_mLM22_mp | Result of the LMS test calculation for air mass average LM22 at <LDS on>. | |
AirSys_ststateSysTst_mp | 0x142E | STAT_AirSys_ststateSysTst_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | AirSys_ststateSysTst_mp | Status of the LMS test (internal variable) | |
AirSys_stsubstateSysTst_mp | 0x142F | STAT_AirSys_stsubstateSysTst_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | AirSys_stsubstateSysTst_mp | Sub-status of the LMS test (internal variable) | |
AirSys_p21max1_mp | 0x1430 | STAT_AirSys_p21max1_mp_WERT | unsigned int | hPa | 1.000000 | 0.000000 | AirSys_p21max1_mp | Result of the LMS test calculation for boost pressure after waiting time T_WAIT_1 | |
AirSys_p21max2_mp | 0x1431 | STAT_AirSys_p21max2_mp_WERT | unsigned int | hPa | 1.000000 | 0.000000 | AirSys_p21max2_mp | Result of the LMS test calculation for boost pressure after waiting time T_WAIT_2 | |
AirSys_mLHFM1_mp | 0x1432 | STAT_AirSys_mLHFM1_mp_WERT | unsigned long | kg/h | 0.100000 | 0.000000 | AirSys_mLHFM1_mp | Result of the LMS test calculation for the mean value of the air mass flow at high speed | |
AirSys_mLHFM2_mp | 0x1433 | STAT_AirSys_mLHFM2_mp_WERT | unsigned long | kg/h | 0.100000 | 0.000000 | AirSys_mLHFM2_mp | Result of the LMS test calculation for the mean value of the air mass flow at idling speed | |
AirSys_mLBer1_mp | 0x1434 | STAT_AirSys_mLBer1_mp_WERT | unsigned long | kg/h | 0.100000 | 0.000000 | AirSys_mLBer1_mp | Result of the LMS test calculation for reference air mass flow into the engine at high speed | |
AirSys_mLBer2_mp | 0x1435 | STAT_AirSys_mLBer2_mp_WERT | unsigned long | kg/h | 0.100000 | 0.000000 | AirSys_mLBer2_mp | Result of the LMS test calculation for reference air mass flow into the engine at idling speed | |
AirSys_rLverh1_mp | 0x1436 | STAT_AirSys_rLverh1_mp_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rLverh1_mp | Result of the LMS test for HFM value in the upper air mass range | |
AirSys_rLverh2_mp | 0x1437 | STAT_AirSys_rLverh2_mp_WERT | unsigned int | - | 0.010000 | 0.000000 | AirSys_rLverh2_mp | Result of LMS test for HFM value in idling air mass range | |
AirSys_GetAbrtReason_mp | 0x1438 | STAT_AirSys_GetAbrtReason_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | AirSys_GetAbrtReason_mp | Reason for aborting the test (for the ETC) | |
AirSys_GetSt_mp | 0x1439 | STAT_AirSys_GetSt_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | AirSys_GetSt_mp | Current status of the test (for the ETC) | |
AirSys_stSysTst | 0x143A | STAT_AirSys_stSysTst_WERT | unsigned long | - | 1.000000 | 0.000000 | AirSys_stSysTst | Status and results of the air mass system test | |
EBxFan_stPs | 0x1446 | STAT_EBxFan_stPs_WERT | unsigned char | - | 1.000000 | 0.000000 | EBxFan_stPs | Power stage output for SG enclosure fan | |
ETClb_pRailSet_0 | 0x1450 | STAT_ETClb_pRailSet_0_WERT | unsigned int | bar | 0.100000 | 0.000000 | ETClb_pRailSet_0 | Status of the drive duration calibration 0 | |
ETClb_pRailSet_1 | 0x1451 | STAT_ETClb_pRailSet_1_WERT | unsigned int | bar | 0.100000 | 0.000000 | ETClb_pRailSet_1 | Control duration calibration status 1 | |
ETClb_pRailSet_2 | 0x1452 | STAT_ETClb_pRailSet_2_WERT | unsigned int | bar | 0.100000 | 0.000000 | ETClb_pRailSet_2 | Status of drive duration calibration 2 | |
ETClb_tiETMax_0 | 0x1453 | STAT_ETClb_tiETMax0_WERT | unsigned int | us | 0.400000 | 0.000000 | ETClb_tiETMax_0 | Maximum actuation duration of actuation duration calibration at rail pressure calibration point 0 | |
ETClb_tiETMax_1 | 0x1454 | STAT_ETClb_tiETMax1_WERT | unsigned int | us | 0.400000 | 0.000000 | ETClb_tiETMax_1 | Maximum control duration of the control duration calibration at the rail pressure calibration point 1 | |
ETClb_tiETMax_2 | 0x1455 | STAT_ETClb_tiETMax2_WERT | unsigned int | us | 0.400000 | 0.000000 | ETClb_tiETMax_2 | Maximum actuation duration of actuation duration calibration at rail pressure calibration point 2 | |
INMKZ400 | 0x1456 | STAT_ANSTEUERDAUER_AKTUELLER_ZYLINDER_400BAR_WERT | unsigned int | us | 0.400000 | 0.000000 | ETClb_tiETMin_0 | Minimum control duration of the control duration calibration at the rail pressure calibration point 0 | |
INMKZ700 | 0x1457 | STAT_ANSTEUERDAUER_AKTUELLER_ZYLINDER_700BAR_WERT | unsigned int | us | 0.400000 | 0.000000 | ETClb_tiETMin_1 | Minimum actuation duration of actuation duration calibration at rail pressure calibration point 1 | |
INMKZ1000 | 0x1458 | STAT_ANSTEUERDAUER_AKTUELLER_ZYLINDER_1000BAR_WERT | unsigned int | us | 0.400000 | 0.000000 | ETClb_tiETMin_2 | Minimum actuation duration of actuation duration calibration at rail pressure calibration point 2 | |
ETClb_tiETAvrg_0 | 0x1459 | STAT_ETClb_tiETAvrg0_WERT | unsigned int | us | 0.400000 | 0.000000 | ETClb_tiETAvrg_0 | Average actuation duration of the actuation duration calibration at the rail pressure calibration point 0 | |
ETClb_tiETAvrg_1 | 0x145A | STAT_ETClb_tiETAvrg1_WERT | unsigned int | us | 0.400000 | 0.000000 | ETClb_tiETAvrg_1 | Average actuation duration of actuation duration calibration at rail pressure calibration point 1 | |
ETClb_tiETAvrg_2 | 0x145B | STAT_ETClb_tiETAvrg2_WERT | unsigned int | us | 0.400000 | 0.000000 | ETClb_tiETAvrg_2 | Average control duration of the control duration calibration at rail pressure calibration point 2 | |
ISNFR | 0x145C | STAT_NULLMENGENADAPTION_STATUS_FREIGABEN_WERT | unsigned char | - | 1.000000 | 0.000000 | ETClb_stCor | Status display of the releases for the actuation duration calibration (1 byte) | |
ISNFZ | 0x145D | STAT_NULLMENGENADAPTION_STATUS_FREIGABEN_WERT | unsigned char | - | 1.000000 | 0.000000 | ETClb_stRlsCylCor_mp | Cylinder-specific release for the actuation duration calibration (1 byte) | |
INMKL0 | 0x145E | STAT_NMK_LERNZYKLUSZAEHLER_0_WERT | unsigned int | - | 1.000000 | 0.000000 | ETClb_ctLrn_mp_0 | Learning cycle counter of the actuation duration calibration for rail pressure calibration point 0 | |
INMKL1 | 0x145F | STAT_NMK_LERNZYKLUSZAEHLER_1_WERT | unsigned int | - | 1.000000 | 0.000000 | ETClb_ctLrn_mp_1 | Learning cycle counter of the actuation duration calibration for rail pressure calibration point 1 | |
INMKL2 | 0x1460 | STAT_NMK_LERNZYKLUSZAEHLER_2_WERT | unsigned int | - | 1.000000 | 0.000000 | ETClb_ctLrn_mp_2 | Learning cycle counter of the actuation duration calibration for rail pressure calibration point 2 | |
INMK00 | 0x1461 | STAT_ANSTEUERDAUER_KORR_PIL0_ZYL1_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt0_mp_0 | Control duration difference of the control duration calibration for cylinder 1 at rail pressure calibration point 0 | |
INMK01 | 0x1462 | STAT_ANSTEUERDAUER_KORR_PIL0_ZYL2_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt0_mp_1 | Control duration difference of the control duration calibration for cylinder 2 at rail pressure calibration point 0 | |
INMK02 | 0x1463 | STAT_ANSTEUERDAUER_KORR_PIL0_ZYL3_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt0_mp_2 | Control duration difference of the control duration calibration for cylinder 3 at the rail pressure calibration point 0 | |
INMK03 | 0x1464 | STAT_ANSTEUERDAUER_KORR_PIL0_ZYL4_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt0_mp_3 | Control duration difference of the control duration calibration for cylinder 4 at the rail pressure calibration point 0 | |
INMK04 | 0x1465 | STAT_ANSTEUERDAUER_KORR_PIL0_ZYL5_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt0_mp_4 | Control duration difference of the control duration calibration for cylinder 5 at the rail pressure calibration point 0 | |
INMK05 | 0x1466 | STAT_ANSTEUERDAUER_KORR_PIL0_ZYL6_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt0_mp_5 | Control duration difference of the control duration calibration for cylinder 6 at the rail pressure calibration point 0 | |
INMK10 | 0x1467 | STAT_ANSTEUERDAUER_KORR_PIL1_ZYL1_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt1_mp_0 | Control duration difference of the control duration calibration for cylinder 1 at rail pressure calibration point 1 | |
INMK11 | 0x1468 | STAT_ANSTEUERDAUER_KORR_PIL1_ZYL2_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt1_mp_1 | Control duration difference of the control duration calibration for cylinder 2 at rail pressure calibration point 1 | |
INMK12 | 0x1469 | STAT_ANSTEUERDAUER_KORR_PIL1_ZYL3_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt1_mp_2 | Control duration difference of the control duration calibration for cylinder 3 at rail pressure calibration point 1 | |
INMK13 | 0x146A | STAT_ANSTEUERDAUER_KORR_PIL1_ZYL4_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt1_mp_3 | Control duration difference of the control duration calibration for cylinder 4 at rail pressure calibration point 1 | |
INMK14 | 0x146B | STAT_ANSTEUERDAUER_KORR_PIL1_ZYL5_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt1_mp_4 | Actuation duration difference of the actuation duration calibration for cylinder 5 at rail pressure calibration point 1 | |
INMK15 | 0x146C | STAT_ANSTEUERDAUER_KORR_PIL1_ZYL6_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt1_mp_5 | Actuation duration difference of the actuation duration calibration for cylinder 6 at rail pressure calibration point 1 | |
INMK20 | 0x146D | STAT_ANSTEUERDAUER_KORR_PIL2_ZYL1_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt2_mp_0 | Control duration difference of the control duration calibration for cylinder 1 at rail pressure calibration point 2 | |
INMK21 | 0x146E | STAT_ANSTEUERDAUER_KORR_PIL2_ZYL2_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt2_mp_1 | Control duration difference of the control duration calibration for cylinder 2 at rail pressure calibration point 2 | |
INMK22 | 0x146F | STAT_ANSTEUERDAUER_KORR_PIL2_ZYL3_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt2_mp_2 | Control duration difference of the control duration calibration for cylinder 3 at rail pressure calibration point 2 | |
INMK23 | 0x1470 | STAT_ANSTEUERDAUER_KORR_PIL2_ZYL4_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt2_mp_3 | Control duration difference of the control duration calibration for cylinder 4 at rail pressure calibration point 2 | |
INMK24 | 0x1471 | STAT_ANSTEUERDAUER_KORR_PIL2_ZYL5_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt2_mp_4 | Control duration difference of the control duration calibration for cylinder 5 at rail pressure calibration point 2 | |
INMK25 | 0x1472 | STAT_ANSTEUERDAUER_KORR_PIL2_ZYL6_WERT | unsigned int | us | 0.152590 | -5000.000000 | ETClb_dtiETFlt2_mp_5 | Control duration difference of the control duration calibration for cylinder 6 at rail pressure calibration point 2 | |
ETClb_tiETCor2_mp_0 | 0x147F | STAT_ETClb_tiETCor2_mp_0_WERT | unsigned int | us | 0.400000 | 0.000000 | ETClb_tiETCor2_mp_0 | Control duration correction value of the control duration calibration for the rail pressure calibration point 2 0 | |
ETClb_tiETCor2_mp_1 | 0x1480 | STAT_ETClb_tiETCor2_mp_1_WERT | unsigned int | us | 0.400000 | 0.000000 | ETClb_tiETCor2_mp_1 | Control duration correction value of the control duration calibration for the rail pressure calibration point 2 1 | |
ETClb_tiETCor2_mp_2 | 0x1481 | STAT_ETClb_tiETCor2_mp_2_WERT | unsigned int | us | 0.400000 | 0.000000 | ETClb_tiETCor2_mp_2 | Control duration correction value of the control duration calibration for the rail pressure calibration point 2 2 | |
ETClb_tiETCor2_mp_3 | 0x1482 | STAT_ETClb_tiETCor2_mp_3_WERT | unsigned int | us | 0.400000 | 0.000000 | ETClb_tiETCor2_mp_3 | Control duration correction value of the control duration calibration for the rail pressure calibration point 2 3 | |
ETClb_tiETCor2_mp_4 | 0x1483 | STAT_ETClb_tiETCor2_mp_4_WERT | unsigned int | us | 0.400000 | 0.000000 | ETClb_tiETCor2_mp_4 | Control duration correction value of the control duration calibration for the rail pressure calibration point 2 4 | |
ETClb_tiETCor2_mp_5 | 0x1484 | STAT_ETClb_tiETCor2_mp_5_WERT | unsigned int | us | 0.400000 | 0.000000 | ETClb_tiETCor2_mp_5 | Control duration correction value of the control duration calibration for the rail pressure calibration point 2 5 | |
INZZ1 | 0x1496 | STAT_MOTORDREHZAHL_ZYLINDERSPEZIFISCH_ZYL1_WERT | unsigned int | rpm | 0.091554 | 0.000000 | IVPlaus_nCyl_0 | Cylinder-specific speed for cylinder 1 (in order) | |
INZZ2 | 0x1497 | STAT_MOTORDREHZAHL_ZYLINDERSPEZIFISCH_ZYL2_WERT | unsigned int | rpm | 0.091554 | 0.000000 | IVPlaus_nCyl_1 | Cylinder-specific speed for cylinder 2 (in order) | |
INZZ3 | 0x1498 | STAT_MOTORDREHZAHL_ZYLINDERSPEZIFISCH_ZYL3_WERT | unsigned int | rpm | 0.091554 | 0.000000 | IVPlaus_nCyl_2 | Cylinder-specific speed for cylinder 3 (in order) | |
INZZ4 | 0x1499 | STAT_MOTORDREHZAHL_ZYLINDERSPEZIFISCH_ZYL4_WERT | unsigned int | rpm | 0.091554 | 0.000000 | IVPlaus_nCyl_3 | Cylinder specific speed for cylinder 4 (in order) | |
INZZ5 | 0x149A | STAT_MOTORDREHZAHL_ZYLINDERSPEZIFISCH_ZYL5_WERT | unsigned int | rpm | 0.091554 | 0.000000 | IVPlaus_nCyl_4 | Cylinder specific speed for cylinder 5 (in order) | |
INZZ6 | 0x149B | STAT_MOTORDREHZAHL_ZYLINDERSPEZIFISCH_ZYL6_WERT | unsigned int | rpm | 0.091554 | 0.000000 | IVPlaus_nCyl_5 | Cylinder specific speed for cylinder 6 (in order) | |
IMKZ1 | 0x149C | STAT_MENGENKORREKTUR_ZYLINDERSPEZIFISCH_ZYL1_WERT | unsigned int | mg/hub | 0.003052 | -100.000000 | IVPlaus_qFBCCyl_0 | Cylinder-specific FBC compensation quantity for cylinder 1 (in order) | |
IMKZ2 | 0x149D | STAT_MENGENKORREKTUR_ZYLINDERSPEZIFISCH_ZYL2_WERT | unsigned int | mg/hub | 0.003052 | -100.000000 | IVPlaus_qFBCCyl_1 | Cylinder specific FBC balancing quantity for cylinder 2 (in order) | |
IMKZ3 | 0x149E | STAT_MENGENKORREKTUR_ZYLINDERSPEZIFISCH_ZYL3_WERT | unsigned int | mg/hub | 0.003052 | -100.000000 | IVPlaus_qFBCCyl_2 | Cylinder-specific FBC balancing quantity for cylinder 3 (in order) | |
IMKZ4 | 0x149F | STAT_MENGENKORREKTUR_ZYLINDERSPEZIFISCH_ZYL4_WERT | unsigned int | mg/hub | 0.003052 | -100.000000 | IVPlaus_qFBCCyl_3 | Cylinder-specific FBC balancing quantity for cylinder 4 (in order) | |
IMKZ5 | 0x14A0 | STAT_MENGENKORREKTUR_ZYLINDERSPEZIFISCH_ZYL5_WERT | unsigned int | mg/hub | 0.003052 | -100.000000 | IVPlaus_qFBCCyl_4 | Cylinder-specific FBC balancing quantity for cylinder 5 (in order) | |
IMKZ6 | 0x14A1 | STAT_MENGENKORREKTUR_ZYLINDERSPEZIFISCH_ZYL6_WERT | unsigned int | mg/hub | 0.003052 | -100.000000 | IVPlaus_qFBCCyl_5 | Cylinder-specific FBC balancing quantity for cylinder 6 (in order) | |
FBC_qDvtCylPhys_01_0 | 0x14B4 | STAT_FBC_qDvtCylPhys0_WERT | unsigned int | mg/hub | 0.003052 | -100.000000 | FBC_qDvtCylPhys_01_0 | I-portion of the current cylinder-specific correction quantity for cylinder 1 (in geometric order) | |
FBC_qDvtCylPhys_01_1 | 0x14B5 | STAT_FBC_qDvtCylPhys1_WERT | unsigned int | mg/hub | 0.003052 | -100.000000 | FBC_qDvtCylPhys_01_1 | I-portion of the current cylinder-specific correction quantity for cylinder 2 (in geometric order) | |
FBC_qDvtCylPhys_01_2 | 0x14B6 | STAT_FBC_qDvtCylPhys2_WERT | unsigned int | mg/hub | 0.003052 | -100.000000 | FBC_qDvtCylPhys_01_2 | I-portion of the current cylinder-specific correction quantity for cylinder 3 (in geometric order) | |
FBC_qDvtCylPhys_01_3 | 0x14B7 | STAT_FBC_qDvtCylPhys3_WERT | unsigned int | mg/hub | 0.003052 | -100.000000 | FBC_qDvtCylPhys_01_3 | I-portion of the current cylinder-specific correction quantity for cylinder 4 (in geometric order) | |
FBC_qDvtCyl_0 | 0x14BE | STAT_FBC_qDvtCyl0_WERT | unsigned int | mg/hub | 0.001526 | -50.000000 | FBC_qDvtCyl_0 | I-portion of the current cylinder-specific correction quantity for cylinder 1 (in order) | |
FBC_qDvtCyl_1 | 0x14BF | STAT_FBC_qDvtCyl1_WERT | unsigned int | mg/hub | 0.001526 | -50.000000 | FBC_qDvtCyl_1 | I-portion of the current cylinder-specific correction quantity for cylinder 2 (in order) | |
FBC_qDvtCyl_2 | 0x14C0 | STAT_FBC_qDvtCyl2_WERT | unsigned int | mg/hub | 0.001526 | -50.000000 | FBC_qDvtCyl_2 | I-portion of the current cylinder-specific correction quantity for cylinder 3 (in order) | |
FBC_qDvtCyl_3 | 0x14C1 | STAT_FBC_qDvtCyl3_WERT | unsigned int | mg/hub | 0.001526 | -50.000000 | FBC_qDvtCyl_3 | I-portion of the current cylinder-specific correction quantity for cylinder 4 (in order) | |
FBC_DXSl_mp_0 | 0x14C4 | STAT_FBC_DXSl_mp_0_WERT | unsigned int | % | 0.003052 | -100.000000 | FBC_DXSl_mp_0 | Encoder wheel learning error - tooth pitch error 0 | |
FBC_DXSl_mp_1 | 0x14C5 | STAT_FBC_DXSl_mp_1_WERT | unsigned int | % | 0.003052 | -100.000000 | FBC_DXSl_mp_1 | Encoder wheel learning set â€" tooth pitch error 1 | |
FBC_DXSl_mp_2 | 0x14C6 | STAT_FBC_DXSl_mp_2_WERT | unsigned int | % | 0.003052 | -100.000000 | FBC_DXSl_mp_2 | Encoder gear learning set â€" tooth pitch error 2 | |
FBC_DXSl_mp_3 | 0x14C7 | STAT_FBC_DXSl_mp_3_WERT | unsigned int | % | 0.003052 | -100.000000 | FBC_DXSl_mp_3 | Encoder gear learning set - Tooth pitch error 3 | |
FBC_DXSl_mp_4 | 0x14C8 | STAT_FBC_DXSl_mp_4_WERT | unsigned int | % | 0.003052 | -100.000000 | FBC_DXSl_mp_4 | Encoder gear learning error - Tooth pitch error 4 | |
FBC_DXSl_mp_5 | 0x14C9 | STAT_FBC_DXSl_mp_5_WERT | unsigned int | % | 0.003052 | -100.000000 | FBC_DXSl_mp_5 | Encoder gear learning error - Tooth pitch error 5 | |
FBC_DXSl_mp_6 | 0x14CA | STAT_FBC_DXSl_mp_6_WERT | unsigned int | % | 0.003052 | -100.000000 | FBC_DXSl_mp_6 | Donor gear learning set - Tooth pitch error 6 | |
FBC_DXSl_mp_7 | 0x14CB | STAT_FBC_DXSl_mp_7_WERT | unsigned int | % | 0.003052 | -100.000000 | FBC_DXSl_mp_7 | Donor gear learning set - Tooth pitch error 7 | |
FBC_DXSl_mp_8 | 0x14CC | STAT_FBC_DXSl_mp_8_WERT | unsigned int | % | 0.003052 | -100.000000 | FBC_DXSl_mp_8 | Encoder gear learning set - Tooth pitch error 8 | |
FBC_DXSl_mp_9 | 0x14CD | STAT_FBC_DXSl_mp_9_WERT | unsigned int | % | 0.003052 | -100.000000 | FBC_DXSl_mp_9 | Encoder gear learning set - Tooth pitch error 9 | |
FBC_DXSl_mp_10 | 0x14CE | STAT_FBC_DXSl_mp_10_WERT | unsigned int | % | 0.003052 | -100.000000 | FBC_DXSl_mp_10 | Encoder gear learning set - Tooth pitch error 10 | |
FBC_DXSl_mp_11 | 0x14CF | STAT_FBC_DXSl_mp_11_WERT | unsigned int | % | 0.003052 | -100.000000 | FBC_DXSl_mp_11 | Encoder wheel learning set - tooth pitch error 11 | |
IFMAQ | 0x14D2 | STAT_MMA_FEHLERMODELL_MENGENFEHLER_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapOut_mp | Injection quantity from learning map for current operating point | |
FMO_qEmiCtlCor | 0x14D3 | STAT_FMO_qEmiCtlCor_WERT | unsigned int | mg/Hub | 0.010000 | -327.670000 | FMO_qEmiCtlCor | FMO correction quantity for exhaust-relevant control loops | |
FMO_stSwtOff | 0x14DB | STAT_FMO_stSwtOff_WERT | unsigned char | - | 1.000000 | 0.000000 | FMO_stSwtOff | Switch-off state of the adaptation | |
IFMATIFO | 0x14DC | STAT_MMA_FEHLERMODELL_BETRIEBSZEIT_WERT | unsigned long | - | 1.000000 | 0.000000 | FMO_ctLrnEvt_mp | Number of learning events since the last reset of the learning map | |
FBC_qDvtCylPhys_0 | 0x14E6 | STAT_FBC_qDvtCylPhys_0_WERT | unsigned char | mg/hub | 0.156863 | -20.000000 | FBC_qDvtCylPhys_0 | I-portion of the current cylinder-specific correction quantity for cylinder 1 (in geometric order) (1 byte) | |
FBC_qDvtCylPhys_1 | 0x14E7 | STAT_FBC_qDvtCylPhys_1_WERT | unsigned char | mg/hub | 0.156863 | -20.000000 | FBC_qDvtCylPhys_1 | I-portion of the current cylinder-specific correction quantity for cylinder 2 (in geometric order) (1 byte) | |
FBC_qDvtCylPhys_2 | 0x14E8 | STAT_FBC_qDvtCylPhys_2_WERT | unsigned char | mg/hub | 0.156863 | -20.000000 | FBC_qDvtCylPhys_2 | I-portion of the current cylinder-specific correction quantity for cylinder 3 (in geometric order) (1 byte) | |
FBC_qDvtCylPhys_3 | 0x14E9 | STAT_FBC_qDvtCylPhys_3_WERT | unsigned char | mg/hub | 0.156863 | -20.000000 | FBC_qDvtCylPhys_3 | I-portion of the current cylinder-specific correction quantity for cylinder 4 (in geometric order) (1 byte) | |
IFMA00 | 0x152D | STAT_MENGENMITTELWERTADAPTION_ROW0_0_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt0NPnt_mp_0 | Map values for the first quantity support point (first line in the correction map) 0 | |
IFMA01 | 0x152E | STAT_MENGENMITTELWERTADAPTION_ROW0_1_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt0NPnt_mp_1 | Map values for first quantity control point (first line in correction map) 1 | |
IFMA02 | 0x152F | STAT_MENGENMITTELWERTADAPTION_ROW0_2_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt0NPnt_mp_2 | Map values for first quantity control point (first line in correction map) 2 | |
IFMA03 | 0x1530 | STAT_MENGENMITTELWERTADAPTION_ROW0_3_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt0NPnt_mp_3 | Map values for first quantity control point (first line in correction map) 3 | |
IFMA04 | 0x1531 | STAT_MENGENMITTELWERTADAPTION_ROW0_4_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt0NPnt_mp_4 | Map values for first quantity control point (first line in correction map) 4 | |
IFMA05 | 0x1532 | STAT_MENGENMITTELWERTADAPTION_ROW0_5_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt0NPnt_mp_5 | Map values for first quantity checkpoint (first line in correction map) 5 | |
IFMA06 | 0x1533 | STAT_MENGENMITTELWERTADAPTION_ROW0_6_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt0NPnt_mp_6 | Map values for first quantity checkpoint (first line in correction map) 6 | |
IFMA07 | 0x1534 | STAT_MENGENMITTELWERTADAPTION_ROW0_7_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt0NPnt_mp_7 | Map values for first quantity checkpoint (first line in correction map) 7 | |
IFMA10 | 0x1537 | STAT_MENGENMITTELWERTADAPTION_ROW1_0_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt1NPnt_mp_0 | Map values for second quantity control point (second line in correction map) 0 | |
IFMA11 | 0x1538 | STAT_MENGENMITTELWERTADAPTION_ROW1_1_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt1NPnt_mp_1 | Map values for second quantity control point (second line in correction map) 1 | |
IFMA12 | 0x1539 | STAT_MENGENMITTELWERTADAPTION_ROW1_2_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt1NPnt_mp_2 | Map values for second quantity control point (second line in correction map) 2 | |
IFMA13 | 0x153A | STAT_MENGENMITTELWERTADAPTION_ROW1_3_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt1NPnt_mp_3 | Map values for second quantity control point (second line in correction map) 3 | |
IFMA14 | 0x153B | STAT_MENGENMITTELWERTADAPTION_ROW1_4_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt1NPnt_mp_4 | Map values for second quantity control point (second line in correction map) 4 | |
IFMA15 | 0x153C | STAT_MENGENMITTELWERTADAPTION_ROW1_5_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt1NPnt_mp_5 | Map values for second quantity control point (second line in correction map) 5 | |
IFMA16 | 0x153D | STAT_MENGENMITTELWERTADAPTION_ROW1_6_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt1NPnt_mp_6 | Map values for second quantity control point (second line in correction map) 6 | |
IFMA17 | 0x153E | STAT_MENGENMITTELWERTADAPTION_ROW1_7_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt1NPnt_mp_7 | Map values for second quantity control point (second line in correction map) 7 | |
IFMA20 | 0x1541 | STAT_MENGENMITTELWERTADAPTION_ROW2_0_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt2NPnt_mp_0 | Map values for third quantity control point (third line in correction map) 0 | |
IFMA21 | 0x1542 | STAT_MENGENMITTELWERTADAPTION_ROW2_1_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt2NPnt_mp_1 | Map values for third quantity control point (third line in correction map) 1 | |
IFMA22 | 0x1543 | STAT_MENGENMITTELWERTADAPTION_ROW2_2_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt2NPnt_mp_2 | Map values for third quantity control point (third line in correction map) 2 | |
IFMA23 | 0x1544 | STAT_MENGENMITTELWERTADAPTION_ROW2_3_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt2NPnt_mp_3 | Map values for third quantity control point (third line in correction map) 3 | |
IFMA24 | 0x1545 | STAT_MENGENMITTELWERTADAPTION_ROW2_4_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt2NPnt_mp_4 | Map values for third quantity control point (third line in correction map) 4 | |
IFMA25 | 0x1546 | STAT_MENGENMITTELWERTADAPTION_ROW2_5_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt2NPnt_mp_5 | Map values for third quantity control point (third line in correction map) 5 | |
IFMA26 | 0x1547 | STAT_MENGENMITTELWERTADAPTION_ROW2_6_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt2NPnt_mp_6 | Map values for third quantity control point (third line in correction map) 6 | |
IFMA27 | 0x1548 | STAT_MENGENMITTELWERTADAPTION_ROW2_7_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt2NPnt_mp_7 | Map values for third quantity control point (third line in correction map) 7 | |
IFMA30 | 0x154B | STAT_MENGENMITTELWERTADAPTION_ROW3_0_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt3NPnt_mp_0 | Map values for fourth quantity control point (fourth line in correction map) 0 | |
IFMA31 | 0x154C | STAT_MENGENMITTELWERTADAPTION_ROW3_1_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt3NPnt_mp_1 | Map values for fourth quantity control point (fourth line in correction map) 1 | |
IFMA32 | 0x154D | STAT_MENGENMITTELWERTADAPTION_ROW3_2_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt3NPnt_mp_2 | Map values for fourth quantity measuring point (fourth line in correction map) 2 | |
IFMA33 | 0x154E | STAT_MENGENMITTELWERTADAPTION_ROW3_3_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt3NPnt_mp_3 | Map values for fourth quantity measuring point (fourth line in correction map) 3 | |
IFMA34 | 0x154F | STAT_MENGENMITTELWERTADAPTION_ROW3_4_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt3NPnt_mp_4 | Map values for fourth quantity control point (fourth line in correction map) 4 | |
IFMA35 | 0x1550 | STAT_MENGENMITTELWERTADAPTION_ROW3_5_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt3NPnt_mp_5 | Map values for fourth quantity control point (fourth line in correction map) 5 | |
IFMA36 | 0x1551 | STAT_MENGENMITTELWERTADAPTION_ROW3_6_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt3NPnt_mp_6 | Map values for fourth quantity control point (fourth line in correction map) 6 | |
IFMA37 | 0x1552 | STAT_MENGENMITTELWERTADAPTION_ROW3_7_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt3NPnt_mp_7 | Map values for fourth quantity control point (fourth line in correction map) 7 | |
IFMA40 | 0x1555 | STAT_MENGENMITTELWERTADAPTION_ROW4_0_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt4NPnt_mp_0 | Map values for the fifth quantity control point (fifth line in the correction map) 0 | |
IFMA41 | 0x1556 | STAT_MENGENMITTELWERTADAPTION_ROW4_1_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt4NPnt_mp_1 | Map values for the fifth quantity control point (fifth line in the correction map) 1 | |
IFMA42 | 0x1557 | STAT_MENGENMITTELWERTADAPTION_ROW4_2_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt4NPnt_mp_2 | Map values for the fifth quantity control point (fifth line in the correction map) 2 | |
IFMA43 | 0x1558 | STAT_MENGENMITTELWERTADAPTION_ROW4_3_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt4NPnt_mp_3 | Map values for the fifth quantity control point (fifth line in the correction map) 3 | |
IFMA44 | 0x1559 | STAT_MENGENMITTELWERTADAPTION_ROW4_4_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt4NPnt_mp_4 | Map values for the fifth quantity control point (fifth line in the correction map) 4 | |
IFMA45 | 0x155A | STAT_MENGENMITTELWERTADAPTION_ROW4_5_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt4NPnt_mp_5 | Map values for the fifth quantity control point (fifth line in the correction map) 5 | |
IFMA46 | 0x155B | STAT_MENGENMITTELWERTADAPTION_ROW4_6_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt4NPnt_mp_6 | Map values for the fifth quantity control point (fifth line in the correction map) 6 | |
IFMA47 | 0x155C | STAT_MENGENMITTELWERTADAPTION_ROW4_7_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt4NPnt_mp_7 | Map values for the fifth quantity control point (fifth line in the correction map) 7 | |
IFMA50 | 0x155F | STAT_MENGENMITTELWERTADAPTION_ROW5_0_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt5NPnt_mp_0 | Map values for sixth quantity measuring point (sixth line in correction map) 0 | |
IFMA51 | 0x1560 | STAT_MENGENMITTELWERTADAPTION_ROW5_1_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt5NPnt_mp_1 | Map values for sixth quantity control point (sixth line in correction map) 1 | |
IFMA52 | 0x1561 | STAT_MENGENMITTELWERTADAPTION_ROW5_2_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt5NPnt_mp_2 | Map values for sixth quantity measuring point (sixth line in correction map) 2 | |
IFMA53 | 0x1562 | STAT_MENGENMITTELWERTADAPTION_ROW5_3_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt5NPnt_mp_3 | Map values for sixth quantity measuring point (sixth line in correction map) 3 | |
IFMA54 | 0x1563 | STAT_MENGENMITTELWERTADAPTION_ROW5_4_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt5NPnt_mp_4 | Map values for sixth quantity measuring point (sixth line in correction map) 4 | |
IFMA55 | 0x1564 | STAT_MENGENMITTELWERTADAPTION_ROW5_5_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt5NPnt_mp_5 | Map values for sixth quantity measuring point (sixth line in correction map) 5 | |
IFMA56 | 0x1565 | STAT_MENGENMITTELWERTADAPTION_ROW5_6_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt5NPnt_mp_6 | Map values for sixth quantity measuring point (sixth line in correction map) 6 | |
IFMA57 | 0x1566 | STAT_MENGENMITTELWERTADAPTION_ROW5_7_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt5NPnt_mp_7 | Map values for sixth quantity measuring point (sixth line in correction map) 7 | |
IFMA60 | 0x1569 | STAT_MENGENMITTELWERTADAPTION_ROW6_0_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt6NPnt_mp_0 | Map values for seventh quantity control point (seventh line in correction map) 0 | |
IFMA61 | 0x156A | STAT_MENGENMITTELWERTADAPTION_ROW6_1_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt6NPnt_mp_1 | Map values for seventh quantity control point (seventh line in correction map) 1 | |
IFMA62 | 0x156B | STAT_MENGENMITTELWERTADAPTION_ROW6_2_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt6NPnt_mp_2 | Map values for seventh quantity control point (seventh line in correction map) 2 | |
IFMA63 | 0x156C | STAT_MENGENMITTELWERTADAPTION_ROW6_3_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt6NPnt_mp_3 | Map values for seventh quantity control point (seventh line in correction map) 3 | |
IFMA64 | 0x156D | STAT_MENGENMITTELWERTADAPTION_ROW6_4_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt6NPnt_mp_4 | Map values for seventh quantity control point (seventh line in correction map) 4 | |
IFMA65 | 0x156E | STAT_MENGENMITTELWERTADAPTION_ROW6_5_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt6NPnt_mp_5 | Map values for seventh quantity control point (seventh line in correction map) 5 | |
IFMA66 | 0x156F | STAT_MENGENMITTELWERTADAPTION_ROW6_6_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt6NPnt_mp_6 | Map values for seventh quantity control point (seventh line in correction map) 6 | |
IFMA67 | 0x1570 | STAT_MENGENMITTELWERTADAPTION_ROW6_7_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt6NPnt_mp_7 | Map values for seventh quantity control point (seventh line in correction map) 7 | |
IFMA70 | 0x1573 | STAT_MENGENMITTELWERTADAPTION_ROW7_0_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt7NPnt_mp_0 | Map values for eighth quantity control point (eighth line in correction map) 0 | |
IFMA71 | 0x1574 | STAT_MENGENMITTELWERTADAPTION_ROW7_1_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt7NPnt_mp_1 | Map values for eighth quantity control point (eighth line in correction map) 1 | |
IFMA72 | 0x1575 | STAT_MENGENMITTELWERTADAPTION_ROW7_2_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt7NPnt_mp_2 | Map values for eighth quantity measuring point (eighth line in correction map) 2 | |
IFMA73 | 0x1576 | STAT_MENGENMITTELWERTADAPTION_ROW7_3_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt7NPnt_mp_3 | Map values for eighth quantity measuring point (eighth line in correction map) 3 | |
IFMA74 | 0x1577 | STAT_MENGENMITTELWERTADAPTION_ROW7_4_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt7NPnt_mp_4 | Map values for eighth quantity measuring point (eighth line in correction map) 4 | |
IFMA75 | 0x1578 | STAT_MENGENMITTELWERTADAPTION_ROW7_5_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt7NPnt_mp_5 | Map values for eighth quantity control point (eighth line in correction map) 5 | |
IFMA76 | 0x1579 | STAT_MENGENMITTELWERTADAPTION_ROW7_6_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt7NPnt_mp_6 | Map values for eighth quantity checkpoint (eighth line in correction map) 6 | |
IFMA77 | 0x157A | STAT_MENGENMITTELWERTADAPTION_ROW7_7_WERT | unsigned int | mg/hub | 0.010000 | -327.670000 | FMO_qMapQntPnt7NPnt_mp_7 | Map values for the eighth flow control point (eighth line in the correction map) 7 | |
ISSYN | 0x15E2 | STAT_SYNCHRONISATION_KW_NW_WERT | unsigned char | - | 1.000000 | 0.000000 | Epm_stSync | Synchronisation status | |
Epm_stOpMode | 0x15E3 | STAT_Epm_stOpMode_WERT | unsigned char | - | 1.000000 | 0.000000 | Epm_stOpMode | Operating mode status | |
EpmHCrS_stSigMode | 0x15E4 | STAT_EpmHCrS_stSigMode_WERT | unsigned char | - | 1.000000 | 0.000000 | EpmHCrS_stSigMode | State of the crankshaft signal evaluation | |
EpmCaS_phiOfsCorr | 0x15E5 | STAT_EpmCaS_phiOfsCorr_WERT | unsigned int | degCrS | 0.003052 | -100.000000 | EpmCaS_phiOfsCorr | Offset angle for camshaft (raw value) | |
Epm_stSpd | 0x15E6 | STAT_Epm_stSpd_WERT | unsigned char | - | 1.000000 | 0.000000 | Epm_stSpd | Selection of engine speed | |
TrbnDsRLam_rLamRec | 0x15F4 | STAT_TrbnDsRLam_rLamRec_WERT | unsigned int | - | 0.001000 | 0.000000 | TrbnDsRLam_rLamRec | Interface message | |
GlwCtl_stGlw | 0x15FE | STAT_GlwCtl_stGlw_WERT | unsigned int | - | 1.000000 | 0.000000 | GlwCtl_stGlw | Glow state (from state machine) | |
IAGLL | 0x15FF | STAT_GLUEHANZEIGE_ANSTEUERUNG_WERT | unsigned char | - | 1.000000 | 0.000000 | GlwLmp_st | Glow lamp control | |
GlwEcu_stHighresCold | 0x1600 | STAT_GlwEcu_stHighresCold_WERT | unsigned char | - | 1.000000 | 0.000000 | GlwEcu_stHighresCold | Status - Cold resistance of the glow pins too high (bitmasked) | |
GlwEcu_stHighresHot | 0x1601 | STAT_GlwEcu_stHighresHot_WERT | unsigned char | - | 1.000000 | 0.000000 | GlwEcu_stHighresHot | Status - Hot resistance of the filament pins too high (bit-masked) | |
GlwEcu_stLowresCold | 0x1602 | STAT_GlwEcu_stLowresCold_WERT | unsigned char | - | 1.000000 | 0.000000 | GlwEcu_stLowresCold | Status - Cold resistance of the glow pencils too low (bit-masked) | |
GlwEcu_stLowresHot | 0x1603 | STAT_GlwEcu_stLowresHot_WERT | unsigned char | - | 1.000000 | 0.000000 | GlwEcu_stLowresHot | Status - Hot resistance of the annealing pins too low (bitmasked) | |
GlwEcu_stHSSOpen | 0x1604 | STAT_GlwEcu_stHSSOpen_WERT | unsigned char | - | 1.000000 | 0.000000 | GlwEcu_stHSSOpen | Status - Semiconductor switching stage interrupted (bit-masked) | |
GlwEcu_stHSSShort | 0x1605 | STAT_GlwEcu_stHSSShort_WERT | unsigned char | - | 1.000000 | 0.000000 | GlwEcu_stHSSShort | Status - solid-state switching stage permanently activated (bit-masked) | |
GlwEcu_stGPCMConfig_mp | 0x1606 | STAT_GlwEcu_stGPCMConfig_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | GlwEcu_stGPCMConfig_mp | Status of the saved configuration of the glow control unit | |
GlwEcu_stGPCMDiag | 0x1607 | STAT_GlwEcu_stGPCMDiag_WERT | unsigned char | - | 1.000000 | 0.000000 | GlwEcu_stGPCMDiag | Status of the diagnosis of the glow controller | |
GlwEcu_stGPType_mp | 0x1608 | STAT_GlwEcu_stGPType_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | GlwEcu_stGPType_mp | Glow pen type | |
IAGLU | 0x1609 | STAT_GLUEHSYSTEM_ANSTEUERUNG_WERT | unsigned int | W | 0.100000 | 0.000000 | GlwEcu_pwrGlow | Power consumption of the glow controller | |
GlwEcu_tGlwPlg_mp | 0x160B | STAT_GlwEcu_tGlwPlg_mp_WERT | unsigned int | degC | 0.100000 | -273.140000 | GlwEcu_tGlwPlg_mp | Current glow temperature | |
GlwEcu_lSum_mp | 0x160D | STAT_GlwEcu_lSum_mp_WERT | unsigned int | km | 1.000000 | 0.000000 | GlwEcu_lSum_mp | Odometer for installed glow control unit | |
Tw_noagrcntg | 0x1645 | STAT_Tw_noagrcntg_WERT | unsigned long | - | 1.000000 | 0.000000 | Tw_noagrcntg | Counter tuning probability non-AGR case total | |
Tw_noagr | 0x1647 | STAT_Tw_noagr_WERT | unsigned int | - | 0.001526 | 0.000000 | Tw_noagr | Tuning probability non-AGR case | |
Tw_noagrmax | 0x1649 | STAT_Tw_noagrmax_WERT | unsigned int | - | 1.000000 | 0.000000 | Tw_noagrmax | max. tuning probability in non-AGR case | |
ManDet_rO2AdapFaultMean | 0x164B | STAT_ManDet_rO2AdapFaultMean_WERT | unsigned int | - | 0.000031 | -1.000000 | ManDet_rO2AdapFaultMean | mean deviation of oxygen concentration | |
ManDet_HistTw_0 | 0x164C | STAT_ManDet_HistTw0_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_0 | Ring buffer of the manipulation probability 0 | |
ManDet_HistTw_1 | 0x164D | STAT_ManDet_HistTw1_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_1 | Ring buffer of the manipulation probability 1 | |
ManDet_HistTw_2 | 0x164E | STAT_ManDet_HistTw2_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_2 | Ring buffer of manipulation probability 2 | |
ManDet_HistTw_3 | 0x164F | STAT_ManDet_HistTw3_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_3 | Ring buffer of manipulation probability 3 | |
ManDet_HistTw_4 | 0x1650 | STAT_ManDet_HistTw4_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_4 | Ring buffer of manipulation probability 4 | |
ManDet_HistTw_5 | 0x1651 | STAT_ManDet_HistTw5_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_5 | Ring buffer of the manipulation probability 5 | |
ManDet_HistTw_6 | 0x1652 | STAT_ManDet_HistTw6_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_6 | Ring buffer of the manipulation probability 6 | |
ManDet_HistTw_7 | 0x1653 | STAT_ManDet_HistTw7_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_7 | Ring buffer of the manipulation probability 7 | |
ManDet_HistTw_8 | 0x1654 | STAT_ManDet_HistTw8_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_8 | Ring buffer of the manipulation probability 8 | |
ManDet_HistTw_9 | 0x1655 | STAT_ManDet_HistTw9_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_9 | Ring buffer of the manipulation probability 9 | |
ManDet_HistTw_10 | 0x1656 | STAT_ManDet_HistTw10_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_10 | Ring buffer of the manipulation probability 10 | |
ManDet_HistTw_11 | 0x1657 | STAT_ManDet_HistTw11_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_11 | Ring buffer of the manipulation probability 11 | |
ManDet_HistTw_12 | 0x1658 | STAT_ManDet_HistTw12_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_12 | Ring buffer of the manipulation probability 12 | |
ManDet_HistTw_13 | 0x1659 | STAT_ManDet_HistTw13_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_13 | Ring buffer of the manipulation probability 13 | |
ManDet_HistTw_14 | 0x165A | STAT_ManDet_HistTw14_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_14 | Ring buffer of the manipulation probability 14 | |
ManDet_HistTw_15 | 0x165B | STAT_ManDet_HistTw15_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_15 | Ring buffer of the manipulation probability 15 | |
ManDet_HistTw_16 | 0x165C | STAT_ManDet_HistTw16_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_16 | Ring buffer of the manipulation probability 16 | |
ManDet_HistTw_17 | 0x165D | STAT_ManDet_HistTw17_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_17 | Ring buffer of the manipulation probability 17 | |
ManDet_HistTw_18 | 0x165E | STAT_ManDet_HistTw18_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_18 | Ring buffer of the manipulation probability 18 | |
ManDet_HistTw_19 | 0x165F | STAT_ManDet_HistTw19_WERT | unsigned char | % | 0.392157 | 0.000000 | ManDet_HistTw_19 | Ring buffer of the manipulation probability 19 | |
ManDet_HistKm_0 | 0x1660 | STAT_ManDet_HistKm0_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_0 | Ring buffer odometer reading 0 | |
ManDet_HistKm_1 | 0x1661 | STAT_ManDet_HistKm1_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_1 | Odometer reading 1 ring buffer | |
ManDet_HistKm_2 | 0x1662 | STAT_ManDet_HistKm2_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_2 | Odometer reading 2 ring buffer | |
ManDet_HistKm_3 | 0x1663 | STAT_ManDet_HistKm3_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_3 | Odometer reading 3 ring buffer | |
ManDet_HistKm_4 | 0x1664 | STAT_ManDet_HistKm4_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_4 | Odometer reading 4 ring buffer | |
ManDet_HistKm_5 | 0x1665 | STAT_ManDet_HistKm5_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_5 | Ring buffer Odometer reading 5 | |
ManDet_HistKm_6 | 0x1666 | STAT_ManDet_HistKm6_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_6 | Ring buffer Odometer reading 6 | |
ManDet_HistKm_7 | 0x1667 | STAT_ManDet_HistKm7_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_7 | Ring buffer Odometer reading 7 | |
ManDet_HistKm_8 | 0x1668 | STAT_ManDet_HistKm8_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_8 | Ring buffer Odometer reading 8 | |
ManDet_HistKm_9 | 0x1669 | STAT_ManDet_HistKm9_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_9 | Ring buffer Odometer reading 9 | |
ManDet_HistKm_10 | 0x166A | STAT_ManDet_HistKm10_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_10 | Ring buffer Odometer reading 10 | |
ManDet_HistKm_11 | 0x166B | STAT_ManDet_HistKm11_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_11 | Ring buffer Odometer reading 11 | |
ManDet_HistKm_12 | 0x166C | STAT_ManDet_HistKm12_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_12 | Ring buffer Odometer reading 12 | |
ManDet_HistKm_13 | 0x166D | STAT_ManDet_HistKm13_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_13 | Ring buffer Odometer reading 13 | |
ManDet_HistKm_14 | 0x166E | STAT_ManDet_HistKm14_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_14 | Ring buffer Odometer reading 14 | |
ManDet_HistKm_15 | 0x166F | STAT_ManDet_HistKm15_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_15 | Ring buffer Odometer reading 15 | |
ManDet_HistKm_16 | 0x1670 | STAT_ManDet_HistKm16_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_16 | Ring buffer Odometer reading 16 | |
ManDet_HistKm_17 | 0x1671 | STAT_ManDet_HistKm17_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_17 | Ring buffer Odometer reading 17 | |
ManDet_HistKm_18 | 0x1672 | STAT_ManDet_HistKm18_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_18 | Ring buffer Odometer reading 18 | |
ManDet_HistKm_19 | 0x1673 | STAT_ManDet_HistKm19_WERT | unsigned int | km | 10.000000 | 0.000000 | ManDet_HistKm_19 | Ring buffer odometer reading 19 | |
Reset_stSyCSub | 0x16A7 | STAT_Reset_stSyCSub_WERT | unsigned char | - | 1.000000 | 0.000000 | Reset_stSyCSub | Current system/ECU sub-state (recovery - measured variable) | |
Reset_Env_xId_mp | 0x16A8 | STAT_Reset_Env_xId_mp_WERT | unsigned int | - | 1.000000 | 0.000000 | Reset_Env_xId_mp | ID of the last reset cause (Recovery - measured value) | |
Reset_Env_adLoc_mp | 0x16A9 | STAT_Reset_Env_adLoc_mp_WERT | unsigned long | hex | 1.000000 | 0.000000 | Reset_Env_adLoc_mp | Address at which the last reset was triggered (Recovery - measurement unit) | |
Reset_lSum_8km | 0x16AA | STAT_Reset_lSum_WERT | unsigned int | km | 8.000000 | 0.000000 | Reset_lSum_8km | Mileage (resolution 8 km) (Recovery - measurement unit) | |
Reset_mAirPerCyl | 0x16AB | STAT_Reset_mAirPerCyl_WERT | unsigned char | mg/Hub | 6.274510 | 0.000000 | Reset_mAirPerCyl | Air mass per cylinder (recovery measurement) | |
Reset_nEng | 0x16AC | STAT_Reset_nEng_WERT | unsigned int | rpm | 0.091554 | 0.000000 | Reset_nEng | Engine speed (recovery - measured variable) | |
Reset_pFlt | 0x16AD | STAT_Reset_pFlt_WERT | unsigned char | bar | 7.843137 | 0.000000 | Reset_pFlt | Maximum rail pressure (Recovery - measured variable) | |
Reset_qSetUnBal | 0x16AE | STAT_InjCtl_qSetUnBal_WERT | unsigned char | mg/hub | 0.392157 | 0.000000 | Reset_qSetUnBal | Current injection quantity (Recovery - measured variable) | |
Reset_tEng | 0x16AF | STAT_Reset_tEng_WERT | unsigned char | degC | 1.000000 | -50.000000 | Reset_tEng | engine temperature (recovery - measured variable) | |
Reset_uBatt | 0x16B0 | STAT_Reset_uBatt_WERT | unsigned char | mV | 100.000000 | 0.000000 | Reset_uBatt | battery voltage (recovery - measured variable) | |
Reset_Env_xUserValue | 0x16B1 | STAT_Reset_Env_xUserValue_WERT | unsigned long | - | 1.000000 | 0.000000 | Reset_Env_xUserValue | User-specific value of the last reset cause (Recovery - measured variable) | |
Reset_lSum_1km | 0x16B2 | STAT_Reset_lSum_1km_WERT | unsigned long | km | 1.000000 | 0.000000 | Reset_lSum_1km | Odometer reading (resolution 1 km) (recovery - measured variable) | |
TECU_t | 0x16DA | STAT_TECU_t_WERT | unsigned int | degC | 0.007782 | -255.000000 | TECU_t | SG-internal temperature | |
TECU_tSens | 0x16DB | STAT_TECU_tSens_WERT | unsigned int | degC | 0.007782 | -255.000000 | TECU_tSens | SG-internal temperature (raw signal value) | |
MoFInjDat_tiTDCAvrg | 0x170C | STAT_MoFInjDat_tiTDCAvrg_WERT | unsigned int | us | 0.400000 | 0.000000 | MoFInjDat_tiTDCAvrg | Mean value of the average torque-effective actuation time per cylinder | |
MoFAPP_u | 0x170D | STAT_MoFAPP_u_WERT | unsigned char | mV | 19.531250 | 0.000000 | MoFAPP_u | Position of the accelerator pedal for function monitoring | |
MoFAPP_stTst | 0x170E | STAT_MoFAPP_stTst_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFAPP_stTst | Identifier for the release condition of the error check for the diagnosis | |
MoFESpd_nEng | 0x1710 | STAT_MoFESpd_nEng_WERT | unsigned char | rpm | 40.000000 | 0.000000 | MoFESpd_nEng | Engine speed in function monitoring | |
MoFESpd_stSync | 0x1711 | STAT_MoFESpd_stSync_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFESpd_stSync | Synchronisation status of the speed monitoring | |
MoFESpd_phiGT1Last | 0x1712 | STAT_MoFESpd_phiGT1Last_WERT | unsigned long | - | 1.000000 | 0.000000 | MoFESpd_phiGT1Last | Angle clock status from previous call of engine speed monitoring | |
MoFInjDat_stInjState | 0x1718 | STAT_MoFInjDat_stInjState_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFInjDat_stInjState | Status information about running injections | |
MoFETC_stTst | 0x171A | STAT_MoFETC_stTst_WERT | unsigned char | - | 1.000000 | 0.000000 | MoFETC_stTst | Plausibilised engine test status of the function monitor | |
MoFOvR_stRls | 0x1729 | STAT_MoFOvR_stRls_WERT | unsigned int | - | 1.000000 | 0.000000 | MoFOvR_stRls | Status of all enable bits for thrust monitoring | |
MoFDrDem_rAPP | 0x172A | STAT_MoFDrDem_rAPP_WERT | unsigned char | % | 0.390625 | 0.000000 | MoFDrDem_rAPP | Accelerator pedal value of the monitoring functions | |
MoFExtInt_trqPtd | 0x1739 | STAT_MoFExtInt_trqPtd_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | MoFExtInt_trqPtd | Permissible torque of the external interventions in the function monitoring | |
MoFDrAs_trqPtd | 0x173A | STAT_MoFDrAs_trqPtd_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | MoFDrAs_trqPtd | Permissible wheel torque of the driver assistance systems | |
MoFDrDem_trqPtd | 0x173B | STAT_MoFDrDem_trqPtd_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | MoFDrDem_trqPtd | permissible desired driver torque based on wheel torque | |
MoFCoVeh_trqVehPtd | 0x173E | STAT_MoFCoVeh_trqVehPtd_WERT | unsigned int | Nm | 0.114443 | -2500.000000 | MoFCoVeh_trqVehPtd | permissible torque of the vehicle functions | |
MoCSOP_stRdyMsg | 0x1752 | STAT_MoCSOP_stRdyMsg_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stRdyMsg | Level 1, 2 information on the status of the shadow test synchronisation and the question-answer communication. | |
MoCADC_st | 0x1758 | STAT_MoCADC_st_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCADC_st | ADC monitoring status info | |
MoCADC_ctDebTst | 0x1759 | STAT_MoCADC_ctDebTst_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCADC_ctDebTst | Error counter for checking the test voltage | |
MoCADC_facVltgRatio | 0x175A | STAT_MoCADC_facVltgRatio_WERT | unsigned int | 1/1 | 0.000977 | 0.000000 | MoCADC_facVltgRatio | Ratiometry correction factor in function monitoring | |
MoCCom_ctErrMM | 0x175B | STAT_MoCCom_ctErrMM_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCCom_ctErrMM | Error counter feedback from monitoring module | |
MoCCom_ctErrFC | 0x175C | STAT_MoCCom_ctErrFC_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCCom_ctErrFC | Error counter in the function computer for errors from the monitoring module | |
MoCCom_st | 0x175D | STAT_MoCCom_st_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCCom_st | Status bit strip for communication with monitoring module | |
MoCCom_ctErrSPI | 0x175E | STAT_MoCCom_ctErrSPI_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCCom_ctErrSPI | Error counter for SPI transmissions in communication with monitoring module | |
MoCCom_Query | 0x175F | STAT_MoCCom_Query_WERT | unsigned long | - | 1.000000 | 0.000000 | MoCCom_Query | Advanced question from monitoring module | |
MoCCom_Response | 0x1760 | STAT_MoCCom_Response_WERT | unsigned long | - | 1.000000 | 0.000000 | MoCCom_Response | Answer to question from monitoring module | |
MoCMem_st | 0x1761 | STAT_MoCMem_st_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCMem_st | Request for complete memory test in initialisation and status of complete ROM memory test | |
MoCRom_numRomPageErr | 0x1762 | STAT_MoCRom_numRomPageErr_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCRom_numRomPageErr | Faulty ROM page for single fault in complete ROM check | |
MoCRom_ptrTabIndexAct | 0x1763 | STAT_MoCRom_ptrTabIndexAct_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCRom_ptrTabIndexAct | Pointer for the current page of the complete ROM check to be checked. | |
MoCSOP_stRdy | 0x1764 | STAT_MoCSOP_stRdy_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stRdy | Status variable for synchronisation of shutdown path test and question/answer communication (test completed) | |
MoCSOP_stActvMsg | 0x1765 | STAT_MoCSOP_stActvMsg_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stActvMsg | Information for level 1,2: shutdown path test is active or WDA line is active (injections switched off) | |
MoCSOP_stAct | 0x1766 | STAT_MoCSOP_stAct_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stAct | Status variable for synchronisation of shutdown path test and question/answer communication | |
MoCSOP_stErr | 0x1767 | STAT_MoCSOP_stErr_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stErr | Status of communication via SPI bus to the monitoring module | |
MoCSOP_stLdRespTab | 0x1768 | STAT_MoCSOP_stLdRespTab_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stLdRespTab | Status variable - response table loaded | |
MoCSOP_ctDebPSDia | 0x176B | STAT_MoCSOP_ctDebPSDia_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_ctDebPSDia | Number of repetitions of a final stage test | |
MoCSOP_debugInfo_0 | 0x176D | STAT_MoCSOP_debugInfo0_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_debugInfo_0 | Debug info of the shutdown path test 0 | |
MoCSOP_debugInfo_1 | 0x176E | STAT_MoCSOP_debugInfo1_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_debugInfo_1 | Debug info of the switch-off path test 1 | |
MoCSOP_debugInfo_2 | 0x176F | STAT_MoCSOP_debugInfo2_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_debugInfo_2 | Debug info of the switch-off path test 2 | |
MoCSOP_debugInfo_3 | 0x1770 | STAT_MoCSOP_debugInfo3_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_debugInfo_3 | Debug info of the shutdown path test 3 | |
MoCSOP_debugInfo_4 | 0x1771 | STAT_MoCSOP_debugInfo4_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_debugInfo_4 | Debug info of the shutdown path test 4 | |
MoCSOP_debugInfo_5 | 0x1772 | STAT_MoCSOP_debugInfo5_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_debugInfo_5 | Debug info of the shutdown path test 5 | |
MoCSOP_ctIdx_mp | 0x1773 | STAT_MoCSOP_ctIdx_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_ctIdx_mp | Index for 2.2ms grid ring buffer measurement points | |
MoCSOP_stInnerSM_mp_0 | 0x1774 | STAT_MoCSOP_stInnerSM_mp0_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stInnerSM_mp_0 | Array copies (2.2ms raster values) of MoCSOP_stPrevCheckState 0 | |
MoCSOP_stInnerSM_mp_1 | 0x1775 | STAT_MoCSOP_stInnerSM_mp1_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stInnerSM_mp_1 | Array copies (2.2ms raster values) of MoCSOP_stPrevCheckState 1 | |
MoCSOP_stInnerSM_mp_2 | 0x1776 | STAT_MoCSOP_stInnerSM_mp2_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stInnerSM_mp_2 | Array copies (2.2ms raster values) of MoCSOP_stPrevCheckState 2 | |
MoCSOP_stInnerSM_mp_3 | 0x1777 | STAT_MoCSOP_stInnerSM_mp3_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stInnerSM_mp_3 | Array copies (2.2ms raster values) of MoCSOP_stPrevCheckState 3 | |
MoCSOP_stInnerSM_mp_4 | 0x1778 | STAT_MoCSOP_stInnerSM_mp4_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stInnerSM_mp_4 | Array copies (2.2ms raster values) of MoCSOP_stPrevCheckState 4 | |
MoCSOP_stExtSM_mp_0 | 0x1779 | STAT_MoCSOP_stExtSM_mp0_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stExtSM_mp_0 | MoCSOP_stCurrSt Array copies (in 2.2ms raster) 0 | |
MoCSOP_stExtSM_mp_1 | 0x177A | STAT_MoCSOP_stExtSM_mp1_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stExtSM_mp_1 | MoCSOP_stCurrSt Array copies (in 2.2ms raster) 1 | |
MoCSOP_stExtSM_mp_2 | 0x177B | STAT_MoCSOP_stExtSM_mp2_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stExtSM_mp_2 | MoCSOP_stCurrSt Array copies (in 2.2ms grid) 2 | |
MoCSOP_stExtSM_mp_3 | 0x177C | STAT_MoCSOP_stExtSM_mp3_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stExtSM_mp_3 | MoCSOP_stCurrSt Array copies (in 2.2ms grid) 3 | |
MoCSOP_stExtSM_mp_4 | 0x177D | STAT_MoCSOP_stExtSM_mp4_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stExtSM_mp_4 | MoCSOP_stCurrSt array copies (in 2.2ms grid) 4 | |
MoCSOP_ctErrMM_mp_0 | 0x177E | STAT_MoCSOP_ctErrMM_mp0_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_ctErrMM_mp_0 | Copy of the error counter from the monitoring module in the function computer 0 | |
MoCSOP_ctErrMM_mp_1 | 0x177F | STAT_MoCSOP_ctErrMM_mp1_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_ctErrMM_mp_1 | Copy of the error counter from the monitoring module in the functional computer 1 | |
MoCSOP_ctErrMM_mp_2 | 0x1780 | STAT_MoCSOP_ctErrMM_mp2_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_ctErrMM_mp_2 | Copy of the error counter from the monitoring module in the function computer 2 | |
MoCSOP_ctErrMM_mp_3 | 0x1781 | STAT_MoCSOP_ctErrMM_mp3_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_ctErrMM_mp_3 | Copy of the error counter from the monitoring module in the functional computer 3 | |
MoCSOP_ctErrMM_mp_4 | 0x1782 | STAT_MoCSOP_ctErrMM_mp4_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_ctErrMM_mp_4 | Copy of the error counter from the monitoring module in the functional computer 4 | |
MoCSOP_stMm_mp_0 | 0x1783 | STAT_MoCSOP_stMm_mp0_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stMm_mp_0 | Array copies (2.2ms raster values) from monitoring module status byte 0 | |
MoCSOP_stMm_mp_1 | 0x1784 | STAT_MoCSOP_stMm_mp1_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stMm_mp_1 | Array copies (2.2ms raster values) of monitoring module status byte 1 | |
MoCSOP_stMm_mp_2 | 0x1785 | STAT_MoCSOP_stMm_mp2_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stMm_mp_2 | Array copies (2.2ms raster values) of monitoring module state byte 2 | |
MoCSOP_stMm_mp_3 | 0x1786 | STAT_MoCSOP_stMm_mp3_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stMm_mp_3 | Array copies (2.2ms raster values) of monitoring module state byte 3 | |
MoCSOP_stMm_mp_4 | 0x1787 | STAT_MoCSOP_stMm_mp4_WERT | unsigned char | - | 1.000000 | 0.000000 | MoCSOP_stMm_mp_4 | Array copies (2.2ms raster values) of monitoring module state byte 4 | |
MoCSOP_tiRespMM_mp_0 | 0x1788 | STAT_MoCSOP_tiRespMM_mp0_WERT | unsigned long | - | 1.000000 | 0.000000 | MoCSOP_tiRespMM_mp_0 | Array copy (2.2ms raster values) for the response time set in monitoring module 0 | |
MoCSOP_tiRespMM_mp_1 | 0x1789 | STAT_MoCSOP_tiRespMM_mp1_WERT | unsigned long | - | 1.000000 | 0.000000 | MoCSOP_tiRespMM_mp_1 | Array copy (2.2ms raster values) for the response time 1 set in monitoring module | |
MoCSOP_tiRespMM_mp_2 | 0x178A | STAT_MoCSOP_tiRespMM_mp2_WERT | unsigned long | - | 1.000000 | 0.000000 | MoCSOP_tiRespMM_mp_2 | Array copy (2.2ms raster values) for response time 2 set in monitoring module | |
MoCSOP_tiRespMM_mp_3 | 0x178B | STAT_MoCSOP_tiRespMM_mp3_WERT | unsigned long | - | 1.000000 | 0.000000 | MoCSOP_tiRespMM_mp_3 | Array copy (2.2ms raster values) for the response time 3 set in monitoring module | |
MoCSOP_tiRespMM_mp_4 | 0x178C | STAT_MoCSOP_tiRespMM_mp4_WERT | unsigned long | - | 1.000000 | 0.000000 | MoCSOP_tiRespMM_mp_4 | Array copy (2.2ms raster values) for the response time set in the monitoring module 4 | |
MoCSOP_ctErrSPI | 0x178D | STAT_MoCSOP_ctErrSPI_WERT | unsigned int | - | 1.000000 | 0.000000 | MoCSOP_ctErrSPI | Error counter for SPI transmissions to the monitoring module or to the CJ945/R2S2 | |
MoCSOP_st | 0x178E | STAT_MoCSOP_st_WERT | unsigned int | - | 1.000000 | 0.000000 | MoCSOP_st | Status variable of the shutdown path test | |
MoCSOP_ctDebSOPTst | 0x178F | STAT_MoCSOP_ctDebSOPTst_WERT | unsigned int | - | 1.000000 | 0.000000 | MoCSOP_ctDebSOPTst | Number of repetitions of the shutdown path test (realisation of a time monitoring). | |
MoCCom_ctSOPTstActv | 0x1790 | STAT_MoCCom_ctSOPTstActv_WERT | unsigned int | - | 1.000000 | 0.000000 | MoCCom_ctSOPTstActv | Counter for the number of calls to active shutdown path test | |
Msa_prailstz1 | 0x17D4 | STAT_Msa_prailstz1_WERT | unsigned long | - | 1.000000 | 0.000000 | Msa_prailstz1 | Counter MSA start at rail pressure in the 1st range | |
Msa_prailstz2 | 0x17D5 | STAT_Msa_prailstz2_WERT | unsigned long | - | 1.000000 | 0.000000 | Msa_prailstz2 | Counter MSA start at rail pressure in the 2nd range | |
Msa_prailstz3 | 0x17D6 | STAT_Msa_prailstz3_WERT | unsigned long | - | 1.000000 | 0.000000 | Msa_prailstz3 | Counter MSA-start at rail pressure in 3rd range | |
Msa_strtz | 0x17D7 | STAT_Msa_strtz_WERT | unsigned long | - | 1.000000 | 0.000000 | Msa_strtz | Counter MSA-start | |
Msa_strtzges | 0x17D8 | STAT_Msa_strtzges_WERT | unsigned long | - | 1.000000 | 0.000000 | Msa_strtzges | Total start counter | |
Gbx_ctGbxNPosUnPls | 0x182E | STAT_Gbx_ctGbxNPosUnPls_WERT | unsigned char | - | 1.000000 | 0.000000 | Gbx_ctGbxNPosUnPls | Total error counter of the zero speed sensor plausibility check | |
Gbx_dNPos | 0x182F | STAT_Gbx_dNPos_WERT | unsigned int | % | 0.010000 | 0.000000 | Gbx_dNPos | Gbx_dNPos | |
GbxNPos_rRawNPos | 0x1830 | STAT_GbxNPos_rRawNPos_WERT | unsigned int | % | 0.010000 | 0.000000 | GbxNPos_rRawNPos | GbxNPos_rRawNPos | |
GbxNPos_tiPer_mp | 0x1831 | STAT_GbxNPos_tiPer_mp_WERT | unsigned long | us | 0.050000 | 0.000000 | GbxNPos_tiPer_mp | GbxNPos_tiPer_mp | |
GbxPos_numLvrPos | 0x1833 | STAT_GbxPos_numLvrPos_WERT | unsigned int | - | 0.003891 | 0.000000 | GbxPos_numLvrPos | Shift position RNGS sensor (full speed sensor) | |
INGEE | 0x1838 | STAT_GETRIEBEEINGANGSDREHZAHL_WERT | unsigned int | rpm | 0.500000 | 0.000000 | GbxSpd_nRev | Gearbox input speed | |
AFS_stRstLoDrftThres_mp | 0x1880 | STAT_AFS_stRstLoDrftThres_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | AFS_stRstLoDrftThres_mp | Status HFM detection | |
INMOT | 0x1881 | STAT_MOTORDREHZAHL_WERT | unsigned int | rpm | 0.500000 | 0.000000 | Epm_nEng | Engine speed | |
Epm_numCyl | 0x1882 | STAT_Epm_numCyl_WERT | unsigned char | - | 1.000000 | 0.000000 | Epm_numCyl | Configured number of cylinders | |
Rail_stDwn1HpTst | 0x189C | STAT_Rail_stDwn1HpTst_WERT | unsigned long | - | 1.000000 | 0.000000 | Rail_stDwn1HpTst | First status of depressurisation phase of high pressure test | |
Rail_stDwn2HpTst | 0x189D | STAT_Rail_stDwn2HpTst_WERT | unsigned long | - | 1.000000 | 0.000000 | Rail_stDwn2HpTst | Second status of the depressurisation phase of the high pressure test | |
Rail_stDwn3HpTst | 0x189E | STAT_Rail_stDwn3HpTst_WERT | unsigned long | - | 1.000000 | 0.000000 | Rail_stDwn3HpTst | Third status of the depressurisation phase of the high-pressure test | |
ISDH1 | 0x189F | STAT_STATUS_HPTEST_DRUCKABBAU1 | unsigned char | 0/1 | 1.000000 | 0.000000 | Rail_stDwnHpTst_0 | Status of the current depressurisation phase of the high-pressure test for step 1 | |
ISDH2 | 0x18A0 | STAT_STATUS_HPTEST_DRUCKABBAU2 | unsigned char | 0/1 | 1.000000 | 0.000000 | Rail_stDwnHpTst_1 | Status of the current depressurisation phase of the high pressure test for step 2 | |
ISDH3 | 0x18A1 | STAT_STATUS_HPTEST_DRUCKABBAU3 | unsigned char | 0/1 | 1.000000 | 0.000000 | Rail_stDwnHpTst_2 | Status of the current pressure decay phase of the high pressure test for step 3 | |
ISDH4 | 0x18A2 | STAT_STATUS_HPTEST_DRUCKABBAU4 | unsigned char | 0/1 | 1.000000 | 0.000000 | Rail_stDwnHpTst_3 | Status of the current pressure drop phase of the high pressure test for step 4 | |
ISDH5 | 0x18A3 | STAT_STATUS_HPTEST_DRUCKABBAU5 | unsigned char | 0/1 | 1.000000 | 0.000000 | Rail_stDwnHpTst_4 | Status of the current pressure drop phase of the high pressure test for step 5 | |
ISRHT | 0x18A4 | STAT_STATUS_BEDINGUNGEN_HPTEST | unsigned int | 0/1 | 1.000000 | 0.000000 | Rail_stRefHpTst | Status of the operating conditions of the high pressure test | |
ISSM0 | 0x18A5 | STAT_STATUS_HPTEST0 | unsigned char | 0/1 | 1.000000 | 0.000000 | Rail_stStMHpTst | Status of the high pressure test | |
ISUH1 | 0x18A6 | STAT_STATUS_HPTEST_DRUCKAUFBAU1 | unsigned char | 0/1 | 1.000000 | 0.000000 | Rail_stUpHpTst_0 | Array of statuses of the pressure build-up phases of the high pressure test for step 1 | |
ISUH2 | 0x18A7 | STAT_STATUS_HPTEST_DRUCKAUFBAU2 | unsigned char | 0/1 | 1.000000 | 0.000000 | Rail_stUpHpTst_1 | Array of statuses of the pressure build-up phases of the high-pressure test for step 2 | |
ISUH3 | 0x18A8 | STAT_STATUS_HPTEST_DRUCKAUFBAU3 | unsigned char | 0/1 | 1.000000 | 0.000000 | Rail_stUpHpTst_2 | Array of statuses of the pressure build-up phases of the high pressure test for step 3 | |
ISUH4 | 0x18A9 | STAT_STATUS_HPTEST_DRUCKAUFBAU4 | unsigned char | 0/1 | 1.000000 | 0.000000 | Rail_stUpHpTst_3 | Array of statuses of the pressure build-up phases of the high-pressure test for step 4 | |
ISUH5 | 0x18AA | STAT_STATUS_HPTEST_DRUCKAUFBAU5 | unsigned char | 0/1 | 1.000000 | 0.000000 | Rail_stUpHpTst_4 | Array of statuses of the pressure build-up phases of the high pressure test for step 5 | |
ITDH1 | 0x18AB | STAT_ZEIT_HPTEST_DRUCKABBAU1_WERT | unsigned int | ms | 10.000000 | 0.000000 | Rail_tiDwnHpTst_0 | Array of depressurisation times of the high pressure test for step 1 | |
ITDH2 | 0x18AC | STAT_ZEIT_HPTEST_DRUCKABBAU2_WERT | unsigned int | ms | 10.000000 | 0.000000 | Rail_tiDwnHpTst_1 | Array of depressurisation times of the high pressure test for step 2 | |
ITDH3 | 0x18AD | STAT_ZEIT_HPTEST_DRUCKABBAU3_WERT | unsigned int | ms | 10.000000 | 0.000000 | Rail_tiDwnHpTst_2 | Array of depressurisation times of the high pressure test for step 3 | |
ITDH4 | 0x18AE | STAT_ZEIT_HPTEST_DRUCKABBAU4_WERT | unsigned int | ms | 10.000000 | 0.000000 | Rail_tiDwnHpTst_3 | Array of depressurisation times of the high pressure test for step 4 | |
ITDH5 | 0x18AF | STAT_ZEIT_HPTEST_DRUCKABBAU5_WERT | unsigned int | ms | 10.000000 | 0.000000 | Rail_tiDwnHpTst_4 | Array of depressurisation times of the high pressure test for step 5 | |
ITDH6 | 0x18B0 | STAT_ZEIT_HPTEST_DRUCKABBAU6_WERT | unsigned int | ms | 10.000000 | 0.000000 | Rail_tiDwnHpTst_5 | Array of depressurisation times of the high pressure test for step 6 | |
ITDH7 | 0x18B1 | STAT_ZEIT_HPTEST_DRUCKABBAU7_WERT | unsigned int | ms | 10.000000 | 0.000000 | Rail_tiDwnHpTst_6 | Array of depressurisation times of the high pressure test for step 7 | |
ITUH1 | 0x18B2 | STAT_ZEIT_HPTEST_DRUCKAUFBAU1_WERT | unsigned int | ms | 10.000000 | 0.000000 | Rail_tiUpHpTst_0 | Array of durations of the pressure build-up phases of the high-pressure test for step 1 | |
ITUH2 | 0x18B3 | STAT_ZEIT_HPTEST_DRUCKAUFBAU2_WERT | unsigned int | ms | 10.000000 | 0.000000 | Rail_tiUpHpTst_1 | Array of durations of the pressure build-up phases of the high pressure test for step 2 | |
ITUH3 | 0x18B4 | STAT_ZEIT_HPTEST_DRUCKAUFBAU3_WERT | unsigned int | ms | 10.000000 | 0.000000 | Rail_tiUpHpTst_2 | Array of durations of the pressure build-up phases of the high pressure test for step 3 | |
ITUH4 | 0x18B5 | STAT_ZEIT_HPTEST_DRUCKAUFBAU4_WERT | unsigned int | ms | 10.000000 | 0.000000 | Rail_tiUpHpTst_3 | Array of durations of the pressure build-up phases of the high pressure test for step 4 | |
INHDR | 0x1900 | STAT_RUNUP_DREHZAHL_HIGH_DOWN_WERT | unsigned int | rpm | 0.500000 | 0.000000 | IVPlaus_nHiDwnRunUpTst | Speed at the beginning of the run-up phase of the run-up test | |
INHUR | 0x1901 | STAT_RUNUP_DREHZAHL_HIGH_UP_WERT | unsigned int | rpm | 0.500000 | 0.000000 | IVPlaus_nHiUpRunUpTst | Speed at the end of the run-up phase of the run-up test | |
INLDR | 0x1902 | STAT_RUNUP_DREHZAHL_LOW_DOWN_WERT | unsigned int | rpm | 0.500000 | 0.000000 | IVPlaus_nLoDwnRunUpTst | Speed at the end of the run-up phase of the run-up test | |
INLUR | 0x1903 | STAT_RUNUP_DREHZAHL_LOW_UP_WERT | unsigned int | rpm | 0.500000 | 0.000000 | IVPlaus_nLoUpRunUpTst | Speed at the beginning of the acceleration phase of the acceleration test | |
ISRRU | 0x1904 | STAT_RUNUP_STATUS_REFUSED_RUNUP | unsigned int | 0/1 | 1.000000 | 0.000000 | IVPlaus_stRefRunUpTst | Status at the end of the acceleration test | |
ITDRU | 0x1905 | STAT_RUNUP_ZEIT_DOWN_WERT | unsigned long | us | 0.400000 | 0.000000 | IVPlaus_tiDwnRunUpTst | Time for the run-up phase of the acceleration test | |
ITURU | 0x1906 | STAT_RUNUP_ZEIT_UP_WERT | unsigned long | us | 0.400000 | 0.000000 | IVPlaus_tiUpRunUpTst | Time for the run-up phase of the run-up test | |
ZFC_st_mp | 0x1964 | STAT_ZFC_st_mp_WERT | unsigned char | - | 1.000000 | 0.000000 | ZFC_st_mp | Status of the zero quantity calibration |
Sign up for free